Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capillaries”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Capillary liquid chromatography of multiple peptides with on-line capillary electrophoresis immunoassay detection.

A competitive immunoassay for neuropeptide Y (NPY) based on capillary electrophoresis (CE) with laser-induced fluorescence detection was developed utilizing polyclonal antisera as the immunoreagent and fluorescein-labeled NPY as the tracer. The assay was performed with on-line mixing of reagents, automated injections, and a 3 s separation time. The assay had a detection limit of 850 pM. To detect NPY at lower concentrations, the assay was coupled on-line to reversed-phase capillary liquid chromatography (LC). In this arrangement, 5 microL samples were preconcentrated by capillary LC and eluted by a gradient of isopropanol-containing mobile phase. The resulting chromatographic peaks were monitored by the CE immunoassay. With preconcentration, the concentration detection limit was improved to 40 microM and NPY could be measured in push-pull perfusion samples collected from the paraventricular nucleus of freely moving rats. The technique was extended to simultaneous detection of NPY and glucagon secretion from islets of Langerhans.

Chromatography, Liquid↗

Surfactant-mediated capillary electrochromatography with octadecyl-silica- packed capillary columns for the separation of nonpolar compounds. Case of pyrethroid insecticides.

Capillary electrochromatography (CEC) with octadecyl-silica-packed capillary columns was evaluated in the separation of nonpolar compounds, e.g., pyrethroid insecticides, using surfactant-rich mobile phases. This novel concept is referred to as surfactant-mediated capillary electrochromatography (SM-CEC), and is based on including a charged surfactant, namely sodium di-2-ethylhexyl sulfosuccinate (DOSS), in the mobile phase. Under these conditions, DOSS plays the role of a slowly moving pseudostationary phase so that solutes are partitioned between a mobile phase, a fixed stationary phase and a slowly moving pseudostationary phase. The SM-CEC system was investigated with pyrethroid insecticides over a wide range of DOSS and acetonitrile concentrations in the mobile phase. Pyrethroid insecticides, which are very hydrophobic solutes consisting of geometric isomers and diastereomers, were better resolved in SM-CEC than in straight CEC.

Acetonitriles↗

Open-tubular capillary electrochromatography using capillary columns chemically bonded with the new host molecules calix[6]crown, calix[6]arene.

Two host molecules, p-tert-butylcalix[6]-1,4-crown-4 and p-tert-butylcalix[6]arene were prepared and attached onto the inner surfaces of capillaries for open-tubular electrochromatography with the aid of gamma-glycidoxypropyl-trimethoxysilane (KH-560) as bridging agent. The successful bonding was confirmed by infrared (IR) results and greatly decreased electroosmotic flow (EOF). Parameters affecting separation, such as buffer pH and organic modifier were studied. The two novel stationary phases were evaluated by the separation of isomeric toluidines, a mixture of pyridine and isomeric picolines, and isomeric dihydroxybenzenes; comparisons between capillaries coated with the two stationary phases and bare capillary were investigated. The special selectivity of these two novel stationary phases showed a certain extent of supramolecular interactions between stationary phases and solutes.

Calixarenes↗

In-capillary derivatization and analysis of amino acids, amino phosphonic acid-herbicides and biogenic amines by capillary electrophoresis with laser-induced fluorescence detection.

This paper describes a general approach for the in-capillary derivatization of amino compounds and the subsequent sensitive determination of the derivatives by micellar electrokinetic chromatography (MEKC) or capillary zone electrophoresis (CZE) with laser-induced fluorescence (LIF) detection. Amino acids, biogenic amines and amino phosphonic acid-herbicides were chosen as model analytes to evaluate the analytical potential of this approach. Fulfilment of the in-capillary reaction of the analytes using LIF detection hinged on the excellent labeling chemistry of 5-(4,6-dichloro-s-triazin-2-ylamino)fluorescein (DTAF) and the good resolution achieved in the separation of derivatized analytes. Careful optimization of the electrophoretic conditions in the mixing step of this protocol allowed the determination of amino acids, biogenic amines and phosphorus-containing amino acid-herbicides with concentration limits of detection at the nug/L level and relative standard deviations from 3.5 to 5.8%. The whole analysis is carried out within 20 min, resulting in a very simple, fast and practical approach for the fully automated analysis of amino acids and related compounds in low-volume and low-concentration samples.

Amino Acids↗

Joule heating in packed capillaries used in capillary electrochromatography.

Effective heat dissipation is critical for reproducible and efficient separations in electrically driven separation systems. Flow rate, retention kinetics, and analyte diffusion rates are some of the characteristics that are affected by variation in the temperature of the mobile phase inside the column. In this study, we examine the issue of Joule heating in packed capillary columns used in capillary electrochromatography (CEC). As almost all commonly used CEC packings are poor thermal conductors, it is assumed that the packing particles do not conduct heat and heat transfer is solely through the mobile phase flowing through the system. The electrical conductivity of various mobile phases was measured at different temperatures by a conductivity meter and the temperature coefficient for each mobile phase was calculated. This was followed by measurement of the electrical current at several applied voltages to calculate the conductivity of the solution within the column as a function of the applied voltage. An overall increase in the conductivity is attributed to Joule heating within the column, while a constant conductivity means good heat dissipation. A plot of conductivity versus applied voltage was used as the indicator of poor heat dissipation. Using theories that have been proposed earlier for modeling of Joule heating effects in capillary electrophoresis (CE), we estimated the temperature within CEC columns. Under mobile and stationary phase conditions typically used in CEC, heat dissipation was found to be not always efficient. Elevated temperatures within the columns in excess of 23 degrees C above ambient temperature were calculated for packed columns, and about 35 degrees C for an open column, under a given set of conditions. The results agree with recently published experimental findings with nuclear magnetic resonance (NMR) thermometry, and Raman spectroscopic measurements.

Buffers↗

Rapid loading of large sample volumes, analyte cleanup, and modified moving boundary transient isotachophoresis conditions for membrane preconcentration-capillary electrophoresis in small diameter capillaries.

Using a removable membrane preconcentration (mPC) cartridge, large sample volumes can be loaded prior to final assembly of the mPC capillary electrophoresis (CE) capillary. For narrow-bore (< or = 25 microns ID) uncoated mPC-CE capillaries, applied to peptide analysis, efficient moving boundary transient isotachphoresis (tITP) conditions at the onset of electrophoresis are described. The enhancement of mPC-CE-mass spectrometry (MS) technology afforded by rapid sample loading and modified moving boundary tITP conditions are demonstrated by analysis of major histocompatibility complex (MHC) class I peptides that were derived from a Kb precipitation of mouse EL-4 cells. Furthermore, we demonstrate the structural characterization of these immunologically significant molecules by mPC-CE-tandem mass spectrometry (mPC-CE-MS/MS).

Amino Acid Sequence↗

Linearity evaluation in absorbance detection: the use of light-emitting diodes for on-capillary detection in capillary electrophoresis.

A model which takes into account both stray light and polychromatic light was used to predict and evaluate linearity in on-capillary detection in capillary electrophoresis (CE). According to the model the stray light is the major factor which determines linearity under typical CE operating conditions. By calculating theoretical absorbance versus concentration plots, the influence of different levels of stray light and polychromatic light on linearity is demonstrated. Experimentally, six light-emitting diodes (LEDs) in the range from 563 to 654 nm were examined as light sources for on-capillary detection in CE. Fitting theoretical curves to measured linearity plots enabled determination of the values of both effective path length and stray light for a particular detection system. The detector linearity for the four LEDs was compared to mercury and tungsten lamps used with interference filters. For potassium permanganate as the test compound, the linear range for a 563 nm LED was two times greater than that for a mercury lamp operated at 546 nm. The relatively poor linearity of the mercury lamp detector is explained by its high level of stray light. The noise of the LED563-based detector was the same as for the mercury lamp, whereas the other LEDs of higher light intensity gave approximately half the noise of the mercury lamp. The lowest noise level of 3 x 10(-5) AU was obtained for the LED at 554 nm (determined at a detector time constant of 0.1 s).

Electrophoresis, Capillary↗

Capillary electrophoresis and capillary electrophoresis-electrospray-mass spectroscopy for the analysis of heterocyclic amines.

Fourteen heterocyclic amines (HAs) were analyzed by capillary electrophoresis (CE) on a polyvinyl alcohol (PVA)-coated capillary column. The optimized electrolyte is composed of 20 mM ammonium acetate, pH 3.0, and 20% methanol. Similar conditions were applied in electrospray-mass spectrometry (CE-ES-MS). The CE-ES-MS optimization procedure includes the position of the capillary in the stainless steel interface, the flow of the sheath liquid and its composition.

Acetates↗

Humic acid capillary zone electrophoresis adsorption on capillary walls, separation in metal ion supplemented buffer and the fingerprints.

Capillary zone electrophoresis (CZE) in quartz tubes is often being used for the separation and characterization of humic acids (HA). A method was found to follow adsorption (and kinetics) of humic acids on a fused-silica capillary wall. It was shown that the adsorption of humic acids on an uncoated capillary wall is high. The effect on sorption of additives to the background electrolyte (BGE) was studied. Sorption can be eliminated by adding magnesium(II) salts (14-50 mM) to the BGE (pH 3.40) with resultant highly reproducible electropherograms as well as detailed and expressive fingerprints for HA of different origin.

Adsorption↗

Separation of oligonucleotides and DNA fragments by capillary electrophoresis in dynamically and permanently coated capillaries, using a copolymer of acrylamide and beta-D-glucopyranoside as a new low viscosity matrix with high sieving capacity.

New copolymers of acrylamide and beta-D-glucopyranoside were synthesized and characterized. The different reactivity of the two monomers towards radical polymerization meant we could control the growth of the polymer chains whose length was inversely related to the number of glucose residues incorporated in the copolymers. The properties of these polymers were investigated in the separation of oligonucleotides and double-stranded DNA by capillary electrophoresis (CE) in coated and uncoated capillaries. The new copolymers were a suitable matrix for CE due to their high-resolving capacity and low viscosity. We also looked into the advantages of a new method of dynamic suppression of electroosmotic flow based on the addition of small amounts (0.03-0.05%) of dimethylacrylamide to the sieving and to the running buffer. A complete test was run on the reproducibility and efficiency of separations carried out in a permanently and dynamically coated capillary, and the advantages and disadvantages of the two methods were compared.

Acrylic Resins↗

Capillary electrophoresis as a nanoreactor of separation capability: on-capillary reaction catalyzed by transition metal ions.

The catalytic oxidation of 1,2-dihydroxy-benzene-3,6-disulfonate (tiron) by metal ions has been studied for detection of the metal ions in capillary electrophoresis (CE). Although Co(2+) shows the strongest catalytic capability, some other metal ions also catalyze this reaction. If metal ions encounter a H(2)O(2 )zone after electrophoretic separation in the running buffer containing tiron, tiron is catalytically oxidized while the metal ion passes through the H(2)O(2) zone. Anionic tiron radicals produced by the reaction are finally measured by the detector; in this scheme, the capillary acts as a nano- or microreactor as well as a microseparator. The effective capillary length can be controlled by changing the interval between metal ion and H(2)O(2) injections. This scheme has been successfully applied to the detection of Co(2+), Cu(2+), Mn(2+), and VO(2+). The detectability is discussed from several viewpoints, such as the intrinsic catalyst ability of metal ions, the kinetics of the catalytic reaction, and reaction times determined by the mobility of the zone of the metal ion. Some strange behaviors, which cannot be predicted by batch experiments, are also reported.

Catalysis↗

Nonaqueous capillary electrophoretic separation of polyphenolic compounds in wine using coated capillaries at high pH in methanol.

Nonaqueous capillary electrophoretic separation of a group of flavonoids (quercetin, myricetin, catechin, epicatechin) and resveratrol in wine was investigated in methanol at high pH. Malonate background electrolyte (pH* 13.5, ionic strength I = 14.2 mmol/L) provided highly repeatable separations of the analytes. Tests of untreated and coated (poly(glycidylmethacrylate-co-N-vinylpyrrolidone)) capillaries showed the analysis to be faster (6.5 min vs. 25 min) and the repeatability better in the coated capillaries. The coating procedure was simple and highly repeatable and the coating was stable during 40-45 runs. Determination of the last migrating peaks (epicatechin, resveratrol and catechin) was achieved merely by evaporating the wine samples and reconstituting the residue in methanol. For determination of the first migrating peaks (quercetin and myricetin) the samples were submitted to solid-phase extraction in C8 cartridges.

Chemical Phenomena↗

Capillary zone electrophoresis of metal-binding proteins in formic acid with UV- and mass spectrometric detection using cationic transient capillary isotachophoresis for preconcentration.

A capillary zone electrophoresis (CZE) method with preceding cationic transient capillary isotachophoresis (tCITP-CZE) was developed for uncoated fused-silica capillaries to analyze metal-binding proteins (MBPs) of clinical relevance. UV detection was followed by mass spectrometry (MS). Optimization was done with model proteins of properties similar to relevant human MBPs. Using 1.0 mol x L(-1) formic acid (pH 1.78) as electrolyte resulted in up to 165000 plates m(-1) in CZE and 230000 plates m(-1) in combination with tCITP and analysis time was less than 5 min in uncoupled mode. Cationic tCITP with 125 mmol x L(-1) ammonium formate, buffered to pH 4.00, as leading electrolyte improved sample loadability considerably in comparison with sample stacking without impairing resolution. Following systematic optimization of the electrospray ionization process (ESI) the coupled system ((tCITP)-CZE-UV-ESI-MS) was tested with protein model mixtures and human MBPs. Repeatability of migration times was < 0.64% in pure CZE mode and in tCITP-CZE mode and < 0.83% in CZE-ESI-MS coupled mode. Mass accuracy was < 0.015%. Limits of detection were found to be in the range 50-160 fmol.

Calibration↗

A novel technique for on-capillary preconcentration of anionic compounds applied to the trace analysis of rapamycin in human blood by capillary electrophoresis.

A capillary electrophoretic (CE) method with UV detection at 278 nm has been developed for analysis of the immunosuppressant rapamycin (sirolimus) in human blood at low microg.L(-1) levels. Separation has been achieved in an acidic carrier electrolyte containing sodium dodecyl sulfate and 20% v/v methanol. For sample cleanup and preconcentration, both an off-line solid-phase extraction step using a silica-based reversed-phase material and a newly developed on-capillary focusing technique have been employed. The subsequent treatment of rapamycin under alkaline conditions leads to a cleavage of the lacton bond of the molecule, generating a negatively charged carboxylic group which allows electrokinetic injection into the CE instrument. During the injection process, the negatively charged analyte migrates into an acidic carrier electrolyte, so that it becomes neutral due to protonation and is focused at the capillary inlet. Injection times of 300 s at -7.5 kV could be applied without band-broadening. Results for real samples indicated that the method is fully suited for routine applications and may be an attractive alternative to established liquid chromatographic techniques.

Anions↗

Enantiomeric separation by capillary electrochromatography using monolithic capillaries with sol-gel-glued cyclodextrin-modified silica particles.

By an on-column sol-gel process, a chiral monolithic stationary phase was prepared by the fusion of permethyl-beta-cyclodextrin-silica (Chira-Dex-silica) particles and by linking them to the internal capillary wall. The resulting monolith is stable toward voltage (30 kV) and pressure (300 bar) and possesses a high efficiency (up to 100,000 theoretical plates per meter). Efficient enantiomeric separation of various chiral compounds by pressure-supported capillary electrochromatography (CEC) was achieved. When comparing this method to capillary liquid chromatography (LC) employing the same column in an unified equipment, CEC shows a twofold higher column efficiency at comparable elution times and hence better resolution factors.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary electrochromatography with monolithic stationary phases. 4. Preparation of neutral stearyl-acrylate monoliths and their evaluation in capillary electrochromatography of neutral and charged small species as well as peptides and proteins.

A neutral, nonpolar monolithic capillary column having a relatively strong electroosmotic flow (EOF) yet free of electrostatic interactions with charged solutes was developed for the reversed-phase capillary electrochromatography (RP-CEC) of neutral and charged species including peptides and proteins. The neutral nonpolar monolith is based on the in situ polymerization of pentaerythritol diacrylate monostearate (PEDAS) in a ternary porogenic solvent composed of cyclohexanol, ethylene glycol, and water. PEDAS plays the role of both the cross-linker and the ligand provider, generating a macroporous nonpolar monolith having C17 chains as the chromatographic ligands. Despite the fact that the neutral PEDAS monolith is devoid of fixed charges, the monolithic capillary columns exhibited a relatively strong EOF due to the ability of PEDAS to adsorb sufficient amounts of electrolyte ions from the mobile phase. The adsorbed ions imparted the neutral PEDAS monolith the zeta potential necessary to support the EOF required for mass transport across the monolithic column. The absence of fixed charges on the surface of the neutral PEDAS monolith and in turn the adsorption sites for electrostatic attraction of charged solutes allowed the rapid and efficient separations of proteins and peptides at pH 7.0, with an average plate number of 255,000 and 121,000 plates/m, respectively. To the best of our knowledge, this constitutes the first report on the separation of proteins at neutral pH by RP-CEC using a neutral monolithic column.

Chromatography, Micellar Electrokinetic Capillary↗

Two-dimensional separation system of coupling capillary liquid chromatography to capillary electrophoresis for analysis of Escherichia coli metabolites.

A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.

Amino Acids↗

Capillary electrophoresis determination of biogenic amines by field-amplified sample stacking and in-capillary derivatization.

A sensitive CE method for determining biogenic amines in wines based on in-capillary derivatization with 1,2-naphthoquinone-4-sulfonate is presented. In this method, reagent and buffer solutions are introduced hydrodynamically into the capillary whereas the sample is injected electrokinetically, thus, allowing a selective preconcentration of the analytes by field-amplified sample stacking. Amines are labeled inside the capillary using a zone-passing derivatization approach in mixed tandem mode. The most relevant variables influencing on the derivatization and separation as well as significant interactions have been evaluated using experimental design. Multi-criteria decision making is utilized for the simultaneous optimization of interacting variables through overall desirability response surfaces. The validation of the method has proven an excellent separation performance and accuracy for the determination of biogenic amines such as histamine, tryptamine, phenylethylamine, tyramine, agmatine, ethanolamine, serotonin, cadaverine, and putrescine in red wines. Detection limits range from 0.02 mg/L for ethanolamine to 0.91 mg/L for serotonin. The RSDs for migration time and peak area are around 1.2 and 6.2%, respectively. Red wines from different Spanish regions have been analyzed using the proposed method.

Biogenic Amines↗