Transcutaneous CO2/O2 and CO2/air suction in patients undergoing cataract surgery with retrobulbar anaesthesia.

We investigated transcutaneous partial CO2 and O2 pressures and respiratory rate in unpremedicated elderly patients of ASA physical status 1 to 3 who underwent cataract surgery under retrobulbar anaesthesia. In group A no air suction was used. In group B suction was applied under the sterile drapes to avoid rebreathing of CO2. In group A transcutaneous partial CO2 pressure and respiratory rate significantly increased compared with baseline, whereas in group B they remained constant. In both groups transcutaneous partial O2 pressure and oxygen saturation as measured by pulse oximetry significantly rose after insufflating oxygen 31.min-1. Heart rate and mean arterial blood pressure remained constant. Our results demonstrate that the application of suction near the patient's head prevents CO2 rebreathing and subsequent hypercapnia associated with an elevated respiratory rate. The use of suction makes it unnecessary to raise oxygen administration. Suction combined with monitoring of partial CO2 pressure using transcutaneous sensors should be used in all ophthalmological operations under retrobulbar anaesthesia.

Aged↗

Fine needle cytology of palpable head and neck lesions: a comparison of sampling methods with and without suction.

Patients attending the ear, nose and throat (ENT) department at St James's University Hospital, Leeds, UK, for evaluation of palpable head and neck lesions have a fine needle cytology (FNC) specimen taken and receive the result at the same out-patient visit. This study was designed to discover if there is a significant difference in the efficiency of the methods with and without suction. The method was chosen randomly on each occasion and the adequacy or otherwise of the specimen was determined taking into account the site and nature of the lesion and the total cellularity of the sample. The level of blood contamination was also compared by each method. When benign and malignant lesions from all sites were analysed together the method with suction produced a significantly higher number of adequate samples than the method without suction. The exception was in the case of samples from lymph node lesions measuring < 1 cm, where adequate specimens were only obtained without suction. The non-suction technique was particularly poor at sampling salivary gland lesions in the 1-1.5 cm category. There was no significant difference in the level of blood contamination between the two methods at any site. These results are at variance with most other similar studies and possible reasons for this are discussed.

Adolescent↗

Tracheal suctioning: an exploration of nurses' knowledge and competence in acute and high dependency ward areas.

BACKGROUND AND RATIONALE: With an increasing demand for intensive care beds more nurses in acute and high dependency wards will be expected to care competently for patients with tracheostomy tubes. Tracheal suctioning is an essential aspect of effective airway management. However, this has many associated risks and complications, ranging from trauma and hypoxaemia to, in extreme cases, cardiac arrest and death. It is imperative that nurses are aware of these risks and are able to practice according to current research recommendations. Aims. This study was designed to explore nurses' knowledge and competence in performing tracheal suctioning in acute and high dependency ward areas and to investigate discrepancies between knowledge and practice using method triangulation. METHODS: Twenty-eight nurses were observed using nonparticipant observation and a structured observation schedule. Each subject was interviewed and questioned about their tracheal suctioning practices, and subsequently completed a knowledge-based questionnaire. Scores were allocated for knowledge and practice. FINDINGS: The findings demonstrated a poor level of knowledge for many subjects. This was also reflected in practice, as suctioning was performed against many of the research recommendations. Many nurses were unaware of recommended practice and a number demonstrated potentially unsafe practice. In addition, there was no significant relationship between knowledge and practice. However, during the interviews, many nurses were able to provide a rationale for specific aspects of practice that were perhaps not based on current research recommendations. CONCLUSIONS: The study raised concern about all aspects of tracheal suctioning and has highlighted the need for changes in practice, clinical guidelines and focused practice-based education.

Clinical Competence↗

Effect of PEEP and suction via chest drain on functional residual capacity and lung compliance after surgical repair of congenital diaphragmatic hernia: preliminary observations in 5 patients.

BACKGROUND/PURPOSE: Congenital diaphragmatic hernia (CDH) is associated with pulmonary hypoplasia that limits survival. The authors' knowledge on lung mechanics and lung volumes in these patients with hypoplastic lungs is still limited. Therefore, the authors performed measurements of functional residual capacity (FRC), compliance of the respiratory system (CRS), and tidal volume in 5 full-term infants (gestational age, 38 to 40 weeks; birth weight, 2,800 to 3,530 g) before and after surgical repair of neonatal CDH. METHODS: The authors studied the influence of different levels of positive end-expiratory pressure (PEEP) and suction via inserted ipsilateral chest tube connected to a water seal on lung volume and lung mechanics. A computerized tracer gas (SF6) washout method was used for serial measurements of FRC. Compliance of the respiratory system was determined according to insufflatory method. RESULTS: The authors found a preoperative compliance between 1.5 and 3.9 mL/kPa/kg and a preoperative FRC between 9.1 and 12.9 mL/kg indicating severe hypoplasia of the lungs in all patients. Immediately after surgical repair of CDH, compliance decreased to 85% (78% to 91%) of preoperative value, and FRC increased to 132% (110% to 150%) of preoperative value under mechanical ventilation while at 4 cm of water of PEEP and at -10 cm of water of suction via chest drain with the need of high fraction of inspired oxygen. After reduction of PEEP from 4 to 2 or 1 cm of water and lowering suction from -10 cm of water to -2 or 0 cm of water FRC decreased to 103% (80% to 122%) of preoperative value and compliance, and tidal volume improved to 135% (110% to 147%) of preoperative value resulting in increased alveolar ventilation, correction of acidosis and improvement in oxygenation. During the first days after surgery inadequate high PEEP or strong suction via chest tube drainage resulted in increase in FRC paralleled by decrease in compliance indicating overdistension of these hypoplastic lungs. CONCLUSIONS: The data show that overdistension of hypoplastic lungs in infants with CDH can be detected and excluded by repeated measurements of FRC and compliance in these critical ill infants. These data might help setting appropriate ventilator parameters, adequate suction via chest drain, and thereby improve gas exchange and outcome.

Chest Tubes↗

Irrigation-suction straw sheath system for a rigid endoscope during endonasal endoscopic pituitary surgery.

OBJECTIVE: One of the most problematic conditions during endonasal endoscopic pituitary surgery is blurred endoscopic vision caused by blood or bone dust. To address this problem we used a new device, the irrigation-suction straw sheath system originally developed for endoscopic sinus surgery in rhinology, for the endoscopic pituitary surgery. METHODS: The irrigation-suction straw system (K-endosheath; Koken Co., Tokyo, Japan) consists of a flattened disposable straw catheter which can be attached on a rigid endoscope. When the endoscope is inserted into the oblong catheter, two gaps remain on either side of the endoscope. Through each of these gaps irrigation and continuous suction are performed respectively. RESULTS: Clear vision could be immediately obtained by pressing the button to release the irrigation water onto the endoscope's front lens. Even targeted irrigation during drilling was possible. Above all, continuous suction was useful to clear the operative field of blood, smoke, or bone dust, ensuring the safety and uninterrupted progress of the procedure. CONCLUSION: This irrigation-suction system has proved to be very useful and easy to use for endonasal endoscopic pituitary surgery. Further development of such new devices and instruments specialized for endonasal endoscopic pituitary surgery will promote the increased use of this minimally invasive technique in neurosurgery.

Blood↗

The effect of behavioural states on cerebral oxygenation during endotracheal suctioning of preterm babies.

Near infrared spectroscopy (NIRS) was used to investigate the effect of behavioural states on changes of oxygenated (O2Hb), deoxygenated haemoglobin (HHb) and total haemoglobin (tHb), during endotracheal suctioning. In an open prospective design, NIRS measurements have been done during 20 suctioning episodes in 13 preterm neonates. Heart rate, arterial oxygen saturation, and carbon dioxide tension were monitored continuously. Behavioural state (BS) observations were made and documented as well. The statistical analysis showed that in patients who were active, with crying periods during suctioning (behavioural states 4-5), changes of oxygenated (p < 0.005) and deoxygenated haemoglobin (p < 0.05), as well as of arterial oxygen saturation (p < 0.05) and heart rate (p < 0.05) were significantly greater than in patients who were quiet with predominant behavioural state 1, 2 and 3. These results underline the influence of behavioural states on the physiological answers to endotracheal suctioning. NIRS proved to be a valuable tool to evaluate possible harmful effects of different suctioning techniques.

Cerebrovascular Circulation↗

Rectal suction biopsy: can it be sufficient to diagnose neuronal intestinal dysplasia?

Rectal suction biopsy is the diagnostic procedure of choice in aganglionosis even if only mucosal tissue is obtained. In neuronal intestinal dysplasia it is essential to include parts of the submucous layer. Therefore some biopsies are unsuitable because they lack submucous tissue. In a retrospective analysis (1991-1993) this occurred in 34.9% of our biopsies. These samples were taken without attention to the level of suction. Prospectively we compared suction biopsies taken by a standard suction level (250-300 cm water column) with excision biopsies taken by scissors under speculum exposure in ten consecutive patients. Submucosa was missed in only one biopsy each, but two excision biopsies were made useless by mechanical traumatization. We conclude a correctly practised rectal suction biopsy still remains the procedure of choice for diagnostic screening in malformations of the enteric nervous system.

Biopsy↗

The Lithovac: new suction device for the Swiss Lithoclast.

Minimal invasiveness characterizes modern stone therapy. Several years ago, we presented the Swiss Lithoclast, a ballistic system for endoscopic stone therapy. Its disintegrational power is superior to that of the other intracorporeal lithotripsy devices, and it has gained great recognition. Now, special probes (Lithovac) have been developed to combine lithotripsy with suction. These probes differ in width (1.6, 3.5, or 4 mm) and length depending on the intended location of use (kidney, ureter, bladder). The probes were tested in a standardized stone model. The variable suction energy counteracts the propulsive energy of the Lithoclast. Clinical experience could be gained with stones in the urinary bladder, Kock pouches, the ureter, and the kidney. There were no complications related to either the Lithoclast or the Lithovac. In staghorn stones, small (< 2 mm) pieces could be removed easily during lithotripsy. Fragments as large as 3.5 mm could be evacuated with the Lithovac after removing the Lithoclast probe. Using the suction, clear vision could be achieved (especially useful in struvite stones). In the ureter, a learning curve had to be overcome to balance fluid inflow and suction pressure. Otherwise, the ureter may collapse. However, this was possible in all patients. Using the single-shot mechanism, stones were broken up fast. The fragments could be dragged to the Lithoclast probe with the Lithovac. No pushback happened. In bladder and Kock pouch stones, suction may not be enough to hold the stone to the probe, but it is of great value to keep a small volume in the bladder/pouch and still have excellent visibility. The Lithovac is a useful tool in all endoscopic applications of the Lithoclast.

Endoscopy↗

Target concentrations of remifentanil with propofol to blunt coughing during intubation, cuff inflation, and tracheal suctioning.

BACKGROUND: The target blood concentrations of propofol and remifentanil, when used in combination, required to blunt the cough response to tracheal intubation, cuff inflation, and tracheal suctioning without neuromuscular blocking agents are not known. METHODS: In a randomized prospective study, 81 patients were enrolled to determine which of three target remifentanil blood concentrations was required to blunt coughing during intubation, cuff inflation, and tracheal suctioning. Anaesthesia was achieved with propofol at a steady effect-site concentration of 3.5 microg ml(-1). The target blood remifentanil concentrations were 5, 10, or 15 ng ml(-1). These concentrations were maintained for 12 min before intubation. RESULTS: There was no cough response to intubation in more than 74% of patients and no significant difference in the incidence of coughing with intubation between the three groups. Significant difference in coughing, diminishing with increasing remifentanil target concentration, was observed with cuff inflation (P=0.04) and tracheal suctioning (P=0.007). Bradycardia and hypotension was more frequent with the remifentanil target concentration of 15 ng ml(-1). Tracheal suctioning resulted in more coughing than intubation (P=0.01) or cuff inflation (P=0.004). CONCLUSION: Target remifentanil blood concentrations of 5, 10, and 15 ng ml(-1) associated with a 3.5 microg ml(-1) propofol target blood concentration provided good intubating conditions and absence of cough about 75% of the time. Higher target remifentanil concentrations were associated with less coughing during tracheal tube cuff inflation and tracheal suctioning.

Adolescent↗

A dressing system providing fluid supply and suction drainage used for continuous or intermittent irrigation.

In this article a dressing system is described that is capable of providing continuous or intermittent wound irrigation. It is based on a felt dressing provided with an adhesive cover and ports for fluid supply and suction drainage. At continuous irrigation (approximate rate, 70 ml/h), a 1-L fluid bag and a siphon about 30 cm in height are used; at intermittent irrigation (approximate rate, 60 ml/min), a 60-ml fluid bag and a suction balloon are used. In an experimental set-up it was shown that the supplied fluid diffused throughout the dressing felt and that the felt was partly saturated both during continuous and after intermittent irrigation, the effect of gravity being counteracted by capillary force and suction. The suction pressure at the drainage port and within the occlusively applied felt showed a linear relationship. The drainage of particles, while relatively impeded at low flow rates, was satisfactory at rates recommended for clinical use. The dressing felt was inert to adherence of bacteria and white blood cells. This dressing system would seem to provide access to the whole wound surface for active therapy through fluid supply and suction drainage.

Bandages↗

Selective bronchial suctioning in the adult using a curve-tipped catheter with a guide mark.

Our results of previous and successive studies indicate that torque control of curve-tipped catheters is easily accomplished by placing a guide mark on the catheter. Thus, a guide mark was made on a curve-tipped 14 FG Portex suction catheter using a felt pen. The efficacy of selective bronchial suctioning using this catheter was studied in 50 patients. Directed suctioning of the left and right bronchial passages was performed in each patient 3 times and once, respectively, with the head in the midline position. The success rate of left bronchial suctioning was 92% (138/150 attempts) and success in right bronchial suctioning 98% (49/50 attempts). The curve-tipped catheter with a guide mark significantly improved the success rate of left bronchial entry over the previous rate from 50% to 92%.

Bronchi↗

Effects of music therapy on oxygen saturation in premature infants receiving endotracheal suctioning.

The purpose of this study was to investigate how premature infants' oxygen saturation changed in response to music therapy while they were receiving endotracheal suctioning. A convenience sample of 30 premature infants was selected from three neonatal intensive care units. A one-group repeated measures design was adopted for this study. The oxygen saturation of all subjects was first measured while they were receiving endotracheal suctioning during a four-hour control period with regular care. Then, four hours after the control period was completed, an experimental period began in which the music " Transitions " was played. One minute before suctioning, the level of oxygen saturation was measured to provide the baseline data. During a period of 30 minutes after suctioning, the oxygen saturation was recorded every minute to analyze the clinical effects of music therapy. The results showed that premature infants receiving music therapy with endotracheal suctioning had a significantly higher SPO(2); than that when not receiving music therapy (p <.01), and the level of oxygen saturation returned to the baseline level faster than when they did not receive music therapy (p <.01). Accordingly, it is hoped that giving appropriate music therapy as developmental care to premature infants when performing any nursing intervention may enhance not only the quality of nursing care but also quality of the infant's life.

Female↗

The decidual suction method: a new way of collecting decidual tissue for functional and morphological studies.

BACKGROUND: Studies of extravillous trophoblasts and placental bed spiral arteries are essential for a better understanding of pathological pregnancies such as preeclampsia, intrauterine growth restriction and diabetes mellitus. A major challenge is to obtain representative and sufficient tissue for morphological and functional investigations. Currently, tissue material is mostly harvested by placental bed biopsy (PBB). We describe a new suction method to obtain a larger volume of decidual tissue from the placental bed. METHODS: Tissue was harvested in 51 cesarean sections by vacuum suction of the placental bed. Sections from formalin-fixed, paraffin-embedded tissue were routinely stained with hematoxylin and eosin (H&E), immunostained with a panel of antibodies and morphologically examined for the presence of trophoblasts and spiral arteries. The results were compared with those from archive material from PBBs and placental basal plate sections (BPSs). Short-term adverse events were registered for the study patients. Long-term complications were registered from medical charts of 151 women having undergone the decidual suction method (DSM), with a follow-up of 38-60 months. RESULTS: In 86% (n = 44), one random section from the decidual suction material demonstrated at least one spiral artery. In 37% (n = 19), six or more spiral arteries were present. All sections revealed extravillous trophoblasts. No short- or long-term morbidity was recorded. CONCLUSIONS: The decidual suction method represents an important improvement in the work to obtain sufficient decidual tissue for morphological and functional studies of extravillous trophoblast function and spiral artery adaptation. The method is safe, as no short- or long-term complications were registered.

Decidua↗

Development of a suction detection system for axial blood pumps.

Axial flow blood pumps for cardiac assistance have proven their clinical viability and benefit in recent years. However, the clinical systems to date have no direct mechanism to decrease pump speed when adequate supply is not available. This may lead to ventricular collapse or increase the probability of hemolysis and thrombotic risks. Based on various experiences with left ventricular assist device (LVAD) patients in various states of recovery, at implant, in the intensive care unit, in the standard ward, and during physical exercise, 11 different algorithms were developed for the automatic detection of ventricular suction. These detection algorithms analyze the flow pattern for the presence of distinct suction indicators. For selection and optimization of the algorithms, 1000 records from approximately 100 patients were collected. Each record contains 5 s of pump flow, current, and arterial pressure. Three experts classified these records in terms of suction probability and other abnormalities. The optimization was developed in Matlab, capable of solving a fifth-dimensional optimization problem with 256 different algorithm combinations. The optimization resulted in a set of 6 algorithms, each with specific thresholds. The system detects 100% of the known suction events with 0.28% of false-positive interpretations. If tuned to avoid any false-positive detection, 90.7% of the certain events would be detected. A strategy for the development of a robust suction detection system for axial blood pumps was found. This system will be integrated into an automatic pump speed control system to provide adequate perfusion for the LVAD recipient, without excessive unloading of the ventricle.

Algorithms↗

Transcatheter radiofrequency ablation of atrial tissue using a suction catheter.

Closed chest ablative technique that avoid barotrauma would be attractive for ablation at thin walled cardiac structures, such as the atrial free wall or coronary sinus. Transcatheter radiofrequency (RF) currents produce tissue necrosis the size of which is dependent on the contact between the tissue and the electrode. In order to assess the effects of transvenous RF ablation of atrial free wall using a suction electrode catheter, we delivered in ten dogs, one single unmodulated RF pulse 1.2 MHz, in a unipolar mode, through the distal electrode of a lumen catheter (USCI 8F) (USCI, Billerica, MA USA) located in the right appendage. During the pulse an 80 KPa vacuum depression was applied to the lumen of the catheter. Each pulse had a 10 seconds duration and the mean delivered power was 4.3 +/- 1.4 W. Aortic pressure and electrocardiogram were monitored during the procedure. A right atrial electrophysiological study was performed at the ablated site, at control, after suction application and after RF pulse delivery. The animals were sacrificed after 14 or 21 days. Atrial pacing threshold values decreased after suction application in comparison to control values after the pulse (0.42 +/- 0.06 vs 0.60 +/- 0.23 mA, P less than O.05) but increased after the pulse delivery (2.60 +/- 1.85 mA, P less than 0.01). In contrast, the atrial effective refractory period did not significantly change after suction, nor after RF pulse delivery. Aortic pressure remained unchanged throughout the procedure. Complex arrhythmias were not observed during or after RF pulse delivery. One dog died suddenly at the first day after ablation, but this death was most probably unrelated to RF ablation. Anatomic lesions had a length of 8.8 +/- 3.3 mm, a width of 4.6 +/- 2.5 mm and a depth of 3.6 +/- 1.1 mm. They were transmural in nine of the ten dogs but without atrial wall perforation in any case. Lesions suggesting tissue volatilization were present in four dogs. These results demonstrate that low energy RF currents delivered with a suction electrode catheter can produce transmural necrosis of free wall, without risk of perforation. Such ablative technique would be of interest for ablation of right sided accessory pathways or atrial ectopic foci. Further experimental data are required in order to define the optimal energy level required to avoid tissue volatilization.

Animals↗

Changes in cerebral oxygenation and cerebral blood volume during endotracheal suctioning in ventilated neonates.

The effect of endotracheal suctioning on cerebral haemodynamics was investigated in 29 newborn infants with a mean gestational age of 31 weeks (range 25-40 weeks). Prior to one of two suctioning procedures, the inspiratory fraction of oxygen was increased by 10%. Brain oxygenation and total haemoglobin concentration were estimated continuously by near infrared spectroscopy. Mean arterial blood pressure, arterial blood oxygen saturation and carbon dioxide tension were recorded simultaneously. Brain oxygenation decreased in parallel with arterial oxygen saturation during suctioning. Preoxygenation ameliorated the decrease in brain oxygenation and arterial oxygen saturation whereas there was no benefit with regard to the changes in total haemoglobin concentration, carbon dioxide tension or mean arterial pressure. Changes in total haemoglobin concentration were related closely to concomitant changes in carbon dioxide tension (p less than 0.0001) but unrelated to changes in mean arterial pressure or arterial oxygen saturation. Our findings suggest that cerebral blood volume may react to changes in carbon dioxide tension during endotracheal suctioning in mechanically ventilated neonates. Apparently, preoxygenation prior to suctioning does not ameliorate the stress in normoxic infants.

Blood Pressure↗

A survey of suctioning practices among physical therapists, respiratory therapists and nurses.

OBJECTIVE: To assess the current tracheal and oropharyngeal suctioning practice variability within and among the professions of physical therapy, respiratory therapy and nursing. DESIGN: A mail survey of physical therapists, respiratory therapists and registered nurses who perform suctioning. The survey instrument consisted of questions about professional characteristics, clinical suctioning practice and sociodemographics. SETTING: The survey was restricted to professionals practising within the province of Ontario. PARTICIPANTS: Random samples (n=448) were drawn from membership of the regulatory boards of all three professions. MAIN RESULTS: Fifty-eight per cent of respondents returned completed questionnaires. There was large variation in reports of gloving procedure (eg, double clean: 26% for physical therapists, 5% for respiratory therapists, 55% for registered nurses, P<0.0001) and technique of catheter use (sterile, inline or clean, P<0.01). There was also discrepancy in the techniques used to minimize harmful effects, ie, prelubrication with gel (83% for physical therapists, 54% for respiratory therapists, 17% for registered nurses, P<0.0001), use of hyperinflation (12% of physical therapists, 25% of respiratory therapists, 39% of registered nurses never hyperinflate) and use of instillation (7% of physical therapists, 0% of respiratory therapists, 19% of registered nurses never instill). However, there was agreement about the routine application of hyperoxygenation (74% or more) and there was almost perfect agreement (99% or more) within and across the three professions that secretion removal was the main indication for suctioning. CONCLUSIONS: The results of this study indicate a wide variation in suctioning techniques among physical therapists, respiratory therapists and registered nurses. Comparisons among professions revealed inconsistencies in some areas, such as the use of in-line catheters, gloving procedures, prelubrication and hyperinflation.

Cross-Sectional Studies↗

Clinical practice guidelines for suctioning the airway of the intubated and nonintubated patient.

OBJECTIVE: To provide physicians, physiotherapists, nurses and respiratory therapists with guidelines for the application of airway suctioning. DESIGN: This clinical practice guideline was developed using the model by Browman and colleagues. A working group of representatives from four professional colleges (nurses, physicians and surgeons, physiotherapists and respiratory therapists) and research experts was formed to conduct a systematic review, develop evidence-based recommendations and generate clinical practice guidelines. MEDLINE (1966 to 1998), CINAHL (1982 to 1997) and EMBASE (1974 to 1996) as well as the reference lists of identified articles were searched. Inclusion of articles was determined by at least two group members, and studies were classified according to type. Randomized, controlled; randomized; and nonrandomized crossover and comparative cohort trials were grouped by type of intervention and population for use in the development of recommendations. Other observational and animal studies dealing with adverse effects of suctioning were included in the review but were not used in the development of recommendations. Input on the evidence-based recommendations was sought and incorporated from members of all four professions and from experts on content and methodology. SETTING: Any setting (hospital or home) where suctioning is performed. POPULATION: Intubated and nonintubated adults, infants and children. RESULTS AND CONCLUSIONS: An attempt was made to develop recommendations in each of the subcategories of suctioning techniques addressed by at least one study. In some subcategories, definite recommendations were made (13 in adults, and three in children and infants); in other subcategories, insufficient evidence precluded recommendations. The recommendations addressed the following aspects of suctioning: preoxygenation, hyperinflation, insufflation, hyperoxygenation, hyperventilation, saline instillation, adaptor use, medication use, open and closed systems, and various types of catheters.

Adult↗