Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELECTROMYOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Single-fiber electromyography shows terminal axon dysfunction in Miller Fisher syndrome: a case report.

We studied a patient with ophthalmoparesis and pupillary areflexia 2 weeks after a viral syndrome. Miller Fisher syndrome was suspected but GQ1b antibodies were not detected. To define neuromuscular involvement we performed electrodiagnostic studies. Single-fiber electromyography (SFEMG) in the extensor digitorum communis (EDC) showed abnormal jitter and axonal blocking, suggesting terminal axon dysfunction. Subsequent GQ1b antibody titers were elevated to borderline levels. Clinical symptoms gradually resolved. SFEMG may help characterize neuropathies associated with antibodies to neuronal ganglioside and identify involvement of the terminal axon and neuromuscular junction.

Axons↗

Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis.

The goal of this study was to estimate the accuracy of concentric-needle single-fiber electromyography (CN-SFEMG) for the diagnosis of myasthenia gravis (MG). A consecutive series of patients referred for CN-SFEMG was evaluated by an investigator blinded to the results of CN-SFEMG in order to determine the presence or absence of MG using an independent reference standard. Sensitivity, specificity, predictive values, and likelihood ratios were calculated. The study population included 51 patients (21 with MG). CN-SFEMG was normal in 34 patients (67%) and abnormal in 17 (33%). The sensitivity of CN-SFEMG for the diagnosis of MG was 0.67 and the specificity was 0.96. The positive likelihood ratio was 16.8 and the negative likelihood ratio was 0.34. The positive and negative predictive values were 0.93 and 0.76, respectively. These results indicate that CN-SFEMG showing abnormal jiggle is extremely useful for confirming the diagnosis of MG, but that CN-SFEMG showing normal jiggle has limited utility in excluding the diagnosis.

Action Potentials↗

Survey of electrodiagnostic laboratories regarding hemorrhagic complications from needle electromyography.

Little is known about the complications of needle electromyography (EMG) performed on anticoagulated patients, and no guidelines exist regarding its performance. We conducted an anonymous survey of academic EMG laboratories in the U.S. to understand current practices and complications with regard to anticoagulated patients and those receiving antiplatelet medications. Forty-seven (78%) of 60 EMG laboratories responded to the survey. Four laboratories (9%) reported at least one hemorrhagic complication requiring medical or surgical intervention in an anticoagulated patient, whereas none reported a hemorrhagic complication in patients receiving antiplatelet medications. Ten (21%) reported willingness to evaluate cranial, paraspinal, and all limb muscles in anticoagulated patients. This survey suggests that hemorrhagic complications from needle EMG of anticoagulated patients are rare. It also suggests that needle EMG of patients receiving antiplatelet therapy is not associated with increased reports of hemorrhagic complications.

Academic Medical Centers↗

A new analytical method to diagnose congenital myasthenia with stimulated single-fiber electromyography.

Stimulated single-fiber electromyography (SSF-EMG) is useful to assess neuromuscular junction (NMJ) abnormalities in children. Conventionally mean consecutive difference (MCD) analysis measures the jitter for each muscle-fiber potential. We present a new algorithm that analyzes the entire SSF-EMG waveform. Cross-correlational coefficients (between 0-1.0) are calculated for consecutive pairs of 100 SSF-EMG waveforms obtained at each needle position in orbicularis oculi, and averaged. A lower normal limit (0.722, mean -3 SD) was established from 123 SSF-EMG samples in 10 adult control subjects, and applied to SSF-EMG data from 23 children referred for a suspected myasthenic syndrome. Results were compared with MCD analysis and related to the final clinical diagnosis. Our results showed that compared with conventional MCD measurement, the new algorithm had better specificity (87% vs. 53%) but similar sensitivity (88% for both). These findings indicate that the cross-correlational method is a useful predictor of NMJ dysfunction in children.

Adolescent↗

Needle electromyography of the rectus abdominis in patients with amyotrophic lateral sclerosis.

We examined the role of needle electromyography (EMG) of the rectus abdominis (RA) in assessing thoracic involvement in amyotrophic lateral sclerosis (ALS). Needle EMG of the RA was performed in 67 patients with sporadic ALS and 110 healthy controls. The presence of abnormal spontaneous activity, configuration of motor unit action potentials (MUAPs), and recruitment pattern of motor unit potentials were examined. In ALS patients, MUAPs in the RA were of prolonged duration, large amplitude, and showed increased prevalence of polyphasic waveforms compared to controls. Significant differences in MUAP parameters, presence of abnormal spontaneous potentials, and interference patterns were noted between ALS patients and controls. Additionally, we found that active denervation was more frequent in the RA of ALS patients with dyspnea than those without dyspnea. Thus, conventional needle EMG of the RA is a valuable electrophysiological method to assess clinical and subclinical involvement of thoracic lower motor neurons in patients with suspected ALS.

Action Potentials↗

Single-fiber electromyography during menstrual exacerbation and ovulatory suppression in MuSK antibody-positive myasthenia gravis.

We report a patient with muscle-specific tyrosine kinase (MuSK) antibody-positive myasthenia gravis who experienced worsening of myasthenic weakness associated with alterations in estrogen and progesterone levels during the administration of oral contraceptive therapy. Single-fiber electromyography was performed to document changes in neuromuscular transmission associated with the clinical exacerbation and subsequent resolution of the menstrual exacerbation and clinical improvement experienced with continuous monophasic oral contraceptive therapy. The potential long-term benefit of ovulatory suppression in MuSK antibody-positive myasthenia gravis is discussed.

Acetylcholine↗

Single fiber electromyography in chronic renal failure.

Nineteen patients with chronic renal failure receiving intermittent hemodialysis had single fiber electromyography studies of their extensor digitorum communis muscles. Jitter values were abnormal, more so in men than in women. The jitter abnormalities tended to improve after intermittent hemodialysis treatments lasting longer than 1 year.

Adult↗

Distinguishing paramyotonia congenita and myotonia congenita by electromyography.

Compound muscle action potential (CMAP) amplitudes, response to 2 Hz nerve stimulation, response to exercise and electromyographic needle electrode examination findings from the thenar muscles of two patients with paramyotonia congenita were compared with those from two patients with dominantly inherited myotonia congenita in warm (34 degrees C) and cold (20 degrees C) states. Cold induced a significant fall in CMAP amplitude, induced/worsened a significant decremental response to 2 Hz stimulation, and virtually abolished myotonia and voluntary recruitment of motor unit potentials in patients with paramyotonia congenita; none of these occurred in myotonia congenita. Though exercise induced a mild fall in CMAP amplitude in both groups, postexercise fibrillations occurred only in patients with paramyotonia congenita. These findings serve to distinguish these two entities in the clinical electromyography laboratory.

Adult↗

The effects of chronic muscular activity on age-related changes in single fiber electromyography.

Single fiber electromyography ( SFEMG ) of the extensor digitorum communis (EDC) muscle and nerve conduction studies were performed on healthy, active elderly men (66-77 years old) to assess age-related changes in neuromuscular physiology and the effect of long-term increased muscular activity on these changes. The following two groups were studied: a control group and a group composed of men with occupationally greater usage of hand extensors. Fiber density and mean jitter were essentially the same in both groups; however, in the hand-user group there was greater variability in mean jitter and a significant increase in the prevalence of potential pairs with increased jitter or blocking. In both groups, slower nerve conduction velocities and lower amplitudes of sensory and motor evoked potentials tended to correlate with increased jitter and fiber density. These electrophysiological changes in healthy aged men are consistent with an extremely mild process of nerve terminal denervation and reinnervation. Although long-term increased synaptic activity did not greatly alter the rate or extent of this process, it did produce a higher incidence of abnormal potential pairs and greater variability in mean jitter.

Aged↗

AAEE minimonograph #25: Single-fiber electromyography in myasthenia gravis.

Single-fiber electromyography (SFEMG) demonstrates abnormal jitter in virtually all (99%) patients with myasthenia gravis (MG). One muscle, the extensor digitorum communis, is abnormal in most patients with this disease, but to obtain the maximum diagnostic sensitivity, it may be necessary to examine other muscles, especially ones that are more involved clinically. There is no one muscle that will be more abnormal in every patient with MG. The muscle(s) to be tested must be selected based on the distribution of weakness in the individual patient. Abnormal jitter is also seen in diseases of nerve and muscle; these diseases must be excluded by other electrophysiologic and clinical examinations before diagnosing MG. If neuronal or myopathic disease is present, increased jitter does not indicate that MG is also present. However, if jitter is normal in a muscle with definite weakness, the weakness is not due to MG. When abnormal neuromuscular transmission has been demonstrated by repetitive nerve stimulation, the finding of abnormal jitter does not add to the diagnosis, though it may be useful in providing baseline values for comparison with the results of subsequent studies. SFEMG is most valuable clinically in the patient with suspected MG in whom other tests of neuromuscular transmission and antiacetylcholine receptor antibody titers are normal. Serial measurements of jitter can be useful in following the course of disease and in assessing the effect of treatment, but the results from these studies must always be interpreted in light of the overall clinical picture.

Autoantibodies↗

Single-fiber electromyography in experimental autoimmune myasthenia gravis.

The sensitivity of stimulated single-fiber electromyography in the detection of early abnormalities in neuromuscular transmission in experimental autoimmune myasthenia gravis (EAMG) was tested. Increased jitter and blocking were seen up to 3 weeks before clinical illness or decrement developed. Stimulation at 10 Hz appeared more sensitive in detection of abnormalities than stimulation at 3 or 5 Hz. Jitter values did not correlate with anti-Torpedo acetylcholine receptor (AChR), nor with anti-rat AChR antibody titer. No correlation was found between jitter and AChR loss or AChR-antibody complexes in muscle. It is concluded that, in addition to AChR loss and the presence of AChR-antibody complexes, other factors must determine the neuromuscular dysfunction in EAMG and possibly myasthenia gravis.

Animals↗

AAEM minimonograph #36: basic concepts of electricity and electronics in clinical electromyography.

Fundamental principles of electricity provide a basis for understanding the design and operation of electromyography equipment. An intuitive and quantitative explanation of charge, voltage, current, and impedance provides an introduction to the concepts of resistance, capacitance, and input impedance. These concepts form the basis for discussion of filters, amplifiers, electrodes, digital electronics, stimulators, and patient safety. The monograph assumes no specialized training in engineering or mathematics. The topics are discussed at an introductory level to provide understanding for readers with no electronics background and intuitive insight for more experienced readers.

Electric Conductivity↗

Stimulated single-fiber electromyography in Lambert-Eaton myasthenic syndrome.

The Lambert-Eaton myasthenic syndrome (LEMS) is an autoimmune disorder of neuromuscular transmission. Electrodiagnosis is confirmed by an increase in compound muscle action potential amplitude during high-frequency repetitive nerve stimulation or following brief exercise. We describe the results of stimulated single-fiber electromyography in 4 patients with disorders of neuromuscular transmission: LEMS (2), LEMS/myasthenia gravis (MG) overlap (1), and MG (1). Stimulated SFEMG was performed in the extensor digitorum communis muscle with axonal intramuscular suprathreshold stimulation at low and high rates. In all 4 patients, a rate dependence of jitter was found. In LEMS and LEMS/MG, jitter and blocking improved with high stimulation rates, as compared with the opposite effect in MG. We conclude that stimulated SFEMG is a valuable technique in the diagnosis of LEMS.

Aged↗

Needle electromyography of the diaphragm.

A method is described for performing needle electromyography of the diaphragm which is safe and causes little discomfort. It provides valuable information concerning neuropathies and myopathies which may affect the diaphragm, and complements information derived from phrenic nerve conduction studies. Firing patterns of motor unit potentials during spontaneous respiration identify upper motor neurone disorders causing respiratory insufficiency.

Action Potentials↗

Single fiber electromyography in myasthenia gravis during pregnancy.

We report the use of single fiber electromyography (SFEMG) to demonstrate changes in the physiologic abnormality of myasthenia gravis (MG) during pregnancy. A 23-year-old became pregnant 15 months after the onset of mild ocular weakness. On initial evaluation, SFEMG jitter measurements demonstrated a slight abnormality of neuromuscular transmission. There was no change in severity of clinical disease or jitter measurements until the third trimester, when she improved. Jitter measurements at that time were normal. Labor was normal and she delivered a normal male. Three days postpartum, myasthenic weakness recurred temporarily and jitter measurements showed worsening. At 16 days and 6 weeks postpartum, she had only minimal medial rectus weakness and jitter studies were normal. Three months postpartum, ocular symptoms recurred and jitter measurements were slightly abnormal. She continued to worsen, developing limb muscle and severe ocular muscle weakness at 4 months postpartum. She was treated with plasma exchange and thymectomy. Prednisone was added 2 months after thymectomy due to continued worsening and development of oropharyngeal weakness. Three years postpartum she was taking prednisone 10 mg every other day and had only slight weakness of neck flexors, and jitter studies were again normal.

Adult↗

Latex hypersensitivity following exposure to gloves during electromyography.

A case of a 7-year-old boy with myelodysplasia who developed a local acute hypersensitivity reaction after exposure to latex gloves during electromyography is presented. Anaphylaxis from latex gloves has been recently reported, especially in patients with myelodysplasia. Allergens from rubber gloves can be introduced under the skin during EMG and could cause local or systemic acute hypersensitivity reactions. Electromyographers should elicit a history to rule out rubber allergy and use vinyl gloves if suspicion of allergy exists.

Child↗

Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome. AAEM Quality Assurance Committee.

The sensitivity and specificity of nerve conduction studies (NCS's) and electromyography (EMG) for the diagnosis of carpal tunnel syndrome (CTS) were evaluated by a critical review of the literature. With a search of the medical literature in English through May 1991, 165 articles were identified and reviewed on the basis of six criteria of scientific methodology. The findings of 11 articles that met all six criteria and the results of 48 additional studies that met four or five criteria are presented. We concluded that median sensory and motor NCS's are valid and reproducible clinical laboratory studies that confirm a clinical diagnosis of CTS with a high degree of sensitivity and specificity. Clinical practice recommendations are made based on a comparison of the sensitivities of the several different median nerve conduction study (NCS) techniques.

Carpal Tunnel Syndrome↗

Single fiber electromyography of extraocular muscles: a sensitive method for the diagnosis of ocular myasthenia gravis.

We performed single fiber electromyography (SFEMG) in the superior rectus and levator palpebralis (SR-LP) muscles of 17 patients with pure ocular myasthenia gravis (MG) and 9 controls. Thirteen patients were also assessed with SFEMG in the orbicularis oculi (OO) muscle. All the MG patients but none of the control subjects showed abnormal SFEMG jitter in the SR-LP muscles. On the other hand, only 62% of the MG patients had abnormal SFEMG jitter in the OO muscle. The procedure was well tolerated by the patients, and complications were minor. We conclude that SFEMG of the SR-LP muscles is a safe and highly sensitive technique for the diagnosis of ocular MG.

Adult↗