Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SEALS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Relationships and bioaccumulation of chemical elements in the Baikal seal (Phoca sibirica).

Concentrations of Al, Ba, Cd, Cu, Fe, Mn, Mo, Si, Sr, Zn, Ca, K, Mg, Na and P in the livers of Baikal seal, plankton, zoobenthos, and fish, constituting the food sources for the seals, were determined by ICP-MS and ICP-AES. The accumulation of elements in the liver of seals, affected by internal and external (environmental) factors, was assessed by multidimensional (ANOVA, FA) and correlation analyses. FA has enabled identification of abiotic and biotic factors responsible for the accumulation of elements in the livers of Baikal seals. Significant influence of sex and development stage of the seals analysed on hepatic concentrations of some elements was found. The observed differences in element concentrations between pups, males and females could be attributable to the reproductive cycle of this species. ANOVA showed differences in concentrations of Fe, Zn, Cu and Cd in seals from the three separate basins of the lake. BMFs suggest biomagnification of Fe and Zn in the fish-seal trophic link.

Animals↗

Preliminary report of a prospective, randomized trial of underwater seal for spontaneous and iatrogenic pneumothorax.

BACKGROUND: Management of pneumothorax has traditionally been tube thoracostomy and -20 cm H2O suction. The purpose of our study was to determine if underwater seal in iatrogenic and spontaneous pneumothoraces is safe and efficacious and if small-caliber chest tubes are appropriate for routine use in pneumothorax. STUDY DESIGN: From April 2001 through October 2003 patients with iatrogenic or spontaneous pneumothorax were enrolled in this prospective, randomized trial. Small-bore catheters were inserted. Initial management was 1 hour -20 cm H2O suction, chest radiography, and randomization into -20 cm H2O suction, -10 cm H2O suction, or underwater seal. Tubes were discontinued at 48 hours if there were no pneumothoraces and no air leaks. Those with air leaks and recurrent pneumothoraces persisting 5 days underwent pleurodesis. The primary end point was successful chest tube removal at 48 hours. The secondary end point was need for pleurodesis. RESULTS: Twenty-nine patients were analyzed. Seven were randomized to -20 cm H2O suction, 11 to -10 cm H2O suction, and 11 to underwater seal. Most (59%, 17 of 29) chest tubes were successfully removed 48 hours after placement: 57% (4 of 7) after -20 cm H2O suction, 73% (8 of 11) after -10 cm H2O suction, and 45% (5 of 11) after underwater seal (p = 0.48). Seven (24%) required pleurodesis: 29% (2 of 7) after -20 cm H2O suction, 27% (3 of 11) after -10 cm H2O suction, and 18% (2 of 11) after underwater seal (p = 0.70). CONCLUSIONS: Early underwater seal appears to be safe for treating iatrogenic and spontaneous pneumothoraces. It can achieve comparable frequencies of early chest tube removal and avoidance of operation compared with traditional management. A larger, multi-institutional study should be performed to demonstrate that pneumothorax treatment can effectively incorporate small-caliber tubes and underwater seal.

Adolescent↗

Circumpolar pattern of mercury and cadmium in ringed seals.

Mercury (Hg) and cadmium (Cd) concentrations in ringed seal liver and kidney were compared from 11 locations across the Arctic, from Alaska, Canada, Greenland, Svalbard to the White Sea. Adult and sub adult seals were evaluated separately to account for age accumulations of Hg and Cd. Only recently (1995-2001) collected samples were included to minimize influence of changes over time. The Hg and Cd concentrations in ringed seal liver and kidney differed significantly among the studied locations. The Hg concentrations in liver of ringed seals was highest in the western Canadian Arctic locations, while Cd in liver was highest in the eastern Canadian and West Greenland locations. In general, Hg and Cd concentrations in liver and kidney were significantly higher in adult ringed seals than in sub adults and the circumpolar patterns were most pronounced in adult ringed seals. The Hg and Cd concentrations in kidney of ringed seals in general supported the geographical pattern found in livers although the coverage was more limited. The most likely explanation for the observed circumpolar pattern appears mainly to be related to natural geological differences in mineral (Hg and Cd) among regions.

Animals↗

Temporary luminal arteriotomy seal: II. Coronary artery bypass grafting on the beating heart.

BACKGROUND: This study assessed the feasibility of applying a temporary luminal arteriotomy seal during end-to-side coronary artery bypass grafting on the beating heart. METHODS: In 18 consecutive pigs, the left internal mammary artery was grafted to the left anterior descending coronary artery, and the arteriotomy was temporarily sealed luminally by a 200-microm-thick polyurethane seal. Endothelial denudation, medial necrosis, and intimal hyperplasia were measured quantitatively and compared with conventionally sutured anastomoses (n=4 pigs). RESULTS: Insertion and retrieval of the seal required 28+/-12 and 11+/-6 seconds, respectively. Including the arteriotomy, coronary artery occlusion was limited to about 80 seconds. The seal provided a bloodless arteriotomy in all anastomoses with unimpeded coronary artery blood flow. Endothelial denudation was limited to two thirds of the circumference of the coronary artery. No medial necrosis was found. Intimal hyperplasia at the suture line was small, although more pronounced when compared with conventionally sutured anastomoses. CONCLUSIONS: In off-pump, beating-heart coronary artery bypass grafting, the temporary luminal arteriotomy seal provided a bloodless arteriotomy with negligible obstruction to coronary artery blood flow, and with a minimum of arterial wall damage. It is conceivable that this seal may expand the indications for coronary surgical procedures without cardiopulmonary bypass.

Animals↗

Bioaccumulation profiles of polychlorinated biphenyls including coplanar congeners and possible toxicological implications in Baikal seal (Phoca sibirica).

Isomer specific concentrations of individual polychlorinated biphenyls (PCBs) including toxic non-ortho (IUPAC 77, 126, 169), mono-ortho (105, 118, 156) and di-ortho (137, 138, 153, 180) coplanar congeners were determined in the blubber of 40 Baikal seals (Phoca sibirica) and as their fish diet collected from Lake Baikal, Siberia. Residue levels of total PCBs in Baikal seals were noticeably high and comparable to those reported for seals from the North Sea, suggesting the recent usage of this compound in the watershed of Lake Baikal. Non-, mono-, and di-ortho coplanar congeners were also detected in Baikal seals and fish. An approach to estimate bioaccumulation profiles of PCB congeners revealed that the non-ortho PCBs, IUPAC 77, 126 and 169 seemed to be less persistent than other congeners. Furthermore, selective biotransformation of PCB congeners having either meta-para vicinal H atoms or both adjacent chlorinated meta-para and ortho-meta positions has been suggested. Comparison of 2,3,7,8-TCDD toxic equivalents (TEQ) of non-, mono- and di-ortho coplanar congeners in Baikal seals with those for other marine mammals suggested higher enrichment of mono-ortho congeners, particularly IUPAC 105 and 118, which contributed significantly to the total TEQs in Baikal seals. Results imply that the TCDD-like toxicity is relatively serious in Baikal seals, because of the enrichment of these toxic PCB congeners in tissues.

Journal Article↗

[Safety and efficacy of an early deambulation protocol after PTCA with an angio-seal device].

INTRODUCTION: In order to assess the efficacy and safety of an early deambulation (1-2 h) protocol after coronary angioplasty using the Angio-seal collagen plug, we analyzed a consecutive series of patients treated with this device versus a reference group treated with mechanical compression. PATIENTS AND METHODS: Two hundred and seven coronary angioplasty patients were included from February to August 2000. Ninety-eight were treated with mechanical compression and one hundred and nine with the Angio-seal collagen plug. All patients were followed at discharge and fifteen days after surgery. RESULTS: Eighty percent of the patients receiving the Angio-seal device achieved immediate hemostasis (< 1 min). In patients with mechanical compression hemostasis was achieved within 30 min in 68.3%, whereas 25.5% of patients required more than 40 min. First deambulation in the Angio-seal group was achieved within 2 h in 94.5% of the patients. The incidence of major complications was low in both groups (1 case in the Angio-seal group and 2 in the C-clamp group) without statistically significant differences. The Angio-seal group showed a lower incidence of overall vascular complications as compared to the C-clamp group (4.6% vs. 14.3%; p = 0.02). CONCLUSION: Following our protocol, an early deambulation strategy after coronary angioplasty with the use of the Angio-seal collagen plug was feasible, safe and efficacious.

Adult↗

Temperature dependence of membrane sealing following transection in mammalian spinal cord axons.

Using an in vitro sucrose-gap recording chamber, sealing of cut axons in isolated strips of white matter from guinea pig spinal cord was measured by recording the "compound membrane potential". This functional sealing was found to correlate well with anatomical resealing, measured by a horseradish peroxidase uptake assay. Near-complete functional and anatomical recovery of the axonal membrane occurred routinely within 60 min following transection at 37 degrees C in regular Krebs' solution. The rate of membrane potential recovery is exponential, with a time-constant of 20+/-5 min. The sealing process at 31 degrees C was similar to that at 37 degrees C, and was effectively blocked at 25 degrees C, under which condition most axons continued to take up horseradish peroxidase for more than 1h, and failed to substantially recover their membrane potential. Seventy-five percent of the cords transected at 40 degrees C had similar sealing behavior to those at 37 degrees C and 31 degrees C. The balance failed to seal the cut end. Two-dimensional morphometric analysis has shown that raising the temperature from 25 degrees C to above 31 degrees C significantly decreases axonal permeabilization to horseradish peroxidase (increases the sealing of transected ends) across all areas of a transverse section of spinal cord. Moreover, this enhancement of sealing exists across all axon calibers. Since severe cooling compromises membrane resealing, caution needs to be taken when hypothermic treatment (below 25 degrees C) is applied within the first 60 min following mechanical injury. In summary, we have found that at normal temperature (37 degrees C), nerve fibers repair their damaged membrane following physical injury with an hour. This is similar at mildly lower (31 degrees C) and relatively higher (40 degrees C) temperature, although some fibers tend to collapse under this febrile temperature. Moreover, severely low temperature (25 degrees C) hindered the repair of damaged membranes. Based on our study, caution is needed in treating spinal cord injury with low temperatures.

Animals↗

Rapid epithelial-sheet sealing in the Caenorhabditis elegans embryo requires cadherin-dependent filopodial priming.

BACKGROUND: During embryonic development, epithelia with free edges must join together to create continuous tissues that seal the interior of the organism from the outside environment; failure of epithelial sealing underlies several common human birth defects. Sealing of epithelial sheets in embryos can be extremely rapid, dramatically exceeding the rate of adherens junction formation by epithelial cells in culture or during healing of epithelial wounds. Little is known about the dynamic redistribution of cellular junctional components during such events in living embryos. RESULTS: We have used time-lapse, multiphoton laser-scanning microscopy and green fluorescent protein fusion proteins to analyze the sealing of the Caenorhabditis elegans epidermis in living embryos. Rapid recruitment of alpha-catenin to sites of filopodial contact between contralateral migrating epithelial cells, concomitant with clearing of cytoplasmic alpha-catenin, resulted in formation of nascent junctions; this preceded the formation of mature junctions. Surprisingly, upon inactivation of the entire cadherin-catenin complex, only adhesive strengthening between filopodia was reproducibly affected. Other ventral epidermal cells, which did not extend filopodia and appeared to seal along the ventral midline by coordinated changes in cell shape, successfully adhered in the absence of these proteins. CONCLUSIONS: We propose that 'filopodial priming' - prealignment of bundled actin in filopodia combined with the rapid recruitment of alpha-catenin from cytoplasmic reserves at sites of filopodial contact - accounts for the rapid rate of sealing of the embryonic epidermis of C. elegans. Filopodial priming may provide a general mechanism for rapid creation of adherens junctions during epithelial-sheet sealing in embryos.

Animals↗

Removal of chest tubes in children without water seal after elective thoracic procedures: a randomized prospective study.

BACKGROUND: Chest tubes are often placed in children after elective thoracic surgical procedures. Depending on surgeon preference, tubes can be pulled directly from suction or after a trial of water seal. Removal of the tube without water seal potentially allows earlier removal, decreased postoperative pain, and earlier discharge from the hospital. No randomized, prospective study has been performed to compare the two methods to determine whether omission of the water seal period is safe after elective thoracic surgery in children. STUDY DESIGN: This is a single-blinded, randomized study conducted between June 1998 and June 2000. Children undergoing elective, noncardiac, nonesophageal thoracic operations were placed into water seal or a nonwater seal groups. Groups were compared for development of pneumothorax or pleural effusion after chest tube removal. RESULTS: Fifty-two children participated in the study, with 28 in group I (suction) and 24 in group II (water seal). Operations included both pulmonary and nonpulmonary thoracic operations performed both thoracoscopically and open. No child developed a major pleural effusion after chest tube removal. Three children (11%) in group I and eight (33%) in group II developed pneumothorax. No child required reinsertion of the chest tube and all were successfully treated with observation and oxygen. There was no marked difference between the groups regarding development of pneumothorax, but the power of the study is low. CONCLUSIONS: A water seal trial is not necessary for safe removal of chest tubes in children undergoing elective surgery. Chest tubes can be removed safely and earlier when pulled directly from suction for both pulmonary and nonpulmonary thoracic pediatric procedures.

Chest Tubes↗

Effect of thickness on the sealing ability of some root canal sealers.

A fluid transport model study was used to evaluate the sealing ability of five root canal sealers, AH 26, Sealapex, Ketac Endo, Roth, and Kerr EWT, and a dental bonding agent at thicknesses of 0.05 mm (thin layer) and 0.3 mm (thick layer) with 270 standard human root sections obturated with sealer combined with standard gutta-percha cylinders. AH26 and Sealapex sealed more tightly in thick layers, whereas Ketac Endo, Johnson and Johnson Bonding Agent, Roth, and Kerr EWT sealed more tightly in thin layers. In thin layers J&J Bonding sealed more tightly than any other sealer tested. In thick layers AH 26 and Sealapex sealed more tightly than Ketac Endo and J&J Bonding Agent, and these sealed more tightly than Roth and Kerr EWT. These findings indicate that the thickness of the sealer layer significantly influences the sealing of a root canal filling and that the influence of thickness varies depending on the type of sealer.

Air↗

Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients.

BACKGROUND: It has been generally accepted that a higher airway seal pressure indicates adequate positioning of the laryngeal mask airway (LMA) in adult patients. The present study was undertaken to clarify whether a higher airway seal pressure correlates with an adequate positioning of the LMA in paediatric patients. METHODS: One hundred and eighty-one healthy children, aged 6-121 months, weighing 7.0-30.0 kg, managed with size 1.5-2.5 LMAs during elective surgery, were enrolled in this study. LMAs were inserted without using muscle relaxants, and patients breathed spontaneously during surgery. At the end of surgery, we documented oropharyngeal sealing pressure and fibreoptic aperture views of the LMA. We used a new fibreoptic score evaluating the anatomical relationship between LMA aperture and epiglottis: 1, the aperture view covered with anterior epiglottis completely, but the airway staying open; 2, anterior epiglottis seen for more than two-thirds of the aperture view in diameter; 3, anterior epiglottis seen for more than one-third, but less than two-thirds of the aperture view in diameter; and 4, anterior epiglottis seen for less than one-third of the aperture view in diameter. RESULTS: The oropharyngeal sealing pressures for each fibreoptic position, scores 1 to 4, were 17.0 +/- 6.4, 17.9 +/- 4.2, 20.1 +/- 7.3 and 17.1 +/- 6.1 cm H2O, respectively. There were no significant differences in sealing pressure between the four groups (P=NS). CONCLUSIONS: A higher airway seal is believed to be one of the clinical signs correlating with the correct position of an LMA. We found no relationship between oropharyngeal sealing pressure and LMA cuff position in paediatric patients.

Case-Control Studies↗

An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).

Alloys↗

Development of a magnetic fluid shaft seal for an axial-flow blood pump.

A rotating impeller in a rotary blood pump requires a supporting system in blood, such as a pivot bearing or magnetic suspension. To solve potential problems such as abrasive wear and complexity of a supporting system, a magnetic fluid seal was developed for use in an axial-flow blood pump. Sealing pressures at motor speeds of up to 8,000 rpm were measured with the seal immersed in water or bovine blood. The sealing pressure was about 200 mm Hg in water and blood. The calculated theoretical sealing pressure was about 230 mm Hg. The seal remained perfect for 743 days in a static condition and for 180+ days (ongoing test) at a motor speed of 7,000 rpm. Results of measurement of cell growth activity indicated that the magnetic fluid has no negative cytological effects. The specially designed magnetic fluid shaft seal is useful for an axial-flow blood pump.

Animals↗

Membrane sealing in frog skeletal-muscle fibers.

Self-sealing, not found in frog skeletal muscle fibers immersed in Ringer's solution, can be induced by solutions rich in calcium ion. Strontium replaced calcium on the sealing process, but magnesium did not. The sealing accomplished in high-calcium media was preserved in those fibers reimmersed in normal Ringer's solution. Measurements of the rate of sealing at different temperatures indicated that self-sealing induced by calcium has a high activation energy. Phospholipase C, an enzyme that hydrolyzes membrane phospholipids, produced a marked depression on the rate of sealing. Trypsin or chymotrypsin had no influence on the sealing process.

Animals↗

Calpain activity promotes the sealing of severed giant axons.

A barrier (seal) must form at the cut ends of a severed axon if a neuron is to survive and eventually regenerate. Following severance of crayfish medial giant axons in physiological saline, vesicles accumulate at the cut end and form a barrier (seal) to ion and dye diffusion. In contrast, squid giant axons do not seal, even though injury-induced vesicles form after axonal transection and accumulate at cut axonal ends. Neither axon seals in Ca2+-free salines. The addition of calpain to the bath saline induces the sealing of squid giant axons, whereas the addition of inhibitors of calpain activity inhibits the sealing of crayfish medial giant axons. These complementary effects involving calpain in two different axons suggest that endogenous calpain activity promotes plasmalemmal repair by vesicles or other membranes which form a plug or a continuous membrane barrier to seal cut axonal ends.

Animals↗

A 13-year follow-up of a comprehensive program of fissure sealing and resealing in Varkaus, Finland.

The objective of the study was to examine the coverage of the sealing program on first permanent molars (FPMs) and second permanent molars (SPMs) and first and second premolars (FSPMs), as well as to monitor the fate of the sealed teeth over time. All patients born in 1977 who had had regular check-ups in the Varkaus Health Center, Finland (n = 166) were included in the 1996 study. Data on the annual state of each tooth had been collected retrospectively since 1983. The coverage for the sealant program was 95%, 92%, and 6% of the FPMs, SPMs, and FSPMs, respectively. Out of the FPMs sealed at age 6 years, 28% were subjected to resealing, 13% developed occlusal, and 15% proximal caries during a 13-year follow-up period. From the SPMs sealed at age 11 years, 24% were subjected to resealing, 4% developed occlusal caries, and less than 2% proximal caries during the 9-year follow-up. None of the sealed FSPMs and only 1% of the non-sealed ones developed occlusal caries during the 9-year period. The mean DMF in the study population (n = 160) at age 12 years was 0.8 (n = 124), compared to a nation-wide mean value of 1.2. A large percentage of the FPMs and SPMs were sealed and then resealed during the study period. Although the study design lacked a control group for comparison, the lower caries rates of this study compared to the results of other studies with only a single application of sealants suggest a major role for resealing.

Bicuspid↗

A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries.

INTRODUCTION: The development of new energy sources for hemostasis has facilitated advanced laparoscopic procedures. Few studies, however, have documented the strength of the vessels sealed or the extent of surrounding lateral thermal injury, two important factors in maintaining hemostasis while preventing injury to surrounding structures. This study compared the burst pressure and extent of thermal injury of vessels sealed with the 5-mm laparoscopic PlasmaKinetics trade mark sealer (PK) (Gyrus Medical, Maple Grove, Minnesota) and the 5-mm laparoscopic LigaSure trade mark sealing device (LS) (Valleylab, Boulder, Colorado). METHODS: Arteries in three sizes (2-3 mm, 4-5 mm, and 6-7 mm) were harvested from domestic pigs. Eight to 17 specimens from each size were randomly sealed with the PK, and the same number with the LS. Burst pressures were measured in mm Hg. The extent of thermal injury, determined by coagulation necrosis, was measured microscopically in millimeters after staining the transected vessels with hematoxylin and eosin. Descriptive statistics, including means and standard deviations, are reported. Student's t-test and ANOVA were performed to determine significance (P <.05). RESULTS: The mean bursting pressures of the PK and the LS were equal in the 2-3 mm vessels (397 vs. 326 mm Hg, P =.49). The PK bursting pressures were significantly less than the LS in the 4-5 mm (389 vs. 573 mm Hg, P =.02) and the 6-7 mm groups (317 vs. 585 mm Hg, P =.0004). As vessel size increased, the PK was associated with significantly lower burst pressures, while the LS was associated with progressively higher burst pressures (P =.035). Thermal spread was not significantly different between the PK and the LS in the 2-3 mm (1.5 vs. 1.2 mm, P =.27), the 4-5 mm (2.4 vs. 2.4 mm, P =.79), or the 6-7 mm vessel size groups (3.2 vs. 2.5 mm, P =.32). Increasing vessel size, regardless of instrument used, was associated with increased thermal injury (P <.0001). CONCLUSION: The LS produces supraphysiologic seals with significantly higher bursting pressures than the PK in vessels ranging from 4 to 7 mm. The PK seals become progressively weaker while the LS seals increase in strength as the vessel size increases. Although thermal spread increases with vessel size, the degree of lateral thermal injury is no different between the two instruments.

Animals↗

A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients.

UNLABELLED: We measured pharyngeal mucosal pressures at six different locations on the laryngeal mask airway (LMA) and tested the hypothesis that the efficacy of the seal is not related to pharyngeal mucosal pressure. Twenty anesthetized, paralyzed adult patients were studied. Microchip sensors were attached to the size 5 LMA at locations corresponding to the lateral and posterior pharynx, the hypopharynx, the pyriform fossa, the base of tongue, and the oropharynx. Mucosal pressures and airway sealing pressures were recorded during inflation of the cuff from 0 to 40 mL in 10-mL increments. The highest mean mucosal pressure was in the oropharynx (26 cm H2O), and the lowest was in the posterior pharynx (2 cm H2O). Mucosal pressures increased with increasing intracuff pressure and cuff volume, but the rate of increase varied among locations. Airway sealing pressure increased with increasing intracuff volume from 0 to 10 mL (P < 0.0001) and 10 to 20 mL (P = 0.0001), was unchanged from 20 to 30 mL, and decreased from 30 to 40 mL (P = 0.005). The airway sealing pressure was higher than pharyngeal mucosal pressure until the intracuff volume was > or =30 mL. There was no correlation between mucosal pressures and airway sealing pressure at any location. We conclude that the efficacy of the seal is not related to pharyngeal mucosal pressure. Pharyngeal mucosal pressures are generally lower than those considered safe for the tracheal mucosa during prolonged intubation. IMPLICATIONS: We measured pharyngeal mucosal pressures at six different locations on the laryngeal mask airway and showed that the efficacy of the seal is not related to pharyngeal mucosal pressure. Pharyngeal mucosal pressures are generally lower than those considered safe for the tracheal mucosa during prolonged intubation.

Adult↗