Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PROSTHESIS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression.

OBJECTIVE: The effect of prosthesis-patient mismatch on clinical outcome and left ventricular mass regression after aortic valve replacement remains controversial. Data on whether the clinical effect of prosthesis-patient mismatch depends on left ventricular function at the time of aortic valve replacement are lacking. This study examined the long-term clinical and echocardiographic effects of prosthesis-patient mismatch in patients with and without left ventricular systolic dysfunction at the time of aortic valve replacement. METHODS: Preoperative and serial postoperative echocardiograms were performed in 805 adults who underwent aortic valve replacement between 1990 and 2003 and who were subsequently followed up in a dedicated valve clinic (follow-up, mean +/- SD, 5.5 +/- 3.5 years; maximum, 14.2 years). Preoperative left ventricular function was defined as normal (ejection fraction > or =50%) in 548 patients and impaired (ejection fraction <50%) in 257 patients. RESULTS: Patients with impaired preoperative left ventricular function and prosthesis-patient mismatch (indexed effective orifice area < or =0.85 cm2/m2) had a decreased overall late survival (hazard ratio, 2.8; P = .03), decreased freedom from heart failure symptoms or heart failure death (odds ratio of 5.1 at 3 years after aortic valve replacement; P = .009), and diminished left ventricular mass regression compared with patients with impaired preoperative left ventricular function and no prosthesis-patient mismatch. These effects of prosthesis-patient mismatch were not observed in patients with normal preoperative left ventricular function. CONCLUSIONS: Prosthesis-patient mismatch at an indexed effective orifice area of 0.85 cm2/m2 or less after aortic valve replacement primarily affects patients with impaired preoperative left ventricular function and results in decreased survival, lower freedom from heart failure, and incomplete left ventricular mass regression. Patients with impaired left ventricular function represent a critical population in whom prosthesis-patient mismatch should be avoided at the time of aortic valve replacement.

Aged↗

Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant.

BACKGROUND: Although small valve size and patient-prosthesis mismatch are both considered to decrease long-term survival, little direct evidence exists to support this hypothesis. METHODS: To assess the prevalence of patient-prosthesis mismatch and the influence of small valve size on survival, we prospectively studied 1,129 consecutive patients undergoing aortic valve replacement between 1990 and 2000. Mean and peak gradients and indexed effective orifice area were measured by transthoracic echocardiography postoperatively (3 months to 10 years). Abnormal postoperative gradients were defined as those patients with mean or peak gradient above the 90th percentile (mean gradient > or = 21 or peak gradient > or = 38 mm Hg). Patient-prosthesis mismatch was defined as those patients with indexed effective orifice area below the 10th percentile (< 0.60 cm2/m2). RESULTS: A multivariable analysis identified internal diameter of the implanted valve as the only independent predictor of abnormal gradients postoperatively. However, there was no significant difference in actuarial survival between normal and abnormal gradient groups (7 years: 91.2% +/- 1.5% versus 95.0% +/- 2.2%; p = 0.48). Freedom from New York Heart Association class III or IV (7 years: 74.5% +/- 3.1% versus 74.6% +/- 6.2%; p = 0.66) and left ventricular mass index were not different between normal and abnormal gradient groups. Patients with and without patient-prosthesis mismatch were similar with respect to postoperative left ventricular mass index, 7-year survival (95.1% +/- 1.3% versus 94.7% +/- 3.0%; p = 0.54), and 7-year freedom from New York Heart Association class III or IV (79.3% +/- 6.6% versus 74.5% +/- 2.5%; p = 0.40). In patients with patient-prosthesis mismatch and abnormal gradients, the majority had prosthesis dysfunction owing to degeneration. CONCLUSIONS: Severe patient-prosthesis mismatch is rare after aortic valve replacement. Patient-prosthesis mismatch, abnormal gradient, and the size of valve implanted do not influence left ventricular mass index or intermediate-term survival.

Adult↗

Efficacy and patient satisfaction associated with penile prosthesis revision surgery.

INTRODUCTION: Complications that arise after placement of a penile prosthesis may result in the need for revision surgery. Few contemporary penile prosthesis series have focused solely on describing the efficacy and patient satisfaction associated with penile prosthesis revision surgery. AIM: To determine the overall success of penile prosthesis revision surgery in providing the patient with a functional implant. Device efficacy and patient satisfaction with penile prosthesis revision surgery will be assessed using psychometrically validated instruments. MAIN OUTCOME MEASURES: The erectile function (EF) and satisfaction domains of the International Index of Erectile Function (IIEF) were used to quantify the overall efficacy and patient satisfaction with revision surgery. METHODS: Data were derived from a prospective database of consecutive patients undergoing penile prosthesis revision surgery performed by a single surgeon (B.R.K.). Eleven patients filled out the IIEF prior to surgery and 26 completed it following surgery. RESULTS: Thirty-nine consecutive patients underwent 55 revision procedures related to a prior penile prosthesis. Thirty-four patients (87%) have a functional implant with a median follow-up of 6.5 months (range 1-42 months). Significant improvements in the overall IIEF, EF domain, and satisfaction domain were seen in those patients studied prior to and following revision surgery. The total IIEF, EF domain, and satisfaction domain of the IIEF for the group of 26 responders were 60.7 +/- 19.3, 26.6 +/- 8.7, and 15.7 +/- 5.6, respectively. Patients with fibrotic corporal bodies scored significantly lower on the EF and satisfaction domains than did any other group. CONCLUSIONS: Penile prosthesis revision surgery is highly successful in providing men with a functional implant. The prostheses function well and patients are satisfied with their devices. Further study of those men with corporal fibrosis is warranted in order to determine the factors needed to improve their overall satisfaction with revision surgery.

Adult↗

[Proximal femoral reconstruction with megaprosthesis versus allograft prosthesis composite. A comparative study of functional results, complications and longevity in 41 cases].

PURPOSE OF THE STUDY: To compare femoral reconstruction using megaprosthesis versus allograft prosthesis composite. MATERIAL AND METHODS: Forty-one consecutive proximal femoral reconstructions with an allograft-prosthesis composite (21 cases) or a megaprosthesis (20 cases) after tumor resection were reviewed in a retrospective study. The following criteria were considered: functional outcome; long term survival; complications. Chi-square test and Wilcox tests were used to compare groups. The medium and long-term survival curves for these reconstructions were made using the Kaplan-Meier standard methods. The failure of prosthesis was defined as revision for mechanical failure (either aseptic loosening or dislocation), for infection or local recurrence. The comparison of the curves was performed using the Log-Rank test. RESULTS: Infection (10 p. 100) and instability, in both groups, and loosening, in the megaprosthesis group, were the common causes of failure. There was difference between functional results in the two groups (limping and crutches using was more lower in allograft-prosthesis composite group). Survival analysis showed a 5 and 10-year survival of 77 +/- 12 p. 100 for the patients with composites. Five and ten - year survival were 73 +/- 11 p. 100 and 0 p 100 respectevely for those with megaprostheses. No significant difference was noted between survival of these two groups but a tendancy (p =0.09). Radiological allograft resorption was noted for more than 50 p. 100 of allograft composite prosthesis without modification of functional result or symptomatic loosening. DISCUSSION: The functional results seem better in the composite group when compared to the megaprosthesis group. Reconstruction of the abductor mechanism is essential to stabilize the prosthesis and to decrease the limp. When the great trochanter cannot be preserved, we used suture of gluteus medius tendon to tensor of fascia lata, which is re-enforced using a piece of biceps femoris. The dislocation rate was approximately the same in our two groups. Several authors reported a lower dislocation rate with composite reconstructions than massive prosthesis. The rate of infection is similar to other reported series. In our study it has been possible to show a tendancy for superior survival of the composite reconstruction. When the review was later than 5 years the radiological appearance of the graft in our series was often concerning with resorption or fragmentation present in six of the eight cases. This radiological appearance is not as yet responsible for any revision or any change in the functional result however it does remain a worry. CONCLUSION: Composite reconstructions probably allow a better functional result when considering proximal reconstruction of the femur. The radiological appearance of these allografts in the long term is however worry some without any evidence so far of worsening functional level or any evidence of prosthetic loosening. It would seem to us that the current level of knowledge would advocate the use of massive allografts together with prosthesis. This does seem still to remain the best choice for proximal femoral reconstruction.

Adult↗

Reoperation for complications of the Angelchik antireflux prosthesis.

The Angelchik antireflux prosthesis is associated with complications that require reoperation in 5% to 15% of patients. To determine the morbidity and success of reoperation for these complications, we conducted a retrospective study of 15 patients. Time to reoperation ranged from 3 weeks to 113 months with a mean of 31 months. Indications for reoperation included dysphagia (8 patients), recurrent reflux (6 patients), and prosthesis migration (1 patient). Ten patients underwent prosthesis removal and fundoplication, 4 had prosthesis removal without fundoplication, and 1 patient had the prosthesis repositioned. Iatrogenic splenic injury occurred in 2 patients (13%); one splenectomy and one splenic repair were done. Four patients (27%) required intraoperative blood transfusion. There were no operative deaths. Removal of the prosthesis without fundoplication resulted in a significantly higher incidence of recurrent reflux (75%) than prosthesis removal and fundoplication (10%) (p < 0.04). Although reoperation for complications of the Angelchik antireflux prosthesis can be technically difficult, morbidity and mortality are acceptable. An antireflux procedure should be done at the time of prosthesis removal.

Adult↗

Effect of a maxillary glossectomy prosthesis on articulation and swallowing.

Swallowing was found to be substantially improved with the prosthesis. Less aspiration, less time necessary to complete the swallow, and greater variation in food consistency tolerated were all positive results of the prosthesis. In addition, videofluoroscopic studies of tongue movements during speech revealed that tip-alveolar /t-d/ and back-velar /k-g/ productions were more normal with the prosthesis. With the prosthesis, the understandibility of /t/ and /d/ was improved 20% and that of /k/ and /g/, 33%. It is clear that compromises must be effected in prosthesis design to facilitate improvement in both speech and swallowing. A large prosthetic mass in the oral cavity can also negatively change speech resonance. These issues are being investigated, as are acoustic and perceptual studies of speech articulation. Future research should address whether a combination of maxillary and mandibular prostheses would result in better speech and swallowing function. A mandibular prosthesis could replace missing teeth and alveolar contour that might influence speech and swallowing. A mandibular prosthesis might also allow construction of a smaller maxillary glossectomy prosthesis to interact with the mandibular prosthesis.

Articulation Disorders↗

Effect of a speech prosthesis on electromyographic activity levels of the levator veli palatini muscle activity during syllable repetition.

OBJECTIVES: To examine whether repeated production of a syllable effects levator veli palatini muscle activity for speakers with velopharyngeal incompetence and whether the effect can be changed by a speech prosthesis. DESIGN: Repeated-measures analysis; each subject produced the speech sample /pu/ more than 200 times in each of 2 experimental conditions. SETTING: Graduate dental school in Japan. PARTICIPANTS: Four patients with operated cleft palate with a speech prosthesis. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Electromyographic traces were highband-pass filtered at 30 Hz, rectified, and smoothed with a time constant of 30 ms. Electromyographic traces were made of each production in 2 conditions: (1) without the prosthesis and (2) with the prosthesis. The regression slope of the linear regressor line, when smoothed levator activity was the criterion variable and the number of productions was the explanatory variable, was calculated in each condition. RESULTS: The mean value of levator activity was significantly smaller with the prosthesis in than without it (P<.10, t test). With the prosthesis, the regression slope was significant for all 4 subjects, whereas it was insignificant without the prosthesis for 3 of 4 subjects (P<.10, t test). Absolute values of the regression slope were significantly smaller with the prosthesis than without it for all subjects (P<.10, t test). Comparison of the regression slopes for the 2 conditions identified a significant difference in slopes between the 2 conditions (P<.10, t test). CONCLUSION: In operated cleft palate patients with velopharyngeal incompetence, a speech prosthesis can stabilize both temporal changes in levator muscle activity and connected speech, such as conversation.

Adolescent↗

First clinical experience with a new non-indwelling voice prosthesis (Provox NID) for voice rehabilitation after total laryngectomy.

CONCLUSION: The new Provox NID non-indwelling voice prosthesis investigated in this study provides a good option for laryngectomized patients using non-indwelling voice prostheses and can potentially improve safety and increase patients' satisfaction with their voice and speech. OBJECTIVE: To investigate the feasibility of and patient satisfaction with the Provox NID non-indwelling voice prosthesis. MATERIAL AND METHODS: Pre- and post-study questionnaires were used to evaluate the patients' former voice prosthesis and the Provox NID voice prosthesis. In addition, measurements of pull-out force, maximum phonation time and loudness were made for both voice prostheses. In vitro measurements of airflow characteristics were also made. Following a 6-week trial, all patients provided feedback on the new voice prosthesis and the results were used to further improve the Provox NID. This final version of the new voice prosthesis was subsequently trialled and evaluated by 10 patients 6 months later. RESULTS: Overall results showed that patient satisfaction with the Provox NID non-indwelling voice prosthesis was favourable. The pull-out force for the new prosthesis was significantly higher than that for the formerly used prosthesis and its aerodynamic characteristics were better.

Aged↗

Body image and prosthesis satisfaction in the lower limb amputee.

PURPOSE: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. METHOD: A total of 44 valid responses were obtained to an internet survey regarding prosthesis satisfaction, body image and phantom pain. Spearman Rho correlations were calculated for these three domains. RESULTS: Moderate to high negative correlations were observed between body image disturbance and prosthesis satisfaction. These were consistent across genders. Other relationships were also revealed, including positive correlations between prosthesis satisfaction with hours of use and negative correlations between prosthesis satisfaction and pain experience, although strong differences between genders were observed for these. The length of time for which respondents had had their prosthesis bore little relation to other variables. CONCLUSION: The present research is instructive of the close relationship between body image and prosthesis satisfaction, as well as gender variations in these relationships, in lower-limb prosthesis users. These findings have implications for targeted service provision in prosthetic rehabilitation.

Adolescent↗

Electromyographic study of muscular activity in the amputation stump while walking with PTB- and PTB-suction prosthesis.

A comparative electromyographic study of the muscular activity while waling with PTB and PTB-suction prosthesis is presented. The PTB-suction prosthesis has been used clinically since 1969 with generally promising results. This prosthesis is mainly of value for patients with skin problems (poor sensibility and contact sores) and also has a cosmetic advantage. The present investigation has demonstrated that there is frequently a muscular activity pattern when walking with the PTB-suction prosthesis which is similar to that of a normal leg. The PTB prosthesis often shows a pattern of simultaneous contractions of antagonistic muscles. Furthermore, when the EMG-pattern is more "normal" and the amplitude higher with the PTB-suction prosthesis, it is probably the more suitable prosthesis. These EMG investigations can thus be a possible adjunct in the selection between the PTB-suction prosthesis and PTB prosthesis.

Adaptation, Physiological↗

Complete denture with a removable palatal lift prosthesis: a case report and clinical evaluation.

The palatal lift prosthesis is used to alleviate rhinopharyngeal closure dysfunction. It is generally problematical to use in edentulous patients, because the palatal lift prosthesis requires secure retention of the denture base and is difficult for the patient to retain while eating. This article describes the fabrication of a complete denture with a removable palatal lift prosthesis and a clinical evaluation of the denture's stability. A sprue pin and tube were used as a connecting attachment between the removable palatal lift prosthesis and the denture base. The force required for lifting the soft palate and the denture's stability were measured in the clinical evaluation. The prosthesis required an average retentive force of 0.26 N for each 1 mm of soft palate lift. The force required to dislodge the denture was measured with and without the palatal lift prosthesis in place. The force required to dislodge the conventional complete dentures of five healthy individuals was also measured as a reference. The denture was 24.4% less stable when the palatal lift prosthesis was in place and was generally easier to dislodge than were conventional dentures. This denture with a removable palatal lift prosthesis is useful for patients with dysfunction of the soft palate involving hypernasal speech who have difficulty in retaining the prosthesis while eating.

Adult↗

[Vascular access for haemodyalisis. Comparative analysis of the mechanical behaviour of native vessels and prosthesis].

INTRODUCTION: The prosthesis nowadays used in the vascular access for haemodialysis have low patency rates, mainly due to the luminal obstruction, determined by the intimal hyperplasia. Several factors have been related to de development of intimal hyperplasia and graft failure. Among them are the differences in the biomechanical properties between the prosthesis and the native vessels. In the searching for vascular prosthesis that overcomes the limitations of the currently used, the cryopreserved vessels (cryografts) appear as an alternative of growing interest. However, it is unknown if the mechanical differences or mismatch between prosthesis and native vessels are lesser when using cryografts. OBJECTIVE: To characterize and compare the biomechanical behaviour of native vessels used in vascular access and cryografts. Additionally, segments of expanded polytetrafluoroethylene (ePTFE) were also evaluated, so as to evaluate the potential biomechanical advantages of the cryografts respect to synthetic prosthesis used in vascular access. METHODS: Segments from human humeral (n = 12), carotid (n = 12) and femoral (n = 12) arteries, and saphenous vein (n = 12), were obtained from 6 multiorgan donors. The humeral arteries were studied in fresh state. The other segments were divided into two groups, and 6 segments from each vessel were studied in fresh state, while the remaining 6 segments were evaluated after 30 days of criopreservation. For the mechanical evaluation the vascular segments and 6 segments of ePTFE were mounted in a circulation mock and submitted to haemodynamic conditions similar to those of the in vivo. Instantaneous pressure (Konigsberg) and diameter (Sonomicrometry) were measured and used to calculate the viscous and elastic indexes, the compliance, distensibility and characteristic impedance. For each mechanical parameter studied, the mismatch between the prosthesis and the native vessel was evaluated. RESULTS: The ePTFE was the prosthesis with the higher mechanical mismatch (p < 0.05). The venous and arterial cryografts showed the least mismatch with native veins and arteries, respectively. The prosthesis with the least mechanical mismatch was different, depending on the native vessel evaluated, and for a native vessel, on the parameter considered. CONCLUSION: The mechanical mismatch between the native vessel and the vascular prosthesis used in a vascular access could be reduced using cryografts.

Adult↗

Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement.

BACKGROUND: Valve prosthesis-patient mismatch is a frequent problem in patients undergoing aortic valve replacement and its main hemodynamic consequence is to generate high transvalvular gradients through normally functioning prosthetic valves. The persistence of high gradients may hinder or delay the regression of left ventricular hypertrophy after aortic valve replacement. METHODS: The aim of the study was to determine the impact of prosthesis-patient mismatch on the postoperative regression of left ventricular mass. Left ventricular mass was measured by Doppler echocardiography in 109 patients undergoing aortic valve replacement with a single type of bioprosthesis (Carpentier-Edwards Perimount) for pure aortic stenosis. Prosthesis-patient mismatch was defined as a projected indexed effective orifice area less than 0.90 cm2/m2. On this basis, 58/109 (53.2%) patients had prosthesis-patient mismatch. RESULTS: There was a good correlation (r = 0.61, p < 0.001) between the postoperative mean transprosthetic gradient and the projected indexed effective orifice area. The absolute and relative left ventricular mass regression was significantly (p = 0.002 and p = 0.01, respectively) lower in patients with prosthesis-patient mismatch (-48 +/- 47 g, -17% +/- 16%) compared to those with no prosthesis-patient mismatch (-77 +/- 49 g, -24% +/- 14%). In multivariate analysis, a larger projected indexed effective orifice area, female gender and a higher preoperative left ventricular mass are independent predictors of greater left ventricular mass regression. CONCLUSIONS: This study shows that in patients with pure aortic stenosis prosthesis-patient mismatch is associated with lesser regression of left ventricular hypertrophy after aortic valve replacement. These findings may have important clinical implications given that prosthesis-patient mismatch is frequent in these patients.

Aged↗

Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure.

PURPOSE: The inflatable penile prosthesis is well established as an effective treatment for select patients with organic erectile dysfunction. The risk of prosthetic infection at primary implantation is approximately 2%. However, for revision or replacement procedures the risk of infection has been reported to be as high as 13.3%. To minimize the overall risk of prosthetic infection an antibiotic coated inflatable penile prosthesis (InhibiZone) has been developed. To assess the impact on infection rates we reviewed our experience with the use of this device at prosthesis replacement for mechanical failure. MATERIALS AND METHODS: We retrospectively reviewed the records of all patients undergoing inflatable penile prosthesis replacement for mechanical failure with an antibiotic coated prosthesis between May 2001 and November 2004. Salvage procedures for clinically infected prostheses were excluded from analysis. Chart review was performed with examination of operative notes, all postoperative contacts and microbiological data. RESULTS: A total of 55 patients underwent replacement of an inflatable penile prosthesis for mechanical failure using a device coated with rifampin and minocycline HCL (InhibiZone). In all patients before reimplantation component spaces were irrigated in standard fashion. With a median followup of 32 months (range 12 to 54) postoperative device infection requiring explantation developed in 1 patient (1.8%). Intraoperative cultures from the pump site grew coagulase negative staphylococcus. CONCLUSIONS: Our data suggest that an antibiotic coated inflatable penile prosthesis may lead to decreased infection rates in patients undergoing penile prosthesis replacement for mechanical failure.

Adult↗

Outcomes and satisfaction rates for the redesigned 2-piece penile prosthesis.

PURPOSE: We evaluated long-term viability, quality of life and satisfaction with the redesigned 2 piece Ambicor inflatable penile prosthesis. This device underwent revision of the rear tip extender and reinforcement of the pump tubing connection to decrease fluid leak failure in 1998. MATERIALS AND METHODS: In this retrospective analysis we evaluated 146 men with erectile dysfunction at 2 centers who underwent device implantation between June 1999 and October 2004 with the redesigned prosthesis. Patient information forms were completed, including patient history, surgical information and revision data. Patients were mailed a modified Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire, a modified Erectile Dysfunction Inventory of Treatment Satisfaction Partner survey and a questionnaire regarding pertinent inflatable penile prosthesis questions. RESULTS: A total of 146 men with a mean age of 58.7 years (range 25 to 78) were evaluated after inflatable penile prosthesis placement. Time from implant to followup was 3 to 73 months (mean 38). Only 1 device (0.7%) was removed due to infection. One implant (0.7%) was replaced due to fluid loss and 1 (0.7%) was revised due to improper sizing. Kaplan-Meier life table analysis indicated that the percent of patients free from reoperation was 99.2% at 12 months, 99.2% at 36 months and 91% at 48 months or greater. Of the 101 subjects completing the survey the average patient used the prosthesis 5 times monthly and 88.9% reported continued use. Of the patients 91% said that it was easy to use and 95% had little to no trouble learning to use it, while 84% stated that the inflatable penile prosthesis provided good to excellent rigidity for coitus. Overall patient and partner satisfaction was 85% and 76%, respectively. Of the patients 86% said that they would recommend the prosthesis to friends or if need be undergo the procedure again. CONCLUSIONS: The redesigned Ambicor 2-piece penile prosthesis appears to be safe and effective. It is associated with a low rate of revision as well as high patient and partner satisfaction.

Adult↗

Fitting a hand-glove prosthesis to enhance the reconstructed mutilated hand.

Microsurgical reconstruction of the severely mutilated hand aimed at improving prehensile functions often does not address the esthetic aspects of the hand. The poor appearance of the reconstructed hand affects its active display and use. A hand-glove prosthesis may be prescribed in this instance to enhance the overall form and function of the mutilated hand. We reviewed 16 cases of mutilating hand injuries in which surgical reconstructions were performed and the patients were subsequently fitted with a hand-glove prosthesis to augment the outcome. An improved appearance was achieved in all patients fitted with the prosthesis. The patients' sense of confidence was also enhanced, which in turn promoted the active and open use of the reconstructed hands. While prescribed primarily to improve the appearance of the reconstructed hands, these prostheses were documented to enhance the physical hand functions in 11 cases by increasing the span of the hand and providing an opposable post and a palmar base for holding and for anchorage. The prosthesis enhanced assistive functions of the reconstructed hands and freed the contralateral normal hand for use in bimanual activities, such as holding a wallet and taking out money, supporting a note pad for writing, and holding a plate at buffet receptions. At the 18-month follow-up visit, 13 (87%) of the patients continued to use their prosthesis. Wear and tear were problems associated with the frequent use of the prosthesis. The expected life span of the prosthesis with daily use ranged from 2 to 3 years. All the patients acknowledged that the prosthesis played a role in their rehabilitation and that it helped them to overcome the initial psychological trauma and to come to terms with their physical loss.

Activities of Daily Living↗

[Distal radio-ulnar prosthesis].

Many procedures have been proposed for the treatment of traumatic painful instabilities of the Distal Radio-Ulnar Joint (DRUJ). Moore-Darrach, Milch, Baldwin, Bowers, Kapandji-Sauvé. Except for the Milch procedure, the risk of painful instability of the ulnar stump is real, but not very frequent if the technique is correctly applied. When this complication occurs, the best way to ensure the ulnar stump stabilization is mechanical, by mean of a DRUJ Prosthesis which we were the first to imagine and build. Used in two cases, with or without remnant ulnar head, these two types of prosthesis seem to have been favourable. Obviously, it is too early to know the final value of this prosthesis, based only on two cases, but it seemed important to make it known as an additional possibility in the treatment of the DRUJ problems. These two types of prosthesis are conceived on original principles: cementless fixation but with screws and nuts giving immediate and definitive stability and allowing a fast rehabilitation. The articular pieces are composite, metal on H.D. Polythylene. The articular surface is spherical permitting all the mobilities of this complex joint. The two articular surfaces are supported by two pieces: the proximal part, holding a hollow hemisphere, inserted in the ulna and the same for the two types of prosthesis, and a distal part, holding the sphere; this part is different according to the type of the prosthesis. We are well aware that in time and with clinical experience, some of its secondary characteristics will evolve, mainly its fixation system. At the present time this prosthesis is indicated in two "second look" situations: painful ulnar stump instability after a Kapandji-Sauvé procedure, and after a Moore-Darrach procedure. Perhaps it will be used in unstable stumps after a Bowers procedure? It is possible that this prosthesis will be used primarlly in the future when its reliability has been definitively established. We are working towards this objective.

Adult↗

Distal penile prosthesis extrusion: treatment with distal corporoplasty or Gortex windsock reinforcement.

Subcutaneous extrusion of penile prosthesis cylinders beneath the glans penis is an unusual but difficult complication of penile prosthesis. Without surgical repair, extrusion, infection, and corporeal fibrosis may ensue. Twenty-eight patients with distal corporeal extrusion were reviewed to identify the optimum treatment outcome for these penile prosthesis complications. Records of 28 men with subcutaneous distal penile prosthesis cylinder extrusion were reviewed. Mean age was 56.2 y. Etiology of erectile dysfunction was diabetes mellitus in 11, vasculogenic in 10, Peyronie's disease in five, radical pelvic surgery in five. Duration of penile prosthesis was 8-72 months (mean 42.6). No patient had penile prosthesis infection or device exposure through the skin. Distal corporoplasty was treated on 18/28 men using cylinder repositioning and direct tunica albuginea repair. Ten men underwent repair using a Gortex windsock. 8/18 corporoplasty and 6/10 windsock patients required glans fixation for treatment of hypermobile glans following cylinder relocation. In two patients with windsock repair, extrusion recurrence occurred 6 and 18 months following surgery and 1/6 had post operative infection requiring prosthesis removal. Mean surgical time for corporoplasty was 52.8 minutes while windsock reconstruction was 89.6 minutes. Distal subcutaneous penile prosthesis cylinder extrusion produces coital pain and predisposes to cylinder exposure and infection. Early repair with or without additional prosthetic materials will return penile prostheses to a normal functioning state. Distal corporoplasty with cylinder repositioning appears to be a simple, low morbidity solution to this difficult dilemma. Outcomes with distal corporoplasty result in better function, less pain, and fewer recurrences than Gortex windsock repair.

Adult↗