Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PERICARDIUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Glutaraldehyde-fixed heterologous pericardium for vena cava grafting following hepatectomy.

BACKGROUND/AIMS: Glutaraldehyde-fixed heterologous pericardium has been widely used for grafts in cardiac surgery. We applied it for inferior vena cava (IVC) patch grafting following combined resection of the liver and the IVC. METHODOLOGY: IVC grafting using a glutaraldehyde-fixed horse pericardium following combined resection of the liver and the IVC was performed in 2 patients--one with hepatocellular carcinoma and the other with hepatic metastasis following rectal cancer. The retrohepatic vena cava defect was closed with a 10 x 5 cm patch in one patient and a 7 x 4 cm patch in the other. RESULTS: Hepatic vascular exclusion was avoided in both patients. The IVC exclusion period was 40 min for the first patient and 25 min for the second. One patient required a veno-venous bypass with an active centrifugal pump of 153 min. There was no complication and no graft infection. The microscopic extension to the IVC was evident in one patient, and fibrous adhesive was evident in the IVC wall of the other. One patient died of hepatic failure 3 years and 6 months after surgery, and the other died of hepatic recurrence 7 months after surgery. Both grafts were patent, without calcification and stricture, until the patients' death. CONCLUSIONS: Glutaraldehyde-fixed heterologous pericardium is an option for IVC grafting.

Bioprosthesis↗

Reconstruction of the pericardial sac with glutaraldehyde-preserved bovine pericardium.

Complete closure of the pericardial sac after open-heart surgery is thought to be a help in avoiding some postoperative complications and in facilitating reoperation. Since 1977, sixty-six patients who were subjected to open-heart surgery had glutaraldehyde stabilized xenogeneic bovine pericardial patches inserted to achieve closure of their own pericardial sacs. There were no hemodynamic problems related to the implantation of these patches. All 60 surviving patients were clinically well during a follow-up of 145 patient-years. Reoperation was undertaken in three patients 2(1/2), 3, and 7 years after the initial operation. The presence of the pericardial patch greatly facilitated the reopening of the chest because it prevented the formation of adhesions between the patch and the epicardium. Histologically, the implanted pericardium consisted of laminae of collagen fibrils containing evenly dispersed fibrocyte nuclei and parallel runs of fairly wide, separated elastic fibrils. There was no evidence of immune reaction. On the basis of our findings that there was no host reaction or complications after its use, glutaraldehyde stabilized xenogeneic bovine pericardium appears to be the material of choice for patch closure of the pericardium when primary closure alone is not feasible.

Journal Article↗

Bovine pericardium vs dacron for patch angioplasty after carotid endarterectomy: a prospective randomized study.

HYPOTHESIS: Bovine pericardium (BP) demonstrates improved intraoperative hemostasis and equivalent perioperative morbidity compared with Dacron when used as patch material for angioplasty following carotid endarterectomy. OBJECTIVE: To prospectively compare BP and Dacron patch angioplasty after carotid endarterectomy in a randomized fashion. METHODS: Ninety-five consecutive primary carotid endarterectomies were performed in a prospective randomized fashion in 92 patients. Fifty-one procedures were performed using BP and 44 using Dacron. Intraoperative suture line bleeding was subjectively evaluated by observing bleeding at 3 and 4 minutes following carotid cross-clamp removal and then objectively weighing the sponge used to tamponade bleeding during these time intervals. Perioperative morbidity, including cervical wound hematoma, transient ischemic attack, and stroke, and perioperative mortality were recorded. Statistical analysis was performed using paired t tests, chi(2) analysis, Fisher exact test, or multiple linear regression as appropriate. RESULTS: Suture line bleeding at 3 minutes was present in 7 (14%) of 51 patients in the BP group and 24 (55%) of 44 patients in the Dacron group (P<.001). Suture line bleeding evaluated at 4 minutes was present in 2 (4%) of 51 patients in the BP group and 13 (30%) of 44 patients in the Dacron group (P =.001). Net +/- SEM sponge weight (total intraoperative suture line bleeding) was 6.25 +/- 0.55 g in the BP group and 16.34 +/- 1.85 g in the Dacron group (P<.001). Total suture line bleeding was significantly affected by activated clotting time; however, multivariate analysis demonstrated that bleeding was significantly less with BP (P<.001) even after adjusting for differences in activated clotting time. CONCLUSIONS: Bovine pericardium demonstrated a statistically significant decrease in intraoperative suture line bleeding compared with Dacron. Handling characteristics were judged by the surgeons to be superior for BP. Therefore, we believe BP may be an alternative to Dacron when performing patch angioplasty of the carotid artery after endarterectomy.

Aged↗

Absent pericardium during coronary bypass.

The importance of recognizing congenitally absent left pericardium in the setting of acquired cardiovascular disease was recently appreciated during a case of coronary artery bypass grafting. An associated defect in the left hemidiaphragm and an abnormal location of the left phrenic nerve were found. Careful dissection of the phrenic nerve from the surface of the heart and closure of the diaphragmatic defect were necessary to avoid injury to the former and prevent hernia through the latter structure. Absent left pericardium discovered during cardiac surgery requires attention to the location of the left phrenic nerve and recognition of associated defects in the diaphragm.

Abnormalities, Multiple↗

Crosslinking characteristics and mechanical properties of a bovine pericardium fixed with a naturally occurring crosslinking agent.

Currently available crosslinking agents used in fixing bioprostheses are all highly (or relatively highly) cytotoxic, which may induce an adverse inflammatory reaction in vivo. It is therefore desirable to provide a crosslinking agent that is of low cytotoxicty and may form stable and biocompatible crosslinked products. To achieve this goal, a naturally occurring crosslinking agent-genipin-was used by our group to fix biological tissues. Genipin may be obtained from its parent compound, geniposide, which may be isolated from the fruits of Gardenia jasminoides Ellis. In our previous studies, it was found that the cytotoxicity of genipin is significantly lower than both glutaraldehyde and an epoxy compound. Also, it was shown that genipin can form stable and biocompatible crosslinked products. The present study further investigates the crosslinking characteristics and mechanical properties of a genipin-fixed bovine pericardium. Fresh and glutaraldehyde- and epoxy-fixed counterparts were used as controls. It was found that the denaturation temperatures of the glutaraldehyde- and genipin-fixed tissues were significantly greater than the epoxy-fixed tissue, although their fixation indices were comparable. The mechanical properties of fresh bovine pericardium are anisotropic. However, fixation tended to eliminate tissue anisotropy. The tendency in the elimination of tissue anisotropy for the genipin-fixed tissue was more remarkable than for the glutaraldehyde- and epoxy-fixed tissues. In addition, the genipin-fixed tissue had the greatest ultimate tensile strength and toughness among all the fixed tissues. Distinct patterns in rupture were observed in the study: The torn collagen fibers of the genipin- and glutaraldehyde-fixed tissues appeared to be bound together, while those of fresh and the epoxy-fixed tissues stayed loose. The results obtained in the study suggests that tissue fixation in glutaraldehyde, epoxy compound, and genipin may produce distinct crosslinking structures. The differences in crosslinking structure may affect the crosslinking characteristics and mechanical properties of the fixed tissues.

Animals↗

Pericardium of rodents: pores connect the pericardial and pleural cavities.

Numerous circular fenestrations or pores were present in the pericardium of the rat, golden hamster, and mouse. The pericardial pores were most numerous in the mouse. They were usually less than 50 micron in diameter and situated in a meshwork formed by thick, wavy bundles of collagen fibers and thin, straight, elastic fibers. These pores directly connected the pericardial and pleural cavities and indirectly connected the right and left pleural cavities; i.e., the pericardial cavity in the rodents is not independent from but intercommunicates with the adjacent pleural cavities. There were many aggregates of free cells or milky spots in the pericardium. They principally consisted of lymphocytes, macrophages, and mast cells and were directly exposed to the pericardial cavity.

Animals↗

Bilateral congenital diaphragmatic hernia with absent pleura and pericardium.

BACKGROUND: Bilateral congenital diaphragmatic hernia is a rare form of diaphragmatic hernia. Independently, pericardial defects are an extremely rare phenomenon. In the case presented, we provide the first complete description of an infant with bilateral congenital diaphragmatic hernia with complete agenesis of the pericardium and inferior parietal pleura. CASE: A male infant was born at 38 weeks of gestation with a prenatal diagnosis of left-sided congenital diaphragmatic hernia. After 1 week of aggressive management, the patient was taken to the operating room for repair. Intraoperatively, the patient was found to have absence of the diaphragm bilaterally, no pleura inferiorly, and no pericardium. A biological mesh was used to construct a diaphragm. At 6 months of age, the patient is growing normally, requiring only supplemental oxygen without pressure support. CONCLUSIONS: Embryologically, this anomaly represents complete lack of development of the pleurocardial folds, pleuroperitoneal folds, and transverse septum, which is previously unreported.

Abnormalities, Multiple↗

Partial congenital defect of the left pericardium: angiographic diagnosis and treatment by thoracoscopic pericardiectomy: case report.

Congenital defects of the pericardium are extremely rare and frequently difficult to diagnose. We present a diagnosis of partial congenital defect of the left pericardium based on a characteristic chest X-ray and left ventriculogram. Additionally, we report findings of a diastolic, migratory coronary stenosis on coronary arteriography which, to date, has not been reported. Confirmation of the diagnosis by mediastinoscopy was followed by thoracoscopic pericardiectomy.

Adult↗

Mechanical behavior of chemically treated ostrich pericardium subjected to uniaxial tensile testing: influence of the suture.

The mechanical behavior of sutured ostrich pericardium was studied by uniaxial tensile testing. One hundred forty-four tissue specimens were assessed: 96 sutured samples (48 in which a centrally located suture was placed at an angle of 90 degrees with respect to the longitudinal axis, whereas in the remaining 48, a centrally located suture was placed at a 45 degrees angle to the longitudinal axis, in sets of 12 samples each, sewn with sutures made of Gore-Tex, nylon, Prolene, or silk), and 48 unsutured controls. Each group of 24 samples sewn at one angle or the other with the different suture materials was assayed together with a corresponding control group of 12 unsutured samples. The mean tensile strengths in the unsutured controls ranged between 30.16 MPa and 43.42 MPa, whereas those of the sutured sets ranged from 14.68 MPa to 21.91 MPa. The latter presented a statistically significant loss of resistance (p < 0.01) when compared with the unsutured tissue samples. The angle of the suture with respect to the longitudinal axis influenced the degree of shear stress produced by the suture, as well as the behavior of the different suture materials used. The set of samples sewn with Prolene appeared to be that most sensitive to changes in the angle of the suture, whereas tissue sewn at a 45 degrees angle with Gore-Tex presented lower shear stress values in comparison with samples in which the other three materials were used. A method of tissue selection based on morphological and mechanical criteria was used to ensure the homogeneity of the results in such a way that the coefficients of determination (R2) for the stress/strain curve fitting equation ranged between 0.888 and 0.995. This excellent fit made it possible, applying regression analysis, to predict the mechanical behavior of a specimen by determining that of a contiguous tissue sample. Thus, it should be possible, at least theoretically, to characterize the behavior of a specific region or zone of the biomaterial. In conclusion, ostrich pericardium exhibits strong resistance to rupture, even when sutured. The selection method used ensures the homogeneity of the samples and, thus, of the results. The angle of the suture with respect to the longitudinal axis, where the load is centered, determines the shear stress produced by the suture and the mechanical behavior of each suture material.

Animals↗

Use of chemically purified and cross-linked bovine pericardium as a ligament substitute.

This study tested the reaction of a periarticular tissue to implanted pericardial membrane, substituting a segment of patellar ligament. Bovine pericardium was chemically purified and cross-linked with monomeric glutaraldehyde under pH, temperature and time conditions minimizing the polymerization of the cross-linking agent. Eight rats had both knee joint patellar ligaments excised. One side served as a control (simple suture), the other dissected ligament was replaced with a strip of pericardium. After 18 days and 12 weeks the dissected ligaments were analyzed by morphological methods. An unexpected fast ingrowth of cells and vessels was observed at 18 days. At 12 weeks new collagen deposits within pericardial patch were seen with striking biodegradation of the implant. Thus, using a new method of cross-linking the collagenous matrix with glutaraldehyde we see no evidence of glutaraldehyde cytotoxicity, as documented by our previous work.

Animals↗

The tensile strength of natural and chemically modified bovine pericardium.

Nondestructive and destructive uniaxial load tests were performed on natural and chemically modified bovine pericardium. Five specimens were selected from the same sites in different pericardial sacs by using a template. The mean maximum extension of one particular site in both the natural and chemically modified material was significantly greater than that of the other positions at a stress level of 0.6 Nmm.-2 The maximum extensibility of the fixed tissue was significantly greater (p less than 0.01) than that of the natural tissue. There was also an anatomical variation in tensile strength of the natural material which was retained after chemical modification. However, the overall tensile strength of the pericardium was not increased by this procedure. In contrast, glutaraldehyde fixation did increase the percentage strain at which fracture of this biomaterial occurred.

Aldehydes↗

The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium.

Tensile testing of tissue strips has been used to examine the effect of simple fixation in glutaraldehyde and formaldehyde on the viscoelastic properties of bovine pericardium. To assess tissue anisotropy, tissue strips were cut at 0 degree, 30 degrees, 60 degrees, and 90 degrees relative to the base-to-apex direction. Fresh anterior pericardium was modestly anisotropic, being least extensible in the base-to-apex direction; however, fixation removed this anisotropy. Fixation also produced a marked change in the response of the material to initial cyclic loading during preconditioning. Overall extensibility of the fixed material was significantly greater than that for the fresh tissue, consistent with a 10.7% shrinkage in aldehydes calculated from strain at fracture data. Reductions in stress relaxation and creep after fixation were noted as well, consistent with intrafibrillar crosslinking. Cyclic hysteresis and ultimate tensile strength were unaffected. Since the observed changes in the stress-strain response were largely attributable to shrinkage, control of shrinkage by physical means would allow for engineering modification of bovine pericardial mechanics for controlled anisotropy.

Aldehydes↗

The bovine pericardial xenograft: II. Effect of tethering or pressurization during fixation on the tensile viscoelastic properties of bovine pericardium.

Our previous article suggested that control of the extensibility of aldehyde-fixed pericardium could be achieved by controlling shrinkage during fixation. Therefore, to prevent shrinkage, we have used sandpaper-lined plexiglass plates to clamp circular samples of bovine pericardium during fixation in glutaraldehyde, tethering them at their original dimensions. As well, we have applied transmural pressures of 50 or 100 mm Hg during fixation using a hydraulic column of glutaraldehyde solution. Strips cut at 0 degree, 30 degrees, 60 degrees, and 90 degrees to the base-to-apex cardiac direction have been examined for cyclic stress-strain response, stress relaxation, plastic deformation, and fracture behavior. Under physiological stresses, tethered and pressure-fixed materials were both nearly isotropic. Tethering during fixation produced a material with extensibility nearly identical to that of fresh tissue. Plastic deformation during cyclic loading was reduced below that seen in simple fixation while stress relaxation was unchanged. Pressure-fixation produced reduced extensibility similar to that produced in porcine aortic valve leaflets. Plastic deformation and stress relaxation were both markedly reduced. Pressure-fixation reduced the strain at fracture, but fracture behavior was otherwise unaffected. Tethering and pressure-fixation offer attractive means to control the mechanical behavior of bovine xenograft materials.

Animals↗

Mapping of glutaraldehyde-treated bovine pericardium and tissue selection for bioprosthetic heart valves.

Glutaraldehyde-crosslinked bovine pericardium is widely used in bioprosthetic heart valve fabrication. In an attempt to set a scientific basis for more reproducible tissue selection, we produced and analyzed topographical maps of glutaraldehyde-treated bovine pericardium. Whole pericardia were divided into specific anatomical areas and their thickness was measured and mapped on templates. In each area, the suture holding power was determined in both parallel and perpendicular (to the base-apex line) directions; analyses of the tearing patterns in each fragment were used to evaluate predominant fiber orientation, and observations were confirmed by polarized light microscopy. Complete maps were superimposed graphically to aid in the selection of certain areas that would have known fiber orientation, high suture holding power, and suitable thickness. Our results describe regional heterogeneity of bovine pericardial structure and mechanical properties, specifically demonstrating variations in thickness, suture holding power, and collagen fiber orientation. Two areas of choice (representing about 35% of the total) were described as suitable for use in bioprosthetic heart valve fabrication.

Animals↗

Detection of remnant proteolytic activities in unimplanted glutaraldehyde-treated bovine pericardium and explanted cardiac bioprostheses.

The presence and activity of proteolytic enzymes has been investigated in vitro on soluble and insoluble preparations obtained from both unimplanted and implanted glutaraldehyde-treated bovine parietal pericardium. Using detection by colorimetric techniques, soluble preparations were shown to hydrolyze enzyme substrates that are characteristic for trypsin-like proteases, cathepsin-like proteases, and collagenase. As detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in gradient gels and gel filtration on Sepharose CL-6B, insoluble (pellet) preparations degraded denatured type I collagen in a time-dependent pattern, producing low-molecular-weight fragments. These activities were partially inhibited by phenylmethylsulfonyl fluoride, N-ethyl maleimide, soybean trypsin inhibitor, para-chloromercuribenzoic acid, or ethylenediaminetetraacetic acid, suggesting the presence of a heterogeneous enzymatic mixture. Insoluble preparations incubated with pure pericardial dermatan sulfate proteoglycan detached the glycosaminoglycan chains from their core protein carrier, producing a digestion pattern similar to Cathepsin C. These findings demonstrate the presence of active proteases in glutaraldehyde-fixed bovine pericardium per se and in explanted pericardial bioprosthetic cardiac valves, an additional factor that might contribute to intrinsic extracellular matrix degeneration in pericardial bioprosthetic devices.

Amino Acid Sequence↗

Durability of a cardiac valve leaflet made of calf pericardium: fatigue and energy consumption.

We studied the mechanical behavior of membranes of calf pericardium, similar to those employed in prosthetic valve leaflets, when subjected to tensile fatigue. The objective was to assess its durability, as a fundamental property of cardiac bioprosthesis, and analyze the energy consumption. For this purpose, the authors built a hydraulic simulator to subject a spherical valve leaflet made of calf pericardium to cyclic stress mimicking cardiac function. A total of 522 assays were performed in 40 samples, subjected to cyclic pressures greater than 6 atm, and 482 subjected to pressures ranging between 2 and 6 atm. The mathematical expression that establishes the relationship between the pressure exerted and the frequency was obtained. If we assume that the function is continuous, this equation provides the range of fatigue tolerated for a given number of cycles. Using the optimal values (the five highest values per series), the expression was found to be y = 9.95x(-0 1214) (R(2) = 0.955), where x represents the frequency in cycles per second and y the pressure in atmospheres. In addition, we established the mathematical relationship between the energy consumed and the frequency, which was a function of the pressure exerted, regardless of the region or zone from which the samples had been obtained. The methods of manual and morphology-based selection employed produced widely dispersed results. When a mechanical criterion was included, the similarity in the energy consumed during fatigue testing markedly improved the correlation, with a coefficient of determination between paired samples of R(2) = 0.7477. A mechanical criterion, such as energy consumption, can help to improve sample selection and produce more consistent results. Finally, we obtained the mathematical expression that relates the energy consumed to the pressure exerted and the number of cycles per second to which the valve leaflet was subjected. This procedure enables us to establish the limit to the energy that a biomaterial can consume over a period of time during which it is subjected to a working pressure and, thus, calculate more precisely its durability.

Animals↗

Tannic acid-stabilized pericardium tissue: IR spectroscopy, atomic force microscopy, and dielectric spectroscopy investigations.

Infrared (IR) spectroscopy, atomic force microscopy (AFM), and dielectric spectroscopy methods were employed to study structural and dynamic changes in the tannic acid (TA)-stabilized pericardium tissue. Chemically stabilized pericardium tissue is widely used in construction of the tissue derived bioprostheses. IR spectra recorded in the range 400-4000 cm-1 allowed us to recognize different types of TA-collagen interactions. Formation of hydrogen bonds between amine as well as amide NH groups from collagen and hydroxyl groups of TA was analyzed. The AFM imaging showed that the stabilization procedure with TA introduces considerable changes in both surface topography and thickness of collagen fibrils as well as in fibril arrangement on the tissue surface. It was found, that these structural changes have an impact on the dielectric behavior of the TA-stabilized tissue. The dielectric spectra for the native and TA-stabilized tissues were measured in the frequency and temperature ranges of 10(-1) -10(7) Hz and 120-270 K, respectively. The dielectric spectra revealed the relaxation process due to orientation of bound water supplemented by the fluctuation of collagen polar side groups. At the temperatures above approximately 210 K, the relaxation due to ion migration process was observed. It was found that both relaxation processes were influenced by the TA-collagen interaction.

Animals↗

Mechanical resistance of a new biomaterial, ostrich pericardium, and a new method of joining tissues combining suturing and a biological adhesive.

We studied the mechanical behavior in response to tensile stress of samples of ostrich pericardium bonded with a cyanoacrylate glue or sewn with a rectangular, overlapping suture that was subsequently sealed with the same bioadhesive. Seventy-two trials were performed in three series of 24 samples each: series AG, glued with an overlap of 1 cm2; series ASG, sewn with a rectangular, overlapping suture and sealed; and series AC, control samples that were left intact. The mean stress at rupture in series AG (glued) was 0.1 MPa, much lower than the working stress of a human valve leaflet, which is approximately 0.25 MPa. In the control series, this stress was 26.28 MPa. At rupture in series ASG (sutured/glued), the suture material was being subjected to a stress of 64.91 MPa, thus confirming the existence of an interaction between the suture and the shear stress exerted by the suture on the samples of pericardium. In series ASG, the mean value for the resistance to rupture when measured in machine kg was 8.83 kg, lower than but similar to that recorded in the control series AC (10.26 kg). The percentages of reversible deformation, or elongation, once the samples were torn were similar in series AC (19.15%) and ASG (21.93%). This phenomenon can only be explained by the damage to the collagen fibers in the area around the rupture, while other more distant regions work at a lower load within the elastic limit. We conclude that cyanocrylate adhesives alone are not suitable as bonding materials in cardiac bioprostheses. The results with the rectangular, overlapping suture, when subsequently sealed with an adhesive, can be considered good because, although this approach does not impede shear stress, it does maintain an excellent degree of resistance to rupture of the samples thus joined. We stress the need to take into account the concentration of the load in the design of bioprostheses.

Adhesives↗