Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PLETHYSMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Detection of deep venous thrombosis by impedance plethysmography.

Ninety-eight limbs in sixty-seven patients supected of having lower extremity deep venous thrombosis were evaluated by physical examination, venous impedance plethysmography (IPG), and venography. Diagnosis based on physical signs commonly associated with deep venous thrombosis was false-positive in 43 to 66 per cent and false-negative in 26 to 73 per cent when compared with evidence obtained by venography. The overall accuracy of IPG was 94 per cent, with false-positive results occurring in 10 per cent and false-negative results in 4 per cent. IPG is sufficiently accurate to be considered a reliable screening test for lower extremity deep venous thrombosis.

Adolescent↗

Accuracy of strain-gauge plethysmography as a diagnostic test in clinically suspected deep venous thrombosis.

Strain-gauge plethysmography (SGP) is currently employed in the diagnosis of deep venous thrombosis (DVT), but its accuracy has not been adequately tested. In this study we evaluated SGP against venography in 209 consecutive patients referred to us because of clinically suspected DVT of lower limbs. Venography was performed bilaterally if symptoms or signs suggesting DVT were present in both limbs. It was always performed after SGP and independently assessed. A total of 269 limbs could be evaluated with both SGP and venography, which disclosed DVT in 128 limbs of 110 patients. There were 109 proximal and 19 distal DVT. Out of the 128 limbs with DVT, SGP was positive in 114 (sensitivity = 89%) using Maximal Venous Outflow (MVO) as the diagnostic parameter, and positive in 116 (sensitivity = 91%) using an index obtained multiplying MVO for Venous Capacitance (VC). Out of the 141 venographically negative limbs, there were 6 false positive results using MVO and 9 using MVO X VC (specificity = 96% and 94% respectively). SGP sensitivity in acute proximal venous thrombosis was 97%, while it was about 60% in distal DVT. Most false positive results occurred in patients with edema of cardiac origin. SGP appears to be a useful diagnostic test in suspected DVT of lower limbs, particularly when both MVO and the index MVO X VC are used.

Adolescent↗

The value of adding thermographic leg scanning to impedance plethysmography in the detection of deep vein thrombosis.

The clinical value of adding thermographic leg scanning to impedance plethysmography was evaluated and compared in 52 patients with clinically suspected deep venous thrombosis. Both tests were performed on the day of referral and phlebography within 72 hours. The sensitivity of thermography was 83%, the specificity 41% and the accuracy 61%. In comparison IPG had a sensitivity of 83%, a specificity of 96% and an accuracy of 90% The combination of thermography and IPG showed a sensitivity of 92%, a specificity of 41% and an accuracy of 65%. It is concluded that the addition of thermography to IPG is of no clinical value.

Evaluation Studies as Topic↗

Measurement of pulsatile limb and finger blood flow by electrical impedance plethysmography: criteria for the diagnosis of abnormal flow.

The range of pulsatile arm and finger blood flow, measured by electrical impedance plethysmography, has been investigated in a hospital ward. The range of absolute blood flows, in ml min-1, was found to be too wide to be used as a standard for identifying single blood flow readings as being abnormal. A blood flow ratio was calculated by dividing the blood flow in the right forearm or middle finger by the blood flow in the left forearm or middle finger. This ratio was found to have a clearly defined range. A blood flow in a unilaterally injured or otherwise abnormal arm or finger was considered to be significantly altered if the blood flow ratio fell outside the previously defined normal range. The diagnosis of significantly altered arm and finger blood flow from abnormalities in the blood flow ratio was tested in a series of experiments, in which artificial changes in upper limb flow were created by high elevation of the right hand. The ratio was measured in 11 patients with unilateral upper limb injuries and in 3 patients who required an urgent assessment of the upper limb circulation. Abnormalities in the ratio were identified in 12 out of 18 subjects after high elevation of the hand and in 8 out of the 14 patients.

Arm↗

Venous occlusion plethysmography in patients with cold related symptoms after digital salvage procedures.

Fourteen patients who had undergone microsurgical salvage of one or more digits were interviewed and examined. An assessment of sensitivity to cold is defined as cold intolerance and correlated with nerve function and arterial inflow measured by venous occlusion plethysmography. No relationship between arterial inflow and cold intolerance nor nerve function was found. There was, however a tendency for worsening cold intolerance to be associated with poorer nerve function. Half the salvaged digits had arterial inflow greater than the contralateral control digit.

Adolescent↗

Analysis of vasospasm in hand arteries by in vitro pharmacology, hand angiography and finger plethysmography.

1. The distribution of sympathetic nerves in hand arteries and veins from 18 normal subjects was studied by microscopy according to the Falck-Hillarp histofluorescence method for the cellular visualization of cathecholamines and by quantitative analysis of noradrenaline with a radioenzymatic method. Segments of hand arteries and veins were tested in vitro for the vasomotor effect of sympathomimetic agonists. 2. Fluorescence microscopy revealed a plexus of noradrenaline-containing nerve fibres surrounding both arteries and veins. The concentration of noradrenaline in the walls were 4.5-4.7 ng/mg protein. The relative agonist potency was characteristic for alpha-receptors. Phentolamine produced parallel shift of the dose-response curves both for arteries and veins. 3. Finger plethysmography with local cold provocation down to 10 degrees C was performed in the patients with traumatic vasospastic disease before and after inhibition of the sympathetic nervous system by body warming and orally administered alcohol. Four patients had undisturbed circulation, as revealed by the ratio between the systolic blood pressure in the arm and in the finger in conjunction with cold provocation tests. 13 patients had vasospasm of varying degrees, and 3 patients suffered from organic stenosis. 4. Hand angiography was performed before and after local cold provocation. The patients with organic stenosis did not show vasodilatation after 4-6 mg phentolamine injection. Patients with true vasospasm responded, in addition, with efficient vasodilatation 15 min after reserpine injection, which also abolished the cold-induced vasospasm.

Angiography↗

Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients.

BACKGROUND: To avoid ischemic hand complications, the percutaneous transradial approach is only performed in patients with patent hand collateral arteries, which is usually evaluated with the modified Allen's test (MAT). This qualitative test measures the time needed for maximal palmar blush after release of the ulnar artery compression with occlusive pressure of the radial artery. The objectives were to evaluate the patency of the hand collateral arteries and to compare MAT with combined plethysmography (PL) and pulse oximetry (OX) tests before the percutaneous transradial approach. METHODS: Patients referred to the catheterization laboratory were prospectively examined with MAT, PL, and OX tests. PL readings during radial artery compression were divided into 4 types: A, no damping; B, slight damping of pulse tracing; C, loss followed by recovery; or D, no recovery of pulse tracing within 2 minutes. OX results were either positive or negative. Results of both tests were compared in 1010 consecutive patients. RESULTS: MAT results < or =9 seconds on either hand were seen in 93.7% of patients. PL and OX types A, B, or C on either hand were seen in 98.5% of patients. On the basis of the MAT < or =9 seconds criteria, 6.3% of patients were excluded from the transradial approach, whereas with PL and OX types A, B, and C, only 1.5% of patients were excluded. There was more exclusion in men and with increasing age by using both methods. CONCLUSIONS: In the evaluation of hand collaterals, PL and OX were found to be more sensitive than MAT. When applied to transradial approach screening, only 1.5% of patients were not suitable candidates for the transradial approach.

Adult↗

A comparison of hydrostatic weighing and air displacement plethysmography in adults with spinal cord injury.

OBJECTIVES: To compare (1) total body volume (V(b)) and density (D(b)) measurements obtained by hydrostatic weighing (HW) and air displacement plethysmography (ADP) in adults with spinal cord injury (SCI); (2) measured and predicted thoracic gas volume (V(TG)); and (3) differences in percentage of fat measurements using ADP-obtained D(b) and HW-obtained D(b) measures that were interchanged in a 4-compartment body composition model (4-comp %fat). DESIGN: Twenty adults with SCI underwent ADP and V(TG), and HW testing. In a subgroup (n=13) of subjects, 4-comp %fat procedures were computed. SETTING: Research laboratories in a university setting. PARTICIPANTS: Twenty adults with SCI below the T3 vertebrae and motor complete paraplegia. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Statistical analyses, including determination of group mean differences, shared variance, total error, and 95% confidence intervals. RESULTS: The 2 methods yielded small yet significantly different V(b) and D(b). The groups' mean V(TG) did not differ significantly, but the large relative differences indicated an unacceptable amount of individual error. When the 4-comp %fat measurements were compared, there was a trend toward significant differences (P=.08). CONCLUSIONS: ADP is a valid alternative method of determining the V(b) and D(b) in adults with SCI; however, the predicted V(TG) should be used with caution.

Adolescent↗

Modified thoracic impedance plethysmography to monitor sleep apnea syndromes.

BACKGROUND AND PURPOSE: In order to identify sleep disorders by thoracic impedance plethysmography (TIP), we propose several new techniques: the application of an adaptive filter, a scaled Fourier linear combiner (SFLC) to eliminate cardiac-derived fluctuation in the impedance waveform, and the use of heart rate variability (HRV) to ascertain whether the airflow is obstructed. PATIENTS AND METHODS: Laboratory simulation experiments on four healthy individuals and actual overnight measurements on five patients with sleep disorders were carried out. Amplified thoracic impedance change (DeltaZ), ECG, a phonocardiograph, a pneumotachograph and a standard polysomnograph were recorded. The SFLC was applied to DeltaZ to selectively extract the cardiac-synchronous component (DeltaZ(CSC)), and the remainder of the waveform (DeltaZ(REM)) was low-pass filtered to estimate the waveform driven by respiration. The HRV was divided into respiratory synchronous (HRV(R)) and low frequency (HRV(L)) components. RESULTS: The SFLC could drastically extract DeltaZ(CSC) from DeltaZ and thereby demonstrate a DeltaZ(REM) pattern quite similar to the flow-volume curve of the pneumotachograph. Central sleep apnea could be identified as the cessation of DeltaZ(REM) and concomitant attenuation of HRV(R). Obstructive sleep apnea could be identified as the maintenance of rhythmic but attenuated variations of DeltaZ(REM) accompanied by asynchronous fluctuation of HRV(R) against DeltaZ(REM). Central hypopnea could be identified as a normal but attenuated waveform in both DeltaZ(REM) and HRV(R). A large fluctuation in HRV(L) was observed during repetitive appearances of apnea/hypopnea in the nocturnal experiments. CONCLUSION: The modified TIP together with HRV provides a superior tool for accurate and convenient definition of sleep apnea syndromes.

Heart Rate↗

Whole body barometric plethysmography: a screening method to investigate airway reactivity and acute lung injuries in freely moving pigs.

The aim of this work was to investigate whether the Penh index, measured using whole body barometric plethysmography, can be used as a screening parameter to evaluate the airway reactivity and the intensity of the pulmonary response to endotoxins. Penh was firstly recorded in non-sedated freely moving piglets exposed (1) to a nebulized acetylcholine (Ach) pre-treated or not with clenbuterol, or (2) to endotoxin challenge. To measure Penh simultaneously with total pulmonary resistance (R(L)), dynamic compliance (C(dyn)) and intrapleural pressure changes (Max Delta Ppl), an oesophageal balloon catheter technique was used and the piglets were anaesthetised. The recordings were performed during (1) an intravenous metacholine (Mch) challenge and (2) in endotoxin-exposed animals. In freely moving animals, Ach induced a significant dose-dependent increase in Penh, which was significantly blocked by clenbuterol. Endotoxin instillation also resulted in a significant rise in Penh while the corresponding response measured under anaesthesia was significantly and positively correlated with R(L) and Max Delta Ppl. Similar results were obtained during Mch challenge but the Penh was negatively correlated with C(dyn). We conclude that Penh could be used in freely moving piglets as a screening index for airway reactivity and pulmonary functional changes in cholinergic and endotoxin challenges.

Airway Resistance↗

Evaluation of respiratory function by barometric whole-body plethysmography in healthy dogs.

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

Airway Resistance↗

Non-invasive assessment of growth, gender and time of day related changes of respiratory pattern in healthy cats by use of barometric whole body plethysmography.

The objective of this study was to establish a reference base for respiratory variables (respiratory rate [R(R)], inspiratory and expiratory time [T(i) and T(e)], peak inspiratory and expiratory pseudoflow [PIF and PEF], tidal volume [V(T)], minute ventilation [V(E)] and enhanced pause [Penh]) of healthy cats by use of barometric whole body plethysmography (BWBP). Eighteen healthy European cats (10 male, 8 female) were studied from the age of 3 to 13 months in order to assess growth- and gender-related changes of BWBP variables. Chest radiographs and bronchoalveolar lavage cytology were performed to confirm pulmonary health status. Diurnal changes were investigated every 2 h over a period of 24 h when the cats were adult. V(T), V(E), PIF and PEF significantly increased during somatic growth and were higher in males than in females, whereas R(R), T(i), T(e), T(e)/T(i) ratio, PEF/PIF ratio and Penh remained unchanged and were not affected by gender. When measured over 24 h, Penh, T(e) and T(i) were significantly increased in the early morning hours (04:00 h), whereas R(R), PIF and PEF were decreased at that time. This study provides reference values of BWBP variables for healthy male and female cats and indicates when circadian changes might be observed.

Age Factors↗

Effects of cadmium chloride inhalation on airflow limitation to histamine, carbachol and adenosine 5'-monophosphate assessed by barometric whole body plethysmography in healthy dogs.

The effects of pharmacological bronchoprovocation on airflow patterns and surrogate respiratory parameters assessed by barometric whole body plethysmography (BWBP) were investigated in healthy dogs, previously exposed to cadmium chloride inhalation. BWBP-derived respiratory variables were calculated (1) at baseline and (2) following nebulisation of increasing concentrations of histamine, carbachol and adenosine 5'-monophosphate (AMP) until enhanced pause (PENH) increased to 300% of baseline (PCPENH300). Bronchoalveolar lavage fluid (BALF) cytology before (BCC) and after (ACC) cadmium chloride inhalation revealed cadmium-induced airway inflammation. Neutrophils increased from 6.7 +/- 7.3% (728 +/- 104/microL) BCC to 77.8 +/- 8.6% (3255 +/- 1407/microL) ACC. PCPENH300 for all three agonists significantly decreased ACC (means+/-SD) as follows: PCPENH300(histamine) 0.72 +/- 0.28 mg/mL BCC, and 0.35 +/- 0.31 mg/mL ACC (P<0.02); PCPENH300(carbachol) 0.34 +/- 0.16 mg/mL BCC, and 0.064 +/- 0.032 mg/mL ACC (P<0.02); PCPENH300(AMP) 1000 mg/mL BCC, and 415 +/- 398 mg/mL ACC (P<0.03). The only clinical sign shown was coughing. It was concluded that airway hyperresponsiveness after induced airway inflammation can be determined by BWBP in conscious small sized dogs. BWBP could be a suitable technique to study the respiratory effects of urban environmental pollution in pets.

Adenosine Monophosphate↗

Non-invasive assessment of airway responsiveness in healthy and allergen-sensitised cats by use of barometric whole body plethysmography.

This study aimed at determining whether airway responsiveness (AR) tests performed by use of barometric whole body plethysmography (BWBP) were repeatable in cats and to what extent AR was affected by the nebulization protocol used, the age of the animals, the inflammatory status of the airways and prior bronchodilator treatment. Repeatability of AR was tested on two occasions in 30 healthy cats. The concentration of carbachol inducing a 300% increase of the enhanced pause (Penh)--an estimator of airflow limitation--was calculated (C-Penh300) and did not differ significantly between the two tests (0.035+/-0.017% compared to 0.034+/-0.016%) and was significantly and positively correlated. The comparison between rapidly and slowly increasing carbachol concentrations was performed in ten healthy cats and showed a significantly lower C-Penh300 (%) when slowly increasing concentrations were used (0.037+/-0.013% compared to 0.039+/-0.015%, P<0.05). A significant age-related increase of C-Penh300 was evidenced by performing AR tests in 15 healthy cats at 12, 18, 24 and 30 months (12 months: 0.026+/-0.008%, 18 months: 0.031+/-0.009%, 24 months: 0.038+/-0.01%, 30 months: 0.043+/-0.014%, P<0.05). C-Penh300 significantly decreased in 12 Ascaris suum-sensitised cats after allergen exposure (0.026+/-0.016% compared to 0.033+/-0.016%, P<0.05) and was negatively correlated with the granulocyte percentage of bronchoalveolar lavage fluid (r=-0.36, P<0.01). Compared with a placebo inhalation, pre-treatment with inhaled salbutamol significantly increased C-Penh300 in four healthy cats (0.093+/-0.021% compared to 0.036+/-0.004%, P<0.05). This study provides evidence that AR determination by use of BWBP is promising as non-invasive indicator of lower airway inflammation or for monitoring response to bronchodilator treatment.

Albuterol↗

Physiologic similarities between extremities with varicose veins and with chronic venous insufficiency utilizing air plethysmography.

Air plethysmography (APG) was used to measure maximal venous outflow rate (MVO), a test for proximal venous obstruction; venous volume; venous filling index, an estimate of valvular incompetence; ejection fraction (EF), a test of calf-muscle pump efficiency; and residual volume fraction (RVF), an estimate of ambulatory venous pressure. MVO was lower in patients with chronic venous insufficiency (CVI) than in those with varicose veins (VV), but the difference was small (p = 0.06). RVF was significantly greater in extremities with CVI when compared with those with VV (p less than 0.01). However, the degree of abnormality in venous volume, venous filling index, and EF was similar in CVI and VV extremities. In summary, although RVF tends to be higher in extremities with CVI when compared with those with VV, there is tremendous overlap between VV and CVI for each of the hemodynamic variables measured by APG. Therefore, the pathophysiology of CVI is likely to involve not only hemodynamic abnormalities but also other factors that have not yet been clearly identified.

Adult↗

Impedance plethysmography as a screening procedure for asymptomatic deep venous thrombosis in a rehabilitation hospital.

OBJECTIVE: Patients admitted for an inpatient rehabilitation treatment program almost uniformly have an elevated risk of deep venous thrombosis (DVT) and pulmonary embolism (PE). We assessed the value of impedance plethysmography (IPG) as a screening procedure for asymptomatic deep venous thrombosis in a series of patients admitted to our institution. DESIGN: Using a prospective observational study design, consecutive admissions to our facility for a period of almost one year were subjected to IPG within several days of admission. SETTING: The study site was a 60-bed hospital-based rehabilitation center. PATIENTS: Four hundred eighty-three consecutive patients were studied prospectively within several days of admission. Diagnoses included a variety of neurological disorders that resulted in significant weakness, intracranial surgery, orthopedic surgical procedures and fractures, joint replacements, and nonorthopedic postsurgical deconditioning. Three hundred eighteen patients were available for three-month follow-up. INTERVENTIONS: IPG was successfully completed in 301 patients. If IPG was positive, DVT was further assessed by duplex ultrasound (DU). When IPG and DU confirmed the presence of a DVT, administration of heparin and Coumadin was begun. MAIN OUTCOME MEASURES: Thirteen of 416 attempted IPG studies were positive for DVT, whereas DU confirmed the diagnosis in only 3 patients. RESULTS: Follow-up found that six patients developed DVT or PE before discharge from our institution; five patients developed DVT or PE after discharge. CONCLUSIONS: IPG has a poor yield as a screening tool for asymptomatic DVT on admission to an inpatient rehabilitation facility. The sensitivity and positive predictive value of IPG was too low to advocate its routine use in this setting.

Anticoagulants↗

A randomized management study of impedance plethysmography vs. contrast venography in patients with a first episode of clinically suspected deep vein thrombosis.

OBJECTIVES: In this randomized management study, we examined the safety of withholding anticoagulation on the basis of negative impedance plethysmography (IPG) compared to negative contrast venography (CV) in symptomatic patients with a first episode of clinically suspected deep vein thrombosis (DVT), and we determined the impact of the limitations of IPG or CV on their clinical utility. METHODS: Patients at a university teaching hospital presenting with a first episode of clinically suspected DVT were randomized to one of two management strategies at study entry: (1) IPG: if positive, confirmatory CV was performed. If CV was positive, anticoagulants were administered, if CV was negative, anticoagulants were held. If negative, IPG was repeated serially and if it remained negative, anticoagulants were held (n = 165). (2) CV: if positive, anticoagulants were administered, if negative, anticoagulants were held (n = 159). The negative predictive value (NPV) of IPG and CV, positive predictive value (PPV) of IPG, and the failure rate of each strategy were assessed. RESULTS: Among IPG patients, 28 of 37 with positive IPG initially or during serial testing and evaluable CV had confirmed DVT (PPV 76%; 95% confidence interval, CI [62%, 90%]). DVT was diagnosed during serial testing in 2.1% of patients with initially negative IPG who completed testing. The NPV overall of negative IPG was 98.3%. During follow-up, two patients in the IPG group (1.2%) and two patients in the CV group (1.3%) developed venous thromboembolism (VTE). Death during follow-up occurred in 11% of IPG patients compared to 6% of CV patients (P =.13) The investigation strategy failed in 25% of IPG patients and in 14% of CV patients. CONCLUSIONS: Our findings demonstrate that the two diagnostic strategies we studied are equivalent methods for ruling out DVT in patients with a first episode of suspected DVT. The PPV of IPG was too low to permit its use alone as a test to rule in DVT. Both strategies had surprisingly high failure rates.

Adult↗

Penile plethysmography useful in diagnosis of vasculogenic impotence.

Pulse-volume recordings were obtained in 40 normal subjects and 62 patients with history of impotence. In office practice, this study proved to be valuable for estimating penile perfusion. Penile plethysmography is a unique and adaptable screening method for penile blood flow. It measures the contributions of all vessels at the root of the penis. Pulse-volume recordings also were found to correlate with the severity of pelvic angiographic patterns of occlusive disease. Further investigation is necessary to determine the precision with which the method can detect penile blood flow in patients with early vascular compromise.

Blood Volume↗