Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VOC”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Sorption and biodegradation of vapor-phase organic compounds with wastewater sludge and food waste compost.

To test the possible use of composted food waste and wastewater sludge as biofilters to treat gas-phase volatile organic compounds (VOCs), batch experiments were conducted with an isolated strain that could degrade aromatic compounds under aerobic conditions. A benzene and trichloroethylene (TCE) mixture was used as the gas-phase pollutant in experiments with composted food waste, sludge, and soil. Under aerobic conditions, benzene was degraded as a primary substrate and TCE was degraded cometabolically, with water contents varying from 6 to 60% (volume of water added/volume of solid). Optimal water content for VOC removal was 12% for the soil, 36% for the composted food waste, and 48% for the sludge. The extent of VOC sorption and biodegradation at the optimal water content was different for each material. With the same initial VOC concentration, more VOCs were removed by sorption onto the composted food waste and the sludge, while less VOCs were biodegraded in comparison with the results using soil. The reason the biodegradation in the soil was greater may be partly attributed to the fact that, due to less sorption, the aqueous-phase concentration of VOCs, which microorganisms could utilize as a carbon source or cometabolize, was higher. We also speculate that the distribution of microorganisms in each medium affects the rate of biodegradation. A large number of microorganisms were attached to the composted food waste and sludge. Mass transfer of VOCs and oxygen to these microorganisms, which appear to have been heterogeneously distributed in clusters, may have been limited, resulting in hindered biodegradation.

Adsorption↗

Multiple microbial activities for volatile organic compounds reduction by biofiltration.

In the northeast of Italy, high volatile organic carbon (VOC) emissions originate from small-medium companies producing furniture. In these conditions it is difficult to propose a single, efficient, and economic system to reduce pollution. Among the various choices, the biofiltration method could be a good solution, because microbial populations possess multiple VOC degradation potentials used to oxidize these compounds to CO2. Starting from the air emissions of a typical industrial wood-painting plant, a series of experiments studied in vitro microbial degradation of each individual VOC. Isolated strains were then added to a laboratory-scale biofiltration apparatus filled with an organic matrix, and the different VOC behavior demonstrated the potential of single and/or synergic microbial removal actions. When a single substrate was fed, the removal efficiency of a Pseudomonas aeruginosa inoculated reactor was 1.1, 1.17, and 0.33 g m(-3) hr(-1), respectively, for xylene, toluene, and ethoxy propyl acetate. A VOC mixture composed of butyl acetate, ethyl acetate, diacetin alcohol, ethoxy propanol acetate, methyl ethyl ketone, methyl isobutyl ketone, toluene, and xylene was then fed into a 2-m(3) reactor treating 100 m3 hr(-1) of contaminated air. The reactor was filled with the same mixture of organic matrix, enriched with all of the isolated strains together. During reactor study, different VOC loading rates were used, and the behavior was evaluated continuously. After a short acclimation period, the removal efficiency was > 65% at VOC load of 150-200 g m(-3) hr(-1). Quantification of removal efficiencies and VOC speciation confirmed the relationship among removal efficiencies, compound biodegradability, and the dynamic transport of each mixture component within the organic matrix. Samples of the fixed bed were withdrawn at different intervals and the heterogeneous microbial community evaluated for both total and differential compound counts.

Air Pollutants↗

Production of blank water for the analysis of volatile organic compounds in human blood at the low parts-per-trillion level.

Blank water with low levels of volatile organic compounds (VOCs) is of critical importance in many analytical procedures. Because of the increased use of more sophisticated instrumentation, the detection limits for these compounds have dropped dramatically. Consequently, techniques in use in the analytical laboratory to generate blank water may now prove inadequate. The need for blank water with low levels of VOCs was recently underscored by the development of an analytical procedure to analyze 32 VOCs in whole blood; this procedure has detection limits in the tens of parts-per-trillion level for most VOCs. Common sources of blank water in the laboratory such as deionized, cartridge-filtered, and HPLC-grade bottled water are analyzed. These sources contained high concentrations of some VOCs that would interfere with low parts-per-trillion analyses. Well water and bottled water used for human consumption are analyzed, but both prove inadequate for the analysis of VOCs at parts-per-trillion levels. A combination of distillation and purging with helium produced blank water with VOC levels of less than 10 parts-per-trillion for most of the 16 VOCs studied.

Blood Chemical Analysis↗

Treatment of vacutainers for use in the analysis of volatile organic compounds in human blood at the low parts-per-trillion level.

Vacutainers that are routinely used for blood collection contain significant amounts of volatile organic compounds (VOCs). These VOCs interfere with the low parts-per-trillion analysis of VOCs in whole blood either by causing false positives or by masking the presence of VOCs because of high background levels. Benzene, bromoform, ethylbenzene, m/p-xylene, o-xylene, styrene, and various hydrocarbons are the most significant sources of VOC contamination present in the vacutainers. A method of removing VOCs from 10-mL gray-top vacutainers is presented. This method uses a combination of heat and vacuum to reduce the VOCs to levels compatible with low parts-per-trillion analysis of VOCs in whole blood.

Blood Specimen Collection↗

Practical approaches to plant volatile analysis.

Plants emit volatile organic compounds (VOCs) that play important roles in their interaction with the environment and have a major impact on atmospheric chemistry. The development of static and dynamic techniques for headspace collection of volatiles in combination with gas chromatography-mass spectrometry analysis has significantly improved our understanding of the biosynthesis and ecology of plant VOCs. Advances in automated analysis of VOCs have allowed the monitoring of fast changes in VOC emissions and facilitated in vivo studies of VOC biosynthesis. This review presents an overview of methods for the analysis of plant VOCs, including their advantages and disadvantages, with a focus on the latest technical developments. It provides guidance on how to select appropriate instrumentation and protocols for biochemical, physiological and ecologically relevant applications. These include headspace analyses of plant VOCs emitted by the whole organism, organs or enzymes as well as advanced on-line analysis methods for simultaneous measurements of VOC emissions with other physiological parameters.

Gas Chromatography-Mass Spectrometry↗

Comparison of predicted and derived measures of volatile organic compounds inside four new relocatable classrooms.

UNLABELLED: Our objective was to develop a process for selecting interior finish materials having low impacts with respect to emissions of toxic and odorous volatile organic compounds (VOCs) for school relocatable classrooms (RCs). A laboratory study identified alternate materials with low VOC emissions. Two pairs of RCs then were constructed. One RC per pair contained standard interior materials; the other incorporated alternate materials. The pairs were sited side-by-side at two California elementary schools in fall 2001. Fifteen target VOCs, including the toxicants formaldehyde, acetaldehyde, vinyl acetate, phenol, toluene, and naphthalene, were measured during school hours over 8 weeks in the succeeding fall cooling season. Indoor minus outdoor VOC concentrations with an advanced HVAC operated were low; only formaldehyde concentrations exceeded 5 p.p.b. Classroom VOC concentrations were predicted based on emission factors (microg/m(2)/h), material quantities and design ventilation rates. These were compared to average adjusted concentrations measured when the occupied classrooms were operating at near the code-minimum ventilation rate. For 16 of the possible 42 comparisons, measured concentrations agreed within a factor of two of predicted the predicted values. Concentrations of six of 10 VOCs were significantly lower in modified RCs though average differences were mostly less than 1 p.p.b. PRACTICAL IMPLICATIONS: Laboratory-based material testing combined with modeling and field validation to select low VOC-impact interior finish materials helped achieve the aim of providing generally acceptable air quality in new school relocatable classrooms (RCs). The accuracy of the combined process was evidenced by the correct prediction of air quality impacts, though small, due to material VOC emissions when the study RCs were ventilated at code-minimum requirements. The process could be generalized to other manufacturers and classroom types. Material selection also is important to accommodate reduced ventilation rate conditions, which likely occur in many classrooms.

Air Pollution, Indoor↗

Exhaled volatile organic compounds in patients with non-small cell lung cancer: cross sectional and nested short-term follow-up study.

BACKGROUND: Non-invasive diagnostic strategies aimed at identifying biomarkers of lung cancer are of great interest for early cancer detection. The aim of this study was to set up a new method for identifying and quantifying volatile organic compounds (VOCs) in exhaled air of patients with non-small cells lung cancer (NSCLC), by comparing the levels with those obtained from healthy smokers and non-smokers, and patients with chronic obstructive pulmonary disease. The VOC collection and analyses were repeated three weeks after the NSCLC patients underwent lung surgery. METHODS: The subjects' breath was collected in a Teflon bulb that traps the last portion of single slow vital capacity. The 13 VOCs selected for this study were concentrated using a solid phase microextraction technique and subsequently analysed by means of gas cromatography/mass spectrometry. RESULTS: The levels of the selected VOCs ranged from 10(-12) M for styrene to 10(-9) M for isoprene. None of VOCs alone discriminated the study groups, and so it was not possible to identify one single chemical compound as a specific lung cancer biomarker. However, multinomial logistic regression analysis showed that VOC profile can correctly classify about 80% of cases. Only isoprene and decane levels significantly decreased after surgery. CONCLUSION: As the combination of the 13 VOCs allowed the correct classification of the cases into groups, together with conventional diagnostic approaches, VOC analysis could be used as a complementary test for the early diagnosis of lung cancer. Its possible use in the follow-up of operated patients cannot be recommended on the basis of the results of our short-term nested study.

Aged↗

Treatment of volatile organic compounds from polyurethane and epoxy manufacture by a trickle-bed air biofilter.

The objective of this study was to evaluate the performance of a trickle-bed air biofilter (TBAB) for the removal of volatile organic compound (VOC) produced during polyurethane (PU) and epoxy manufacture. The major VOCs emitted are ethyl acetate (EA) for PU and EA and xylene for epoxy production. For the treatment of VOCs emitted during PU production, the employed coal carbon appears to be efficient as a VOC concentration buffer in the biofiltration of waste gases. Based on the results of EA and total hydrocarbon (THC) removal, it was concluded that the TBAB is suitable for controlling VOC emission during PU manufacture. For the treatment of VOCs emitted during epoxy production, it was found that the performance of the TBAB is relatively poor due to the lack of VOC sources. However, this problem could be easily solved by mixing the VOCs emitted during PU and epoxy manufacture.

Journal Article↗

Personal exposure meets risk assessment: a comparison of measured and modeled exposures and risks in an urban community.

Human exposure research has consistently shown that, for most volatile organic compounds (VOCs), personal exposures are vastly different from outdoor air concentrations. Therefore, risk estimates based on ambient measurements may over- or underestimate risk, leading to ineffective or inefficient management strategies. In the present study we examine the extent of exposure misclassification and its impact on risk for exposure estimated by the U.S. Environmental Protection Agency (U.S. EPA) Assessment System for Population Exposure Nationwide (ASPEN) model relative to monitoring results from a community-based exposure assessment conducted in Baltimore, Maryland (USA). This study is the first direct comparison of the ASPEN model (as used by the U.S. EPA for the Cumulative Exposure Project and subsequently the National-Scale Air Toxics Assessment) and human exposure data to estimate health risks. A random sampling strategy was used to recruit 33 nonsmoking adult community residents. Passive air sampling badges were used to assess 3-day time-weighted-average personal exposure as well as outdoor and indoor residential concentrations of VOCs for each study participant. In general, personal exposures were greater than indoor VOC concentrations, which were greater than outdoor VOC concentrations. Public health risks due to actual personal exposures were estimated. In comparing measured personal exposures and indoor and outdoor VOC concentrations with ASPEN model estimates for ambient concentrations, our data suggest that ASPEN was reasonably accurate as a surrogate for personal exposures (measured exposures of community residents) for VOCs emitted primarily from mobile sources or VOCs that occur as global "background" source pollutant with no indoor source contributions. Otherwise, the ASPEN model estimates were generally lower than measured personal exposures and the estimated health risks. ASPEN's lower exposures resulted in proportional underestimation of cumulative cancer risk when pollutant exposures were combined to estimate cumulative risk. Median cumulative lifetime cancer risk based on personal exposures was 3-fold greater than estimates based on ASPEN-modeled concentrations. These findings demonstrate the significance of indoor exposure sources and the importance of indoor and/or personal monitoring for accurate assessment of risk. Environmental health policies may not be sufficient in reducing exposures and risks if they are based solely on modeled ambient VOC concentrations. Results from our study underscore the need for a coordinated multimedia approach to exposure assessment for setting public health policy.

Adult↗

Odor and volatile organic compound removal from wastewater treatment plant headworks ventilation air using a biofilter.

Laboratory-scale experiments and field studies were performed to evaluate the feasibility of biofilters for sequential removal of hydrogen sulfide and volatile organic compounds (VOCs) from wastewater treatment plant waste air. The biofilter was designed for spatially separated removal of pollutants to mitigate the effects of acid production resulting from hydrogen sulfide oxidation. The inlet section of the upflow units was designated for hydrogen sulfide removal and the second section was designated for VOC removal. Complete removal of hydrogen sulfide (H2S) and methyl tert-butyl ether (MTBE) was accomplished at loading rates of 8.3 g H2S/(m3 x h) (15-second empty bed retention time [EBRT]) and 33 g MTBE/(m3 x h) (60-second EBRT), respectively. In field studies performed at the Hyperion Treatment Plant in Los Angeles, California, excellent removal of hydrogen sulfide, moderate removal of nonchlorinated VOCs such as toluene and benzene, and poor removal of chlorinated VOCs were observed in treating the headworks waste air. During spiking experiments on the headworks waste air, the percentage removals were similar to the unspiked removals when nonchlorinated VOCs were spiked; however, feeding high concentrations of chlorinated VOCs reduced the removal percentages for all VOCs. Thus, biofilters offer a distinct advantage over chemical scrubbers currently used at publicly owned treatment works in that they not only remove odor and hydrogen sulfide efficiently at low cost, but also reduce overall toxicity by partially removing VOCs and avoiding the use of hazardous chemicals.

Air Pollutants↗

Exposure to emissions from gasoline within automobile cabins.

Gasoline is emitted from automobiles as uncombusted fuel and via evaporation. Volatile organic compounds (VOC) from gasoline are at higher levels in roadway air than in the surrounding ambient atmosphere and penetrate into automobile cabins, thereby exposing commuters to higher levels than they would experience in other microenvironments. Measurements of VOC concentrations and carbon monoxide were made within automobiles during idling, while driving on a suburban route in New Jersey, and on a commute to New York City. Concentrations of VOC from gasoline were determined to be elevated above the ambient background levels in all microenvironments while VOC without a gasoline source were not. The variability of VOC concentrations with location within the automobile was determined to be smaller than inter-day variability during idling studies. VOC and carbon monoxide levels within the automobile cabin differed among the different routes examined. The levels were related to traffic density and were inversely related to driving speed and wind speed. Overall, daily VOC exposure for gasoline-derived compounds during winter commuting in New Jersey was estimated to range between 5 and 20% and constituted between 15 and 40% of an individual's daily exposure based on comparison to urban and suburban settings, respectively. VOC exposure during commuting in Southern California was estimated to range between 15 and 60%.

Air↗

Volatile organic compounds and building bake-out.

VOCs are generally present in indoor air at concentrations greater than, and not infrequently much greater than, those of outdoor air. These VOCs cover a broad spectrum of compounds, ranging from about 20 to several hundred in any given sample of indoor air. However, the concentrations observed in nonindustrial indoor air samples are generally much lower than occupational health standards. Still, the sources of VOCs indoors are varied and ubiquitous, and the health effects of exposure to VOC are varied and range from irritant effects associated with SBS, to carcinogenic and reproductive effects. A recent study of the health effects of exposure to low concentrations of VOCs has produced surprising results and insight into some of the more subtle health effects. However, additional study is needed to confirm these effects. Many general techniques for mitigating exposures to VOCs are available; the difficulty lies in obtaining the specific information necessary to apply these techniques effectively to a given problem. In some cases this information relates to diagnostics, either to the cause of particular symptoms in individuals or about the particular source or sources of VOCs. In other cases, this information is related to the application and efficacy of a particular mitigation technique for a particular problem. Bake-out is a promising technique for reducing exposures to VOCs in new office buildings. However, further effort in delineating its utility is necessary before it can be recommended.

Air Pollutants, Occupational↗

A mechanistic algorithm for predicting blood:air partition coefficients of organic chemicals with the consideration of reversible binding in hemoglobin.

The objectives of the present study were (i) to develop a mechanistic algorithm for predicting blood:air partition coefficients (PCs) of volatile organic chemicals (VOCs), and (ii) to apply this algorithm to predict the rat blood:air PCs of several VOCs. The approach consisted initially of developing an algorithm to predict the blood:air PCs of VOCs solely based on the solubility phenomenon and then of extending the algorithm to include protein binding. The algorithm based on solubility phenomenon predicted blood:air PCs by dividing the estimated solubility of chemicals in blood by their saturable vapor concentrations at 37 degrees C. The rat blood:air PCs predicted using this algorithm were in close agreement with the experimental values for relatively hydrophilic VOCs such as ketones, alcohols, acetate esters, and diethyl ether (with an average ratio of 0.80 between predicted and experimental values), whereas there was a marked discrepancy in the case of relatively lipophilic VOCs such as alkanes, haloalkanes, and aromatic hydrocarbons (with an average ratio of 0.21 between predicted and experimental values). This discrepancy was hypothesized to be due to the occurrence of reversible binding of these substances in rat hemoglobin based on literature evidence of the existence of hydrophobic holes (or "xenon-binding" pockets). The association constants (Ka) for the presumed reversible hemoglobin binding of several alkanes, haloalkanes, and aromatic hydrocarbons were estimated from the difference between chemical concentration in rat erythrocytes predicted by the solubility-based algorithm and that deduced from the previously published experimental blood:air PCs for these chemicals (which presumably included contribution of hemoglobin binding in addition to "true" solubility). The Ka values estimated in this manner ranged from 504 to 4725 M-1 for the chemicals investigated in the present study. The a priori predictions of the percentage of several VOCs (diethyl ether, methyl isobutyl ketone, n-hexane, toluene, and chloroform) in rat erythrocytes obtained with the algorithm using these Ka estimates corresponded well with previously published experimental data. The mechanistic algorithm developed in the present study should be useful for predicting the "apparent" blood:air PCs of VOCs regardless of exposure concentrations, by accounting for the relative contributions of both the true chemical solubility and reversible hemoglobin binding.

Alcohols↗

Symptoms in relation to chemicals and dampness in newly built dwellings.

OBJECTIVES: As the airtightness of dwellings has recently increased, problems associated with indoor air pollution and dampness have become important environmental health issues. The aim of this study was to clarify whether symptoms in residents living in newly built dwellings were related to chemicals and dampness. METHODS: Symptoms of 317 residents were surveyed by standardized questionnaires, and the concentrations of formaldehyde, acetaldehyde, and 17 volatile organic compounds (VOCs) in their homes were measured. Dampness (condensation on window panes and/or walls, and mold growth) was identified by questionnaires given to the householders or their partners. RESULTS: Some VOCs (toluene, butyl acetate, ethylbenzene, alpha-pinene, p-dichlorobenzene, nonanal, and xylene) were significantly related to the symptoms, and the sum of all VOCs (all identified VOCs) was significantly related to throat and respiratory symptoms [odds ratio (OR) for eye symptoms =2.4; 95% confidence interval (CI) 1.0-5.5], although the concentrations of VOCs were relatively low. As for the dampness index, condensation on window panes and/or walls was related to all symptoms, and mold growth was related to all symptoms except skin, throat and respiratory and general symptoms. As the number of dampness signs increased, the ORs increased for the symptoms except general symptoms (OR for nose symptoms = 4.4, 95% CI 1.6-11.9). CONCLUSION: Both VOCs and dampness were significantly related to symptoms. We should take measures to reduce the concentrations of VOCs, dampness and microbial growth in dwellings.

Acetaldehyde↗

The role of indole and other shikimic acid derived maize volatiles in the attraction of two parasitic wasps.

After herbivore attack, plants release a plethora of different volatile organic compounds (VOCs), which results in odor blends that are attractive to predators and parasitoids of these herbivores. VOCs in the odor blends emitted by maize plants (Zea mays) infested by lepidopteran larvae are well characterized. They are derived from at least three different biochemical pathways, but the relative importance of each pathway for the production of VOCs that attract parasitic wasps is unknown. Here, we studied the importance of shikimic acid derived VOCs for the attraction of females of the parasitoids Cotesia marginiventris and Microplitis rufiventris. By incubating caterpillar-infested maize plants in glyphosate, an inhibitor of the 5-enolpyruvylshikimate-3-phospate (EPSP) synthase, we obtained induced odor blends with only minute amounts of shikimic acid derived VOCs. In olfactometer bioassays, the inhibited plants were as attractive to naive C. marginiventris females as control plants that released normal amounts of shikimic acid derived VOCs, whereas naive M. rufiventris females preferred inhibited plants to control plants. By adding back synthetic indole, the quantitatively most important shikimic acid derived VOC in induced maize odors, to inhibited plants, we showed that indole had no effect on the attraction of C. marginiventris and that M. rufiventris preferred blends without synthetic indole. Exposing C. marginiventris females either to odor blends of inhibited or control plants during oviposition experiences shifted their preference in subsequent olfactometer tests in favor of the experienced odor. Further learning experiments with synthetic indole showed that C. marginiventris can learn to respond to this compound, but that this does not affect its choices between natural induced blends with or without indole. We hypothesize that for naïve wasps the attractiveness of an herbivore-induced odor blend is reduced due to masking by nonattractive compounds, and that during oviposition experiences in the presence of complex odor blends, parasitoids strongly associate some compounds, whereas others are largely ignored.

Animals↗

Determining the equilibrium partitioning coefficients of volatile organic compounds at an air-water interface.

The single equilibration technique (SET) was adopted to determine the partitioning coefficients (pc) at an air-water interface for volatile organic compounds (VOCs), including ethanol, iso-propanol (IPA), iso-butanol (IBA), methyl ethyl ketone (MEK) and toluene, all extensively used in industrial processes. Standard SET procedures were established. The liquid concentrations (CL) of tested VOCs ranged from 10 to 125 mg l(-1) for alcohols and MEK, and from 0.5 to 20 mg l(-1) for toluene. The temperatures (Tw) of aqueous VOC solutions were maintained at 27, 32, 38 and 42 degrees C to determine the gaseous concentrations at equilibrium (Cg*) and pc of VOCs, using the formula pc=(Cg*/CL). Results reveal that the pc values of all tested components increase slowly with Tw given a constant CL, and that the pc of alcohols and MEK fall as CL increases at a constant Tw. In contrast, the pc of toluene is not significantly impacted by a variation in CL at a constant Tw. However, the effect of CL concentration has seldom been discussed. The heats of liquid and gaseous phase transfer (DeltaHtr) of VOC, and the highly linear regression (with squared correlation coefficients, R2, from 0.901 to 0.999) between lnCg* and Tw(-1) are also evaluated. The experimental results and the VOC mass transfer characteristics are helpful for evaluating the emission of VOC from the water surface of wastewater treatment facilities.

Air↗

Sorption study of 25 volatile organic compounds in several Mediterranean soils using headspace-gas chromatography-mass spectrometry.

A sorption study of 25 volatile organic compounds (VOCs) in different agricultural soils was carried out by using headspace-gas chromatography-mass spectrometry. The extraction of the VOCs from soil samples was carried out following the EPA method with some differences such as addition of potassium chloride and different instrumental conditions which provide higher sample throughput. In addition, a complementary study on several procedures for soil fortification with VOCs was also assayed, fortification with minimal sample handling was selected in order to minimise evaporation losses of the VOCs. The effect of clay minerals (7.0-69.7%) and organic carbon (0.2-3.5%) contents on acid and alkaline (pH 5.3-8.8) soils were evaluated. Based on the results, all compounds assayed were more sorbed in alkaline soils than acid ones; chlorobenzenes interact more strongly with agricultural soils than do alkylbenzenes. The organic carbon content affects the sorption of 25 VOCs in alkaline soils (the highest sorption was found for the most organic soil), while in acid soils VOC sorption increases as the organic carbon content decreases. The clay mineral fraction plays an important role in the sorption of VOCs in acid soil owing to pi-/n-electron interactions, this effect being more marked for chlorobenzenes.

Gas Chromatography-Mass Spectrometry↗

Volatile organic compounds in dwelling houses and stables of dairy and cattle farms in Northern Germany.

Farmers are exposed to a complex mixture of airborne substances which can represent a health hazard. Especially animal production on a farm can be a risk factor for respiratory diseases. Most studies in this context focused on bioaerosols, compounds attached to bioaerosols or on gases such as ammonia or hydrogen sulfide. Less attention was paid to volatile organic compounds (VOCs) which may also cause respiratory diseases. This pilot study presents results of measuring VOCs in the air of the dwellings and stables, as well as in the outdoor environment, of cattle farms in Northern Germany in spring and autumn. Farmers on all selected farms complained of symptoms such as asthma, rhinitis and conjunctivitis which occurred especially during work in the stable but also in the dwellings. The mean concentration of total VOC (TVOC) for the outdoor environment, the dwellings, and the stables were 100 microg m(-3), 763 microg m(-3), 322 microg m(-3) in spring and 143 microg m(-3), 544 microg m(-3), 595 microg m(-3) in autumn, respectively. There was no significant difference in season. TVOC concentrations in dwellings on farms were elevated when compared to dwellings in other environments, probably because of an additional exposure to fuels and chemicals used in agriculture. Aliphatic and alicyclic hydrocarbons, aromatic compounds, and terpenes were main compounds of the dwellings and ketones, alcohols, and esters of the stables. Terpene concentrations in the stables were low probably because straw, which was not a strong terpene emitter, was used instead of sawdust as floor covering. Large amounts of methylethylketone were encountered in the air of one stable, probably from animal exhalation caused by increased animal activity. However, it was unlikely that this caused respiratory symptoms. Generally it was likely that the concentrations of VOCs were too low to have health effects on their own. On the other hand, the VOC concentrations were in a multifactor concentration range in which health effects could occur depending on the interaction with other exposure factors. Fungal spores and bacteria were observed in addition to VOCs at the examined locations. Therefore it is possible that the observed VOCs played a role in exacerbating respiratory symptoms in this multifactor exposure.

Aerosols↗