Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “NASA Center JSC”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Active dosimetric measurements on shuttle flights.

A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of linear energy transfer (LET) and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 degrees x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.

Cosmic Radiation↗

Short-duration spaceflight does not prolong QTc intervals in male astronauts.

Although ventricular dysrhythmias are not increased during, and QTc intervals are not prolonged after, short-duration (5 to 16 days) spaceflights, QTc intervals have not previously been reported during these shorter flights. Holter monitor recordings, obtained in 11 male astronauts who flew on shuttle missions ranging from 5 to 10 days, showed that QTc intervals did not change significantly 10 days before launch, on 2 separate days of spaceflight, and 2 days after landing. Taken together, these data and our previous report show that QTc interval prolongation occurs sometime between the 9th and 30th days of spaceflight.

Adult↗

Mechanism of spaceflight-induced changes in left ventricular mass.

Decrements in left ventricular (LV) mass observed after microgravity exposure have been previously postulated to be a central component of spaceflight-induced cardiovascular deconditioning. In this study, echocardiographic measurements of LV mass in astronauts demonstrated a comparative 9.1% reduction in postflight LV mass that returned to preflight values by the third day of recovery. A ground-based study in normal subjects determined that these pre- to postflight LV mass changes could be reproduced by simple dehydration. Reductions in LV mass observed immediately after spaceflight may be secondary to simple physiologic fluid exchanges.

Adult↗

Simultaneous measurement of multiple radiation-induced protein expression profiles using the Luminex(TM) system.

Space flight results in the exposure of astronauts to a mixed field of radiation composed of energetic particles of varying energies, and biological indicators of space radiation exposure provides a better understanding of the associated long-term health risks. Current methods of biodosimetry have employed the use of cytogenetic analysis for biodosimetry, and more recently the advent of technological progression has led to advanced research in the use of genomic and proteomic expression profiling to simultaneously assess biomarkers of radiation exposure. We describe here the technical advantages of the Luminex(TM) 100 system relative to traditional methods and its potential as a tool to simultaneously profile multiple proteins induced by ionizing radiation. The development of such a bioassay would provide more relevant post-translational dynamics of stress response and will impart important implications in the advancement of space and other radiation contact monitoring.

Antibodies↗

Engineering concepts for inflatable Mars surface greenhouses.

A major challenge of designing a bioregenerative life support system for Mars is the reduction of the mass, volume, power, thermal and crew-time requirements. Structural mass of the greenhouse could be saved by operating the greenhouse at low atmospheric pressure. This paper investigates the feasibility of this concept. The method of equivalent system mass is used to compare greenhouses operated at high atmospheric pressure to greenhouses operated at low pressure for three different lighting methods: natural, artificial and hybrid lighting.

Air Conditioning↗

High LET-induced H2AX phosphorylation around the Bragg curve.

We investigated the spatial distribution of the induction of the phosphorylated form of the histone protein H2AX (gamma-H2AX), known to be activated by DSBs. Following irradiation of human fibroblast cells with 600 MeV/nucleon silicon and 600 MeV/nucleon iron ions we observed the formation of gamma-H2AX aggregates in the shape of streaks stretching over several micrometers in an x/y plane. Polyethylene shielding was used to achieve a Bragg curve distribution with beam geometry parallel to the monolayer of cells. We present data that highlights the formation of immunofluorescent gamma-H2AX tracks showing the ion trajectories across the Bragg peak of irradiated human fibroblast cells. Qualitative analyses of these distributions indicated potentially increased clustering of DNA damage before the Bragg peak, enhanced gamma-H2AX distribution at the peak, and provided visual evidence of high-linear energy transfer particle traversal of cells beyond the Bragg peak in agreement with one-dimensional transport approximations. Spatial assessment of gamma-H2AX fluorescence may provide direct insights into DNA damage across the Bragg curve for high charge and energy ions including the biological consequences of shielding and possible contributors to bystander effects.

Bystander Effect↗

Comparison of genotoxic damage in monolayer cell cultures and three-dimensional tissue-like cell assemblies.

Assessing the biological risks associated with exposure to the high-energy charged particles encountered in space is essential for the success of long-term space exploration. Although prokaryotic and eukaryotic cell models developed in our laboratory and others have advanced our understanding of many aspects of genotoxicity, in vitro models are needed to assess the risk to humans from space radiation insults. Such models must be representative of the cellular interactions present in tissues and capable of quantifying genotoxic damage. Toward this overall goal, the objectives of this study were to examine the effect of the localized microenvironment of cells, cultured as either 2-dimensional (2D) monolayers or 3-dimensional (3D) aggregates, on the rate and type of genotoxic damage resulting from exposure to Fe-charged particles, a significant portion of space radiation. We used rodent transgenic cell lines containing 50-70 copies of a LacI transgene to provide the enhanced sensitivity required to quantify mutational frequency and type in the 1100-bp LacI target as well as assessment of DNA damage to the entire 45-kbp construct. Cultured cells were exposed to high energy Fe charged particles at Brookhaven National Laboratory's Alternating Gradient Synchrotron facility for a total dose ranging from 0.1 to 2 Gy and allowed to recover for 0-7 days, after which mutational type and frequency were evaluated. The mutational frequency was found to be higher in 3D samples than in 2D samples at all radiation doses. Mutational frequency also was higher at 7 days after irradiation than immediately after exposure. DNA sequencing of the mutant targets revealed that deletional mutations contributed an increasingly high percentage (up to 27%) of all mutations in cells as the dose was increased from 0.5 to 2 Gy. Several mutants also showed large and complex deletions in multiple locations within the LacI target. However, no differences in mutational type were found between the 2D and the 3D samples. These 3D tissue-like model systems can reduce the uncertainty involved in extrapolating risk between in vitro cellular and in vivo models.

Animals↗

Changes in neutrophil functions in astronauts.

Exploration class human spaceflight missions will require astronauts with robust immune systems. Innate immunity will be an essential element for the healthcare maintenance of astronauts during these lengthy expeditions. This study investigated neutrophil phagocytosis, oxidative burst, and degranulation of 25 astronauts after four space shuttle missions and in nine healthy control subjects. Space flight duration ranged from 5 to 11 days. Blood specimens were obtained 10 days before launch, immediately after landing, and 3 days after landing. The number of neutrophils increased by 85% at landing compared to preflight levels. The mean values for phagocytosis of Escherichia coli and oxidative burst capacity in neutrophils from astronauts on the 5-day mission were not significantly different from those observed in neutrophils from the control subjects. Before and after 9- to 11-day missions, however, phagocytosis and oxidative burst capacities were significantly lower than control mean values. No consistent changes in degranulation or expression of surface markers were observed before or after any of the space missions. This study indicates that neutrophil phagocytic and oxidative functions are affected by factors associated with space flight and this relationship may depend on mission duration.

Age Factors↗

Changes in monocyte functions of astronauts.

As part of the systematic evaluation of the innate immune system for long duration missions, this study focused on the antimicrobial functions of monocytes in astronauts participating in spaceflight. The study included four space shuttle missions and 25 astronauts. Nine non-astronauts served as controls. Blood specimens were collected 10 days before launch, within 3h after landing, and again 3 days after landing. The number of monocytes did not differ significantly over the interval sampled in both the astronaut or control groups. However, following 5-11 days of spaceflight, the astronauts' monocytes exhibited reductions in ability to engulf Escherichia coli, elicit an oxidative burst, and degranulate. The phagocytic index was significantly reduced following spaceflight when compared to control values. This reduction in phagocytosis was accompanied by changes in the expression of two surface markers involved in phagocytosis, CD32 and CD64. Levels of cortisol, epinephrine, and norepinephrine after spaceflight did not increase over preflight values.

Adaptation, Physiological↗

Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals.

High frequency electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. Therefore, we prospectively investigated the reproducibility of the root mean squared voltage, kurtosis, and the presence versus absence of reduced amplitude zones in signal averaged 12-lead high frequency QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of root mean squared voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of root mean squared voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. Reduced amplitude zones were also reproducible up to a rate of 87% and 81%, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead high frequency QRS electrocardiograms are sufficiently reproducible for clinical use.

Adult↗

Evaluation of surgical skills in microgravity using force sensing.

INTRODUCTION: Force measurements can be used to characterize surgical maneuvers in microgravity. METHODS: : A series of surgical tasks was performed by a group of 20 participants (n=20) both in 1g on the ground and in 0 g aboard NASA's KC-135 aircraft in parabolic flight. The group included astronauts, a flight surgeon, surgeons, physicians, Ph.D.-scientists, and technical personnel. The interaction forces between the surgical instruments and the mock tissue were measured for a clip-applying, suturing, grasping, and cutting. Seven evaluations in 1g and a single evaluation in 0 g were performed by each of the participants. RESULTS: The data from a single participant are examined in detail. Statistical results for the group of 20 participants do not show significant differences in the average or peak forces during clip-applying or in the average forces applied during suturing in 0 g versus in 1g. However, the results do show statistically greater (43% higher) peak forces during suturing in microgravity. DISCUSSION: These data show the usefulness of analyzing force information to assess surgical task performance in microgravity. Although peak suturing forces were statistically higher in microgravity, their clinical relevance is unknown, but likely would not result in a change in clinical outcome. Overall, the data suggest that forces exerted during surgical tasks will not pose a significant barrier to effective surgery in microgravity.

Aerospace Medicine↗

Dietary studies in the joint US-Russian space program.

Metabolic experiments in the joint US-Russian space program involve analysis of food records, which include weighed foods, stable-isotope turnover, and biochemical samples collected before, during, and after the flights. This article describes the methods of monitoring dietary intake for this program.

Aerospace Medicine↗

Evaluation of cardiac rhythm disturbances during extravehicular activity.

This study represents the first systematic evaluation of dysrhythmias before, during, and after spaceflight including extravehicular activity (EVA). The data, based on 7 Shuttle crew members, revealed a nonsignificant decrease in ventricular and supraventricular ectopy during EVA, suggesting that the incidence of dysrhythmias is no greater during EVA than with any other phase of a mission or preflight.

Adult↗

A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples.

A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

Astronomy↗

Motion sickness and proprioceptive aftereffects following virtual environment exposure.

To study the potential aftereffects of virtual environments (VE), tests of visually guided behavior and felt limb position (pointing with eyes open and closed) along with self-reports of motion sickness-like discomfort were administered before and after 30 min exposure of 34 subjects. When post- discomfort was compared to a pre-baseline, the participants reported more sickness afterward (p < 0.03). The change in felt limb position resulted in subjects pointing higher (p < 0.038) and slightly to the left, although the latter difference was not statistically significant (p = 0.08). When findings from a second study using a different VE system were compared, they essentially replicated the results of the first study with higher sickness afterward (p < 0.001) and post- pointing errors were also up (p < 0.001) and to the left (p < 0.001). While alternative explanations (e.g. learning, fatigue, boredom, habituation, etc.) of these outcomes cannot be ruled out, the consistency of the post- effects on felt limb position changes in the two VE implies that these recalibrations may linger once interaction with the VE has concluded, rendering users potentially physiologically maladapted for the real world when they return. This suggests there may be safety concerns following VE exposures until pre-exposure functioning has been regained. The results of this study emphasize the need for developing and using objective measures of post-VE exposure aftereffects in order to systematically determine under what conditions these effects may occur.

Adult↗

Elongated prismatic magnetite crystals in ALH84001 carbonate globules: potential Martian magnetofossils.

Using transmission electron microscopy (TEM), we have analyzed magnetite (Fe3O4) crystals acid-extracted from carbonate globules in Martian meteorite ALH84001. We studied 594 magnetites from ALH84001 and grouped them into three populations on the basis of morphology: 389 were irregularly shaped, 164 were elongated prisms, and 41 were whisker-like. As a possible terrestrial analog for the ALH84001 elongated prisms, we compared these magnetites with those produced by the terrestrial magnetotactic bacteria strain MV-1. By TEM again, we examined 206 magnetites recovered from strain MV-1 cells. Natural (Darwinian) selection in terrestrial magnetotactic bacteria appears to have resulted in the formation of intracellular magnetite crystals having the physical and chemical properties that optimize their magnetic moment. In this study, we describe six properties of magnetite produced by biologically controlled mechanisms (e.g., magnetotactic bacteria), properties that, collectively, are not observed in any known population of inorganic magnetites. These criteria can be used to distinguish one of the modes of origin for magnetites from samples with complex or unknown histories. Of the ALH84001 magnetites that we have examined, the elongated prismatic magnetite particles (similar to 27% of the total) are indistinguishable from the MV-1 magnetites in five of these six characteristics observed for biogenically controlled mineralization of magnetite crystals.

Biomarkers↗