Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pattern Recognition, Visual”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Pattern-reversal visual evoked potentials and retinal eccentricity.

The effect of stimulation of discrete areas of the retina on visual evoked potentials (VEP) was studied in 16 normal volunteers. The stimulus consisted of a constant luminance 2 degrees 18' field containing checks of 34'30' reversing at a frequency of 500 msec. The amplitude of the VEP was highest at the fixation point and inside the 2 degrees isopter. Rapid amplitude decrement was noted with stimuli located within the 2-4 degrees isopters. No identifiable response was obtained outside the 4 degrees or 6 degrees isopter with a 2 degrees 18' stimulus. VEP could, however, be elicited by increasing the size of the stimulus. The smallest size of a field required to evoke a detectable response also varied in relations to retinal eccentricity. Stimulation at 0 degree, 8 degrees and 14 degrees horizontal eccentricities with fields of a size estimated to activate an equivalent amount visual cortex produced VEPs of similar amplitude.

Electroencephalography↗

Transient visually evoked potentials to the pattern reversal and onset of sinusoidal gratings.

Transient visually evoked potentials (VEPs) recorded in response to the contrast reversal and onset of spatially sinusoidal gratings have been investigated. Previous reports of an increase in the latency of the response at higher spatial frequencies have been confirmed but only for spatial frequencies higher than 2 c/deg. At lower spatial frequencies it is suggested that two positive components interact resulting in a departure from a monotonic relationship between latency and spatial frequency. Below 1 c/deg pattern reversal and pattern onset modes of stimulation produced VEPs of similar amplitude and wave form. Above 1 c/deg the amplitude of the pattern onset response peaked at a higher spatial frequency than the response to pattern reversal, and the response was dominated by a negative (N1) rather than a positive component (P1). This distinction has been corroborated by investigating the effect of field size variation. The peak amplitudes shifted to a lower spatial frequency with increase in field size but at all field sizes the N1 component of the pattern onset response peaked at a higher spatial frequency than the other components measured. It is attempted to relate these findings to previous studies of both grating and checkerboard VEPs and to psychophysical studies of contrast sensitivity.

Electroencephalography↗

The recovery cycle of the pattern visual evoked potential in normal subjects and patients with multiple sclerosis.

The recovery cycle of amplitude and latency of the P100 of the chequerboard pattern reversal visual evoked response was studied in 16 normal subjects and 20 patients with multiple sclerosis. There was no clear-cut pattern of recovery with respect to amplitude but at interstimulus intervals of less than 40 msec the latency of the test response P100 tended to be significantly delayed, the magnitude of this delay being virtually constant at intervals of 20 msec or less. Only 8 of 40 eyes from the 20 multiple sclerosis patients showed a pattern of recovery of latency significantly different from the normal subjects. Possible mechanisms for these observations are discussed with particular reference to current concepts of the pathophysiology of multiple sclerosis.

Electroencephalography↗

Scalp potential fields evoked by grating stimuli: effects of spatial frequency and orientation.

Visually evoked potentials were recorded from an array of 16 electrodes over the occipital cortex in 12 subjects. Grating stimuli of different spatial frequencies were presented on a circular test field, and potential fields evoked by vertical, horizontal and oblique stimuli were compared. Component latencies were determined by computing a reference-independent measure of field power. Scalp field maps were constructed at component latencies and compared over all conditions. Significant influences of both spatial frequency and orientation on component latencies were found. Component latencies were shortest for 2.3 c/deg gratings, and for vertically oriented stimuli. Latencies increased for horizontal, and further for oblique, gratings. The effect of spatial frequency or orientation on the location of the major components on the scalp was less pronounced. On the other hand, there were significant differences both in component latency and scalp distribution when upper and lower hemiretinal stimuli were compared. Upper hemiretinal stimulation yielded shorter latencies and a more anteriorly located potential peak on the scalp.

Adult↗

Hemispheric asymmetry of visual evoked potentials in patients with well-defined occipital lesions.

Visual evoked potentials were examined in 3 patients who had well defined unilateral occipital lobectomy. In an attempt to resolve discrepancies in the interpretation of hemispheric asymmetries in evoked potentials, recordings were obtained from a wide array of electrodes with multiple montages during full-field and hemi-field stimulation with checkerboard pattern reversal and during full-field flash stimulation. The discrepancies appear to be due primarily to differences in electrode montages used in recording. The use of a midfrontal reference electrode reliably produces a paradoxical EP lateralization: abnormal EPs are recorded over the intact occipital lobe and normal EPs are recorded over the ablated occipital lobe. These findings are fully consistent with the interpretation of Barrett et al. (1976) that the generator of the P100 has an equivalent dipole located in the calcarine cortex on the posteromedial surface of the contralateral hemisphere. Our findings support the use of the Queen Square montage (Halliday et al. 1977). The use of electrodes at O1 and O2 referred to the ipsilateral earlobe yields inconsistent lateralization and should be discouraged. The lateralization of EP abnormalities did not differ for flash and pattern reversal, although the asymmetries were sometimes more prominent with pattern reversal.

Brain↗

Neurophysiological signs of brain damage due to glue sniffing.

Recordings of the brain electrical responses to pattern reversal (checkerboard) visual stimuli showed significantly increased latencies in a group of 12 young people who had been sniffing glue over a prolonged period. Only small improvements were observed in two people who had repeat recordings after 6 months' abstinence. These results show that chronic glue sniffing can lead to long lasting brain damage.

Adhesives↗

The effect of change in a stimulus sequence on P300.

In past studies, the P300 amplitude of the ERP has been found to be enhanced for infrequent, unpredictable and/or task-relevant eliciting events. A fourth factor, namely the physical change between two consecutive stimuli in event sequences used, has often been confounded with frequency, predictability and relevance. The current study examined whether change also increases the P300 amplitude. Fourteen adults viewed sequences of slides in which predictability, task (counting) and change varied within subject. ERP was recorded at Cz, Pz, Oz and Fz. P300 amplitudes were significantly larger: (1) for unpredictable than for predictable events, (2) for counted than for non-counted stimuli, and (3) for stimulus change rather than no stimulus change. The change effect interacting with counting suggested that P300 amplitude may be particularly increased by stimulus changes imbedded within only certain cognitive tasks.

Adult↗

Electrophysiological correlates of hierarchical stimulus processing: dissociation between onset and later stages of global and local target processing.

In the discussion of whether the processing of hierarchically structured stimuli proceeds from the more global to the more local level or vice versa, it is frequently assumed that the relative speed of global/local target identification (response time (RT) advantage) and the direction of interference from local/global distractors reflect the order of processing. Studies both in brain-injured patients and in normals, however, have demonstrated that RT advantage and interference are dissociable, leading to the conclusion that they do not provide a valid index of the order of global/local processing. The aim of the present event-related brain potential (ERP) study was to assess electrophysiological correlates of global/local processing and to determine how the relative speed of responding to global and local targets is related to these ERP measurements. In a divided-attention paradigm, subjects were asked to respond to hierarchically structured letter stimuli that contained a target letter either at the global or at the local level. The behavioral results confirmed a dissociation between RT advantage and interference. ERP analysis revealed an early posterior negative component (denoted as N250) as a sign of early global/local target perception. It was found that RT advantage is not a valid measure of the onset nor of the time course of this component. Furthermore, the N250 components to global and local targets exhibited a different time course and a different topographical distribution, suggesting that they are determined by separate processing structures. Together, the behavioral and electrophysiological results support the view that global and local target perception may be mediated by separate brain systems acting, at least initially, in parallel.

Adolescent↗

Pattern-evoked potentials and Bloch's law.

Experiments are described which show that the latencies, unlike the amplitudes, of the C1 and C2 components of the human pattern-onset VEP do not conform to the contrast equivalent of Bloch's law. Whereas each component's amplitude is linearly related to the log of the (contrast X duration) product below a critical duration of 50 msec, its latency is independent of the stimulus pattern's duration and determined by its contrast alone; increasing by 30-35 msec for a 1.4 log unit contrast decrease. The relationship between these results and corresponding single-unit findings in the cat is discussed.

Evoked Potentials, Visual↗

Visual evoked potentials to double-pulse pattern presentation.

The temporal resolution and summation characteristics of human cortical processes were investigated by recording an individual VEP component, C1, to the double-pulse presentation of pattern pairs of both the same (+ve/+ve; -ve/-ve) and of opposite (+ve/-ve; -ve/+ve) contrast polarity at varying onset-to-onset intervals (SOA). The results show that comparable limiting SOA values of 40-50 msec are needed for the C1 components to the two patterns to separate out to form a double-peaked response and for the stimulus to be seen as two distinct events. Also, the amplitude variations of the single-peaked response obtained at shorter SOAs show evidence of complete precortical response integration for SOA values below 5-10 msec and partial integration for values up to 30-40 msec, which again correspond to the results of related psychophysical studies. These VEPs show no reflection, however, of the inhibition/summation effects reported for subjective responses to pattern pairs of the same/opposite contrast polarity at SOA values between 40 and 70 msec. The implications of these findings are discussed.

Evoked Potentials, Visual↗

Comparison of the spatial response properties of the human retina and cortex as measured by simultaneously recorded pattern ERGs and VEPs.

Electroretinograms and visual evoked potentials were simultaneously recorded from adult subjects using a checkerboard pattern stimulus reversing at 0.94, 3.75 and 7.5 Hz. Two contrast levels were used: 30 and 85%. The data obtained from the cortex (VEPs) show spatial tuning properties for all temporal frequencies at both contrast levels, with the peak of the amplitude-check size function occurring between 15 and 30 min. Tuning properties were found at the retina but only at the high contrast level and for the faster (3.75 and 7.5 Hz) temporal frequencies. The results demonstrate that spatial tuning is present in the human retina but not under as wide a range of conditions as found at the cortex.

Adult↗

Spatial frequency tuning in the visual evoked potential elicited by sine-wave gratings.

This investigation examined the onset response of the transient visually evoked potential elicited by the appearance-disappearance of sine-wave gratings at various levels of spatial frequency, suprathreshold contrast, and stimulus duration. The response was most easily characterized by two negative-positive complexes that were differentially tuned to spatial frequency. The earlier complex peaked at high spatial frequencies while the later complex peaked at low spatial frequencies. For both complexes, amplitude showed only slight variations across three-octave ranges of contrast and duration. Latency was curvilinearly related to spatial frequency, decreased with increasing contrast, and showed no apparent change as a function of duration.

Adult↗

Responses of neurons in visual cortex (V1 and V2) of the alert macaque to dynamic random-dot stereograms.

A substantial proportion of both simple and complex neurons in the cortex subserving central vision are differentially sensitive to binocular disparity of isolated line patterns (local stereopsis), a sensitivity based on a positional disparity between the neuron's receptive fields in the two eyes. In addition, a subset of cortical neurons, nearly all complex neurons, responds to dynamic random-dot stereograms containing no depth cues other than disparity. These neurons are capable of signaling the correct binocular matches among a multitude of false matches in the stereograms (global stereopsis). The discovery of cyclopean neurons in striate cortex, at early stages of the processing neural network for stereoscopic vision provides a new insight of the basic neural mechanisms underlying binocular depth perception.

Animals↗

The topography of scalp potentials evoked by pattern pulse stimuli.

Pattern pulse stimuli evoke activity in two distinct regions of the human visual cortex in temporal sequence. The earlier responding region (implicit time 93 msec) is localized to a relatively small region near Oz. Its topography is very sensitive to the position of the evoking stimulus in the visual field; it is dominated by a representation of the visual field near the vertical meridian. The later responding cortical region (implicit time 131 msec) is larger than the earlier one. Its medial border touches the lateral border of the earlier responding cortical region and it extends several cm laterally. Its topography is much less sensitive to the position of the evoking stimulus in the visual field. Stimuli presented to the ipsilateral field evoke either weak or no measurable activity in the earlier responding cortical region but often evoke measurable activity near the lateral boundary of the later responding cortical region. These results suggest that the earlier responding cortical region is striate cortex and that the later responding cortical region is composed of visual areas V2, V3, V3A, and V4.

Brain Mapping↗

Visual persistence of stereoscopic stimuli: electric brain activity without perceptual correlate.

Dynamic random-dot stereograms (RDS) were used to study cortical neuronal mechanisms related to visual persistence in nine subjects. Electric brain potential components evoked by stereoscopic stimuli were compared to those evoked by conventional checkerboard stimuli with contrast borders. In a pattern-onset/offset presentation visual persistence thresholds were significantly lower for stereoscopic than for contrast stimuli: with temporally modulated patterns stereoscopic stimuli appeared to visually persist at much shorter interstimulus intervals than contrast stimuli. With stereoscopic stimuli all subjects reported not seeing changes of the RDS pattern, while the corresponding evoked potentials showed components related to the stimulus changes indicating a consistent discrepancy between psychophysical and electrophysiological data. The electrical brain activity was not caused by vergence eye movements elicited by the stereoscopic stimulus. In addition, for dynamic RDS stimuli a significant inverse linear relationship between temporal modulation frequency and evoked potential amplitude was found which was not observed with comparable contrast stimuli.

Adult↗