Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “OXIMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Twenty-four-hour ambulatory oximetry monitoring in COPD patients with moderate hypoxemia.

BACKGROUND: The relationship of diurnal desaturations (oximetry-measured blood oxygen saturation [S(pO(2))] < 90%) during activities of daily living and clinical aspects in patients with chronic obstructive pulmonary disease (COPD) and moderate hypoxemia has not been systematically evaluated. METHODS: We prospectively studied 88 patients with stable COPD (forced expiratory volume in the first second [FEV(1)] < 80% of predicted, ratio of FEV(1) to forced vital capacity < 70% of predicted, and P(aO(2)) 60-70 mm Hg) with 24 hours of ambulatory oximetry. Desaturators were defined as those who spent >/= 30% of the time with S(pO(2)) < 90%. Patients engaged in their usual activities of daily living. We correlated these desaturations with the following variables, measured immediately before the 24 hours of oximetry: body mass index, dyspnea (measured with the modified Medical Research Council dyspnea scale), gas exchange, pulmonary function, quality of life (measured with the Saint George's respiratory questionnaire), and comorbidity (measured with the Charlson index). RESULTS: Thirty-three (38%) of the patients were desaturators: 50% nocturnal and 22% diurnal. We also measured daytime arterial blood gas values from arterial blood samples and found that the desaturators had higher P(aCO(2)) (p = 0.001) and lower P(aO(2)) (p = 0.007) than the nondesaturators. There were no differences in the other variables. The correlation between nocturnal and diurnal time with S(pO(2)) < 90% was r(2) = 0.67, and the concordance was low (Cohen's kappa 0.43, p < 0.001). CONCLUSIONS: Patients with stable COPD and moderate hypoxemia have frequent and potentially important desaturations during activities of daily living and at night. In addition, there is a big difference in the profile and degree of nocturnal and diurnal desaturations. Twenty-four hours of oximetry provides valuable information for comprehensive evaluation of patients with COPD.

Activities of Daily Living↗

[The importance of pulse oximetry for anesthesia].

With the combination of a noninvasive saturation measurement and plethysmography, pulse oximetry has become an important monitoring method for peripheral perfusion and oxygen supply. Indications for pulse oximetry is practically every anaesthesia especially in geriatric patients and patients with one-lung-anaesthesia, obesity, asthma and emphysema. Pulse oximetry has proved its worth in the transport of emergency patients. Sources of error are a bad perfusion at the site of measurement (hypotension, hypothermia), dyshaemoglobinaemia (Met-carboxy-haemoglobin) and interference of colours (dark skin, intravenous colours, high light intensity). Accuracy of response of most currently available pulse oximeters lies between 2-3% (SD) with oxygen saturations between 80-100%. Deviations increase at lower oxygen saturations. Pulse oximetry will soon be regarded as minimal monitoring standard worldwide together with the ECG, blood pressure, pulse and respiratory monitoring.

Anesthesia↗

[Pulse oximetry for noninvasive oxygen monitoring during dental treatment in children with congenital heart disease].

Children with congenital heart disease (CHD) are prone to present abrupt changes in cardiovascular functions which cause hypoxic spells or acute heart failure, so that oxygen monitoring during dental treatment is of great importance in cyanotic CHD patients. Monitoring of arterial oxygen saturation (SpO2) by pulse oximetry has several advantages, including rapid response time, freedom from skin injury, self-calibration and continuous readout of the SpO2 value. In these studies, SpO2 was measured in 68 pediatric patients (55 were CHD children and 13 were normal children) during dental treatment at the Pediatric Dentistry, Hokkaido University Dental Hospital. In all of the normal patients, SpO2 did not desaturate less than 95%. On the other hand, SpO2 ranged from 56% to 98% in CHD patients, and in 22% (n = 12) of these, SpO2 desaturated below 80%. All of the SpO2 less than 80% patients had been diagnosed as cyanotic CHD. Classification of CHD cases (n = 144, the total number of measurements) on the pattern of the SpO2 variation revealed that in 11% (n = 16) of the CHD cases, SpO2 decreased during dental treatment. Twelve of these 16 cases could not readily accept dental treatment. We suggest that behavior management is the most important factor in CHD patients for keeping SpO2 stable. Motion artifact of the SpO2 value, which was easily evoked when a patient bent his elbow or shook his finger, often made the pulse oximetry useless. In our studies, the SpO2 value sometimes became inaccurate in fearful infants or handicapped patients. Pulse waveform displayed on the front panel of pulse oximetry was useful to identify the motion artifact. We conclude that pulse oximetry is an appropriate apparatus for continuous arterial oxygen monitoring in pediatric patients during dental treatment as far as motion artifact is effectively eliminated.

Artifacts↗

An investigation of capnography and pulse oximetry as monitors of pediatric patients sedated for dental treatment.

Traditional methods of monitoring sedated pediatric dental patients have major shortcomings. This study evaluated the use of capnography in conjunction with pulse oximetry for monitoring children during conscious sedation for dental treatment. The specific purposes of the study were to determine if capnography would: (1) detect ventilatory changes that subsequently cause an oxyhemoglobin desaturation as detected by pulse oximetry; and (2) detect an airway obstruction. Ten pediatric dental patients (mean age 2 years, 10 months) were sedated with 75 mg/kg of chloral hydrate in strict accordance with the Guidelines for the Elective Use of Conscious Sedation, Deep Sedation, and General Anesthesia in Pediatric Patients of the American Academy of Pediatric Dentistry and the American Academy of Pediatrics (1985). All patients were monitored continuously using both capnography and pulse oximetry. Analysis of data obtained using these monitors revealed that specific end-tidal CO2 values were not predictive for subsequent oxyhemoglobin desaturations and that capnography was very accurate in detecting complete obstruction of the airway. Pulse oximetry revealed that all patients had mild oxyhemoglobin desaturations and that 50% had moderate desaturations.

Anesthesia, Dental↗

[Comparison of O2 saturation measurements by oximetry and by gas analysis].

For checking the reliability of pulse oximetry in the operating rooms, we compared values of arterial O2 saturation measured by a blood gas analyzer (SAT) with values monitored by pulse oximetry (SaO2). SaO2's were found to be significantly different from SAT's. The regression equation was SAT = 0.31 X SaO2 + 68.4 and the correlation coefficient was 0.66. P value of paired comparison was 0.0001 indicating that the two sets of values were not equal to each other. When one observer performed a similar study using a high-fidelity pulse oximeter, SaO2's were not different from SAT's. The regression equation in this case was SAT = 0.85 X SaO2 + 15.0 and the correlation coefficient was 0.95. P value of paired comparison was 0.3244. The reliability of pulse oximetry differs from one anesthesiologist to another and depends upon the accuracy of each pulse oximeter. In clinical experiment, using the data by pulse oximetry in operating room is misleading.

Blood Gas Analysis↗

[Pulse oximetry for the assessment of lower extremity ischemia].

The purpose of this study was to compare pulse oximetry with ankle and toe pressure measurements in a group of 25 patients with lower limb ischaemia. Measurements were performed on 49 limbs. Pulse oximetry recordings from the second toe were obtainable in only 28 (57%) cases. With lower ankle or toe pressure and more severe symptoms, oximetry was less likely to be possible. In all cases of successful recordings, the oxygen saturation at second toe level was identical with the finger saturation. These data indicate that pulse oximetry has no value in the assessment of peripheral arterial occlusive disease.

Arteriosclerosis↗

Value of pulse oximetry in screening for long-term oxygen therapy requirement.

Pulse oximetry, combined with spirometry, was evaluated as a method of selecting chronic obstructive pulmonary disease (COPD) out-patients requiring definitive arterial blood gas analysis for long-term oxygen therapy (LTOT) assessment. A relatively high screening arterial oxygen saturation by pulse oximetry (SaO2) level was set, in order to maximize sensitivity. All 113 COPD out-patients attending the hospital clinic over a 6 month period were screened. Sixty had a forced expiratory volume in one second < 1.5 l and 26 had an SaO2 < or = 92%. These 26 underwent arterial blood gas analysis. Nine had an arterial oxygen tension < 7.3 kPa all with an arterial carbon dioxide tension (PaCO2) > 6 kPa. A further eight had a PaO2 < 8 kPa. This produced a sensitivity of 100% and specificity of 69% for oximetry in the detection of PaO2 < 7.3 kPa determined by direct arterial puncture and 100% and 86% respectively for detecting a PaO2 < 8 kPa. Although the poor specificity of oximetry in the crucial PaO2 range makes it unsuitable, when used alone, for prescription of LTOT, it may prove valuable in selecting patients who require further definitive arterial blood gas analysis.

Aged↗

A successful protocol for the use of pulse oximetry to classify arterial oxygenation into four fuzzy categories.

Pulse oximetry is widely used in critical care medicine to noninvasively estimate arterial hemoglobin oxygen saturation. Despite the obvious benefits of using pulse oximetry to detect life threatening desaturations, it is unknown how well pulse oximetry is able to predict the finer graduations of arterial oxygenation needed for clinical decision making. A computerized protocol was developed for the use of pulse oximetry to classify arterial oxygenation into four fuzzy categories and tested in a prospective clinical trial which compared the oxygenation category assigned by the protocol to one assigned by a respiratory therapist. In 3,742 classifications from 15 patients over a seven month period, the protocol showed 96% agreement with the therapists in the direction of therapy and 75% agreement with the oxygenation classes assigned by the therapists.

Clinical Protocols↗

Pulse oximetry correction for smoking exposure.

Pulse oximetry oxygen saturation (SpO2) does not distinguish carboxyhemoglobin (COHb) from oxyhemoglobin (O2Hb), giving a false impression of the apparent degree of oxyhemoglobin saturation in smokers who have elevated levels of COHb. We questioned whether accounting for smoking exposure history could improve description of pulse oximetry by correcting for COHb levels. We evaluated smoking history and %SpO2 as predictors of %O2Hb and %COHb by CO-oximetry of arterial blood in 18 actively smoking and 18 age-matched nonsmoking patients in a clinical pilot study. The difference between %SpO2 and %O2Hb was significantly greater (p < 0.001) in the smokers (5.6 +/- 3.1) than the nonsmokers (2.1 +/- 2.1). This difference correlated with %COHb (rp = 0.789; p < 0.001) and the smoking exposure score (SES, rp = 0.621; p < 0.001), a six-point index we developed based on whether patients were active smokers, refrained from smoking prior to testing, or were exposed to passive smoking in the home or workplace. The following formula summarizes the correction: %O2Hb = 0.882[%SpO2] - 0.968[SES] + 9.245 (rp = 0.841; SES = 2.478; p < 0.001). This pilot study suggests that smoking exposure history correlates with COHb levels and that correction for smoking exposure improves the accuracy of pulse oximetry.

Carboxyhemoglobin↗

Advances in pulse oximetry.

The interaction between light and tissue is the basis of pulse oximetry. This review focuses on the recent development of pulse oximetry, with special emphasis on the reflection oximetry utilized in fetal and cerebral oximetry.

Journal Article↗

Recent findings in the use of reflectance oximetry: a critical review.

PURPOSE OF REVIEW: Pulse oximetry is ubiquitous but detailed understanding of the technology is poor. This is illustrated by publications addressing knowledge of pulse oximetry and those warning against the use of transmission pulse oximeter sensors in a reflectance manner, unintended by the manufacturers, owing to the potential for iatrogenic problems. Reflectance oximetry sensors are distinct and their application rather specific. Users must adhere to the manufacturer's guidelines to be assured of approximating the claimed accuracy and other specifications. Moreover, a thorough understanding of the device's shortcomings will optimize performance and avoid misuse. Cautious skepticism is appropriate with use of any technology but particularly with indirect measures of vital signs. RECENT FINDINGS: The studies of reflectance sensors described here illustrate a diversity of successful applications and opportunities for further research. The genesis of applications for some sensors, for example fetal sensors, has proven helpful in other clinical settings where low mean arterial pressure and need for accurate monitoring of a SpO2 of less than 80% is poorly provided by transmittance sensors. Reflectance sensors are more prone to placement over contaminating sources (for example arteries and pigmentation), but their more sophisticated design can provide greater versatility than transillumination methods. SUMMARY: This invited review highlights recent developments and applications of reflectance oximetry with an emphasis on the potential clinical and research advantages.

Journal Article↗

Accuracy of oximetry for detection of respiratory disturbances in sleep apnea syndrome.

STUDY OBJECTIVE: The cost and inconvenience of polysomnography make simplified techniques of screening desirable in the strategy of diagnosis of sleep apnea syndrome (SAS). We have evaluated, in a prospective study of 301 consecutive patients referred for suspected sleep disorders, an index (delta index) that detects apneic events by quantifying arterial oxygen saturation (SaO2) variability. SETTING: Regional sleep laboratory taking referrals from general practitioners and specialists. DESIGN: Classic polysomnography was the gold standard, with 15 apneas plus hypopneas per hour (RDI) being used as a threshold for definition of obstructive sleep apnea (OSA). Oximetry was recorded over the same night. Signal variability was quantified as a function of time, using digital processing of oximetric data. Sensitivity, specificity, and positive and negative predictive values of oximetry testing were calculated. A receiver operating characteristic (ROC) curve was constructed representing the comparative courses of sensitivity and 1-specificity at different thresholds of delta index. RESULTS: Three hundred one patients were included (age, 56 +/- 12 years). Their RDI was 30 +/- 24. For a delta threshold at 0.6, the sensitivity of oximetry for the diagnosis of OSA was 98% and the specificity was 46%. The positive and negative predictive values for diagnosing SAS were 77% and 94%, respectively. The three false-negative cases had a relatively high awake SaO2 (97 vs 93.9 +/- 2.8%), a moderate RDI (23.3 +/- 1.6), and were less obese than the other patients (body mass index: 25 +/- 3 vs 33 +/- 8). The 58 false-positive cases had an RDI of 8 +/- 4, an awake SaO2 of 93.1 +/- 3.6 vs 94.1 +/- 2.6 for the rest of the population (p = 0.01). Finally, the false-positive cases had more airways obstruction (FEV1/VC = 72 +/- 13 vs 77 +/- 15%; p = 0.026). Using a delta value of 0.8 leads to a sensitivity of 90% with 19 false-negative cases but with a higher specificity of 75%. CONCLUSIONS: A nocturnal oximetry test with a delta index below 0.6 is helpful in ruling out the diagnosis of SAS in patients being screened for this condition, as this yielded only three negative test results in 301 screening procedures.

Aged↗

[Study of static transcutaneous oximetry before amputation in patients with arteritis].

Transcutaneous oximetry has been used to define the level of amputation in arteritic patients, with discrepant results. We have studied preoperative statix oximetry in 33 arteritic patients at the Leriche-Fontaine Stage IV, who underwent 36 amputations (thighs = 6, Legs+Symes = 14, transmetatarsal = 7, toes = 9). Oximetry included the measurement, at the level of amputation, of the transcutaneous partial oxygen pressure (tc pO2), of the tissue oxygenation ratio (TOR), preferably with a precordial electrode, of the tc pO2 gain after oxygen inhalation and of the gain ratio with the reference electrode. Two patients died postoperatively, the amputation stump did not heal in another 8 patients. The tc pO2 value was 36.6 +/- 16.2 mm Hg in the healed group and 21.1 +/- 19.9 mm Hg in the non healed group. The TOR respectively was 71.2 +/- 32.7% and 38.6 +/- 29.9% in these two groups. These differences were statistically significant. The difference between the two groups in the measurements made after the oxygenation test was not statistically significant. With a tc pO2 threshold at 26 mm Hg, the sensitivity was 73% and the specificity 75%, the positive predictive value 90%, the negative predictive value 46% and the value of the test 73.5%. The thresholds calculated to be 56% for TOR, 11 mm Hg for the gain and 32% for the gain ratio, did not improve the performances of oximetry. In our study, the tc pO2 was the parameter that best allowed predicting healing was obtained with smaller values than the threshold. Other elements such as the general condition and diabetes have played a role in the prognosis.

Aged↗

Continuous mixed venous oximetry in critically ill surgical patients. 'High-tech' cost-effectiveness.

Mixed venous oxygen saturation (Svo2) provides a measure of cardiorespiratory ability to meet the body's needs for oxygen. The Svo2 was measured continuously in 20 critically ill surgical patients using a pulmonary-artery oximetry system. The accuracy of the technique was validated by comparing initial continuous Svo2 to the laboratory determination of Svo2. Oximetry was used to guide therapeutic decisions regarding fluid, inotropic agents, vasodilators and ventilator setting and was useful in ten cases. Sepsis developed in nine patients; this severely limited the usefulness of the technique. With clinical decision making based on oximetry, there was a savings per catheter of 2.65 cardiac output determinations and 5.9 venous blood gas determinations, resulting in a net savings per catheter of +75.

Blood Gas Analysis↗

Unexplained decrease in measured oxygen saturation by pulse oximetry following injection of Lymphazurin 1% (isosulfan blue) during a lymphatic mapping procedure.

A rare case of alteration in measured pulse oximetry during a lymphatic mapping procedure for cervical carcinoma is reported. Over a 5-min period following injection of perilesional Lymphazurin 1% dye (3 ml total), a profound pulse oximetry desaturation was observed. Concomitant arterial blood gas determinations confirmed patient's well-being. Interaction of this agent's absorptive spectroscopy and wavelengths used to measure oxygen saturation by commercial pulse oximetry devices is suspected.

Adult↗

Hemoglobinopathy case finding by pulse oximetry.

Pulse oximetry is a widely used, noninvasive instrument for monitoring oxygen saturation. Its use, however, is limited in the setting of dyshemoglobinemias. We report a case of hemoglobin Rothschild in an Asian patient diagnosed as a result of routine pulse oximetry. This case reiterates the limitations of pulse oximetry in patients with dyshemoglobinemias, while introducing its use as a case-finding tool for such conditions.

Diagnostic Tests, Routine↗

Pulse oximetry: a new non-invasive assessment of peripheral arterial occlusive disease.

Peripheral skin perfusion reflects the level of vascularity and viability of a limb and may help in planning the site of amputation or bypass surgery in patients with vascular disease. This study used peripheral pulse oximetry in 20 healthy volunteers and in 20 patients with limb ischaemia. Pulse oximetry saturation levels (Psa,O2) were compared with ankle artery Doppler pressures and transcutaneous oxygen measurements (Ptc,O2). Recordings were taken at two standard sites distally and referenced to finger and forearm to calculate an index. A significant correlation was found between Ptc,O2 and Psa,O2 in patients with ischaemia (r = 0.68, P less than 0.01). A further group of 12 patients with acute limb ischaemia was similarly assessed before and after revascularization. After revascularization mean(s.d.) Ptc,O2 increased from 38(13) to 44(1) mmHg (P greater than 0.05) and mean(s.d.) Psa,O2 increased from 86(3) to 90(4) per cent (P less than 0.01). These data suggest that pulse oximetry is a more sensitive index of peripheral perfusion than Ptc,O2 or ankle artery Doppler pressure and that, because of its accuracy and simplicity, it merits further use.

Angioplasty, Balloon↗

Accuracy of oxygen measurements in T2 (line width) EPR oximetry.

EPR oximetry is used for in vivo and in vitro measurements of oxygen in biological systems, including experimental animals. The accuracy of oxygen measurements in T2 (line width) EPR oximetry is significantly improved if least-squares simulation is used to extract the line width parameters. The oxygen effect on the EPR spectra of nitroxide solutions and aqueous suspensions of fusinite can be described as an additional homogeneous broadening that modifies the EPR spectrum of the oxygen-free probe. This allows one to use a one-parameter line width model in most cases. The simulations were carried out with the use of a fast-convolution algorithm followed by Levenberg-Marquardt optimization. The validity of error estimates provided by this method was tested on sets of experimental spectra taken under common conditions. It is shown that the accuracy of oxygen measurements in line width (T2) oximetry is determined not only by the probe sensitivity (rate of line width change versus oxygen concentration), but also by the signal-to-noise ratio, inhomogeneous contribution to the line shape (e.g., unresolved proton superhyperfine structure), and the spectral window. The accuracy of oxygen measurements is compared for aqueous solutions of two nitroxide radicals with different superhyperfine structure and for aqueous suspensions of fusinite.

Carbon↗