At least 307 records · Page 17Linked to original sources

Comparison of octadecylsilica and graphitized carbon black as materials for solid-phase extraction of fungicide and insecticide residues from fruit and vegetables.

Methods for the determination of thirteen fungicide and insecticide residues by solid-phase extraction with C18 and graphitized carbon black (GCB) were evaluated. The extraction of the residues was achieved by using matrix solid-phase dispersion (MSPD) and more conventional polar solvent extraction followed by liquid-solid phase partitioning. Determination was carried out by capillary gas chromatography with electron-capture and mass spectrometry detectors. The recoveries were determined by fortifying six different crops (apples, oranges, pears, tomatoes, lettuces and paprikas) with the pesticides studied (bromopropylate, chlorpyrifos methyl, cypermethryn, deltamethryn, fenarimol, fenvalerate, imazalil, lindane, permethryn, phentoate, procymidone, propiconazole and vinclozoline). Although, the data showed that the two extraction methods and both sorbents were able to isolate the pesticide residues from fruit and vegetables, the best results were obtained using MSPD with C18 which gave recoveries ranging from 70 to 105% and practical detection limits between 5.0 and 50.0 micrograms/kg for all the compounds. Ten of these pesticides have been detected in samples taken from Valencia markets, at levels of 0.02-20.50 mg/kg using the described methodology.

Carbon↗

Determination of five nitrobenzoic acids in groundwater by solid-phase extraction and liquid chromatography-mass spectrometry.

A method involving solid-phase extraction (SPE) and reversed-phase liquid chromatography-mass spectrometry (LC-MS) has been developed for determination, in groundwater, of nitrobenzoic acids associated with 2,4,6-trinitrotoluene production. Pre-concentration on a co-polymer-based SPE cartridge enabled quantitative extraction of the analytes from water. Investigation of negative ion electrospray and atmospheric-pressure chemical ionization mass spectrometry indicated the sensitivity of APCI was more than twice that of ESI. An 15N-labeled internal standard was used to achieve more accurate quantitation and mass assignment. Recovery was better than 80% when 10 mL water was extracted with the SPE cartridge. Combination of SPE with LC-MS analysis resulted in method detection limits of less than 5 microg L-1. The method has been used for analysis of groundwater samples collected from a site of a former ammunition plant. Contamination with nitrobenzoic acids was determined at microg L-1 levels.

Journal Article↗

Liquid chromatographic determination of sotalol in plasma and urine employing solid-phase extraction and fluorescence detection.

A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.

Chromatography, High Pressure Liquid↗

Solid-phase extraction of plasma vasopressin: evaluation, validation and application.

A new solid-phase extraction method using octyl-silica columns to extract vasopressin-like immunoreactivity from plasma has been developed. The extraction was followed by a radioimmunoassay on the vacuum-dried extracts, which were reconstituted in assay buffer. The total recovery of synthetic vasopressin was ca. 100%. Based on co-elution with synthetic vasopressin after separation by reversed-phase high-performance liquid chromatography of plasma extracts from normal Wistar and Brattleboro rats, and the cross-reactivity of the antiserum used in the radioimmunoassay system, the extracted material was found to be indistinguishable from authentic vasopressin. Unknown experimental samples were interpolated on a standard curve established in "zero" plasma (plasma derived from rats subjected to waterload) spiked with known amounts of synthetic vasopressin, and not on a standard curve established in assay buffer. The limit of detection was 1 fmol of vasopressin equivalent per millilitre. The intra- and inter-assay coefficients of variance were 10-16% and 16%, respectively. The procedure reliably showed that osmotic challenge and 24-h dehydration increased, whereas ethanol ingestion decreased vasopressin-like immunoreactivity plasma levels in the rat, compared with normally hydrated controls.

Animals↗

Poly(methyloctylsiloxane) immobilized on silica as a sorbent for solid-phase extraction of some pesticides.

A laboratory-made sorbent for solid-phase extraction (SPE) was obtained by thermal immobilization of poly(methyloctylsiloxane) (PMOS) onto silica. Cartridges packed with the new sorbent were used for the simultaneous determination of imazethapyr, nicosulfuron, diuron, linuron and chlorimuron-ethyl in water. These pesticides were separated and quantified using high-performance liquid chromatography with diode array detection (HPLC-DAD). The recoveries achieved with the laboratory-made PMOS cartridges were compared with those of some commercially available silica-based and polymer-based cartridges having C18, C8 and NH(2) pendant groups. Method validation using the laboratory-made sorbent was performed for the five pesticides at three fortifications levels (1x, 2x and 10x the limit of quantification of each pesticide). The laboratory-made PMOS cartridge has low cost preparation and showed good recoveries (72-111%) for all pesticides. Repeatability and intermediate precision were lower than 15%. Its performance was similar or even better, in some cases, than those of the commercial cartridges.

Chemical Fractionation↗

Investigation of matrix effects of urine on a molecularly imprinted solid-phase extraction.

This study investigates matrix effects on a molecularly imprinted solid-phase extraction (MISPE) method developed for the clean-up of diphenyl phosphate (a hydrolysis product of the commonly used flame retardant and plasticizer, triphenyl phosphate) in urine samples. The influence of potentially interfering compounds that naturally occur in urine was examined with respect to extraction recovery, repeatability and selectivity. The components tested were NaCl, urea, creatinine and hippuric acid. The imprinted polymer was prepared using 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate as crosslinker and a structural analogue of the analyte as the template molecule. The recovery of diphenyl phosphate from water standards was over 90% using MISPE, compared to less than 25% using a non-imprinted SPE (NISPE) counterpart. The selectivity of MISPE compared to NISPE was achieved in a wash step with a basic modifier in methanol. The recovery and repeatability of the MISPE method were affected most by NaCl in the tested concentrations, while urea, creatinine and hippuric acid had no significant influence. NaCl most likely weakens the binding during the loading of the sample. This effect could be suppressed by diluting the sample with a citrate buffer at pH 4.0.

Creatinine↗

Liquid chromatography-electrospray ionization isotope dilution mass spectrometry analysis of paraquat and diquat using conventional and multilayer solid-phase extraction cartridges.

The performance of alkyl-silica sorbent packed solid-phase extraction (SPE) cartridges and a mixed-mode, polymeric sorbent packed SPE cartridge (resin SPE cartridge) were evaluated for the sample preparation of paraquat and diquat in environmental water and vegetation matrices. Also the recoveries of the native and 2H-labeled paraquat and diquat were correlated to validate that the 2H-labeled species can be used for the isotopic dilution mass spectrometry (IDMS) analysis of paraquat and diquat. The results show that the extraction efficiency of alkyl-silica SPE is dependent on the carbon loading of the sorbent and deteriorates with an increasing sample pH. The resin SPE cartridge required no pH adjustment and showed excellent correlation between the native and 2H-labeled species, therefore, allowing us to develop the first liquid chromatography-electrospray ionization IDMS analytical method for the analysis of paraquat and diquat in environmental water and vegetation matrices. Method detection limits derived using standard EPA protocol were 0.2 and 0.1 microg/l for paraquat and diquat in water matrices, and 0.02 and 0.01 microg/g in vegetation matrices, respectively.

Calibration↗

Microscale solid-phase extraction system for explosives.

A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Porapak R. The extraction system consisted of two syringe pumps and several solenoid valves. Optimal detection limits were realized when the sample water flow-rate was maximally increased within the limits of the pump, 5-10 ml/min (despite exceeding the breakthrough threshold of the SPE microcolumn), and when the eluate volume collected from the column was minimized, <5 microl (despite very low recovery percentages).

Automation↗

Quantification of rosuvastatin in human plasma by automated solid-phase extraction using tandem mass spectrometric detection.

An assay employing automated solid-phase extraction (SPE) followed by high-performance liquid chromatography with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS) was developed and validated for the quantification of rosuvastatin (Crestor) in human plasma. Rosuvastatin is a hydroxy-methyl glutaryl coenzyme A reductase inhibitor currently under development by AstraZeneca. The standard curve range in human plasma was 0.1-30 ng/ml with a lower limit of quantification (LLOQ) verified at 0.1 ng/ml. Inaccuracy was less than 8% and imprecision less than +/-15% at all concentration levels. There was no interference from endogenous substances. The analyte was stable in human plasma following three freeze/thaw cycles and for up to 6 months following storage at both -20 and -70 degrees C. The assay was successfully applied to the analysis of rosuvastatin in human plasma samples derived from clinical trials, allowing the pharmacokinetics of the compound to be determined.

Chromatography, Liquid↗

Pyraflufen-ethyl residues in soil by solid phase extraction and high-performance liquid chromatography with UV detection.

Solid-phase extraction (SPE) procedure for cleanup followed by HPLC-UV method has been investigated for the determination of pyraflufen-ethyl residues in soil. The pesticide is extracted from the sample with acetone-water (80:20, v/v) and the extract is loaded onto an octadecyl (C(18)) column. The pesticide is eluted with acetonitrile and determined by HPLC with a UV detector. Using an acetone-water extraction followed by a C(18) cleanup, this method is characterized by recovery >90.1%, precision <5.8% RSD and sensitivity of 0.01 mg/kg. The proposed method has been successfully employed for the determination of the degradation dynamics of pyraflufen-ethyl in four agricultural soil samples under laboratory conditions.

Journal Article↗

Solid-phase extraction on alkyl-bonded silica gels in inorganic analysis.

Solid-phase extraction (SPE) is an effective tool for the preconcentration of trace elements and their separation from various sample constituents. Octadecyl and other alkyl-bonded silica gels are most widely used for these purposes. The fundamentals of the SPE of inorganic ions are reviewed and compared with those of related techniques (liquid-liquid extraction and reversed-phase liquid chromatography). The extraction of ions in the form of chelate compounds, inorganic salts solvated by neutral reagents, and ion-pair compounds is considered. Numerous applications of SPE to the separation and preconcentration of different elements and their species, including on-line combinations with instrumental determination techniques, are described and tabulated.

Journal Article↗

Determination of forchlorfenuron residues in watermelon by solid-phase extraction and high-performance liquid chromatography.

A method using solid-phase extraction for cleanup, followed by high-performance liquid chromatography with ultraviolet detection (HPLC/UV), was developed for the determination of forchlorfenuron residues in watermelon. The pesticide is extracted from the sample with acidic acetonitrile, and the extract is loaded onto a primary-secondary amine (PSA) column. The pesticide is eluted with acetone and determined by HPLC/UV. The PSA column was found to provide effective cleanup, removing the greatest number of sample matrix interferences. The acetonitrile extraction followed by the PSA cleanup provided recoveries of >95%, coefficients of variation (precision) of <10%, and sensitivity of 0.005 mg/kg, in agreement with the directives for method validation in residue analysis. The proposed method was successfully used to determine forchlorfenuron residue levels and dissipation rates in watermelon grown in an experimental greenhouse in Beijing, People's Republic of China.

Chromatography, High Pressure Liquid↗

Simultaneous analysis of amphetamine, methamphetamine, and 3, 4-methylenedioxymethamphetamine (MDMA) in urine samples by solid-phase extraction, derivatization, and gas chromatography/mass spectrometry.

A rapid and effective solid-phase extraction procedure using Bond Elute Certify bonded silica sorbent cartridges was adopted to extract amphetamine, methamphetamine, and 3,4-methylenedioxymethamphetamine (MDMA or Ecstasy) from urine samples. The extract was derivatized with trichloroacetic anhydride prior to gas chromatography/mass spectrometry (GC/MS) analysis with selected ion monitoring of the following ions: 190, 91, 188; 204, 91, 202; 162, 135, 202; 194, 123; and 211, 209 for the derivatized amphetamine, methamphetamine, MDMA, d5-amphetamine, and d9-methamphetamine, respectively. The first of the ions listed for each compound was used for quantitation. The compound d5-amphetamine was used as the internal standard for amphetamine, and d9-methamphetamine was used for methamphetamine and MDMA. Results showed a higher than 65% recovery and a reproducibility with less than a 5% coefficient of variation. When a sample size of 2 mL was used, the lowest detectable concentration was about 50 ng/mL, and a near-perfect fit can be obtained (within the 250 to 4000-ng/mL concentration range studied) using a second-order polynomial model.

3,4-Methylenedioxyamphetamine↗

Improved gas chromatography/mass spectrometry analysis of barbiturates in urine using centrifuge-based solid-phase extraction, methylation, with d5-pentobarbital as internal standard.

Effective solid-phase extraction, derivatization, and GC/MS procedures are developed for the simultaneous determinations of butalbital, amobarbital, pentobarbital, and secobarbital, using a deuterated pentobarbital (d5-pentobarbital) as the internal standard. Buffered (pH 7) urine samples were extracted with Bond Elute Certify II cartridge. Iodomethane/tetramethylammonium hydroxide in dimethylsulfoxide was used for methylation, while a HP 5970 MSD equipped with a 13 m J & W DB-5 column (5% phenyl polysiloxane phase) and the Thru-Put Target software package were used for GC/MS analysis and data processing. This protocol was found to be superior, in both chromatographic performance characteristics and quantitation results, over a liquid-liquid extraction procedure without derivatization using hexobarbital as the internal standard. Extraction recoveries observed from control samples containing four barbiturates range from 80% to 90%. Good one-point calibration data are obtained for all four barbiturates in the 50 to 3200 ng/mL range. Interestingly, the one-point calibration data for pentobarbital are inferior to the other three barbiturates--due to interference from the internal standard (d5-pentobarbital). The calibration data of pentobarbital are best described by a hyperbolic curve regression model. Precision data (% CV) for GC/MS analysis, over-all procedure, and day-to-day performance are approximately 2.0%, 6.0%, and 8.0%, respectively. With the use of a 2 mL sample size, the attainable detection limit is approximately 20 ng/mL.

Amobarbital↗

Carbon nanotubes as adsorbent of solid-phase extraction and matrix for laser desorption/ionization mass spectrometry.

A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 microL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized.

Adsorption↗

Solid phase extraction chromatography and NMR spectroscopy (SPEC-NMR) for the rapid identification of drug metabolites in urine.

The use of solid phase extraction onto disposable columns containing a C18 bonded silica gel provides a rapid and simple procedure for the removal of interfering endogenous components from urine samples containing drug metabolites prior to detection and identification by (1)H NMR spectroscopy. In addition, these columns can be used to retain and concentrate the compounds of interest, thus improving the effective sensitivity of the NMR detection method. Using simple step gradients chromatographic separations can be performed, and metabolites may be rapidly fractionated. This approach (solid phase extraction chromatography with NMR or SPEC-NMR) utilises the multiparametric metabolite detection facility of a Fourier transform NMR spectrometer to monitor a chromatographic separation, as such it has some of the beneficial properties of a directly linked liquid chromatography-NMR system without any of the disadvantages. Applications of the SPEC-NMR method in the investigation of drug metabolism are illustrated here by reference to excretion studies on the drugs ibuprofen, paracetamol, aspirin, oxpentifylline and naproxen.

Journal Article↗

Solid-phase extraction and high-performance liquid chromatography for therapeutic monitoring of haloperidol levels.

This laboratory has developed a simple and efficient solid-phase extraction method that is combined with a high-performance liquid chromatographic method for rapid and precise therapeutic monitoring of haloperidol (Haldol) blood levels. The solid-phase extraction utilizes a mixed bed column. Sensitivity of the chromatographic method is 0.5 ng/ml (1.3 nM) of drug in serum, and separations can be performed in a 15-min chromatographic run. Advantages of this approach include enhanced speed, sensitivity, and efficiency. A high level of sensitivity may be achieved because of the absence of interferences from other drugs, metabolites, or serum components.

Animals↗

Determination of ropivacaine in human plasma using highly selective molecular imprint-based solid phase extraction and fast LC-MS analysis.

A method for determining ropivacaine in human plasma using highly selective molecular imprint-based solid phase extraction and LC-MS analysis was developed. The imprinted extraction material was prepared using a structural analogue of ropivacaine as the template. The efficient sample cleanup achieved allowed single MS mode operation and analytical separation under isocratic conditions with a total separation time of less than two minutes. The absence of ion suppression was confirmed for both the m/z of ropivacaine and the m/z of the internal standard. The solid phase extraction protocol was optimised for elution of ropivacaine in a small volume of aqueous-rich solvent suitable for injection into a reversed phase LC-MS system. The final method measured trace levels of ropivacaine in human plasma with a limit of quantification of 2.5 nmol/L and interassay accuracy and precision of 101.7-104.4% and 2.1-7.2%, respectively.

Amides↗