Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ophthalmoscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Correlations between densitometry of red-free photographs and reflectometry with the scanning laser ophthalmoscope in normal subjects and glaucoma patients.

OBJECTIVE: To compare image measurements of the retina produced by scanning laser ophthalmoscopy with those from red-free photographs (RFP) of the nerve fibre layer. SUBJECTS: The left eyes of 23 subjects (10 normal, 7 glaucoma suspect and 6 glaucomatous) were included in this study. METHOD: All the eyes were photographed using standard red-free photography, and images of the retina were digitised directly from the SLO. RESULTS: The correlation coefficient for all except three subjects was > 0.45, and the probability (p) that R = 0 was < 0.05 in all but 5 eyes. CONCLUSIONS: The data indicate that variations in retinal surface reflectivity as measured by the SLO are similar to those recorded on negative film during RFP. This further suggests that the SLO can be useful for making objective measurements of the RNFL, without the intermediate and variable steps of photography.

Densitometry↗

On the invention of the ophthalmoscope.

The author offers an English translation of three passages of Purkinje's Commentatio de examine physiologico organi visus (1823). He shows that Purkinje made three inventions: (1) by using a transparent mirror, (2) by anticipating Maxwellian illumination, and (3) by providing the first recorded ophthalmic examination of animal and human eyes.

Animals↗

[Fundus-controlled functional evaluation in macular diseases with the scanning laser ophthalmoscope].

Exact functional testing in macular diseases still presents a challenge for the ophthalmologist in detecting both small (para)central scotomas and changes in fixation habits. The recent development of scanning laser ophthalmoscopy has enabled functional testing with simultaneous observation of the fundus. In addition to automatic static threshold fundus perimetry, kinetic fundus-controlled perimetry and special fixation tasks can be applied. This method also allows the examination of reading performance combined with the exact observation of fixation and has been increasingly integrated into clinical routine. This allows more exact observations concerning macular function for diagnostic purposes, in evaluating new treatment methods, and as expertises in simulation or aggravation in patients with macular diseases.

Fixation, Ocular↗

Scanning laser ophthalmoscope fundus cyclometry in near-natural viewing conditions.

BACKGROUND: For a better understanding of motor and sensory adaptations in cyclodeviations, subjective and objective ocular torsion have to be measured under the same conditions. The search coil technique and videooculography allow natural viewing but only assess relative cycloduction, the dynamics of torsion over a short period of time. Cycloposition, on the other hand, can be measured by analysing the position of the foveola relative to the optic disc with fundus photographs but only in nonphysiological viewing. The aim of the study was to develop a technique that allows natural viewing conditions during fundus cyclometry. METHODS: The scanning laser beam of the SLO was deflected by 90 degrees with a semitransparent mirror in front of the patient's eyes. The patient was able to look through the semitransparent mirror with both eyes into the room, e.g. at Harms' tangent screen. The infrared SLO images the central retina via the mirror through the undilated pupil. Digital image analysis quantifies the cycloposition of the eye. Controlled head movements while fixating the centre of Harms' tangent screen allow measurements in reproducible gaze positions. RESULTS: The semitransparent mirror reduces SLO image brightness, but image quality is sufficient for cyclometry after contrast enhancement. The laser light can be vaguely perceived by the patient but does not interfere with natural viewing. Reproducibility of the measurement is within +/- 1 degree SD. CONCLUSION: Our modification of SLO fundus cyclometry allows direct measurements of cycloposition in natural viewing conditions. This opens a new field for investigations of cyclodeviations and their sensory and motor adaptations.

Accommodation, Ocular↗