Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Labor Stage, First”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Comparison of fentanyl with clonidine as adjuvants for epidural analgesia with 0.125% bupivacaine in the first stage of labor: a preliminary report.

48 primiparae received epidural analgesia in labor with 10 ml of 0.125% bupivacaine with epinephrine 1:800 000, and then were divided in 4 equal groups (n = 12) to receive one of the following: 5 ml saline (B); 100 mug of fentanyl (BF); 150 microg of clonidine (BC); 75 microg of clonidine and 50 microg of fentanyl (BCF). All the patients had satisfactory analgesia. Onset was similar in the 4 groups but the duration of analgesia was significantly prolonged by the addition of either 100 microg of fentanyl or 150 microg of clonidine (respectively 89.8 min and 92.5 min vs 62.5 min) (P < 0.0001). The addition of both clonidine (75 microg) and fentanyl (50 microg) produced a considerably prolonged analgesia (177.5 min) (P < 0.0001). No episodes of bradycardia were observed. Hypotension, reversed by i.v. ephedrine, occurred in 2 patients of BCF group and in 1 patient of BF and BC groups. Only patients receiving fentanyl had pruritus. Both fentanyl and clonidine produced sedation, but both incidence and severity were greater with the mixture. No differences in neonatal outcome assessed by Apgar scores and NACS, were observed.

Journal Article↗

Is manual palpation of uterine contractions accurate?

OBJECTIVE: The aims of this study were to assess the accuracy of uterine contraction palpation, determine whether the accuracy of palpation improves with experience, determine clinical factors that affect the accuracy of palpation, and evaluate the range of intrauterine pressure present when an observer notes the contraction to be mild, moderate, or strong. STUDY DESIGN: A total of 236 observations were obtained by use of intrauterine pressure catheters on 46 laboring patients in the first stage of labor. The blinded observers (obstetrics and gynecology residents, maternal-fetal medicine fellows and faculty, and labor and delivery nurses) were asked to label a contraction as mild, moderate, or strong. Patient's height, weight, parity, and gestational age, use of oxytocin, use of epidural anesthesia, and laboring position, and the level of training of the observer were noted. RESULTS: Mild, moderate, and strong contractions had intrauterine pressures of 35.2 +/- 33.8 mm Hg (+/- 2 SD), 44.9 +/- 35.4 mm Hg, and 55.5 +/- 28.0 mm Hg, respectively. The observers were accurate in predicting contraction strength 49% of the time. There was no improvement in accuracy with increased physician experience. All physicians as a group were more accurate than nurses (p < 0.05). Accuracy was not affected by clinical variables. CONCLUSION: Manual palpation of uterine contractions is an inaccurate means of determining contraction strength.

Female↗