Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults.

PURPOSE: Compare electroretinogram (ERG) responses to full-field stimuli recorded with corneal-contact and skin electrodes in healthy children and adults. METHOD: ERGs were recorded independently in two laboratories in children (aged 4-14 years) and adults (aged 20-62 years). A Burian-Allen (BA) electrode were used to test both children and adults in one laboratory. A Gold Foil (GF) electrode was used to test adults and skin electrodes to test children and adults in the other laboratory. Responses were recorded to full-field stimuli similar to those specified in the ISCEV Standard. Dark-adapted responses were also recorded over a 5 log unit range of stimulus energies. RESULTS: All ISCEV rod and cone responses were recorded in every subject with skin electrodes as well as with eye-contact electrodes. BA and GF amplitudes and latencies were similar for the majority of ISCEV responses. The waveform morphology of rod and cone skin electrode responses was similar to corneal electrode responses in children and adults. GF electrode responses were on average 4 to 5 times larger than skin electrode responses recorded in the same laboratory. After scaling skin electrode responses by 4.5 the distribution of response amplitudes was found to be similar to that for the eye-contact electrodes in both children and adults. Dark-adapted responses were recorded to all stimulus intensities in every subject with each type of electrode. B-wave S-R functions were evaluated by fitting the Naka-Rushton equation. Vmax was similar for BA and GF electrode responses and this was about 4 times greater than for skin electrode responses. Log (sigma) was similar for GF and skin electrodes but these differed significantly from the BA electrode. Vmax and log(sigma) were similar in adults and children for BA and skin electrode responses. CONCLUSION: ERGs to full-field stimuli can be recorded successfully with either eye-contact or skin electrodes.

Adolescent↗

Noninvasive electrodes for electrocochleography in the chinchilla.

This study compares noninvasive vs invasive electrodes for electrocochleography in chinchillas. Summating potential (SP) amplitude, action potential (AP) amplitude, and AP threshold, recorded with five types of noninvasive electrodes, were compared with simultaneous bulla recordings. Noninvasive electrodes included a needle electrode over the bulla, gold Tiptrode (Etymotic Research, Elk Grove Village, Ill), Enhancer I (Nicolet Instrument Corp, Madison, Wis), Coats (Lifetech Inc, Austin, Tex) electrode, and a locally constructed tympanic membrane (TM) electrode. Stimuli included 100-microsecond clicks and 6000-Hz tone bursts (with a 1 millisecond rise/fall time and a 5 millisecond plateau). Stimuli were initially presented at 110 dB peak equivalent sound pressure level for the clicks and 100 dB peak equivalent sound pressure level for the tone bursts. Intensity was then decreased in 10-dB decrements until no replicable AP activity was observed. The TM damping for the TM electrode was measured with 0.5, 1, 2, 4, and 6 kHz and click stimuli. The AP was clear and replicable for all electrodes used in the study, although the amplitude was substantially less for the noninvasive electrodes as opposed to the invasive electrode. The invasive electrode provided the largest amplitude SP recording, but SP could generally be clearly recorded with the needle electrode, Enhancer I, and the Coats electrode. The TM electrode and gold Tiptrode provided SP recordings less consistently. The AP threshold could be recorded with all the electrodes in the study and was generally within 10 dB of threshold recorded invasively. Electrode variables, including ease of electrode placement and potential injury, were examined. The Tiptrode and Enhancer I electrodes posed relatively few problems during placement.(ABSTRACT TRUNCATED AT 250 WORDS)

Action Potentials↗

Problems associated with the Z-fold region of defibrillation electrodes.

To examine performance failures of automatic external defibrillator (AED) self-adhesive electrodes, a retrospective analysis of patient reports and electrodes was conducted in a suburban emergency medical service (EMS) system. In all cases, only records from out-of-hospital cardiac arrests (OHCA) were used if the EMS was activated and an AED was used. Electrode failures were assessed as follows: 1) EMS staff returned defibrillation electrodes when they were unable to resolve repeated "Check Electrode" messages, and 2) an audit of selected records was used to determine the frequency of electrode problems during calls. Of 302 OHCA calls during the study period, 22 (7%) resulted in returned electrodes. Defects (cracks or faults) in the internal conductor were present in 37 (86%) of the 43 returned electrodes; 2 (5%) possessed dehydrated conductive gel, and in 4 (9%) electrodes no faults could be identified. Of the 21 complete sets of defective electrodes, 16 (76%) had faults in both electrodes. Chart review revealed at least one "check electrode" message occurring in 21 (60%) of 35 OHCA reports. The electrode checks were present for a total of over 83 min, representing 11% of the call times. Paramedics were required to change electrodes in 9 (26%) of the 35 cases, resolving the malfunction in all instances. Electrode malfunction appears to be a common prehospital problem; the conductor is responsible for the majority of electrode problems and is probably subjected to the most stress during storage and handling. More reliable, durable defibrillation electrodes are required for OHCA treatment. Other strategies for electrode storage and quality control are also discussed.

Electric Countershock↗

High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control.

The authors hypothesized that during RF ablation, the electrode to tissue interface temperature may significantly exceed electrode temperature in the presence of cooling blood flow and produce thrombus. In 12 anesthetized dogs, the skin over the thigh muscle was incised and raised to form a cradle that was superfused with heparinized canine blood (ACT > 350 s) at 37 degrees C. A 7 Fr, 4-mm or 8-mm ablation electrode containing a thermocouple was held perpendicular to the thigh muscle at 10-g contact weight. Interface temperature was measured at opposite sides of the electrode using tiny optical probes. RF applications (n = 157) were delivered at an electrode temperature of 45 degrees C, 55 degrees C, 65 degrees C, and 75 degrees C for 60 seconds, with or without pulsatile blood flow (150 mL/min). Without blood flow, the interface temperature was similar to the electrode temperature. With blood flow, the interface temperature (side opposite blood flow) was up to 36 degrees C and 57 degrees C higher than the electrode temperature using the 4- and 8-mm electrodes, respectively. After each RF, the cradle was emptied and the electrode and interface were examined. Thrombus developed without impedance rise at an interface temperature as low as 73 degrees C without blood flow and 80 degrees C with blood flow (11/16 RFs at 65 degrees C electrode temperature using 4 mm and 13/13 RFs at an electrode temperature of 55 degrees C using an 8-mm electrode with blood flow). With blood flow, interface temperature markedly exceeded the electrode temperature and the difference was greater with an 8-mm electrode (due to greater electrode cooling). In the presence of blood flow, thrombus occurred without an impedance rise at an electrode temperature as low as 65 degrees C with a 4-mm electrode and 55 degrees C with an 8-mm electrode.

Analysis of Variance↗

Comparison of the depth of the desiccated zone with selected vaporizing-cutting electrodes: a basic study in animals.

OBJECTIVE: To evaluate in an animal model the haemostatic efficacy of vaporizing-cutting (VC) electrodes recently developed for use in high-energy transurethral resection of the prostate (TURP). MATERIALS AND METHODS: Four VC electrodes were assessed for their haemostatic efficacy in the muscle and liver of pigs (in vitro) and dogs (in vivo). The devices tested were the roller-cutting and Vapor Cut (Karl Storz GmbH, Germany); the Wedge (Boston Scientific Corp., Boston, USA); and the Uroloop (Endocare Inc., Irvine, CA). In each the depth of the desiccated zone was compared with that produced by a standard cutting loop electrode. Each electrode was attached to a scanning system (developed previously) that allowed the electrode pressure on the tissue surface (in 3% sorbitol solution) and the running speed to be adjusted. The same generator was used with all devices. The tissue (muscle or liver) was cut by running the electrode over the surface at 200, 250 or 300 W, with the loop electrode used as the reference. After completing the procedure, the surgical wound and the surrounding tissue were dissected out and the depth of the heat-affected zone (HAZ, defined as the desiccated zone) measured. RESULTS: In pig muscle (stroke speed 5 mm/s) there was no significant difference in the depth of the HAZ between the four VC electrodes and the loop, or among the VC electrodes at any of the power levels tested. In pig liver (stroke speed 5 mm/s), the roller cutting and Vapor Cut electrodes produced a thicker HAZ than the loop at all power levels tested (P < 0.01). The Wedge electrode produced a significantly thicker HAZ than the loop at 200 and 300 W (P < 0.01). There were no significant differences in HAZ among the VC electrodes at any power level. In dog muscle in vivo (stroke speed 10 mm/s), the roller cutting, Vapor Cut and Wedge electrodes produced a significantly thicker HAZ at 250 W than the loop at 150 W (the usual power for TURP) (P < 0.01). There was no significant difference among the VC electrodes. In dog liver in vivo (stroke speed 10 mm/s), the roller cutting electrode produced a significantly thicker HAZ at 250 W than the loop at 150 W (P < 0.01). CONCLUSIONS: The present VC electrodes produced a thicker desiccation zone at higher powers (200-300 W) than the standard loop at the usual power (150 W). The four VC electrodes produced a similar desiccation zone. With pig muscle and liver in vitro, regular loops used at a higher power created a desiccation zone that was 70-80% of the depth created by the VC electrodes.

Animals↗

Electrode ranking of "place pitch" and speech recognition in electrical hearing.

The ability to distinguish electrical stimulation of different electrodes on the basis of "pitch or sharpness" was evaluated with an electrode ranking procedure in 14 individual users of the Nucleus cochlear implant. Prior to the electrode ranking test, absolute thresholds and maximum comfortable loudness levels were measured, and loudness balancing was accomplished across all usable electrodes. Performance on the electrode ranking task was defined in terms of d' per mm of distance between comparison electrodes. Large individual differences were found among cochlear-implant users. In subjects with good to excellent place-pitch sensitivity, the electrode ranking task was limited by a ceiling effect; however, in those with poor to moderate sensitivity d'/mm was relatively constant with spatial separation between electrodes. Place pitch was typically ordered from apical to basal electrodes, i.e., basal electrodes were judged to be higher in pitch than more apical electrodes. However, instances of reversals in place-pitch ordering were seen on some electrodes in some subjects. Instances were also seen of better electrode ranking in the apical half of the electrode array than in the basal half, and vice-versa. Analyses of the electrode ranking functions in terms of d' per stimulus indicated that, in some subjects, perfect performance was reached with as little as 0.75 mm between comparison electrodes, the minimum possible. In other subjects, perfect performance was not reached until the spatial separation between comparison electrodes was over 13 mm, more than three quarters of the entire length of the electrode array. Ten of the subjects also participated in a closed-set recognition task of intervocalic consonants. Although the maximum transmitted information for place of consonant articulation (which is based primarily on spectral speech cues) was only 34%, correlations between place-pitch sensitivity and transmitted speech information were as high as 0.71. This was surprising considering the excellent place-pitch sensitivity exhibited by some of the subjects, and may reflect limitations of the Nucleus speech coding strategy for representing spectrally coded speech information. The two prelingual subjects performed notably poorer on the speech task than the postlingual subjects, even though one of the prelingual subjects demonstrated very good place-pitch sensitivity.

Adult↗

Amplitude scaling relationships of Burian-Allen, gold foil and Dawson, Trick and Litzkow electrodes.

The bipolar Burian-Allen electrode represents the International Society for Clinical Electrophysiology of Vision standard for recording the electroretinogram. With prolonged recording there is a high risk of corneal abrasion from the electrode, while alternatives such as gold foil electrodes or fibers represent less risk. The standards require that alternative electrodes be demonstrated to give equivalent waveform and amplitudes. Electroretinograms were recorded with the bipolar Burian-Allen electrode and four alternative electrode configurations: a unipolar Burian-Allen electrode, a bipolar and monopolar gold foil electrode and a Dawson, Trick and Litzkow fiber electrode with all other recording conditions identical. The results represent a guide for comparisons of electroretinograms between studies using these electrodes. Recordings were made from two subjects for all five electrode configurations and six additional subjects with unipolar gold foil and bipolar gold foil electrodes alone. Flash stimuli over a range of intensities from full intensity to -1.5 log units were used. Recordings were repeated in the one session and on a subsequent session to provide test-retest reliabilities. Significant (p < 0.0001) differences in b-wave amplitude resulting from electrode type and intensity were demonstrated. The unipolar Burian-Allen and unipolar gold foil electrodes produced the greatest amplitude responses. The alternatives to the bipolar Burian-Allen electrode were equally or more reliable. The Dawson, Trick and Litzkow electrode produced lower-amplitude response than the bipolar Burian-Allen electrode but was the only one with significantly greater between-session reliability.

Analysis of Variance↗

Layperson positioning of defibrillation electrodes guided by pictorial instructions.

BACKGROUND: Correct positioning of defibrillation electrodes is essential to achieve sufficient transmyocardial current to depolarize a critical mass of myocardium, and thus terminate ventricular fibrillation (VF). AIM: To evaluate the pictures on the self-adhesive defibrillation electrodes in guiding laypersons to place the electrodes in the recommended position. METHODS: Defibrillation electrodes from five manufactures (Access Cardio Systems, Schiller, Medtronic, Cardiac Science and Philips) were included in the study and compared with electrodes with a lateral view picture, designed for the study, showing the placement of the apical electrode. A total of 150 laypersons without any experience or training in use of a defibrillator participated in the study. The participants placed randomly selected electrodes on the chest of a resuscitation manikin without any guidance apart from the pictures on the electrodes. The distances of the electrodes from the recommended positions were measured. RESULTS: The proportion of participants who placed both electrodes within 5 cm from recommended position varied from 8% to 36% with the different electrodes. Usually, the apical electrode was placed too anteriorly. Electrodes placed with help of the lateral instruction picture, (designed for the study), showing the placement of the apical electrode were placed significantly more often within 5 cm than any of the others (64%, 95% confidence interval 44-80, P < 0.05). CONCLUSIONS: The current practice in designing pictures on the electrodes does not seem to be optimal in showing the recommended position of the apical electrode as recommended by Guidelines 2000. It is suggested that by showing a lateral view in the instructions, success in placing the apical electrodes correctly can be improved.

Adolescent↗

Clinical use of percutaneous intramuscular electrodes for functional electrical stimulation.

OBJECTIVE: To evaluate the clinical use of the percutaneous intramuscular electrode in functional electrical stimulation (FES). DESIGN: Randomized and controlled study. SETTING: A referral center and institutional practice providing outpatient care. PATIENTS: Seventeen patients (12 men, 5 women) who had implanted percutaneous intramuscular electrodes for more than 1 year were examined. The average follow-up time after implantation of electrodes was 2.2 years (range, 1yr to 4yr 10mo). Overall, there were 327 electrodes (83 upper extremities and 244 lower extremities). INTERVENTION: The indwelling electrode was composed of helically coiled Teflon-coated rope stranded from 19 hard drawn wires of SUS 316L stainless steel (SES 114). MAIN OUTCOME MEASURES: The rates of breakage, movement, and infection, and the number of electrodes that needed reimplantation were evaluated. RESULTS: Only one electrode broke (0.3%) in the iliopsoas muscle at 12 weeks after implantation. Eight electrodes (2.4%) were removed because of loss of sufficient contraction force caused by movement of the electrodes. Movements occurred at 9 weeks in 6 electrodes and at 5 months in two. The failure rate of electrodes in the lower extremities was 3.7%. No failures occurred in the upper extremities. Ten electrodes (3.1%) required reimplantation. Although ten superficial infections (3.1%) were seen around the site of electrode insertion, no removals of electrode were needed. All electrodes in one patient were removed, however, because of generalized methicillin-resistant Staphylococcus aureus infection complicated with renal disease. Electrodes were reimplanted after improvement of the infection. CONCLUSIONS: The ultrafine percutaneous intramuscular electrode was considered practical for long-term FES use.

Adult↗

Biophysics of radiofrequency ablation using an irrigated electrode.

BACKGROUND: Previous reports have proposed that prevention of electrode-endocardial interfacial boiling is the key mechanism by which radiofrequency application using an irrigated electrode yields a larger ablation lesion than a non-irrigated electrode. It has been suggested that maximal myocardial temperature is shifted deep into myocardium during irrigated ablation. PURPOSE: To examine the biophysics of irrigated ablation by correlating electrode and myocardial temperatures with ablation circuit impedance and lesion morphology, and to perform a comparison with non-irrigated ablation modes. To assess the influence of irrigant rate, composition, temperature and blood flow velocity. METHODS: I. Ablation with and without electrode irrigation was performed in vitro utilizing a whole blood-superfused system. Electrode, electrode-endocardial interface, and intramyocardial temperatures were assessed, as were ablation circuit impedance, total delivered energy, and lesion and electrode morphology. Irrigants assessed were room temperature normal saline, iced normal saline, and dextrose. Irrigant flow rates assessed were 20 and 100 cc/min. Blood flow velocities assessed were 0 and 0.26 m/s. II. Finite element simulations of myocardial temperature during irrigated ablation were performed to further elucidate irrigation biophysics and provide a more detailed myocardial temperature profile. Two models were constructed, each utilizing a different core assumption regarding the electrode-tissue boundary: 1. electrode temperature measured in vitro; 2. interfacial temperature measured in vitro. Intramyocardial temperatures predicted by each model were correlated with corresponding temperatures measured in vitro. RESULTS: I. Ablation during electrode irrigation with normal saline was associated with greater ablation energy deposition and larger lesion dimensions than non-irrigated ablation. The mechanism underlying the larger lesion was delay or inhibition of impedance rise; this was associated with attenuation or prevention of electrode coagulum. Irrigation did not prevent interfacial boiling, which occurred during uninterrupted radiofrequency energy deposition and lesion growth. Irrigation using saline at 100 cc/min was associated with no impedance rise regardless of blood flow velocity, whereas during irrigation at 20 cc/min impedance rise was blood flow rate-dependent. Iced saline produced results equivalent to room temperature saline. Irrigation with dextrose was associated with curtailed energy application and relatively small lesions. II. The finite element simulation that used electrode-endocardial interfacial temperature as the core assumption predicted a myocardial temperature profile which correlated significantly better with in vitro than did the simulation which used electrode temperature as the core assumption. Regardless of irrigant and blood flow rates, maximal myocardial temperature was always within 1 mm of the endocardial surface. CONCLUSIONS: Radiofrequency energy application via a saline irrigated electrode resulted in a larger lesion due to attenuation or eradication of electrode coagulum, thus preventing an impedance rise. Irrigation did not prevent interfacial boiling, but boiling did not prevent lesion growth. The site of maximal myocardial temperature during irrigated ablation was relatively superficial, always within 1 mm of the endocardial surface. Irrigation with iced saline was no more effective than with room temperature saline; both were far more effective than dextrose. Higher irrigation rates immunized the electrode from the influence of blood flow. The biophysical effects of blood flow and irrigation were similar.

Animals↗

Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model.

PURPOSE: A multiple-electrode radiofrequency (RF) system was developed based on switching between electrodes that allows for the simultaneous use of as many as three electrically independent electrodes. The purpose of this study was to determine if each multiple-electrode ablation zone is identical to an ablation zone created with conventional single-electrode mode. MATERIALS AND METHODS: Nine female domestic pigs (mean weight, 90 kg) were used for this study. A prototype monopolar multiple-electrode RF ablation system was created with use of an RF generator and an electronic switching algorithm. A maximum of three electrodes can be used simultaneously by switching between electrodes at each impedance spike (30 omega greater than baseline levels). A total of 39 zones of ablation were created at open laparotomy in pig livers with use of a conventional single electrode (n = 9), two single electrodes simultaneously (n = 6 ablations; 12 ablation zones), or three single electrodes simultaneously (n = 6 ablations; 18 ablation zones). RF electrodes were spaced in separate lobes of the liver when multiple zones of coagulation were created simultaneously. Animals were euthanized after RF ablation, livers were removed, and ablation zones were sectioned and measured. RESULTS: Zones of coagulation created simultaneously with two or three electrodes were equivalent to ablation zones created with use of conventional single-electrode ablation. No significant differences were observed among control animals treated with a single electrode, those with two separate zones of ablation created simultaneously, and those with three simultaneously created ablation zones in terms of mean (+/-SD) minimum diameter (1.6 cm +/- 0.6, 1.6 cm +/- 0.5, and 1.7 cm +/- 0.4, respectively), maximum diameter (2.0 cm +/- 0.5, 2.3 cm +/- 0.5, 2.2 cm +/- 0.5, respectively), and volume (6.7 cm3 +/- 3.7, 7.4 cm3 +/- 3.8, and 7.8 cm3 +/- 3.9; P > .30, analysis of variance, pairwise t-test comparisons). CONCLUSIONS: A rapid-switching multiple-electrode RF system was able to simultaneously create as many as three separate ablation zones of equivalent size compared with single-electrode controls. This system would allow physicians to simultaneously treat multiple tumors, substantially reducing procedure time and anesthesia risk.

Algorithms↗

Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation.

BACKGROUND: It is thought that only a thin layer of tissue adjacent to the electrode is heated directly by electrical current (resistive heating) during radiofrequency ablation. Most of the thermal injury is thought to result from conduction of heat from the surface layer. The purpose of this study was to determine whether lesion depth could be increased by producing direct resistive heating deeper in the tissue with higher radiofrequency power, allowed by cooling the ablation electrode with saline irrigation to prevent the rise in impedance that occurs when the electrode-tissue interface temperature reaches 100 degrees C. METHODS AND RESULTS: In 11 anesthetized dogs, the thigh muscle was exposed and bathed with heparinized canine blood (36 degrees C to 37 degrees C). A 7F catheter, with a central lumen, a 5-mm tip electrode with six irrigation holes, and an internal thermistor, was positioned perpendicular to the thigh muscle and held at a constant contact weight of 10 g. Radiofrequency current was delivered to 145 sites (1) at high constant voltage (66 V) without irrigation (CV group, n = 31), (2) at variable voltage (20 to 66 V) to maintain tip-electrode temperature at 80 degrees C to 90 degrees C without irrigation (temperature-control group, n = 39), and (3) at high CV (66 V) with saline irrigation through the catheter lumen and ablation electrode at 20 mL/min (CV irrigation group, n = 75). Radiofrequency current was applied for 60 seconds but was terminated immediately in the event of an impedance rise > or = 10 omega. Tip-electrode temperature and tissue temperature at depths of 3.5 and 7.0 mm were measured in all three groups (n = 145). In 33 CV irrigation group applications, temperature was also measured with a separate probe at the center (n = 18) or edge (n = 15) of the electrode-tissue interface. In all 31 CV group applications, radiofrequency energy delivery was terminated prematurely (at 11.6 +/- 4.8 seconds) owing to an impedance rise associated with an electrode temperature of 98.8 +/- 2.1 degrees C. All 39 temperature-control applications were delivered for 60 seconds without an impedance rise, but voltage had to be reduced to 38.4 +/- 6.1 V to avoid temperatures > 90 degrees C (mean tip-electrode temperature, 84.5 +/- 1.4 degrees C). In CV irrigation applications, the tip-electrode temperature was not > 48 degrees C (mean, 38.4 +/- 5.1 degrees C) and the electrode-tissue interface temperature was not > 80 degrees C (mean, 69.4 +/- 5.7 degrees C). An abrupt impedance rise with an audible pop and without coagulum occurred in 6 of 75 CV irrigation group applications at 30 to 51 seconds, probably owing to release of steam from below the surface. In the CV and temperature-control group applications, the temperatures at depths of 3.5 (62.1 +/- 15.1 degrees C and 67.9 +/- 7.5 degrees C) and 7.0 mm (40.3 +/- 5.3 degrees C and 48.3 +/- 4.8 degrees C) were always lower than the electrode temperature. Conversely, in CV irrigation group applications, electrode and electrode-tissue interface temperatures were consistently exceeded by the tissue temperature at depths of 3.5 mm (94.7 +/- 9.1 degrees C) and occasionally 7.0 mm (65.1 +/- 9.7 degrees C). Lesion dimensions were smallest in CV group applications (depth, 4.7 +/- 0.6 mm; maximal diameter, 9.8 +/- 0.8 mm; volume, 135 +/- 33 mm3), intermediate in temperature-control group applications (depth, 6.1 +/- 0.5 mm; maximal diameter, 11.3 +/- 0.9 mm; volume, 275 +/- 55 mm3), and largest in CV irrigation group applications (depth, 9.9 +/- 1.1 mm; maximal diameter, 14.3 +/- 1.5 mm; volume, 700 +/- 217 mm3; P < .01, respectively). CONCLUSIONS: Saline irrigation maintains a low electrode-tissue interface temperature during radiofrequency application at high power, which prevents an impedance rise and produces deeper and larger lesions. A higher temperature in the tissue (3.5 mm deep) than at the electrode-tissue interface indicates that direct resistive heating occurred deeper

Animals↗

Nonuniform heating during radiofrequency catheter ablation with long electrodes: monitoring the edge effect.

BACKGROUND: Long, narrow electrodes are being considered for radiofrequency ablation of atrial fibrillation; however, preliminary work revealed coagulum formation on the electrodes and lack of lesion continuity. This may be due to the "edge effect," which concentrates radiated energy at sharp geometric gradients. It is proposed that temperature sensors at electrode edges are preferable to a single centered sensor for temperature feedback and monitoring of long electrode geometries. METHODS AND RESULTS: A finite element model was used to predict the heating properties of new long electrode geometries. Sixteen dogs with atrial fibrillation underwent left and right atrial ablation using catheters with multiple 12.5-mm coil electrodes. Electrodes with a single thermistor were compared with electrodes with dual thermocouples placed at opposite ends and on opposing sides of the electrode. Power, temperature, and impedance were recorded for all lesions, and coagulum adhesion and magnitude were noted in a subset of lesions. Finite element analysis shows uneven heating, with the main heating concentrated at the electrode edges and a propensity toward temperatures >100 degrees C with single-thermistor feedback control. Ablations with dual thermocouple electrodes achieved higher measured temperatures at lower power levels than those that used single-thermistor electrodes. Impedance rises and coagulum adherence occurred less frequently with dual thermocouple electrodes than with single, centered thermistor electrodes (176 of 395 versus 9 of 425 lesions; P<.0001; 46 of 98 versus 7 of 150 lesions; P<.0001, respectively). CONCLUSIONS: Maximum heating from radiofrequency energy occurs at the electrode edges, particularly with long electrodes. The safety of temperature-feedback atrial ablation with these electrodes is significantly improved by monitoring temperatures at the edges.

Animals↗

Transvenous-subcutaneous defibrillation leads: effect of transvenous electrode polarity on defibrillation threshold.

INTRODUCTION: The defibrillation threshold (DFT) of a transvenous-subcutaneous electrode configuration is sometimes unacceptably high. To obtain a DFT with a sufficient safety margin, the defibrillation field can be modified by repositioning the electrodes or more easily by a change of electrode polarity. In a prospective randomized cross-over study, the effect of transvenous electrode polarity on DFT was evaluated. METHODS AND RESULTS: In 21 patients receiving transvenous-subcutaneous defibrillation leads, the DFT was determined intraoperatively for two electrode configurations. Two monophasic defibrillation pulses were delivered in sequential mode between either the right ventricular (RV) electrode as common cathode and the superior vena cava (SVC) and subcutaneous electrodes as anodes (configuration I) or the SVC electrode as common cathode and the RV and subcutaneous electrodes as anodes (configuration II). In each patient, both electrode configurations were used alternately with declining energies (25, 15, 10, 5, 2 J) until failure of defibrillation occurred. The DFT did not differ between both configurations (18.3 +/- 8.2 J vs 18.9 +/- 8.9 J; P = 0.72). Eleven patients had the same DFT with both electrode configurations, 5 patients a lower DFT with the RV electrode as cathode, and 5 patients a lower DFT with the SVC as cathode. Four patients had a sufficiently low DFT (< or = 25 J) with only 1 of the 2 configurations. CONCLUSION: A change of electrode polarity of transvenous-subcutaneous defibrillation electrodes may result in effective defibrillation if the first electrode polarity tested fails to defibrillate. In general, neither the RV electrode nor the SVC electrode is superior if used as a common cathode in combination with a subcutaneous anodal chest patch.

Adult↗

External cardiac pacing using low impedance electrodes suitable for defibrillation: a comparative blinded study.

OBJECTIVES: The objective of this study was to determine whether the threshold for successful cardiac pacing is affected by electrode impedance and whether this procedure can be successfully carried out through low impedance electrodes that are also suitable for defibrillation. BACKGROUND: Reintroduced in the early 1980s, external cardiac pacing utilizes large externally placed electrodes with a high impedance, in conjunction with a stimulator capable of producing an impulse of 20 to 40 ms in duration. On the basis of empiric observation, high impedance electrodes (> 500 omega) are believed to be optimal for external cardiac pacing. Such electrodes are unsuitable for defibrillation, a technique that is most successful when impedance is low. In view of the absence of controlled data to support this recommendation, as well as the desirability of using one set of electrodes for both pacing and defibrillation, we undertook the following study. METHODS: Thirty-two normal subjects underwent a total of 110 attempts at external cardiac pacing with either (or both) high or low impedance electrodes in combination with one or two commercially available external cardiac pacemakers. Each subject underwent pacing at least twice in a randomized double-blind fashion to determine the pacing threshold and level of discomfort. RESULTS: Individual subjects had a wide range of pacing thresholds but did not experience any greater discomfort with one pacemaker-electrode combination than with any other. Similarly, no pacemaker-electrode combination was superior to another in terms of pacing thresholds. The mean pacing threshold was 72.5 +/- 6 mA for the 40-ms impulse/high impedance electrode combination, 78.7 +/- 6 mA for the 40-ms impulse/low impedance electrode, 73.8 +/- 7 mA for the 20-ms impulse/high impedance electrode and 77.5 +/- 7 mA for the 20-ms impulse/low impedance electrode (p = NS for all comparisons). CONCLUSIONS: Contrary to previous belief, a high impedance electrode offers no advantage for external pacing in terms of either pacing threshold or discomfort level during pacing. This study demonstrates that it is feasible to perform external pacing through an electrode that is also suitable for defibrillation and suggests that a single external pacing-defibrillation electrode is all that is needed to perform these two procedures.

Adult↗

Effects of electrode properties on EEG measurements and a related inverse problem.

A trend in EEG measurements is to increase the number of measurement electrodes in order to improve the spatial resolution of the recorded voltage distribution at the scalp. It is assumed that this would implicate better accuracy in the EEG inverse estimates. However, this does not necessarily hold. The reason for this is that the electrodes create a well conducting shunting "layer" on the scalp which affects the voltage distribution. This may decrease the information obtained and may therefore worsen the inverse estimates. Electrodes in EEG inverse problems are commonly modeled as point electrodes. This model cannot take into account the possible shunting effect of the electrodes. In this study the measurement electrodes are modeled using the so-called complete electrode model which takes into account the actual size of the electrode, the contact impedance between the skin and the electrode and also the shunting effect of the electrodes. In this paper the effects of the electrode size and the contact impedance on the voltage distribution are studied by simulations. It is shown that, depending on the size and the contact impedance of the electrodes, increasing the number of electrodes does not necessarily improve the accuracy of the inverse estimates. We also conclude that the use of the point electrode model is quite adequate in normal EEG studies. The use of a complete electrode model is necessary if electrodes cover more than 50% of the surface area.

Electric Impedance↗

Current density distributions, field distributions and impedance analysis of segmented deep brain stimulation electrodes.

Deep brain stimulation (DBS) electrodes are designed to stimulate specific areas of the brain. The most widely used DBS electrode has a linear array of 4 cylindrical contacts that can be selectively turned on depending on the placement of the electrode and the specific area of the brain to be stimulated. The efficacy of DBS therapy can be improved by localizing the current delivery into specific populations of neurons and by increasing the power efficiency through a suitable choice of electrode geometrical characteristics. We investigated segmented electrode designs created by sectioning each cylindrical contact into multiple rings. Prototypes of these designs, made with different materials and larger dimensions than those of clinical DBS electrodes, were evaluated in vitro and in simulation. A finite element model was developed to study the effects of varying the electrode characteristics on the current density and field distributions in an idealized electrolytic medium and in vitro experiments were conducted to measure the electrode impedance. The current density over the electrode surface increased towards the edges of the electrode, and multiple edges increased the non-uniformity of the current density profile. The edge effects were more pronounced over the end segments than over the central segments. Segmented electrodes generated larger magnitudes of the second spatial difference of the extracellular potentials, and thus required lower stimulation intensities to achieve the same level of neuronal activation as solid electrodes. For a fixed electrode conductive area, increasing the number of segments (edges) decreased the impedance compared to a single solid electrode, because the average current density over the segments increased. Edge effects played a critical role in determining the current density distributions, neuronal excitation patterns, and impedance of cylindrical electrodes, and segmented electrodes provide a means to increase the efficiency of DBS.

Animals↗

The porous endocardial electrode.

The permanent endocardial electrode has exhibited the problems of dislodgement, excessive threshold rises and loss of sensing. These failure modes are addressed with a new electrode incorporating a porous body of Pt-Ir fibers with a fiber diameter of 20 micrometers and an overall density of 10%. Porous electrodes have the advantages of utilizing the electrode interior both for tissue ingrowth to improve anchoring and for electrolyte penetration which improves R wave amplitude and reduces polarization losses. A series of 20 porous electrodes was compared with 17 solid electrodes of similar dimension. Electrodes were implanted in dogs in the apex of the right ventricle, and were subsequently followed up to 210 days. Comparison of the electrode data revealed that the porous electrodes had a 40% reduction in chronic voltage thresholds and had an overall dislodgement rate of 10%, compared to 53% for the solid electrodes. Histological examination revealed tissue ingrowth throughout the electrode interior and a fibrotic capsule about half the thickness of the solid electrodes. R wave stability was enhanced with the porous electrode due to improved anchoring, reduction in slew rate changes and less R wave attenuation. Assuming results are translatable to humans, the porous electrode will provide a greater pacing safety margin when used with a standard demand pacemaker, or improved longevity with the same safety margin as solid electrodes if used with a programmable pacemaker. The incidence of dislodgement and sensing failure will also be diminished with the porous electrode.

Animals↗