Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Silicon Compounds”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

The in vitro morphological effects of some current pre-treatments on dentin surface: a SEM evaluation.

This in vitro study morphologically evaluated the effect of some current surface pre-treatments on dentin, using scanning electron microscopy, and related these morphological alterations to clinical implications. The labial surfaces of 30 bovine lower incisors were ground to obtain a flat dentin surface and were finished with 600-grit SiC paper to produce standardized smear layers. The teeth were randomly divided into six groups of five each. Group 1 was the control group, smear layer covered dentin; Group 2 was etched with 37% phosphoric acid (PA) for 15 seconds; Group 3, 37% PA for 15 seconds, followed by 10% NaOCl for 60 seconds; Group 4, 10% NaOCl for 60 seconds; Group 5, a self-etching primer (Clearfil SE Bond, CSEB-primer) was applied for 20 seconds; Group 6, CSEB-primer for 20 seconds, followed by NaOCl for 60 seconds. The specimens were fixed, dehydrated, dried and analyzed by SEM. Treatment with 37% PA removed the smear layer, funneled the tubules and resulted in a collagen-rich surface which appeared to have collapsed in its outermost part, producing a dense surface layer covered with silica particles. When 37% PA treatment was followed by 10% NaOCl, the collagen network was removed to reveal an eroded, rough mineral surface with numerous lateral branches and larger than normal tubular orifices. The action of 10% NaOCl on the smear layer-covered dentin showed no significant alteration in surface morphology. The treatment with CSEB-primer dissolved the smear layer but only partially dissolved the smear plugs. The tubules did not present the typical funnel shape seen following PA treatment. These morphological aspects on dentin surface must influence bonding results. The dentin surface alterations produced by PA appeared to be a very severe demineralization pattern, quite irregular and less permeable to monomer infiltration, while the surface provided by the self-etching primer appeared to be a more uniform, less porous surface, and the association with simultaneous monomer infiltration may reduce the occurrence of mistakes in clinical bonding procedures.

Acid Etching, Dental↗

Relationship between composite contraction stress and leakage in Class V cavities.

PURPOSE: The purpose of this study was to determine the relationship between polymerization contraction stress and leakage in Class V composites. METHODS: A microfill (Heliomolar) and two minifill hybrid composites (Herculite, Z100) were tested. Maximum contraction stress (n = 5) for the composites was evaluated in a MTS machine at a C-factor of 3 (ratio of bonded to non-bonded surface area). Composite was placed in the gap between the surfaces of glass stubs that had been air abraded, silane treated and coated with a layer of resin adhesive. Specimens were light-cured through the top glass stub for 60 seconds and maximum force was recorded during the first 10 minutes. Leakage (n = 10) was evaluated by cutting cylindrical cavity preparations with all enamel margins (C-factor = 3) in bovine incisors. The cavities were treated with two layers of Scotchbond MP adhesive. Composites were applied in one increment, light-cured at the same intensity used in the stress tests, and immediately finished on SiC paper. After 1 day in water, the restorations were placed in silver nitrate, developed and evaluated as a single cross-section (2-D) and multiple cross-sections (3-D) for leakage: 0 (none), 1 (minimal leakage), 2 (to the DEJ), 3 (to line angle), 4 (along the pulpal wall). RESULTS: The maximum stresses (MPa) recorded were lowest for Heliomolar (7.0 +/- 0.4), intermediate for Herculite (10.5 +/- 0.6) and greatest for Z100 (11.6 +/- 1.3). 3-D leakage was as follows: Heliomolar--two specimens scored 1, seven scored 2 and one scored 3; Herculite--six scored 2 and four scored 3; Z100--eight scored 3 and two scored 4. The Kruskal-Wallis test showed a significant difference in leakage for the three composites (P < 0.05), and leakage was greater when evaluated in 3-D. The leakage results correlated with the stress values, i.e. composites with higher contraction stress showed more extensive marginal leakage.

Acrylic Resins↗

High-temperature separation with polymer-coated fiber in packed capillary gas chromatography.

High-temperature gas chromatographic separation of several synthetic polymer mixtures with Dexsil-coated fiber-packed columns was studied. A bundle of heat-resistant filaments, Zylon, was longitudinally packed into a short metal capillary, followed by the conventional coating process with Dexsil 300 material. Prior to the packing process the metal capillary was deactivated by the formation of a silica layer. The typical size of the resulting column was 0.3-mm i.d., 0.5-mm o.d., 1-m length, and packed with about 170 filaments of the Dexsil-coated Zylon. The column temperature could be elevated up to 450 degrees C owing to the good thermal stability of the fiber, Dexsil coating, and metal capillary; furthermore, this allowed the separation of low-volatile compounds to be studied.

Chromatography, Gas↗

Ultra long SiC/SiO2 core-shell nanocables from organic precursor.

Ultra long SiC core and SiO2 shell nanocables have been prepared by pyrolysis of poly(dimethyl siloxane) at 1050 degrees C in flowing Argon. The longest nanocable can be up to at least 6 mm. Transmission electron microscopy observations indicate that the diameter of the cores varies from about 3 to 18 nm, and the thickness of the outer sheaths varies from about 6 to 45 nm and that the cores are crystalline and the sheaths are amorphous. The growth of the nanocables may be governed by a chemical vapor solid process. The nanocables exhibit good photoluminescence property.

Argon↗

A short- and long-term shear bond strength study using acids of varying dilutions on bovine dentine.

OBJECTIVES: The purpose of this study was to evaluate the short-(24 h) and long-(180 day) term shear bond strengths of resin to bovine dentine etched with varying dilutions of aqueous solutions of phosphoric and maleic acids. METHODS: Bovine dentine surfaces were prepared using water irrigated #600 grit SiC paper. The dentine surfaces were etched in groups of 10 teeth using various dilutions of phosphoric or maleic acid. Using the Scotchbond Multipurpose System (SBMP; 3M Co., MN, USA) and a wet technique the etched surfaces were primed and unfilled bonding resin (UBR) was applied to the dentine surface within the confines of a gelatin cylinder. A cylinder of filled resin (Z 100; 3M Co., MN, USA) was then photocured and the specimens were then stored in water for 24 h or 180 days prior to shear bond testing to failure. RESULTS: The results showed that high bond strengths were recorded using acids which were more dilute than those commercially available. There were also indications that phosphoric acid is not the etching acid of choice for the SBMP system. CONCLUSIONS: The results of this study showed that high bond strengths can be achieved in dentine using etching acids which are more dilute than those commercially available. Maleic acid appears to be the etchant of choice for the SBMP system.

Acid Etching, Dental↗

Factors affecting the shear bond strength of bonded composite inlays.

PURPOSE: This article analyzes the influence of different pretreatments on the bond strength between inlays and the resin cement of three different composite inlay systems: Z-100, Targis, and Art Glass. MATERIALS AND METHODS: Four separate treatments of the composite-bonding agent interface were investigated: (1) untreated surface, (2) grinding, (3) sandblasting, and (4) sandblasting followed by silane treatment. Surface topography, roughness, and shear bond strength were evaluated using digital scanning electron microscopy, confocal laser scanning profilometry, and a Lloyd LRX equipped for shear bond testing, respectively. RESULTS: The bond strength is presented both with respect to composite surface pretreatment and with respect to different composite inlay systems. Independent of the composite inlay system, the sandblasted and silane-treated surface was found to give the highest bond strength values, followed by the sandblasted and ground surfaces. The untreated surface showed the lowest bond strength. For pretreated surfaces, Targis showed the highest (P < 0.05) bond strength values, followed by Art Glass and Z-100. This distribution, however, was reversed for the untreated interface, where Z-100 showed the highest bonding strength (P < 0.05). CONCLUSION: Surface pretreatment and roughness as well as the inlay material have an impact on the bond strength and the retention of composite inlays.

Adhesiveness↗

The influence of tubule density and area of solid dentin on bond strength of two adhesive systems to dentin.

PURPOSE: To determine the correlation between the tubule density (TD) and the area occupied by solid dentin (ASD) with the bond strength of one conventional and one self-etching adhesive system to dentin. MATERIALS AND METHODS: The crown of extracted human third molars was transversally sectioned with a diamond saw to expose either superficial, middle, or deep dentin. The three groups of dentin surfaces were randomly divided and bonded with either Clearfil Liner Bond 2V (LB) or Prime & Bond 2.1 (PB) adhesive systems according to manufacturer's directions. Resin composite buildup crowns (10.0 mm high) were incrementally constructed on the bonded surfaces and the teeth stored in water at 37 degrees C. After 24 h of storage, the teeth were vertically, serially sectioned in both x and y directions to obtain several bonded sticks of approximately 0.7 mm2 cross-sectional area. Each stick was tested in tension in a EMIC DL-500 tester at 0.5 mm/min until failure. After testing, the dentin side of the fractured specimen was gently abraded with a 1000-grit SiC paper, etched with 37% phosphoric acid for 15 s and allowed to air dry. SEM micrographs at 1000x and 4000x magnification were taken to permit calculation of the TD (number of tubules/mm2) and ASD (% of total area) at the site of fracture. Correlation between TD and ASD with the bond strength data was performed by linear regression. All statistical analysis was done with alpha = 0.05. RESULTS: Overall bond strength (MPa) for LB was 26.0 +/- 10.2, and 42.6 +/- 15.2 for PB. There was a significant direct relationship between bond strength and ASD for both materials (r2 = 0.20, p < 0.05 and r2 = 0.66, p < 0.01, respectively for LB and PB). PB bond strength dropped significantly as the TD increased (r2 = 0.63, p < 0.05), while LB was not sensitive to TD (r2 = 0.05, p > 0.05). Mean bond strength of PB was significantly higher than LB for both superficial and middle dentin (p < 0.05), while there was no significant difference for deep dentin (p > 0.05). CONCLUSION: Regional variations in TD and ASD may modify bond strength of both conventional and self-etching adhesive systems. Bonding sites with larger ASD seem to yield higher bond strengths regardless of the type of adhesive system used.

Acetone↗

Tensile bond strength of resin-modified glass-ionomer cement to microabraded and silica-coated or tin-plated high noble ceramic alloy.

PURPOSE: The purpose of this study was to evaluate the influence of alloy surface microabrasion, silica coating, or microabrasion plus tin plating on the tensile bond strengths between a resin-modified glass-ionomer luting cement and a high-noble alloy. Bond strength between the microabraded alloy specimens and conventional glass-ionomer cement or resin cement were included for comparison. MATERIALS AND METHODS: One hundred twenty uniform size, disk-shaped specimens were cast in a noble metal alloy and divided into 6 groups (n = 10 pairs/group). The metal surfaces of the specimens in each group were treated and cemented as follows. Group 1: No surface treatment (as cast, control), cemented with a resin-modified glass-ionomer cement. Group 2: Microabrasion with 50-microm aluminum oxide particles, resin-modified glass-ionomer cement. Group 3: A laboratory microabrasion and silica coating system, resin-modified glass-ionomer cement. Group 4: Microabrasion and tin-plating, resin-modified glass-ionomer cement. Group 5: Microabrasion only, conventional glass-ionomer cement. Group 6: Microabrasion and tin-plating, conventional resin cement. The uniaxial tensile bond strength for each specimen pair was determined using an Instron Universal Testing Machine (Instron Corp, Canton, MA). Results were analyzed using a one-way analysis of variance (alpha = 0.05) and a Tukey post-hoc analysis. RESULTS: Mean bond strength: Group 1: 3.6 (+/- 1.5) MPa. Group 2: 4.2 (+/-0.5) MPa. Group 3: 6.7 (+/- 0.9) MPa. Group 4: 10.6 (+/- 1.8) MPa. Group 5: 1.1 (+/- 0.4) MPa. Group 6: 14.6 (+/- 2.3) MPa. Group 6 was significantly stronger than Group 4. The bond strength of specimens cemented with the resin-modified glass-ionomer cement using microabrasion and tin-plating (Group 4) was significantly stronger than all other groups except the resin cement with microabrasion and tin-plating (Group 6). CONCLUSION: Microabraded and tin-plated alloy specimens luted with the resin-modified glass-ionomer cement resulted in the greatest mean tensile strengths for the resin-modified glass-ionomer cement groups. This strength was 73% of the mean tensile strength of microabraded specimens luted with resin cement.

Aluminum Oxide↗

A Convergent Strategy for the Asymmetric Synthesis of Enantiomerically Pure Bicyclic Compounds by Using a Silicon-Directed Cycloaddition Reaction: The Synthesis of Enantiomerically Pure Bicyclo

An asymmetric allylmetalation followed by a silicon-stereodirected cycloaddition gives enantiomerically pure bicyclic compounds. The synthesis of enantiopure 1 (see scheme) in a yield of 65-74 %, 93 % ee, and >98 % de provides an illustration of the efficacy of the method. The preferential formation of 1 rather than its diastereoisomer (32:1), during the cycloaddition step, matches the result predicted by RHF and density functional theory studies.

Journal Article↗

Long-term water-aging of whisker-reinforced polymer-matrix composites.

Long-term water exposure may degrade polymer-matrix composites. This study investigated the water-aging of whisker composites. It was hypothesized that whiskers would provide stable and substantial reinforcement, and that whisker type would affect water-aging resistance. Silica-fused Si(3)N(4) and SiC whiskers were incorporated into a resin. The specimens were tested by three-point flexure and nano-indentation vs. water-aging for 1 to 730 days. After 730 days, SiC composite had a strength (mean +/- SD; n = 6) of 185 +/- 33 MPa, similar to 146 +/- 44 MPa for Si(3)N(4) composite (p = 0.064); both were significantly higher than 67 +/- 23 MPa for an inlay/onlay control (p < 0.001). Compared with 1 day, the strength of the SiC composite showed no decrease, while that of the Si(3)N(4) composite decreased. The decrease was due to whisker weakening rather than to resin degradation or interface breakdown. Whisker composites also had higher moduli than the controls. In conclusion, silica-fused whiskers bonded to polymer matrix and resisted long-term water attack, resulting in much stronger composites than the controls after water-aging.

Analysis of Variance↗

Ultrastructural study of a glass ionomer-based, all-in-one adhesive.

OBJECTIVE: Reactmer Bond (Shofu Inc., Kyoto, Japan) is a glass ionomer (GI) based, tri-curable, all-in-one, filled adhesive. Both fluoroaluminosilicate glass (FASG) and fully pre-reacted glass (F-PRG) are used as fillers. This study examined the ultrastructure and elemental composition of resin-dentine interfaces that were treated with this adhesive. METHODS: Dentine disks prepared from human third molars were abraded with either 600- or 60-grit SiC paper to create smear layers of different thickness. They were bonded using Reactmer Bond. Cryo-fractured dentine surfaces devoid of smear layers were also bonded by chemical-activation and GI reaction without additional light-activation, or allowing the GI reaction to proceed for 1min before the adhesive was applied and light-activated. Undemineralised and demineralised sections were processed for TEM examination and STEM/EDX analysis. RESULTS: Resin-dentine interface from specimens with smear layers consisted of a mineral-dense surface layer that resided on top of a partially demineralised dentine. The partially demineralised zone was considerably thicker in the 600-grit than the 60-grit specimens. In smear layer-free specimens that were cured by chemical-activation/GI modes only, the surface layer concurred with the partially demineralised zone, and appeared as an electron-dense layer over the undemineralised intact dentine. Smear layer-free specimens that were cured by the light-activation of the partially neutralised adhesive contained incomplete amorphous surface layers only. Apart from colloidal silica, FASG fillers were the predominant filler type within the resin matrices. Peripheral hydrogel layers that contained electron-dense "seeds" were found around the FASG fillers. F-PRG fillers were only sparsely observed. In specimens that were laboratory demineralised with formic acid, phase separation of the unstained resin matrices into electron-dense and electron-lucent domains occurred. Artefactual dendritic deposits were found within the electron-dense domains. CONCLUSIONS: The presence of a surface interaction layer on top of a partially demineralised zone along the resin-dentine interface suggests that either a GI-type reaction or precipitation of insoluble carboxylate salts around remnant apatite crystallites may occur when this single-step adhesive interacts with dentine. Appearance of artefactual dendritic deposits suggests that continuous ion movement is possible within the hydrophilic portion of the resin matrix in this fluoride-releasing adhesive.

Aluminum Compounds↗

Evaluation of occupational exposure to mixed dusts and polycyclic aromatic hydrocarbons in silicon carbide plants.

Workers in the silicon carbide industry have experienced occupational health diseases, particularly lung disorders such as silicosis. The silicon carbide production process mainly employs petroleum coke, sawdust, pure crystalline silica and graphite. Since crystalline silica is present in the occupational environment, the airborne dust content of various polymorphs of silica, especially quartz, cristobalite and tridymite, was determined by X-ray diffraction analysis. The analytical method was modified to eliminate graphite, since it overlaps with the main diffraction plane of quartz. Exploratory field surveys were conducted to identify the minerals present in that occupational environment and to evaluate the validity of the analytical method. The surveys provided information on the mineralogical nature of the dust, its respirable content and the concentration of silica polymorphs. Polycyclic aromatic hydrocarbons also were measured, and the effect of their adsorption on graphite was evaluated.

Air Pollutants, Occupational↗

Excited-state reactions of an isolable silylene with aromatic compounds.

The first intermolecular reactions of the excited state of a silicon divalent compound (silylene) with benzene derivatives were discovered. Typically, when a benzene solution of an isolable silylene is irradiated with light of wavelengths longer than 420 nm at room temperature, the corresponding silacyclohepta-2,4,6-triene (silepin) is yielded quantitatively. The photochemical insertion of the silylene toward substituted benzenes occurs in general to give the corresponding substituted silepins. The insertion reaction is highly sensitive to the steric hindrance at a reacting C-C double bond in benzene; during the reactions of the silylene with substituted benzenes, only unsubstituted C-C double bonds in the benzene ring reacted selectively. The irradiation of the silylene in the presence of mesitylene afforded the insertion product to a benzylic C-H bond, indicative of the biradical nature of the excited-state silylene.

Journal Article↗

Effect of lanthanides on the relaxation rates of 89Y and 29Si in yttrium silicon oxynitride phases.

Additions of paramagnetic lanthanides are found to increase the relaxation rates of both 89Y and 29Si in the yttrium silicon oxynitride compounds Y2Si3N4O3 (N-melilite) and Y4Si2O7N2 (J-phase), allowing the observation of previously unreported 89Y magic-angle spinning nuclear magnetic resonance spectra of these phases. The dependence of the 89Y and 29Si relaxation rates was determined as a function of Yb3+ and Gd3+ concentration. Both the 29Si and 89Y resonances become broader with increasing Yb concentration, but at all lanthanide concentrations the 89Y spectrum of J-phase is broader than that of N-melilite, possibly due to a greater distribution of Y site geometries in the former. At concentrations below about 360 mumol g-1, the lanthanide ions appear to be incorporated in the lattice, but are not involved in covalent bonding to Y or Si. The effect of a series of lanthanides on the 89Y and 29Si relaxation rates and line widths is presented in terms of the lanthanide spin quantum numbers and magnetic moments. The most effective lanthanide was found to be Eu3+, giving fast relaxation (particularly for 89Y) and sharp lines.

Air Pollutants, Occupational↗

[Cholesterol, alpha-tocopherol, and retinoid concentrations in silicone oil used as a vitreous substitute].

OBJECTIVE: To verify the existence of organic lipophylic compounds in silicone oil extracted from human eyes following its use for previous retinal detachment, and to determine the intraocular permanence time of these substances in the oil. METHODS: Concentrations of retinoic acid, retinol, retinal, cholesterol and alpha-tocopherol were detected by HPLC in 23 samples of silicone oil extracted from patients with complicated retinal detachments. The time interval between the time of injection of the silicone oil and the subsequent assessment varied from 3 to 50 months (the permanence time). RESULTS: All tested compounds were found in the samples, but these were most commonly cholesterol and less frequently alpha-tocopherol. There was an inverse relationship between retinoic acid concentration and age (p=0.023), and a direct relationship between cholesterol concentration and permanence time (p=0.0008) at least up to 20 months. CONCLUSIONS: These findings confirm that silicone oil is not an inert substance but is capable of extracting lipophylic compounds from the intraocular tissues. There is a clear linear elevation of cholesterol levels with increased intraocular permanence time. This finding could be used to further establish a safe permanence time for intraocular silicone oil used in ophthalmologic surgery. More studies with larger samples are warranted to evaluate this further.

Adolescent↗

Oxidative degradation of hydrocortisone in presence of attapulgite.

Degradation of hydrocortisone in attapulgite suspensions was monitored by high-pressure liquid chromatography and UV spectrophotometry. The rate of oxidative degration of hydrocortisone was accelerated significantly in the presence of attapulgite. In addition, degradation appeared to be composed of two apparent first-order reactions rather than the single apparent first-order degradation reaction observed for hydrocortisone solutions. However, the same degradation products were obtained in both hydrocortisone solutions and attapulgite suspensions, indicating that interaction with attapulgite did not alter the degradation pathway. Kinetic and adsorption studies suggested that hydrocortisone is adsorbed weakly by attapulgite and undergoes oxidative degradation, which is catalyzed by adsorbed iron oxides or hydroxides as well as by structural ferric iron at the clay surface. Since clay minerals generally contain surface ferric iron, the potentiala for accelerating the oxidative degradation of drugs should be considered whenever clays and drugs are combined.

Bentonite↗

Interactions of attapulgite (fibrous clay) with human red blood cells.

The haemolytic potential of attapulgite (Senegal) has been investigated. When the particles were pretreated with dipalmitoyl phosphatidylcholine (DPPC) or with bovine serum albumin (BSA) at a concentration that would obtain maximum coverage of the particles by adsorption, a change in haemolysis was observed. The results indicate that haemolysis is strongly dependent on the surface state of the particles.

1,2-Dipalmitoylphosphatidylcholine↗