Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Photons”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Photonic band gap enhancement in frequency-dependent dielectrics.

We illustrate a general technique for evaluating photonic band structures in periodic d -dimensional microstructures in which the dielectric constant epsilon (omega) exhibits rapid variations with frequency omega . This technique involves the evaluation of generalized electromagnetic dispersion surfaces omega ( k--> ,epsilon) in a (d+1) -dimensional space consisting of the physical d -dimensional space of wave vectors k--> and an additional dimension defined by the continuous, independent, variable epsilon . The physical band structure for the photonic crystal is obtained by evaluating the intersection of the generalized dispersion surfaces with the "cutting surface" defined by the function epsilon (omega) . We apply this method to evaluate the band structure of both two- and three-dimensional (3D) periodic microstructures. We consider metallic photonic crystals with free carriers described by a simple Drude conductivity and verify the occurrence of electromagnetic pass bands below the plasma frequency of the bulk metal. We also evaluate the shift of the photonic band structure caused by free carrier injection into semiconductor-based photonic crystals. We apply our method to two models in which epsilon (omega) describes a resonant radiation-matter interaction. In the first model, we consider the addition of independent, resonant oscillators to a photonic crystal with an otherwise frequency-independent dielectric constant. We demonstrate that for an inhomogeneously broadened distribution of resonators impregnated within an inverse opal structure, the full 3D photonic band gap (PBG) can be considerably enhanced. In the second model, we consider a coupled resonant oscillator mode in a photonic crystal. When this mode is an optical phonon, there can be a synergetic interplay between the polaritonic resonance and the geometrical scattering resonances of the structured dielectric, leading to PBG enhancement. A similar effect may arise when resonant atoms that are coupled radiatively through resonance dipole-dipole interaction are placed in a photonic crystal.

Journal Article↗

Two-photon lasers based on intersubband transitions in semiconductor quantum wells.

We propose to make a two-photon laser based on intersubband (sublevel) transitions in semiconductor nanostructures. The advantages and feasibility of such a two-photon laser are analyzed in detail using the density matrix approach. Both one-photon and two-photon gains in a three subband quantum well structure are studied on the same footing to show how the two-photon gain can be maximized, while the competing one-photon gain is minimized. The results show that a sufficient two-photon gain can be achieved to overcome one-photon competition and the loss of a conventional semiconductor cavity, making intersubband transitions one of the very few feasible approaches to two-photon lasing.

Journal Article↗

Crassulacean Acid Metabolism and Photochemical Efficiency of Photosystem II in the Adaxial and Abaxial Parts of the Succulent Leaves of Kalanchoë daigremontiana Grown at Four Photon Flux Densities.

Kalanchoë daigremontiana, a species possessing crassulacean acid metabolism, was grown at four photon flux densities (1300, 400, 60, and 25 micromole photons per square meter per second). In leaves which had developed at 1300 and 400 micromole photons per square meter per second, CO(2) was mainly incorporated through the lower, shaded leaf surfaces, and the chlorenchyma adjacent to the lower surfaces showed a higher degree of nocturnal acid synthesis than the chlorenchyma adjacent to the upper surfaces. In leaves acclimated to 60 and 25 micromole photons per square meter per second, the gradient in CAM activity was reversed, i.e. more CO(2) was taken up through the upper than through the lower surfaces and nocturnal acidification was higher in the tissue next to the upper surfaces. Total net carbon gain and total nocturnal acid synthesis were highest in leaves which had developed at 400 micromole photons per square meter per second. Chlorophyll content was markedly reduced in leaves which had developed at 1300 micromole photons per square meter per second, especially in the exposed adaxial parts. There was also a sustained reduction in photosystem II photochemical efficiency as indicated by measurements of the ratio of variable over maximum chlorophyll a fluorescence. These findings suggest that, at high growth photon flux densities, the reduced activity of the exposed portions of these succulent leaves is caused by (a) the adverse effects of excess light, (b) together with a genotypic component which favors CO(2) uptake and acid synthesis in the abaxial (lower) leaf parts even when light is not or only marginally excessive. This latter component is predominant at medium photon flux densities, e.g. at 400 micromole photons per square meter per second. It becomes overridden, however, under conditions of deep shade when strongly reduced light levels in the abaxial parts of the leaf chlorenchyma severely limit photosynthesis.

Journal Article↗

Observation of stimulated emission by direct three-photon excitation.

Multiphoton processes, predicted theoretically in 1931, were for a long time considered to be mainly of academic interest. This view changed when it was shown that a two-photon absorption process could, because of a quadratic dependence of excitation on intensity, produce a spatially confined excitation useful for three-dimensional data storage and imaging. Two-photon absorption has received considerable attention recently because of the development of highly efficient two-photon-sensitive materials, leading to numerous technological applications. These successes have created interest in exploring applications based on three-photon excitations. For a three-photon process, a longer excitation wavelength such as those common in optical communications can be used. Also, the cubic dependence of the three-photon process on the input light intensity provides a stronger spatial confinement, so that a higher contrast in imaging can be obtained. Here we report the observation of a highly directional and up-converted stimulated emission as an amplified spontaneous emission, produced in an organic chromophore solution by a strong simultaneous three-photon absorption at 1.3 microm. This achievement suggests opportunities for a three-photon process in frequency-upconversion lasing, short-pulse optical communications, and the emerging field of biophotonics.

Coloring Agents↗

Near-field optics and quantum optics: an assignation arranged by four kinds of photons.

In the process of emergence a photon emitted from an atom (or a molecule) is usually no better localized in space than to the near-field zone of the source. Near-field optics therefore is of central importance for understanding fundamental statistical aspects related to single-photon tunnelling, the space-time description of photon dynamics, and the photon position-operator problem. In the present work an attempt is made to study the microscopic near-field optical interaction from a quantum statistical point of view. In near-field quantum electrodynamics (QED) scalar and longitudinal photons always are involved and this makes the covariant formulation of QED attractive also in the low-energy regime. We show that the Lorenz gauge condition on the global state vector relates to the near-field electrodynamics of the d-photons. The gauge photon is shown to be of no importance in near-field interactions. To understand the role of the lack of photon localizability we finally study near-field quantum optical correlations in a new so-called propagator gauge.

Lasers↗

Efficient simulation of SPECT down-scatter including photon interactions with crystal and lead.

A major image degrading factor in simultaneous Dual Isotope (DI) SPECT or simultaneous Emission-Transmission (ECT-TCT) imaging, is the detection of photons emitted by the higher energy isotope in the energy window used for imaging the lower energy isotope. In Tc-99m/Tl-201 DI-SPECT typically tens of percents of the total detected down-scatter is caused by lead x rays. In Tc-99m/Gd-153 ECT-TCT, a comparable fraction of the down-scatter originates from Tc-99m photons which only partly deposit their energy in the detector crystal (i.e., due to crystal interactions). Efficient simulation methods which model down-scatter can be used to optimize DI-SPECT or ECT-TCT imaging acquisition or reconstruction protocols. In this paper we adapt a previously proposed efficient down-scatter simulation method, to include the interactions of photons with the detector crystal and collimator lead. To this end, point spread function tables including crystal and lead interactions are precalculated. Subsequently, photons are traced through the patient body until their last scatter position, and the precalculated responses are used to project the photons onto the detector plane, while photon attenuation in the patient is taken into account. The approach is evaluated by comparing simulated Tc-99m down-scatter projections with measured projections. Incorporation of photon interaction with crystal and lead leads to significantly improved accuracy of the shape of down-scatter responses, while differences in total counts between simulated and measured projections typically decrease from tens of percents to a couple of percents. Calculating 60 down-scatter projections of an extended distribution on a 64 x 64 x 64 grid takes about three minutes on a PC with two 1.2 GHz processors. We conclude that accurate and efficient simulation of down-scatter is now possible including the major effects of the nonuniform mass density of the patient as well as photon interactions with the crystal and collimator lead.

Biophysical Phenomena↗

Antecedents of two-photon excitation laser scanning microscopy.

In 1931, Maria Göppert-Mayer published her doctoral dissertation on the theory of two-photon quantum transitions (two-photon absorption and emission) in atoms. This report describes and analyzes the theoretical and experimental work on nonlinear optics, in particular two-photon excitation processes, that occurred between 1931 and the experimental implementation of two-photon excitation microscopy by the group of Webb in 1990. In addition to Maria Göppert-Mayer's theoretical work, the invention of the laser has a key role in the development of two-photon microscopy. Nonlinear effects were previously observed in different frequency domains (low-frequency electric and magnetic fields and magnetization), but the high electric field strength afforded by lasers was necessary to demonstrate many nonlinear effects in the optical frequency range. In 1978, the first high-resolution nonlinear microscope with depth resolution was described by the Oxford group. Sheppard and Kompfner published a study in Applied Optics describing microscopic imaging based on second-harmonic generation. In their report, they further proposed that other nonlinear optical effects, such as two-photon fluorescence, could also be applied. However, the developments in the field of nonlinear optical stalled due to a lack of a suitable laser source. This obstacle was removed with the advent of femtosecond lasers in the 1980s. In 1990, the seminal study of Denk, Strickler, and Webb on two-photon laser scanning fluorescence microscopy was published in Science. Their paper clearly demonstrated the capability of two-photon excitation microscopy for biology, and it served to convince a wide audience of scientists of the potential capability of the technique.

History, 20th Century↗

Activity-dependent neural tissue oxidation emits intrinsic ultraweak photons.

Living organisms have been known to spontaneously emit ultraweak photons in vivo and in vitro. Origin of the photon emission remains unclear, especially in the nervous system. The spontaneous ultraweak photon emission was detected here from cultured rat cerebellar granule neurons using a photomultiplier tube which was highly sensitive to visible light. The photon emission was facilitated by the membrane depolarization of neurons by a high concentration of K+ and was attenuated by application of tetrodotoxin or removal of extracellular Ca2+, indicating the photon emission depending on the neuronal activity and likely on the cellular metabolism. Furthermore, almost all the photon emission was arrested by 2,4-dinitrophenylhydrazine, indicating that the photon emission would be derived from oxidized molecules. Detection of the spontaneous ultraweak photon emission will realize noninvasive and real-time monitoring of the redox state of neural tissue corresponding to the neuronal activity and metabolism.

Animals↗

Investigation of photon beam models in heterogeneous media of modern radiotherapy.

This study investigates the performance of photon beam models in dose calculations involving heterogeneous media in modern radiotherapy. Three dose calculation algorithms implemented in the CMS FOCUS treatment planning system have been assessed and validated using ionization chambers, thermoluminescent dosimeters (TLDs) and film. The algorithms include the multigrid superposition (MGS) algorithm, fast Fourier Transform Convolution (FFTC) algorithm and Clarkson algorithm. Heterogeneous phantoms used in the study consist of air cavities, lung analogue and an anthropomorphic phantom. Depth dose distributions along the central beam axis for 6 MV and 10 MV photon beams with field sizes of 5 cm x 5 cm and 10 cm x 10 cm were measured in the air cavity phantoms and lung analogue phantom. Point dose measurements were performed in the anthropomorphic phantom. Calculated results with three dose calculation algorithms were compared with measured results. In the air cavity phantoms, the maximum dose differences between the algorithms and the measurements were found at the distal surface of the air cavity with a 10 MV photon beam and a 5 cm x 5 cm field size. The differences were 3.8%. 24.9% and 27.7% for the MGS. FFTC and Clarkson algorithms. respectively. Experimental measurements of secondary electron build-up range beyond the air cavity showed an increase with decreasing field size, increasing energy and increasing air cavity thickness. The maximum dose differences in the lung analogue with 5 cm x 5 cm field size were found to be 0.3%. 4.9% and 6.9% for the MGS. FFTC and Clarkson algorithms with a 6 MV photon beam and 0.4%. 6.3% and 9.1% with a 10 MV photon beam, respectively. In the anthropomorphic phantom, the dose differences between calculations using the MGS algorithm and measurements with TLD rods were less than +/-4.5% for 6 MV and 10 MV photon beams with 10 cm x 10 cm field size and 6 MV photon beam with 5 cm x 5 cm field size, and within +/-7.5% for 10 MV with 5 cm x 5 cm field size, respectively. The FFTC and Clarkson algorithms overestimate doses at all dose points in the lung of the anthropomorphic phantom. In conclusion, the MGS is the most accurate dose calculation algorithm of investigated photon beam models. It is strongly recommended for implementation in modern radiotherapy with multiple small fields when heterogeneous media are in the treatment fields.

Algorithms↗

Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy.

PURPOSE: To assess the potential benefit of proton-beam therapy in comparison to 3-D conformal photon therapy and photon- based intensity-modulated radiotherapy (IMRT) in prostate carcinoma for various stages of disease. MATERIAL AND METHODS: In five patients a 3-D conformal proton-based (two lateral beams) irradiation technique was compared with 3-D conformal photon-beam radiotherapy (four-field box) and IMRT (seven beams). For each patient different target volumes (CTVs) were defined according to early, intermediate and advanced stages of disease: CTV I consisted of the prostate gland, CTV II encompassed prostate and basis of seminal vesicles, and CTV III the prostate and seminal vesicles. Corresponding planning target volumes PTV I-III were defined by uniformly adding a margin of 5 mm to CTV I-III. Dose-volume histograms (DVHs) were analyzed for the different PTVs and various organs at risk (OARs), i.e., rectal wall, bladder, both femoral heads. In addition, maximum and mean doses were derived for the various structures and irradiated non-target tissue volumes were compared for PTV I-III and the different irradiation techniques. Finally, dose conformity and target dose homogeneity were assessed. RESULTS: With photon- and proton-based radiotherapy techniques similar dose distributions were determined for PTV I-III: mean and maximum PTV dose values were between 99-104% and 102-107% of the normalized total doses (70 Gy), respectively. Conformity indices varied from 1.4 to 1.5 for the photon techniques, whereas for proton-beam radiotherapy values ranged from 1.1 to 1.4. Both the 3-D conformal and the IMRT photon treatment technique resulted in increased mean doses (approximately 40-80%) for OARs when compared to protons. With both photon techniques non-target tissue volumes were irradiated to higher doses (mean dose difference > or = 70%) compared to proton-beam radiotherapy. Differences occurred mainly at the low and medium dose levels, whereas in high dose levels similar values were obtained. In comparison to conformal 3-D treatments IMRT reduced doses to OARs in the medium dose range, especially for the rectal wall. CONCLUSION: IMRT enabled dose reductions to OARs in the medium dose range compared to 3-D conformal radiotherapy. A rather simple two-field proton-based treatment technique further reduced doses to OARs compared to photon-beam radiotherapy. The advantageous dose distribution of proton-beam therapy for prostate cancer may result in reduced side effects, which needs to be confirmed in clinical studies.

Femur↗

Dose measurements in the build-up region for the photon beams from Clinac-1800 dual energy medical linear accelerator.

AIM: Since the skin dose becomes the limiting factor while deciding the tumorcidal dose, the detailed analysis of dose distribution in the build-up region is necessary for high-energy photon beams. In this study the beam characteristics affecting the build-up and skin dose for 6- and 18-MV photons are analyzed. MATERIALS AND METHODS: Measurements were made with 6- and 18-MV photons using a PTW parallel-plate ionization chamber (B 23344-036) and a RDM-1F electrometer. Build-up ionization measurements were made with the chamber fitted into a 25 x 25 x 25 cm polystyrene phantom with a fixed SSD of 100 cm. The entrance and build-up dose measurements were made with a polycarbonate and a mesh type metallic shielding tray and a 45 degrees wedge. Exit dose measurements were carried out for the graphite patient supporting assembly table top, 1.0 cm thick piece of wood and the 1.0 cm thick patient supporting perspex base frame for head and neck treatments. RESULTS: It was observed that the dmax decreased slightly with field size as with other accelerators. For both photon energies the surface dose was observed to increase with increase in field size. It was also noticed that the dose in the build-up region increases slightly when the polycarbonate secondary blocking tray is introduced with the increase in surface dose. The data show that the tray perturbation factor (TPF) at surface decreases steadily with tray-surface distance for both photon beams for all field sizes. It was noted that the TPF was more when the polycarbonate tray was introduced at shorter tray-surface distances for both energies. At tray-surface distances above 60 cm the TPF almost remained close to unity for 6-MV photons for all field sizes, whereas the continuous decrease in TPF could be noted for 18-MV photon beams even after the TPF reached unity. CONCLUSION: The increase in surface dose with field size for both photon energies is due to the electron scattering from the intervening materials. The use of wedge filters absorbs low-energy scattered electrons significantly and hence, the relative surface dose (RSD) is always less than unity. The increase in dose enhancement percentage with graphite compared to perspex supporting assembly indicates that the electron backscatter is proportional to the atomic number of the medium.

Electrons↗

The efficiency of two-photon photolysis of a "caged" fluorophore, o-1-(2-nitrophenyl)ethylpyranine, in relation to photodamage of synaptic terminals.

Localized photolysis of caged neurotransmitters with the two-photon effect for investigations at synaptic preparations was evaluated by determining the toxicity to synaptic transmission of pulsed near-IR laser light focused into the terminals of the snake neuromuscular junction, and measuring the extent of photolysis of a conventional caging group with similar irradiation in microcuvette experiments. Photodamage was seen in synaptic terminals as a large, irreversible increase of spontaneous synaptic activity with laser flashes of 5 ms at 1 Hz at average powers > 5 mW and was due to multiphoton absorption. Localized photolysis due to two-photon absorption was investigated for a representative caged fluorophore, the 1-(2-nitrophenyl)ethyl ether of pyranine (NPE-HPTS). Irradiation of NPE-HPTS at 5 mW with the same optical arrangement produced very low rates of photolysis. NPE-HPTS photolysis mechanisms were investigated at high laser powers by measuring (1) the kinetics of two-photon fluorescence generated by two-photon photolysis in the focal volume and (2) the rates of HPTS accumulation inside closed 2-10 microm radius vesicles, measured with one-photon excitation during two-photon photolysis by repetitive 10 micros laser exposures. The two-photon crosssection of NPE-HPTS photolysis calculated from the rates is 0.02-0.04 GM (10(-50) cm4 x s/photon) and limits the efficiency of photolysis at 5 mW. With free diffusional exchange, 50% steady-state cage depletion in the focal volume was estimated to occur only at high laser powers of ca. 72 mW, masked in experiments by multiphoton bleaching. Based on these results, the two-photon photolysis cross-section needed for 50% steady-state photolysis of a caged neurotransmitter at 5 mW is calculated as 31 GM, much higher than in existing caged compounds.

Animals↗

Photon versus fast neutron external beam radiotherapy in the treatment of locally advanced prostate cancer: results of a randomized prospective trial.

PURPOSE: To evaluate the effectiveness of fast neutron radiation therapy in treatment of locally advanced carcinomas of the prostate. METHODS AND MATERIALS: From April 1986 to October 1990, 178 patients were entered on a prospective, multi-institutional randomized study of the NCI-sponsored Neutron Therapy Collaborative Working Group. This trial compared external beam photon irradiation (7000-7020 cGy) with external beam neutron irradiation (2040 ncGy) for patients with high-grade T2 or T3-4, N0-1, M0 adenocarcinomas of the prostate. Eighty-nine patients were randomized to each treatment. Six patients were subsequently judged to be ineligible, leaving 85 photon and 87 neutron randomized patients eligible for analysis. RESULTS: With a follow-up time ranging from 40 to 86 months (68 months median follow-up) the 5-year actuarial clinical local-regional failure rate for patients treated with neutrons was 11%, vs. 32% for photons (p < 0.01). Incorporating the results of routine posttreatment prostate biopsies, the resulting "histological" local-regional tumor failure rates were 13% for neutrons vs. 32% for photons (p = 0.01). To date, actuarial survival and cause-specific survival rates are statistically indistinguishable for the two patient cohorts, with 32% of the neutron-treated patient deaths and 41% of the photon-treated patient deaths caused by prostate cancer (p = n.s.). Prostate specific antigen (PSA) values were elevated in 17% of neutron-treated patients and 45% of photon-treated patients at 5 years (p < 0.001). Severe late complications of treatment were higher for the neutron-treated patients (11% vs. 3%), and were inversely correlated with the degree of neutron beam shaping available at the participating institutions. Neutron treatment delivery utilizing a fully rotational gantry and multileaf collimator did not result in an increase in severe late effects when compared to photon treatment. CONCLUSION: High energy fast neutron radiotherapy is safe and effective when adequate beam delivery systems and collimation are available, and it is significantly superior to external beam photon radiotherapy in the local-regional treatment of large prostate tumors.

Adenocarcinoma↗

Time-resolved fluorescence spectroscopy and imaging of DNA labeled with DAPI and Hoechst 33342 using three-photon excitation.

We examined the fluorescence spectral properties of the DNA stains DAPI (4',6-diamidino-2-phenylindole, hydrochloride) and Hoechst 33342 (bis-benzimide, or 2,5'-bi'1H-benzimidazole2'-(4-ethoxyphenyl)-5-(4-methyl-1-piperazi nyl)) with two-photon (2h nu) and three-photon (3h nu) excitation using femtosecond pulses from a Ti:sapphire laser from 830 to 885 nm. The mode of excitation of DAPI bound to DNA changed from two-photon at 830 nm to three-photon at 885 nm. In contrast, Hoechst 33342 displayed only two-photon excitation from 830 to 885 nm. DAPI-DNA displayed the same emission spectra and decay times for 2h nu and 3h nu excitation. Hoechst 33342-DNA displayed the same intensity decay for excitation at 830 and 885 nm. Both probes displayed higher anisotropies for multiphoton excitation as compared to one-photon excitation with ultraviolet wavelengths, and DAPI-DNA displays a higher anisotropy for 3h nu at 885 nm than for 2h nu at 830 nm. We used 970-nm excitation of DAPI-stained chromosomes to obtain the first three-dimensional images with three-photon excitation. Three-photon excitation of DAPI-stained chromosomes at 970 nm was demonstrated by the power dependence in the fluorescence microscope.

Benzimidazoles↗

A treatment planning comparison of 3D conformal therapy, intensity modulated photon therapy and proton therapy for treatment of advanced head and neck tumours.

BACKGROUND AND PURPOSE: In this work, the potential benefits and limitations of different treatment techniques, based on mixed photon-electron beams, 3D conformal therapy, intensity modulated photons (IM) and protons (passively scattered and spot scanned), have been assessed using comparative treatment planning methods in a cohort of patients presenting with advanced head and neck tumours. MATERIAL AND METHODS: Plans for five patients were computed for all modalities using CT scans to delineate target volume (PTV) and organs at risk (OAR) and to predict dose distributions. The prescribed dose to the PTV was 54 Gy, whilst the spinal cord was constrained to a maximum dose of 40.5 Gy for all techniques. Dose volume histograms were used for physical and biological evaluation, which included equivalent uniform dose (EUD) calculations. RESULTS: Excluding the mixed photon-electron technique, PTV coverage was within the defined limits for all techniques, with protons providing significantly improved dose homogeneity, resulting in correspondingly higher EUD results. For the spinal cord, protons also provided the best sparing with maximum doses as low as 17 Gy. Whilst the IM plans were demonstrated to be significantly superior to non-modulated photon plans, they were found to be inferior to protons for both criteria. A similar result was found for the parotid glands. Although they are partially included in the treated volume there is a clear indication that protons, and to a lesser extent IM photons, could play an important role in preserving organ functionality with a consequent improvement of the patient's quality of life. CONCLUSIONS: For advanced head and neck tumours, we have demonstrated that the use of IM photons or protons both have the potential to reduce the possibility of spinal cord toxicity. In addition, a substantial reduction of dose to the parotid glands through the use of protons enhances the interest for such a treatment modality in cases of advanced head and neck tumours. However, in terms of target coverage, the use of 3D conformal therapy, although somewhat inferior in quality to protons or IM photons, has been shown to be a reasonable alternative to the more advanced techniques. In contrast, the conventional technique of mixed photon and electron fields has been shown to be inferior to all other techniques for both target coverage and OAR involvement.

Carcinoma, Squamous Cell↗

A new analysis method of single molecule fluorescence using series of photon arrival times: theory and experiment.

Up to now, single molecule fluorescence experiments were performed by dividing the time into a set of intervals and to observe the number of fluorescence photons arriving in each interval. It is obvious that the detected photons carry less information than the arrival times of the photons themselves. From the arrival times, one can still calculate the number of photons in any user-defined interval; whereas, when only the number of photons in an interval are recorded, information about their positions in time is lost. Therefore, we present a new analysis method of single molecule fluorescence data based on the positions in time of the detected fluorescence photons. We derive mathematically different statistical characteristics describing the single molecule fluorescence experiment assuming an immobilized molecule. The theory of point processes using the generating functionals formalism is ideally suited for a consistent description, linking the statistical characteristics of the excitation and detected photons to the statistical characteristics of the single motionless molecule. We then use computer-generated data sets mimicking the single molecule fluorescence experiment to explore the parametric estimation of mono- and bi-exponential single molecule impulse response functions (SMIRFs) via the following statistical characteristics: the probability density distributions (pdd) of the single and first photocount time positions in a user-defined detection interval, the probability distribution of the number of photocounts per user-defined detection interval, the time correlation function and the pdd of the time interval between two consecutive photocounts. It is shown that all of the above characteristics ensure a satisfactory recovery of the decay time of mono-exponential SMIRFs for a broad range of excitation intensities and widths of user-defined detection intervals. For bi-exponential SMIRFs, the selection of the experimental conditions is more critical and dependent on the detection procedure. At lower excitation intensities it is advantageous to use the pdds of the single and first photocount time occurrences in the user-defined detection interval. To show the practical usefulness of the new analysis method, series of photon arrival times from immobilized single molecules of DiI and rhodamine 6G were analyzed to estimate triplet lifetimes and intersystem crossing yields.

Biophysical Phenomena↗

Aspects on the optimal photon beam energy for radiation therapy.

The selection of optimal photon beam energy is investigated both for realistic clinical bremsstrahlung beams and for monoenergetic photon beams. The photon energies covered in this investigation range from 60Co to bremsstrahlung and monoenergetic beams with maximum energies up to 50 MeV. One head and neck tumor and an advanced cervix tumor are investigated and the influence of beam direction is considered. It is shown that the use of optimized intensity modulated photon beams significantly reduces the need of beam energy selection. The most suitable single accelerator potential will generally be in the range 6-15 MV for both superficially located and deep-seated targets, provided intensity-modulated dose delivery is employed. It is also shown that a narrow penumbra region of a photon beam ideally should contain low-energy photons (< or =4 MV), whereas the gross tumor volume, particularly when deep-seated targets are concerned, should be irradiated by high-energy photons. The regions where low photon energies are most beneficial are where organs at risk are laterally close to the target volume. The situation is completely changed when uniform or wedged beams are used. The selection of optimal beam energy then becomes a very important task in line with the experience from traditional treatment techniques. However, even with a large number of uniform beam portals, the treatment outcome is substantially lower than with a few optimized intensity-modulated beams.

Female↗

Photon scatter kernels for intensity modulating radiation therapy filters.

The most important beam property while optimizing photon therapy is the ability to modulate the intensity of the beam. The use of photon absorbers for intensity modulation of beam profiles requires special attention to be paid to the alteration of beam properties due to scatter and spectral changes, in addition to the desired intensity modulation. In this study the influence of photon scatter in high-density filters irradiated with very narrow photon pencil beams was investigated. A simple analytical relation is developed to quantify the contribution by scattered photons. A scatter kernel was derived by convolving the first Compton scatter distribution with an approximate expression for the second-order scattered photons. The calculations were validated experimentally with film dosimetry and also by using Monte Carlo simulations. Results show that the difference in photon scatter estimation by different methods is relatively small when higher order scattering is accounted for. At 6 MV x-rays the agreement is slightly better than that for 18 MV x-rays results. The simple relation presented in this paper can be used to account for the scattered photon contribution in filter optimization codes to deliver biologically or physically optimized intensity modulated treatments.

Models, Statistical↗