Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Quartz”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Biomimetic piezoelectric quartz sensor for caffeine based on a molecularly imprinted polymer.

A piezoelectric quartz sensor coated with molecularly imprinted polymer (MIP) for caffeine was developed. The MIP was prepared by co-polymerizing methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of azobis(isobutyronitrile) as initiator, caffeine as template molecule, and chloroform as solvent. The MIP suspension in polyvinyl chloride/tetrahydrofuran (6:2:1 w/w/v) solution was spin coated onto the surface of the electrode of a 10 MHz AT-cut quartz crystal. The sensor exhibited a linear relationship between the frequency shift and caffeine concentration in the range of 1 x 10(-7) mg mL(-1 )up to 1 x 10(-3) mg mL(-1) [correlation coefficient ( r)=0.9935] in a stopped flow measurement mode. It has a sensitivity of about 24 Hz/ln(concentration, mg mL(-1)). A steady-state response was achieved in less than 10 min. The performance characteristic of the sensor shows a promising and inexpensive alternative method of detecting caffeine. Surface studies were carried out for the reagent phase of the sensor using SEM, AFM, and XPS analysis in order to elucidate the imprinting of the caffeine molecule. The SEM micrograph, AFM image, and XPS spectra confirmed the removal of caffeine by Soxhlet extraction in the imprinting process and the rebinding of caffeine to the MIP sensing layer during measurement.

Biomimetics↗

Quartz glass pipette puller operating with a regulated oxy-hydrogen burner.

Quartz glass electrodes are superior to conventional glass electrodes for low-noise recording. They have better electrical characteristics and hydrophobic surfaces which resist creeping of salt solutions. We used oxy-hydrogen heating with program-controlled gas pressure to melt quartz glass capillaries. Usually, the relative wall thickness (the quotient of the outer and inner diameters do/di) of capillaries is, at best, maintained up to the electrode tip. If tips with thicker walls can be produced, coating and other surface treatments can be avoided. We found that programmed heating periods without pull allowed an fivefold increase of do/di in the tip region. Since do/di is inversely proportional to input capacity, the recording noise was minimized and became insignificant relative to amplifier and holder noise. A sample patch-clamp recording is shown.

Animals↗

Immunoassays at a quartz-liquid interface: theory, instrumentation and preliminary application to the fluorescent immunoassay of human immunoglobulin G.

The theoretical basis and instrumental requirements of an optical detection technique for monitoring antibody-antigen reactions at a quartz-liquid interface are described. The antibody is covalently immobilized on the optical surface of a planar, fused-quartz waveguide and reacted with antigen solution. A light beam is internally reflected within the waveguide and penetrates into the solution only a fraction of the wavelength of the incident light. This is the evanescent wave which interacts optically with the growing number of antigen-antibody complexes but minimally with the bulk solution. A two-site immunofluorescent assay for human IgG measurement is described using fluorescein as the label. The assay detection limit is approximately 0.8 micrograms/ml and individual fluorescence measurements are completed within 10 min. It is expected that this evanescent wave immunoassay should have wide applicability in both routine and research fields.

Antigen-Antibody Complex↗

Quartz micropipettes for intracellular voltage microelectrodes and ion-selective microelectrodes.

We find that quartz is better than borosilicate glass as a material for micropipettes for certain microelectrode applications, including ion-selective microelectrodes of the liquid membrane type. Details are given of a graphite heating element that can be mounted on a standard microelectrode puller and used for making quartz micropipettes. A novel method of silanizing micropipettes is described. Experience with a novel miniature beveller that is fitted on a microscope stage is reported.

Electrophysiology↗

Immobilization of immunoglobulin on a quartz surface by BrCN without loss of antigen binding capability.

BrCN-activated quartz was used for the immobilization of monoclonal immunoglobulins. BrCN-activated quartz keeps its ability to quantitatively bind immunoglobulins for at least 8 h. The surface density of the immobilized immunoglobulins was 100 ng cm-2 and they were found to retain their ability to bind antigen in a molar ratio of 1:2 for not less than three months.

Antigen-Antibody Reactions↗

Immunoassay principle based on exchange reactions: investigations on agarose gel and silanized quartz.

Preliminary studies of a new immunoassay principle based on exchange reactions is reported. Exchange of 125I-labelled insulin with unlabelled insulin from immobilized monoclonal antibodies was investigated. From antibody immobilized on a gel substrate the tagged insulin was exchanged according to a first-order process. With antibody immobilized on a quartz substrate by two different methods, the kinetics was changed dramatically, probably because of the non-specific interaction between the ligand and the surface. The recorded adsorption isotherms could not be described by the Langmuir adsorption equation, and a model allowing for non-specific adsorption of the ligand was developed. This model gave a satisfactory fit to the experimental data, allowing computation of adsorption parameters. It is concluded that even the best method used to immobilize receptors on quartz is not adequate for an exchange assay to be made. However, this coating method may lead to more sensitive receptor-based assays of more conventional type.

Adsorption↗

A biosensor for estrogenic substances using the quartz crystal microbalance.

This article describes a biosensor that detects estrogenic substances using a quartz crystal microbalance with a genetically engineered construct of the hormone-binding domain of the alpha-estrogen receptor. The receptor was immobilized to a piezoelectric quartz crystal via a single exposed cysteine, forming a uniform orientation on the crystal surface. Our results illustrate that this sensor responds to a variety of ligands that are known to bind to the estrogen receptor. No response was observed for nonbinding substances such as testosterone and progesterone. The sensitive response of this biosensor to estrogenic substances results from changes in the structural rigidity of the immobilized receptor that occurs with ligand binding. Agonist and antagonist show different responses.

Biosensing Techniques↗

Immobilization of bovine serum albumin as a sensitive biosensor for the detection of trace lead ion in solution by piezoelectric quartz crystal impedance.

A biosensor based on bovine serum albumin (BSA) for the detection of lead (Pb(2+)) ion was developed and characterized. BSA was immobilized onto a colloidal Au-modified piezoelectric quartz crystal (PQC) as a biosensor for the detection of Pb(2+) ion by piezoelectric quartz crystal impedance (PQCI). Calibration curves for the quantification of Pb(2+) ion showed excellent linearity throughout the concentration range from 1.0 x 10(-7) to 3.0 x 10(-9)mol/L. The interaction between the Pb(2+) ions and the sensor chip is influenced significantly by the pH of the reaction buffer, and the optimal pH for the experiment was 5.4. Under the optimal conditions, the detection limit of 1.0 x 10(-9)mol/L for Pb(2+) was obtained. Kinetic parameters of the Pb(2+)-BSA interactions were also determined by using this chip. The sensor chip could be regenerated for use by dipping in the ethylenediaminetetraacetic acid (EDTA) solution for approximately 2h, and the chip was used to detect Pb(2+) ion for eight times without obvious signal attenuation.

Biosensing Techniques↗

Interaction analysis of chimeric metal-binding green fluorescent protein and artificial solid-supported lipid membrane by quartz crystal microbalance and atomic force microscopy.

Non-specific adsorption and specific interaction between a chimeric green fluorescent protein (GFP) carrying metal-binding region and the immobilized zinc ions on artificial solid-supported lipid membranes was investigated using the quartz crystal microbalance technique and the atomic force microscopy (AFM). Supported lipid bilayer, composed of octanethiol and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine/1,2-dioleoyl-sn-glycero-3-[N-(5-amino-1-carboxypentyl iminodiacetic acid)succinyl] (NTA-DOGS)-Zn2+, was formed on the gold electrode of quartz resonator (5 MHz). Binding of the chimeric GFP to zinc ions resulted in a rapid decrease of resonance frequency. Reversibility of the process was demonstrated via the removal of metal ions by EDTA. Nanoscale structural orientation of the chimeric GFP on the membrane was imaged by AFM. Association constant of the specific binding to metal ions was 2- to 3-fold higher than that of the non-specific adsorption, which was caused by the fluidization effect of the metal-chelating lipid molecules as well as the steric hindrance effect. This infers a possibility for a further development of biofunctionalized membrane. However, maximization is needed in order to attain closer advancement to a membrane-based sensor device.

Adsorption↗

Electrochemical piezoelectric quartz crystal impedance study on the interaction between concanavalin A and glycogen at Au electrodes.

The carbohydrate research has emerged as a "new frontier" in chemical/biological field. The binding of lectin with carbohydrate is one of the important courses of life activities. The report studies concanavalin A (Con A)-glycogen interaction on gold electrode surfaces by electrochemical piezoelectric quartz crystal impedance (EPQCI) method. The piezoelectric quartz crystal (PQC) parameters, resonant frequency shift (Deltaf(0)) and the motional resistance change (DeltaR(1)), and the electrochemical impedance (EI) parameters, electrolyte resistance change (DeltaR(s)) and the double layer capacitance change (DeltaC(s)), were measured and discussed simultaneously. Two methods were adopted for measuring the Con A-glycogen association. Based on EPQCI measurement during Con A reaction with glycogen adsorbed on Au electrode, association constant K(a) and the amount of the binding sites s calculated are 1.48 x 10(6) M(-1) and 4.09, respectively. Based on single PQC measurement of glycogen reaction with Con A assembled on Au electrode, K(a) was estimated to be 1.26 x 10(6) M(-1).

Biosensing Techniques↗

Molecularly imprinted ligand-exchange recognition assay of glucose by quartz crystal microbalance.

Molecular imprinted polymers (MIP) as a recognition element for sensors are increasingly of interest and MIP-quartz crystal microbalance (QCM) have started to appear in the literature. In this study, we have combined quartz crystal microbalance with MIP to prepare a sensor using the ability of glucose to chelate of copper (II) ion of methacrylamidohistidine (MAH) monomer to create ligand exchange (LE) assembled monolayer which is suitable for glucose determination. The study includes the measurement of binding interaction of molecularly imprinted QCM sensor via ligand interaction, investigation of the pH effect on frequency shift and recognition selectivity studies of glucose-imprinted polymer with respect to methyl-alpha-d-glucopyranoside and sucrose. Bmax (number of binding sites) and K(D) (dissociation constant of the metal-chelate copolymer) were also calculated using Scathard plot and the detection limit was found as 0.07 mM. MIP showed higher glucose-binding affinity than a well-known glucose binding protein, conconavalin A.

Copper↗

Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces.

A recently developed variant of quartz crystal microbalance (QCM) called QCM-with dissipation monitoring (QCM-D) allows simultaneous and simple measurements of changes in adsorbed mass as well as the viscoelastic property (D-factor) of deposited protein layers on the sensor surface. We have taken the QCM-D technology a step further and demonstrated its advantages in the study of protein assembly as a consequence of surface induced immune complement activation, or contact activated blood coagulation. In the present study we have continued our QCM-D investigations of surface assembly of fibrin clot formation and complement activation and incubated differently modified quartz sensor surfaces in blood plasma and sera. Polymer surfaces used were spin-coated polyethylene, poly(ethylene terephtalate), poly(methylmetacrylate) and poly(dimethylsiloxane). Also used were sputtered titanium and heparin grafted surfaces. In this investigation we found that we could describe the surface induced coagulation with four independent parameters: (1) Time of onset of coagulation, (2) fibrin deposition rate, (3) total frequency shift at stable plateau, and (4) fibrin clot density. The most important finding was that the blood plasma clot density can be assessed with the use of D determinations and that the clot density varied significantly with the chemical composition of the surface. However, the D-factor did not give any new analytical information about the possible complement activation mechanisms. Nevertheless, the QCM-D was found to be a reliable tool for the analysis of surface induced complement activation. We also compared the QCM-D technique with traditional enzyme immuno assay (EIA) measurements of soluble products from the surface activation of the complement and coagulation systems. We found that the results from EIA and QCM-D measurements corresponded well for the complement activation but not for the coagulation, probably due to the biological complexity of the coagulation system.

Adsorption↗

Study of real-time lectin-carbohydrate interactions on the surface of a quartz crystal microbalance.

A quartz crystal microbalance (QCM) biosensor system for lectin-carbohydrate interactions has been developed. Yeast mannan was immobilised on polystyrene-coated quartz crystals, and interactions tested with the lectin concanavalin A (Con A). The biosensor could be easily operated, where mannan immobilisation and all binding analyses were performed in real-time using a flow-through system. The apparent binding constant for yeast mannan to Con A was estimated to be 0.4 microM, well in accordance to reported literature values. In addition, the effective concentration values (EC50-values) for a series of mannose/mannoside ligands, acting as competitors to the mannan/Con A interaction, were determined to range from 0.18 to 5.3 mM, in good correlation with a related enzyme-labelled lectin assay (ELLA) protocol.

Biosensing Techniques↗

Molecularly imprinted thin film self-assembled on piezoelectric quartz crystal surface by the sol-gel process for protein recognition.

A novel method of combining sol-gel and self-assembly technology to prepare a human serum albumin (HSA)-imprinted film on the surface of piezoelectric quartz crystal (PQC) Au-electrode modified with thioglycolic acid was described in this paper. The imprinting process was characterized by using the piezoelectric quartz crystal impedance (PQCI) technique and electrochemical impedance technique. Scanning electron microscope (SEM) was employed to characterize the surface morphology of the resultant imprinted film. The piezoelectric technique and electrochemical impedance technique were also employed to investigate the binding performance of the sol-gel-imprinted film with the template protein. The results showed that the imprinted PQC film can give selective recognition to the template protein. The effects of salts and solvents on the binding capacity of the imprinted film with protein were discussed in detail. Other influencing factors (temperature and pH) have also been investigated. This self-assembly sol-gel imprinting technique was proved to be an alternative method for the preparation of biomacromolecule-imprinted thin film.

Adsorption↗

Series quartz crystal sensor for remote bacteria population monitoring in raw milk via the Internet.

A remote monitoring system based on a piezoelectric quartz crystal (SPQC) sensor was developed for the determination of the bacteria population in raw milk. The system employs the Windows XP server operating system, and its programs for data acquisition, display and transmission were developed using the LabVIEW 7.1 programming language. The circuit design consists of a circuit with a piezoelectric quartz crystal (SPQC) and a pair of electrodes. This system can provide dynamic data monitoring on a web-page via the Internet. Immersion of the electrodes in a cell culture with bacteria inoculums resulted in a change of frequency caused by the impedance change due to microbial metabolism and the adherence of bacteria on the surface of the electrodes. The calibration curve of detection times against density of bacteria showed a linear correlation coefficient (R(2) = 0.9165) over the range of 70-10(6) CFU ml(-1). The sensor could acquire sufficient data rapidly (within 4 h) and thus enabled real-time monitoring of bacteria growth via the Internet. This system has potential application in the detection of bacteria concentration of milk at dairy farms.

Animals↗

Uncoated quartz resonator as a universal biosensor.

We studied dynamic processes in drying drops of model protein-salt solutions, using an uncoated quartz resonator as a biosensor. To measure these processes we developed a method based on recording the dynamics of the Acoustic-Mechanical Impedance (AMI) of a drop as it dried on the surface of a quartz resonator oscillating at a resonant frequency of 60 kHz. The aim of this work was to highlight the role of some components of serum in self-organization processes. Human serum albumin (HSA), fibronectin (Fn), immunoglobulin G (IgG), immunoglobulin M (IgM), bovine serum albumin (BSA), sodium chloride (NaCl), Potassium Chloride (KCl), and nonionic surfactant O(CH(2)CH(2))(n)CH(2)CH(2)OH were used as components of the tested solutions. It was shown that dynamics of the AMI in drying drops were closely related to liquid composition. This approach allowed us to distinguish with good accuracy solutions in which one or more components (proteins or salts) were replaced by other components with the same mass concentration. We assumed that these differences were due to different surface properties and native functions of proteins, and different positions of salts in the Hofmeister line. Our preliminary work demonstrated that the dynamics of phase transitions in drying drops of serum could be used as an informative parameter for medical diagnostics. In this study, we highlight some positions in this cause-effect chain.

Biosensing Techniques↗

Surface charge and adsorption from water onto quartz sand of humic acid.

The surface charge of humic acid under different conditions of ionic strength, pH, and the presence of various cationic ions (Cu(2+), Zn(2+), Ba(2+), and Ca(2+)) was determined by a titration method using a cationic polyelectrolyte as titrant. Adsorption isotherms in batch experiments of the polymer from water onto quartz sand were determined at 20 degrees C, 40 degrees C, and 60 degrees C and under different conditions of ionic strength, pH, and the presence of various cationic ions (Cu(2+), Zn(2+), Ba(2+), and Ca(2+)). The data indicate significant decrease of humic acid surface charge by decreasing the pH value from 10.0 to 4.1. Similar decrease of humic acid surface charge was observed by increasing either the ionic strength or the affinity of the divalent cation toward the humic acid. At ambient temperature the adsorption of humic acid on the quartz sand seems to be controlled mainly by electrical interaction between the organic particle and the solid substrate. A correlation is found between the surface charge and the adsorbed amount of the polymer, the adsorbed amount increases when the surface charge of humic acid decreases. The increase of the adsorbed amount with the temperature suggests that adsorption process is endothermic.

Adsorption↗

A simultaneous electrochemical impedance and quartz crystal microbalance study on antihuman immunoglobulin G adsorption and human immunoglobulin G reaction.

The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric quartz crystal (PQC) as well as electrochemical impedance (EI) parameters were measured and discussed. The standard heterogeneous rate constants of the ferricyanide/ferrocyanide couple before and after the antibody adsorption and antibody-antigen reactions were determined. The results show that the amount for antibody adsorption was the greatest on the most hydrophobic (1-dodecanethiol-modified) surface, while the antibody bioactivity was almost identical on the three kinds of surfaces. Two parameters simultaneously obtained, Deltaf and DeltaC(s) (interfacial capacitance), have been used for the first time to estimate both the association constant of the immunoreaction and the valence of antigen with satisfactory results. The proposed method may find wide application in interfacial biochemistry studies for its advantages in providing real-time multidimensional piezoelectric and electrochemical impedance information.

Adsorption↗