Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “spatial localization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Joint spatial-directional localization features of wave fields focused at a complex point.

A systematic study of the joint spatial-directional localization features of monochromatic wave fields focused at a complex point is presented, on the basis of recently introduced measures of spatial and directional spread for wide-angle wave fields. Such features are compared with those of a class of fields defined to achieve the theoretical minimum product of these spread measures. It is found that the two classes of fields are remarkably similar.

Journal Article↗

Sagittal curvature of total knee replacements predicts in vivo kinematics.

BACKGROUND: It is known that in vivo kinematics after total knee replacement is influenced by the design of the implant. The goal of this study was to show that the sagittal curvature of two different knee prostheses differing in geometric design predicts their in vivo motion behavior. METHODS: Three-dimensional tibio-femoral displacements of two prosthesis designs (single radius vs. dual radius) were measured during knee extension under weight bearing conditions by in vivo video fluoroscopy. Finite helical axes were computed to represent the tibio-femoral motions. Angular deviation alpha and the spatial localization deviation delta were used to characterize the motions. Angular deviation is the angle between each incremental finite helical axis and the medio-lateral axis of the femoral component of the prosthesis. The spatial localization deviation is the distance between each finite helical axis and the center of the femoral component of the prosthesis. Statistical comparisons were performed using the median and the interquartile range of the angular deviation and the spatial localization deviation. FINDINGS: The single-radius design showed finite helical axes concentrated at a single axis near to the medio-lateral axis of the femoral component. The angular and spatial localization deviation of the dual radius design were larger compared to the single radius design, exhibiting finite helical axes varying between two axes. INTERPRETATION: Video fluoroscopy in combination with finite helical axis analysis proved to be suitable methods to evaluate the in vivo kinematical behavior of total knee arthroplasty, which can be useful for implant designers. Knowledge of in vivo kinematics can also provide surgeons with more background information about the total knee arthroplasty models they implant.

Arthroplasty, Replacement, Knee↗

Spatiotemporal analysis of epizootic raccoon rabies propagation in Connecticut, 1991-1995.

The quantitative analysis of pathogen transmission within its specific spatial context should improve our ability to predict and control the epizootic spread of that disease. We compared two methods for calibrating the effect of local, spatially distributed environmental heterogeneities on disease spread. Using the time-of-first-appearance of raccoon rabies across the 169 townships in Connecticut, we estimated local spatial variation in township-to-township transmission rate using Trend Surface Analysis (TSA) and then compared these estimates with those based on an earlier probabilistic simulation using the same data. Both the probabilistic simulation and the TSA reveal significant reduction in transmission when local spatial domains are separated by rivers. The probabilistic simulation suggested that township-to-township transmission was reduced sevenfold for townships separated by a river. The global effect of this sevenfold reduction is to increase the time-to-first-appearance in the eastern townships of Connecticut by approximately 29.7% (spread was from west to east). TSA revealed a similar effect of rivers with an overall reduction in rate of local propagation due to rivers of approximately 22%. The 7.7% difference in these two estimates reveals slightly different aspects of the spatial dynamics of this epizootic. Together, these two methods can be used to construct an overall picture of the combined effects of local spatial variation in township-to-township transmission on patterns of local rate of propagation at scales larger than the immediate nearest neighboring townships.

Animals↗

Implications for bcd mRNA localization from spatial distribution of exu protein in Drosophila oogenesis.

Subcellular RNA localization in different cell types leads to asymmetric distribution of proteins in these cells. The localization of bicoid (bcd) messenger RNA to the anterior pole of the developing Drosophila oocyte gives rise in embryogenesis to a steep concentration gradient of the bcd protein, a transcription factor that activates expression of zygotic genes needed for anterior development. The exuperantia (exu) gene is necessary for this localization of bcd mRNA. Here we express a chimaeric gene encoding a fusion between the Acquorea victoria green fluorescent protein (GFP) and the exu protein (Exu) in female germ cells, and find that the fusion protein fluoresces strongly in both live and fixed cells during Drosophila oogenesis. The fusion protein rescues an exu null allele, restoring full fertility to females, and is expressed and localized in a temporal and spatial pattern similar to native Exu. The high sensitivity of the GFP tag provides important new details on the subcellular localization of Exu. The fusion protein is found in particles concentrated at ring canals, where transport occurs between nurse cells and the oocyte. Drugs such as colchicine and taxol that affect microtubule stability alter localization of the particles. We propose that the particles are ribonucleoprotein complexes or vesicles which transport bcd mRNA along microtubules and target it to the anterior oocyte cortex.

Animals↗

Temporal and spatial regulation of fibronectin in early Xenopus development.

Pattern formation and temporal control of gene expression in Xenopus development were investigated using fibronectin as a biochemical marker. We determined the spatial localization of fibronectin in the embryo by immunofluorescence and the temporal program of its expression by biosynthesis studies and Western blotting techniques. At the start of gastrulation, fibronectin is localized on the roof of the blastocoel which serves as the surface upon which mesodermal cells will migrate. However, since we find fibronectin secreted by all parts of the embryo, localization is probably achieved through spatially localized receptors that bind secreted fibronectin. Fibronectin levels and fibronectin synthesis rates increase following the midblastula stage. This increase is independent of transcription and therefore involves activation of maternal RNA for fibronectin. Since this message mobilization also occurs in activated but unfertilized eggs, this event must be regulated separately from the midblastula transition.

Animals↗

Phosphoinositide lipids as signaling molecules: common themes for signal transduction, cytoskeletal regulation, and membrane trafficking.

Signaling roles for phosphoinositides that involve their regulated hydrolysis to generate second messengers have been well characterized. Recent work has revealed additional signaling roles for phosphoinositides that do not involve their hydrolysis. PtdIns 3-P, PtdIns 3,4,5-P3, and PtdIns 4,5-P2 function as site-specific signals on membranes that recruit and/or activate proteins for the assembly of spatially localized functional complexes. A large number of phosphoinositide-binding proteins have been identified as the potential effectors for phosphoinositide signals. Common themes of localized signal generation and the spatially localized recruitment of effector proteins appear to underlie mechanisms employed in signal transduction, cytoskeletal, and membrane trafficking events.

Animals↗

Model-based maximum-likelihood estimation for phase- and frequency-encoded magnetic-resonance-imaging data.

A maximum-likelihood (ML)-based magnetic-resonance-imaging (MRI) reconstruction algorithm is established, based on frequency- and phase-encoded data. The model on which the ML method is based is a superposition of exponentially decaying, sinc-modulated sinusoids, arising from the basic Bloch equations for MR spectroscopy, modified to account for the distribution of resonance frequencies and phases used for spatial localization in the image field. Spatial-localizing gradients are assumed to be known linear functions of spatial coordinate position, with the x-encode (frequency) gradient applied continuously during the full duration of data collection, and the y-encode (phase) gradient applied during varying time periods before data collection. A single-voxel emitter becomes sinc-modulated in the x, y directions at rates proportional to voxel size and gradient strengths in the x-encode and y-encode directions. The full two-dimensional MRI signal becomes a superposition of sinc-modulated, exponentially decaying, single-sinusoid emitters, one for each voxel. The ML estimation of spin-density and spin-spin relaxation decay time images becomes a nonlinear least-squares optimization problem; it is solved using an iterative expectation-maximization algorithm for estimating multiple modulated sinusoids in noise. Phantom studies are presented, demonstrating the accuracy of the model and the application of the algorithm to spin-density and spin-spin relaxation decay time profiles.

Algorithms↗

[Discrimination difficulties--expression of disordered relative localization?].

Spatial uncertainty was examined according to a procedure suggested by Bedell and Flom (1981) ("triangle procedure") and additionally with a line-division test designed by Kundt. A horizontal line of a length of about 20 degrees and a shorter one of 4.3 degrees was divided into two equal parts. Strabismic amblyopes mark the middle of such a line with less precision and greater uncertainty than visually normal subjects do. Visual acuity was measured by single optotypes (Landolt rings), as well as by line optotypes with spaces of 2.6 min of arc between each other (C-test). Surprisingly, there was little correlation between visual acuity--even line acuity--and localization tasks.

Amblyopia↗

Egocentric localization changes following unilateral strabismus surgery.

We measured spatial localization (using an open-loop pointing task) monocularly in each eye of eight patients undergoing unilateral strabismus surgery. Most of these patients had some degree of binocular vision. We found that, in most cases, changes in spatial localization produced by surgery on the operated eye paralleled those found in the other eye, both in magnitude and duration. Unilateral surgery can have central effects on egocentric localization.

Adolescent↗

Horizontal line bisections in upper and lower body space.

Whereas the ventral cortical visual stream is important in object recognition, the dorsal stream is specialized for spatial localization. In humans there are also right and left hemisphere asymmetries in visual processing: the left hemisphere being more important in object recognition and the right in specifying spatial locations. Based on these dorsal-ventral and right-left where-what dichotomies, one would expect that the dorsal right hemisphere systems would be most activated during spatial localization tasks, and this activation may induce a leftward spatial bias in lower space. To determine if visual stimuli in upper and lower body space evoke different hemispheric activation, we had 12 normal participants bisect horizontal lines above and below eye level. Participants erred leftward in lower body space relative to upper body space (M = 1.3345 mm and 0.4225 mm, respectively; p = .011). In upper body space, bisection errors did not differ from zero, but in lower body space, errors tended to deviate leftward (M = 1.3345 mm, differs from null hypotheses at p = .0755). Our results are consistent with dorsal stream/right hemisphere activation when performing a spatial localization task in lower versus upper body space.

Adult↗

Electron paramagnetic resonance imaging of the rat heart.

It has been hypothesized that free radical metabolism, oxygenation and nitric oxide generation in biological organs such as the heart may vary over the spatially defined tissue structure. To address fundamental questions regarding the role of spatially localized alterations in radical metabolism, oxygenation and nitric oxide in the pathophysiology of cellular injury during ischaemia, we have developed instrumentation optimized for 3D spatial and 3D or 4D spectral-spatial imaging of free radicals in the isolated perfused rat heart at 1.2 GHz. Using this instrumentation, high-quality 3D spectral-spatial imaging of nitroxide metabolism was performed as well as spatially localized measurements of oxygen concentrations, based on the oxygen-dependent linewidth broadening observed. In these spectral-spatial images, submillimetre resolution was observed enabling visualization of the left ventricular and right ventricular myocardium. With 3D spatial imaging using single-line labels, resolutions down to 100 to 200 microm were obtained enabling visualization of the ventricles, aortic root and proximal coronary arteries. Using metal complexes which trap nitric oxide, measurement and imaging of nitric oxide generation during ischaemia was performed. With the use of 15N isotope labelling it was possible to map the metabolic pathway of this nitric oxide generation. Thus, EPR imaging is a powerful tool which can provide unique information regarding the spatial localization of free radicals, oxygen and nitric oxide in biological organs and tissues.

Animals↗

PTV margin determination in conformal SRT of intracranial lesions.

The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT-MRI image fusion spatial localization, and Gill-Thomas-Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations.

Brain Neoplasms↗

Auditory localization for spatial orientation.

The use of three-dimensional auditory technology that provides localization of auditory cues presented through headphones is proposed as a means of providing supplemental information to pilots on the spatial orientation of an aircraft. This technique shows promise for reducing accidents due to spatial disorientation associated with high visual load. A study was conducted using United States Air Force pilots as subjects to determine desirable¿ cue characteristics for accurately localizing auditory cues using this technique. The study examined the use of 9 different cue types at each of 2 frequency levels. It was found that the accuracy of subjects' localization of cues in elevation was greatly enhanced by the use of multidimensional cues that provided redundant elevation information through varying frequencies and distance from the horizon cues in addition to the inherent spatial location information. Trade-offs in azimuth localization accuracy and response time were noted, however. Recommendations are made for further developing and investigating this technique for the aircraft spatial orientation task.

Accidents, Aviation↗

Band-selective spin echoes for in vivo localized 1H NMR spectroscopy.

This study describes a new single spin-echo spatial localization sequence, BASSALE or BAnd-Selective Spin echo Acquisition for Localized Editing, that overcomes a number of the limitations of the STEAM and PRESS volume selection pulse sequences. It achieves conformal volume localization in a single shot by spatially tailored suppression of all magnetization outside a 2D region of interest followed by selection of a single orthogonal slice. This separation of spatial localization from the echo formation process has permitted use of a spectrally selective cosine-modulated sinc refocusing pulse to acquire localized 1H spectra with the water suppression efficiency of STEAM and the sensitivity of PRESS. Echoes formed by such spectrally selective pulses have been termed band-selective spin echoes. The BASSALE sequence attains shorter echo times than PRESS, inhibits scalar spin-spin interactions to permit localized editing and T2 relaxometry of metabolites with J-coupled spins (e.g., lactate), is insensitive to homonuclear multiple-quantum and polarization transfer effects, and can be made sensitive or insensitive to spin displacement effects. Applications are shown both with phantoms and in situ in the rat brain.

Amino Acids↗

Williams syndrome and deficiency in visuospatial recognition.

This study aimed to assess the visuospatial abilities of five children with Williams syndrome (four males aged 9 years 3 months, 7 years 11 months, 8 years 1 month, and 10 years 8 months respectively, and one female aged 6 years 3 months). First, the children's visuospatial abilities were examined by asking them to copy a figure. Second, their cognitive processing abilities were assessed using the Japanese Kaufman Assessment Battery for Children. This test was used because it is an objective one, standardized in Japan, and is a measure of fluid ability including spatial localization. Participants scored significantly low on the spatial memory subtest indicating that there was a deficit in spatial localization. Children's performance in line copying tasks improved when the dots were in colour. Results suggest a deficit in the dorsal stream of visual cognition, with a relatively preserved ventral stream.

Child↗

Topological disorder in peripheral vision.

One of the most striking properties of the mammalian visual system is that it is only the central part of the visual field, the fovea, where vision is most acute. The superiority of the fovea is particularly evident in tasks requiring accurate spatial localization. It is currently thought that peripheral spatial uncertainty is a simple consequence of the decreased sampling grain of the peripheral field. We show that the topological fidelity of the afferent projection declines with eccentricity away from the fovea and that it is this rather than the sampling grain that underlies the poorer performance of the periphery in tasks involving spatial localization. The combination of normal sampling and a disordered topology results in the periphery having good sensitivity for detection but poor sensitivity for object recognition.

Fovea Centralis↗

Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A multidimensional dose comparison tool that simultaneously examines the dose-difference and distance-to-agreement was used to evaluate the gel in both low-and high-dose gradient regions. When 3% and 3 mm criteria were used for the comparisons, more than 90% of the TLD measurements agreed with the gel, with the worst of 309 TLD chip measurements disagreeing by 40% of the criteria. All four MRI measurement session gel-measured dose distributions were compared to evaluate the time behavior of the gel. The low-dose regions were evaluated by comparison with TLD measurements at selected points, while high-dose regions were evaluated by directly comparing measured dose distributions. Tests using the multidimensional comparison tool showed detectable degradation beyond one week postirradiation, but all low-dose measurements passed relative to the test criteria and the dose distributions showed few regions that failed.

Biophysical Phenomena↗

Colour constancy in context: roles for local adaptation and levels of reference.

By determining the locations of boundaries between colour categories, we measured changes in the colour appearance of test-reflectances as a function of the simulated illumination. Test-reflectances were displayed against a variegated background of reflectance samples. Under prolonged adaptation to each illuminant, observers demonstrated a high degree of appearance-based colour constancy. By using backgrounds that consisted of chromatically biased sets of reflectances, we tested whether this stability depends on estimates of the illuminant's cone-coordinates based on simple scene statistics. The chromatic bias of the background had only a small effect on the classification of test materials. To compare the roles of spatially local and spatially extended estimation processes, we then (unknown to the observer) simulated different illuminants on the test and on the background. Observers continued to demonstrate reasonable colour constancy. To examine the relative roles of automatic adaptation and perceptual strategies, we reduced the duration of exposure to the test compared to exposure to the background (under the conflicting illuminant). The results suggest that mechanisms that preserve information across successive test-presentations (e.g. spatially local adaptation with a time course of a few seconds, and perceptual adjustments to levels of reference) are key determinants of the stability of colour appearance.

Adaptation, Ocular↗