Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Occurrence of Two Resin Acid-Degrading Bacteria and a Gene Encoding Resin Acid Biodegradation in Pulp and Paper Mill Effluent Biotreatment Systems Assayed by PCR.

> Abstract We examined the distribution of two dehydroabietic acid-degrading bacteria, Pseudomonas abietaniphila BKME-9 and Zoogloea resiniphila DhA-35, in biotreatment systems for pulp and paper mill effluents (PPMEs) using PCR assays. These two bacteria were first isolated from two PPME biotreatment systems and can degrade both dehydroabietic acid (DhA) and other abietane resin acids. We also examined the distribution of a catabolic gene, ditA1, encoding the alpha subunit of an aromatic ring-hydroxylating dioxygenase involved in DhA degradation by BKME-9. PCR primers specific for the 16S rDNA of BKME-9 and of DhA-35 and specific for ditA1 were used. Among 3 laboratory- and 17 full-scale PPME biotreatment systems, 10 contained phylotype BKME-9, 3 contained phylotype DhA-35, and 11 contained ditA1, indicating the wider distribution of phylotype BKME-9 than of phylotype DhA-35. Both phylotype BKME-9 and ditA1 were detected in the biotreatment system from which BKME-9 was originally isolated in 1994, suggesting the persistance of BKME-9 in that biotreatment system. The detection limit of the PCR assay was one cell per PCR reaction, which corresponds to one BKME-9 cell per 6 x 10(7) total sludge bacteria. A competitive PCR assay indicated that ditA1 ranged from 51 to 250 copies/mg of dry biomass. BKME-9 appears to contribute to the biodegration of resin acids in some PPME biotreatment systems. Using degenerate PCR primers and touchdown PCR, we obtained from our DhA-degrading strain collection six DNA sequences putatively homologous to that of ditA1. Cluster analysis of these DNA sequences suggests that ditA1 encodes a representative of a novel class of dioxygenase enzymes.http://link.springer-ny.com/link/service/journals/00248/bibs/38n2p114.html

Journal Article↗

A random clinical trial study to assess the efficiency of topical applications of podophyllin resin (25%) versus podophyllin resin (25%) together with acyclovir cream (5%) in the treatment of oral hairy leukoplakia.

OBJECTIVE: The objective of this study was to assess the efficiency of topical applications of podophyllin resin (25%) (P) versus podophyllin resin (25%) together with acyclovir cream (5%) (PA) in the treatment of oral hairy leukoplakia (OHL) in accordance with the following criteria: (1) number of applications necessary for the total clinical resolution of OHL; (2) correlation between the decrease of lesion size and the number of applications; (3) total clinical resolution of OHL; and (4) clinical reevaluation 12 months after the end of treatment. STUDY DESIGN: Forty-six OHLs were treated with P (P group) or with PA (PA group). Applications were performed weekly. Student t, Fisher exact, and Pearson correlation tests were used for statistical analysis. RESULTS: All 24 lesions from the PA group presented total clinical resolution while 4 lesions from the P group did not. The P group required up to 25 applications performed weekly while the PA group required up to 18. Observed was a negative significant association between the size of the lesions and the number of applications performed weekly in the PA group. CONCLUSIONS: The present study demonstrated the following: (1) P and PA topical treatments presented a similar average number of applications performed weekly; (2) both groups showed the same clinical response at 12 months post-therapy; and (3) PA presented a 100% clinical resolution and a continuous decrease in OHL size over the course of weekly applications.

Acyclovir↗

Long-term quantification of the release of monomers from dental resin composites and a resin-modified glass ionomer cement.

This study quantified the release of monomers from polymerized specimens of four commercially available resin composites and one glass ionomer cement immersed in water:ethanol solutions. Individual standard curves were prepared from five monomers: (1) triethylene glycol dimethacrylate (TEGDMA), (2) 2-hydroxy-ethyl methacrylate (HEMA), (3) urethane dimethacrylate (UDMA), (4) bisphenol A glycidyl dimethacrylate (BISGMA), and (5) bisphenol A. The concentration of the monomers was determined at Days 1, 7, 30, and 90 with the use of electrospray ionization/mass spectrometry. Data were expressed in mean micromol per mm(2) surface area of specimen and analyzed with Scheffe's test (p<0.05). The following monomers were found in water: monomers (1) and (2) from Delton sealant, monomer (5) from ScotchBond Multipurpose Adhesive and Delton sealant, monomer (3) from Definite and monomer (4) from Fuji II LC, ScotchBond Multipurpose Adhesive, Synergy and Definite. All these monomers increased in concentration over time, with the exception of monomer (1) from Delton sealant. Monomers (3) and (5) were found in extracts of materials despite their absence from the manufacturer's published composition. All monomers were released in significantly higher concentrations in water:ethanol solutions than in water. The greatest release of monomers occurred in the first day. The effect of the measured concentrations of monomers (1-5) on human genes, cells, or tissues needs to be considered with the use of a biological model.

Acrylic Resins↗

Marginal integrity of different resin-based composites for posterior teeth: an in vitro dye-penetration study on eight resin-composite and compomer-/adhesive combinations with a particular look at the additional use of flow-composites.

OBJECTIVE: To determine improvements in marginal adaptation of resin-based composite restorative systems by means of flow-composites (Solitaire 2/Gluma Solid Bond, Solitaire 2/Flow Line/Gluma Solid Bond, Point 4/Optibond Solo Plus, Point 4/Revolution/Optibond Solo Plus) and to determine the equality of simplified bonding systems (Solitaire 2/Gluma Comfort Bond, Tetric Ceram/Tetric Flow/Excite, Dyract AP/Prime & Bond NT/NRC, Pertac II/Prompt-L-Pop) in marginal gap formation. METHODS: The marginal dye penetration (2% methylene-blue) was investigated separately for the approximal boxes of Class II mod-cavities with one cervical margin of the approximal box within enamel, the other within cementum. The surface analysis determined the percentage of dye-penetrated cervical and lateral margins of the approximal boxes, while the in depth investigation reported the mean dye penetration (mm) at both different cervical margins. RESULTS: After thermocycling (5000 x , 5-55 degrees C) the percentage of dye penetration at the cervical cementum margins ranged from 16.5 +/- 5.9% (Solitaire/Flow Line/Gluma Solid Bond) to 82.8 +/- 5.7% (Pertac II/Prompt L-Pop), for the cervical enamel margins from 10.1 +/- 5.2% (Dyract AP/NRC/P & B NT) to 72.7 +/- 7.9% (Pertac II/Prompt L-Pop), and for the lateral enamel margins of the approximal boxes from 4.8 +/- 2.3% (Dyract AP/NRC/P & B NT) to 53.9 +/- 6.8% (Pertac II/Prompt L-Pop). In the in-depth dye penetration investigation the mean dye penetration ranged from 0.2 +/- 0.2 mm (Point 4/Revolution/Optibond Solo Plus) to 1.7 +/- 0.2 mm (Pertac II/Prompt L-Pop) at the cementum margins. At the enamel margins only Pertac II/Prompt L-Pop and Solitaire 2/Gluma Solid Bond showed mean in depth dye-penetrations deeper than 0.1 mm. SIGNIFICANCE: Pertac II/Prompt-L-Pop showed a statistically significant (significance level alpha = 0.05, Wilcoxon test) higher percentage of dye-penetrated margins than most of the other restorative systems.

Compomers↗

Resin content in cement liquids of resin-modified glass ionomers.

Qualitative and quantitative analyses were conducted on four kinds of resin-modified glass ionomer (RMGI) cement liquids, LC, LC II, LC III (hereinafter referred to as LCs) and VM, using HPLC and laser Raman spectroscopic methods. HPLC revealed that among the RMGI liquids LCs contain 31-32% HEMA (2-Hydroxyethyl methacrylate), and VM contains 18% of the same. The composition of RMGI cement liquids varied significantly between manufacturers. In Raman spectroscopic analyses, the spectra of liquids of various ratios of polyacrylic acid and HEMA were measured, and calculations were made on the peak intensity ratios of C=C stretch vibration to C=O stretch vibration, common in both HEMA and polyacrylic acid. The composition ratio of polycarboxylic acid to HEMA of commercial glass ionomer cements was assessed by the regression curve generated by a combination of peak intensity ratios and composition ratios. In addition, Raman spectroscopy was able to identity the differences in form of the methacryloyloxy group.

Carboxylic Acids↗

Evaluation of aerobic Bactec 6A non-resin- and 16A resin-containing media for the recovery of microorganisms causing peritonitis.

Recovery of microorganisms causing peritonitis in patients on continuous ambulatory peritoneal dialysis (CAPD) continues to be problematic. To date, there is no universally accepted protocol. We prospectively analyzed 430 peritoneal effluent specimens by three protocols: (a) 3 ml of effluent was centrifuged and the pellet plated onto blood and MacConkey agars and into thioglycolate broth (routine method), (b) 3 ml of each was inoculated at the bedside into Bactec 6A aerobic and 16A aerobic resin-containing media, and (c) 3 ml of each was inoculated in the laboratory into Bactec 6A and 16A media. Of the peritoneal effluent specimens, 104 (24%) had microorganisms recovered; 63 were positive by the routine method compared with 86 (P < .001) by bedside-inoculated 16A. Bedside-inoculated 16A (86) recovered more microorganisms than bedside-inoculated 6A (70) (P < .05). Laboratory-inoculated 16A (78) recovered more organisms than the routine method (63) (P < .05). Of 42 positive peritoneal effluent specimens delayed in transit > or = 1 day, 23 were positive by the routine method compared with 34 bedside inoculated 16A (P < .01) and 30 laboratory-inoculated 16A (P > .114). Bedside-inoculated 16A media is superior to the routine method for the recovery of microorganisms causing peritonitis in CAPD patients.

Anti-Bacterial Agents↗

Allergic contact dermatitis to bisphenol-A-glycidyldimethacrylate (BIS-GMA) dental resin associated with sensitivity to epoxy resin.

A patient presented with recurrent facial dermatitis associated with dental work. Dermatology referral identified the cause as allergic contact dermatitis to the epoxy acrylate BIS-GMA. Occupationally-induced allergic contact dermatitis to epoxy resin was also demonstrated. A structurally distinct aliphatic acrylate was successfully substituted. Contact sensitivity to BIS-GMA is reviewed and the potential for epoxy sensitive patients to cross-react to BIS-GMA is discussed.

Bisphenol A-Glycidyl Methacrylate↗

Resin glycosides. XXI. Tuguajalapins I-X, the resin glycosides having long-chain fatty acid groups from the root of Merremia hungaiensis.

Ten resin glycosides (jalapins) named tuguajalapins I-X were isolated from the root of Merremia hungaiensis. Their structures have been determined on the bases of chemical and spectral data. Unlike the jalapins so far reported, all of their acyl groups consist of two or three long-chain fatty acids, that is, palmitic, stearic and/or arachidic acids.

Carbohydrate Sequence↗

Immunohistochemistry on resin sections: a comparison of resin embedding techniques for small mucosal biopsies.

We have modified resin embedding methods to provide optimal information from endoscopic biopsies. Mucosal biopsies were fixed either in buffered formalin and processed for embedding in Araldite or in acetone containing protease inhibitors and embedded in glycol methacrylate (GMA). GMA embedding generated an immunophenotypic profile similar to that obtained in frozen sections while yielding far superior morphology and greater numbers of sections from small biopsies. The phenotypic markers included those for T cells, macrophages, mast cells, eosinophils and neutrophils. We have also demonstrated collagens, cell adhesion molecules and integrin molecules. Sections of similar quality were obtained with Araldite but the repertoire of antibodies was restricted to those which can be applied to formalin fixed, paraffin embedded tissues. We suggest that for optimal results, small biopsies to be subjected to immunochemistry are fixed in acetone at -20 C with the inclusion of protease inhibitors and embedded in GUIA with careful temperature control.

Biopsy↗

The adhesion mechanism of dental adhesive resin to the alloy. Adhesive ability of dental adhesive resin to the cleaned metal surface obtained by hydrogen gas reduction method.

With the cleaned metal surface without passive film or an oxide layer, chromium, cobalt, and iron show excellent bonding strength, indicating values similar to 18-8 stainless steel. Therefore the existence of a passive film and oxide layer at the interface metal/resin is not essential for metal-resin bonding. The adhesive ability decreases in the order: Cr congruent to Co congruent to Fe greater than Cu greater than Ag greater than Au congruent to Ni greater than Pt greater than Pd.

Acrylic Resins↗

[Investigations in Bioavailability of resinates as peroral retard drug dosage forms. Part 1: Pharmaceutical availability of dihydrocodein-resinates (author's transl)].

The dissolution rate constants of dihydrocodein in two retard drug dosage forms based on synthetic ion exchange resin were determined with four dissolution methods. The usage of the flow cell, rotationsdisk method and half-change method with a new dissolution model gave comparable results. Using the paddle apparatus the dissolution is very quick. There is only a small influence on the dissolution rate by the pH. A higher ionic strength of the dissolution medium increases the dissolution rate.

Biological Availability↗