Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BLOOD CIRCULATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Regional cerebral blood flow in normal blood circulated and perfluorocarbon transfused rats.

Perfluorocarbon blood substitutes have been shown to exert a protective effect in animal models of cerebral ischemia. The mechanisms by which PFCs improve cerebral hemodynamics are uncertain, however decreased viscosity, small particle size and high oxygen solubility relative to plasma are important factors. Extensive perfluorocarbon exchange transfusion (FC-43) in the rat to a hematocrit of 1%, produces a 100% increase in total cerebral blood flow (FIO2 = 1.0, CaO2 = 6 vol%). Similar increases were seen in normal blood circulated animals breathing 12% O2 (CaO2 = 12 vol%). Therefore, immediately following PFC exchange and the resulting decrease in CaO2, oxygen delivery to the brain is maintained by increasing total blood flow in a manner similar to hypoxic hypoxia.

Animals↗

Accuracy and reproducibility of the measurement of actively circulating blood volume with an integrated fiberoptic monitoring system.

OBJECTIVE: Bedside monitoring of circulating blood volume has become possible with the introduction of an integrated fiberoptic monitoring system that calculates blood volume from the changes in blood concentration of indocyanine green dye 4 mins after injection. The aim of this investigation was to compare the blood volume estimate of the integrated fiberoptic monitoring system (group 1) with the standard methods of blood volume measurement using Evans blue (group 2), and indocyanine green measured photometrically (group 3). DESIGN: Prospective laboratory study. SETTING: Animal laboratory of a University's institute for experimental surgery. SUBJECTS: Eleven anesthetized, paralyzed, and mechanically ventilated piglets. INTERVENTIONS: A central venous catheter was used for the injection of the indicator dyes (Evans blue and indocyanine green). A fiberoptic thermistor catheter was advanced into the thoracic aorta. The fiberoptic catheter detects indocyanine green by reflection densitometry for the estimation of blood volume of the integrated fiberoptic monitoring system. Samples for the determination of Evans blue and indocyanine green concentrations were drawn from an arterial catheter in the femoral artery over a period of 17 mins after injection. MEASUREMENTS AND MAIN RESULTS: Measurements were performed during normovolemia, hypovolemia (blood withdrawal of < or = 30 mL/kg), and hypervolemia (retransfusion of the withdrawn blood plus an infusion of 10% hydroxyethyl starch [45 mL/kg]). Linear regression, correlation, and bias were calculated for the comparison of the blood volume estimates by the fiberoptic monitoring system (group 1) vs. the total blood volume estimates using Evans blue (group 2) and indocyanine green (group 3): group 1 = 0.82.group 2-26 mL; r2 = 82.71%; r = .91; n = 40; group 1-group 2 +/- 1 SD = -435 +/- 368 mL; group 1 = 0.79.group 3 + 50 mL; r2 = 74.81%; r = .87; n = 28; group 1-group 3 +/- 1 SD = -506 +/- 374 mL. CONCLUSIONS: The results demonstrate that the blood volume estimate of the fiberoptic monitoring system (group 1) correlates closely with the total blood volume measurement using Evans blue (group 2) and indocyanine green (group 3). Trapped indicator in the packed red cell column after centrifugation of the blood samples may account for an overestimation of group 2 and group 3 of approximately 10% to 14%, but there still remains a proportional difference of 10% between group 1 vs. group 2 and vs. group 3. This difference is due to the longer mixing times of group 3 (16 mins) and group 2 (17 mins), during which they are distributed in slowly exchanging blood pools. It seems that the blood volume estimate of the fiberoptic monitoring system (group 1) represents the actively circulating blood volume and may be useful for bedside monitoring.

Animals↗

Infection and dysfunction of circulating blood dendritic cells and their subsets in chronic hepatitis C virus infection.

BACKGROUND: To understand interactions between dendritic cells (DCs) and viruses, in vitro-cultured monocyte-derived DCs are usually used for functional analyses. However, several recent studies indicate that circulating blood DCs are different from monocyte-derived DCs, both phenotypically and functionally. Indeed, circulating DCs act as functional antigen-presenting cells in vivo. This study was conducted to evaluate the function of circulating blood DCs in patients with chronic hepatitis C and to examine whether circulating DCs from these patients were infected by hepatitis C virus (HCV). METHODS: The phenotypes and biological functions of circulating DCs from patients with chronic hepatitis C ( n = 27), patients with non-HCV chronic liver disease ( n = 7), and normal volunteers ( n = 13) were analyzed. The presence of the HCV genome sequence in circulating blood DCs and in subsets of circulating DCs (myeloid DCs and plasmacytoid DCs) in patients with chronic hepatitis C was assessed. RESULTS: The stimulatory capacity of circulating DCs was significantly reduced in patients with chronic hepatitis C compared to patients with non-HCV chronic liver diseases and normal controls ( P < 0.01). HCV RNA was identified in the overall population of circulating DCs, and in myeloid DCs and plasmacytoid DCs. Nucleotide sequences of the 5' non-coding region of HCV RNA showed marked differences between paired samples of circulating DCs and sera from the same patients. CONCLUSIONS: Our results indicate the dysfunction and infection of circulatory blood DCs in chronic HCV infection. This may compromise the capacity of patients with hepatitis C to induce an effective antiviral immune response.

Adolescent↗

Enhanced localization of liposomes with prolonged blood circulation time in infected lung tissue.

In an experimental model of unilateral pneumonia caused by Klebsiella pneumoniae in rats we investigated whether intravenous administration of liposomes with prolonged blood circulation time resulted in significant localization of liposomes in infected lung tissue. Liposomes (100 nm) composed of hydrogenated phosphatidylinositol:hydrogenated phosphatidylcholine:cholesterol (molar ratio, 1:10:5) radiolabeled with gallium-67-deferoxamine showed relatively long blood circulation time. The degree of localization of these long circulating liposomes in the infected left lung was significantly higher compared to that of localization of 110 nm egg phosphatidylglycerol:egg phosphatidylcholine:cholesterol (molar ratio, 1:10:5) liposomes which exhibited relatively short blood circulation time. At 16 h after administration of the long circulating liposomes (when 10% of the injected dose was still present in the bloodstream) localization of liposomes in the infected left lung was increased up to 10-fold compared to the left lung of uninfected rats, and appeared to be highly correlated with the intensity of the infection. In the uninfected right lung the localization of long circulating liposomes was not increased. The degree of localization of liposomes in the infected tissue is dependent on the residence time of liposomes in the blood compartment. The extent of localization of long circulating liposomes in infected tissue appeared to be dependent on the liposomal dose administered.

Animals↗

Accuracy of carboxyhemoglobin dilution method for the measurement of circulating blood volume.

PURPOSE: The management of circulating blood volume (BVc) is crucial in intensive care unit (ICU) patients. The purpose of this study was to verify the accuracy and precision of the carbon monoxide-labeled hemoglobin (CO-Hb) dilution method (CO method) by comparing it with the 51Cr-labeled erythrocyte dilution method (51Cr method) for the measurement of BVc. METHODS: A prospective study was performed in 18 patients who underwent coronary artery bypass grafting (CABG) under mild hypothermic cardiopulmonary bypass (CPB). The BVc was measured by both the CO method and the 51Cr method at 24 hr after ICU admission in order to verify the accuracy and precision of the CO method. Paired data were assessed in absolute terms, and percentage errors were calculated by the degree of agreement. RESULTS: Small mean differences and standard deviations between the CO method and the 51Cr method (-70.2 +/-184.8 mL) and small percentage errors (-0.49+/-1.29%) indicated the accuracy and precision of the CO method, and a close correlation was observed (r = 0.97). CONCLUSION: The CO method can measure BVc with a similar degree of accuracy as the 51Cr method. It is simple, repeatable and safe without the risk of exposure to radioactivity in the ICU.

Blood Volume↗