Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “METALS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Heavy metals in urban soils of East St. Louis, IL, Part I: Total concentration of heavy metals in soils.

The city of East St. Louis, IL, has a history of abundant industrial activities including smelters of ferrous and non-ferrous metals, a coal-fired power plant, companies that produce organic and inorganic chemicals, and petroleum refineries. A protocol for soil analysis was developed to produce sufficient information on the extent of heavy metal contamination in East St. Louis soils. Soil cores representing every borough of East St. Louis were analyzed for heavy metals--As, Cd, Cu, Cr, Hg, Ni, Pb, Sb, Sn, and Zn. The topsoil contained heavy metal concentrations as high as 12.5 ppm Cd, 14,400 ppm Cu, ppm quantities of Hg, 1860 ppm Pb, 40 ppm Sb, 1130 ppm Sn, and 10,360 ppm Zn. Concentrations of Sb, Cu, and Cd were well correlated with Zn concentrations, suggesting a similar primary industrial source. In a sandy loam soil from a vacated rail depot near the bank of the Mississippi River, the metals were evenly distributed down to a 38-cm depth. The clay soils within a half-mile downwind of the Zn smelter and Cu products company contained elevated Cd (81 ppm), Cu (340 ppm), Pb (700 ppm), and Zn (6000 ppm) and displayed a systematic drop in concentration of these metals with depth. This study demonstrates the often high concentration of heavy metals heterogeneously distributed in the soil and provides baseline data for continuing studies of heavy metal soil leachability.

Hydrogen-Ion Concentration↗

Effects of extracting reagents and metal speciation on the removal of heavy metal contaminated soils by chemical extraction.

Chelating agents and acids were evaluated for removing heavy metals from contaminated soils. Two soils, latosols soil and sandatone-shale alluvial soil, artificially contaminated with Cu, Zn, and Pb were investigated. The removal efficiencies of Cu, Zn, and Pb from both soils for various chelating agents and acids followed the descending order EDTA > DTPA > Citric Acid > HCl. Heavy metals were associated in latosols soil with 34, 40, and 33% in the exchangeable fraction for Cu, Zn, and Pb, respectively. However, heavy metals were associated in sandatone-shale alluvial soil in stronger adsorbed forms with 40, 55, and 42% in the Fe-Mn oxides fraction for Cu, Zn, and Pb, respectively. Effect of EDTA concentration on the removal efficiency of heavy metals was examined for a wide range of 1 x 10(-4) to 5 x 10(-2) M. When EDTA concentration was low in the range from 1 x 10(-4) to 1 x 10(-3) M, the removal efficiencies of all the heavy metals from latosols soil were higher than those from sandatone-shale alluvial soil. The higher removal efficiencies of heavy metals observed in latosols soil than those in sandatone-shale alluvial soil is proved due to that the heavy metals in latosols soil were associated in weaker adsorption forms than heavy metals associated in sandatone-shale alluvial soil.

Acids↗

Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty.

Seventy uncemented stemmed total hip replacements and 35 uncemented surface replacements with all metal Metasul articulating surfaces were followed up in a prospective study. There was no evidence that this metal on metal articulation causes new problems or complications that were not known already from other polyethylene-aluminum oxide ceramic articulating combinations. The results of 64 of 70 patients could be assessed as excellent and good. When tissue samples obtained during 2 reoperations for ectopic ossification were examined histologically, there was no light microscopic evidence of metal particles. In these cases, aseptic loosening seemed to be due to the lack of initial fixation with the original femoral component design, and was not related to the use of the Metasul bearing. The metal on metal articulation reduces the production of particles considerably according to experience to date. It is therefore hoped that foreign body reactions due to wear particles will be significantly reduced. The results support the continued investigation of metal on metal joint replacements for younger, active patients.

Adolescent↗

Functional expression of a bacterial heavy metal transporter in Arabidopsis enhances resistance to and decreases uptake of heavy metals.

Large parts of agricultural soil are contaminated with lead (Pb) and cadmium (Cd). Although most environments are not heavily contaminated, the low levels observed nonetheless pose a high risk of heavy metal accumulation in the food chain. Therefore, approaches to develop plants with reduced heavy metal uptake are important. Recently, many transgenic plants with increased heavy metal resistance and uptake of heavy metals were developed for the purpose of phytoremediation. However, to reduce heavy metal in the food chain, plants that transfer less heavy metals to the shoot are required. We tested whether an Escherichia coli gene, ZntA, which encodes a Pb(II)/Cd(II)/Zn(II) pump, could be useful for developing plants with reduced heavy metal content. Yeast cells transformed with this gene had improved resistance to Pb(II) and Cd(II). In Arabidopsis plants transformed with ZntA, ZntA was localized at the plasma membrane and improved the resistance of the plants to Pb(II) and Cd(II). The shoots of the transgenic plants had decreased Pb and Cd content. Moreover, the transgenic protoplasts showed lower accumulation of Cd and faster release of preloaded Cd than wild-type protoplasts. These results show that a bacterial transporter gene, ZntA, can be functionally expressed in plant cells, and that that it may be useful for the development of crop plants that are safe from heavy metal contamination.

Adenosine Triphosphatases↗

Metal ions and phosphate binding in the H-N-H motif: crystal structures of the nuclease domain of ColE7/Im7 in complex with a phosphate ion and different divalent metal ions.

H-N-H is a motif found in the nuclease domain of a subfamily of bacteria toxins, including colicin E7, that are capable of cleaving DNA nonspecifically. This H-N-H motif has also been identified in a subfamily of homing endonucleases, which cleave DNA site specifically. To better understand the role of metal ions in the H-N-H motif during DNA hydrolysis, we crystallized the nuclease domain of colicin E7 (nuclease-ColE7) in complex with its inhibitor Im7 in two different crystal forms, and we resolved the structures of EDTA-treated, Zn(2+)-bound and Mn(2+)-bound complexes in the presence of phosphate ions at resolutions of 2.6 A to 2.0 A. This study offers the first determination of the structure of a metal-free and substrate-free enzyme in the H-N-H family. The H-N-H motif contains two antiparallel beta-strands linked to a C-terminal alpha-helix, with a divalent metal ion located in the center. Here we show that the metal-binding sites in the center of the H-N-H motif, for the EDTA-treated and Mg(2+)-soaked complex crystals, were occupied by water molecules, indicating that an alkaline earth metal ion does not reside in the same position as a transition metal ion in the H-N-H motif. However, a Zn(2+) or Mn(2+) ions were observed in the center of the H-N-H motif in cases of Zn(2+) or Mn(2+)-soaked crystals, as confirmed in anomalous difference maps. A phosphate ion was found to bridge between the divalent transition metal ion and His545. Based on these structures and structural comparisons with other nucleases, we suggest a functional role for the divalent transition metal ion in the H-N-H motif in stabilizing the phosphoanion in the transition state during hydrolysis.

Amino Acid Motifs↗

Potential efficacy of low metal diets and dental metal elimination in the management of atopic dermatitis: an open clinical study.

We performed an open clinical study on the effects of low metal diets and/or dental metal elimination on 27 patients with moderate to severe atopic dermatitis (AD), who showed positive patch tests for metal allergens and/or clinical exacerbation by oral provocation tests with metal salts. All the patients were recommended to ingest low metal diets for 3 months and/or undergo dental metal elimination. Marked or moderate improvement was noted in 18 patients (67%); 7 patients (26%) showed marked improvement and 11 patients (41%), moderate improvement. Nine patients (33%) showed minimal improvement or no change. In the patients who showed marked or moderate improvement, we observed statistically significant decreases (p < 0.05) in both peripheral blood eosinophil counts and serum LDH levels after 3 months of treatment. The present study suggests that restriction of ingested metal allergens to which patients have positive patch tests and/or oral challenge tests may be useful in the management of some patients with AD who have metal sensitivity.

Administration, Oral↗

Predicting metals sensed by ArsR-SmtB repressors: allosteric interference by a non-effector metal.

Many bacterial genomes encode multiple metal-sensing ArsR-SmtB transcriptional repressors. There is interest in understanding and predicting their metal specificities. Here we analyse two arsR-smtB genes, ydeT and yozA (now aseR and czrA) from Bacillus subtilis. Purified AseR and CzrA formed complexes in gel-retardation and fluorescence-anisotropy assays with fragments of promoters that were derepressed in DeltaaseR and DeltaczrA cells. Candidate (i) partly thiolate, alpha3-helix (for AseR) and (ii) tetrahedral, non-thiolate, alpha5-helix (for CzrA) metal binding sites were predicted then tested in vitro and/or in vivo. The precedents are for such sites to sense arsenite/antimonite (alpha3) and zinc (alpha5). This correlated with the respective metal inducers of AseR and CzrA repressed promoters in B. subtilis and matched the metals that impaired formation of protein-DNA complexes in vitro. The putative sensory sites of 1024 ArsR-SmtB homologues are reported. Although AseR did not sense zinc in vivo, it bound zinc in vitro exploiting alpha3 thiols, but AseR DNA binding was not impaired by zinc. If selectivity relies on discriminatory triggering of allostery not just selective metal binding, then tight non-effector metal complexes could theoretically inhibit metal sensing. AseR remained arsenite-sensitive in equimolar zinc, while CzrA remained zinc-sensitive in equimolar arsenite in vitro. However, cupric ions did not impair CzrA-DNA complex formation but did inhibit zinc-mediated allostery in vitro and prevent zinc binding. Access to copper must be controlled in vivo to avoid formation of cupric CzrA.

Allosteric Regulation↗

The use of a metal detector to locate ingested metallic foreign bodies in children.

OBJECTIVE: A pilot study to assess whether modern metal detectors can reduce unnecessary radiation in searching for ingested metallic foreign bodies. METHODS: Over a one year period, 20 children presenting to an accident and emergency department with suspected metallic foreign body ingestion were studied. Using an Adams Electronics AD15 metal detector, the radiographer recorded the location of metallic foreign bodies on a pictorial representation of neck, chest, and abdomen. The child then had plain radiographs of abdomen, chest, and neck in sequential order until the foreign body was located. RESULTS: In seven cases neither metal detector nor radiography revealed a foreign body (true negatives). In the remaining 13 cases where metal detection was positive, subsequent radiography or faecal search was also positive (true positives). The 13 foreign bodies were coins (8), gold ring (1), ball bearing (1), screw (1), staple (1), and washer (1). All were in the stomach or proximal small bowel on radiography except for one coin in the right iliac fossa. CONCLUSIONS: The detector can demonstrate ingested metallic foreign bodies reliably in children, thereby reducing unnecessary irradiation.

Child↗

The influence of occupational exposure to pesticides, polycyclic aromatic hydrocarbons, diesel exhaust, metal dust, metal fumes, and mineral oil on prostate cancer: a prospective cohort study.

AIMS: To investigate the relation between exposure to pesticides, polycyclic aromatic hydrocarbons (PAHs), diesel exhaust, metal dust, metal fumes, and mineral oil in relation to prostate cancer incidence in a large prospective study. METHODS: This cohort study was conducted among 58,279 men in the Netherlands. In September 1986, cohort members (55-69 years) completed a self-administered questionnaire on potential cancer risk factors, including job history. Follow up for prostate cancer incidence was established by linkage to cancer registries until December 1995 (9.3 years of follow up). The analyses included 1386 cases of prostate cancer and 2335 subcohort members. A blinded case-by-case expert exposure assessment was carried out to assign cases and subcohort members a cumulative probability of exposure for each potential carcinogenic exposure. RESULTS: In multivariate analyses there was a significant negative association for pesticides (RR 0.60; 95% CI 0.37 to 0.95) when comparing the highest tertile of exposure to pesticides with no exposure. No association was found for occupational exposure to PAHs (RR 0.75; 95% CI 0.42 to 1.31), diesel exhaust (RR 0.81; 95% CI 0.62 to 1.06), metal dust (RR 1.01; 95% CI 0.72 to 1.40), metal fumes (RR 1.11; 95% CI 0.80 to 1.54), or mineral oil (RR 0.99; 95% CI 0.66 to 1.48) when comparing the highest tertile of exposure with no exposure. In subgroup analysis, with respect to tumour invasiveness and morphology, null results were found for occupational exposure to pesticides, PAH, diesel exhaust, metal dust, metal fumes, and mineral oil. CONCLUSIONS: These results suggest a negative association between occupational exposure to pesticides and prostate cancer. For other carcinogenic exposures results suggest no association between occupational exposure to PAHs, diesel exhaust, metal dust, metal fumes, or mineral oil and prostate cancer.

Air Pollutants, Occupational↗

The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.

It has been found that a remarkable reduction in the wear of metal-on-metal hip joints can be achieved by simply increasing the diameter of the joint. A tribological evaluation of metal-on-metal joints of 16, 22.225, 28 and 36 mm diameter was conducted in 25 per cent bovine serum using a hip joint simulator. The joints were subject to dynamic motion and loading cycles simulating walking for both lubrication and wear studies. For each size of joint in the lubrication study, an electrical resistivity technique was used to detect the extent of surface separation through a complete walking cycle. Wear of each size of joint was measured gravimetrically in wear tests of at least 2 x 10(6) cycles duration. Joints of 16 and 22.225 mm diameter showed no surface separation in the lubrication study. This suggested that wear would be proportional to the sliding distance and hence joint size in this boundary lubrication regime. A 28 mm diameter joint showed only limited evidence of surface separation suggesting that these joints were operating in a mixed lubrication regime. A 36 mm diameter joint showed surface separation for considerable parts of each walking cycle and hence evidence of the formation of a protective lubricating film. Wear testing of 16 and 22.225 mm diameter metal-on-metal joints gave mean wear rates of 4.85 and 6.30 mm3/10(6) cycles respectively. The ratio of these wear rates, 0.77, is approximately the same as the joint diameters ratio, 16/22.225 or 0.72, as expected from simple wear theory for dry or boundary lubrication conditions. No bedding-in was observed with these smaller diameter joints. For the 28 mm diameter joint, from 0 to 2 x 10(6) cycles, the mean wear rate was 1.62 mm3/10(6) cycles as the joints bedded-in. Following bedding-in, from 2.0 x 10(6) to 4.7 x 10(6) cycles, the wear rate was 0.54 mm3/10(6) cycles. As reported previously by Goldsmith et al. in 2000 [1], the mean steady state wear rate of the 36 mm diameter joints was lower than those of all the other diameters at 0.07 mm3/10(6) cycles. For a range of joints of various diameters, subjected to identical test conditions, mean wear rates differed by almost two orders of magnitude. This study has demonstrated that the application of sound tribological principles to prosthetic design can reduce the wear of metal-on-metal joints, using currently available materials, to a negligible level.

Arthroplasty, Replacement, Hip↗

Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.

An elastohydrodynamic lubrication (EHL) analysis was carried out in this study for a typical McKee-Farrar metal-on-metal hip prosthesis under a simple steady state rotation. The finite element method was used initially to investigate the effect of the cement and bone on the predicted contact pressure distribution between the two articulating surfaces under dry conditions, and subsequently to determine the elastic deformation of both the femoral and the acetabular components required for the lubrication analysis. Both Reynolds equation and the elasticity equation were coupled and solved numerically using the finite difference method. Important features in reducing contact stresses and promoting fluid-film lubrication associated with the McKee-Farrar metal-on-metal hip implant were identified as the large femoral head and the thin acetabular cup. For the typical McKee-Farrar metal-on-metal hip prosthesis considered under typical walking conditions, an increase in the femoral head radius from 14 to 17.4 mm (for a fixed radial clearance of 79 microm) was shown to result in a 25 per cent decrease in the maximum dry contact pressure and a 60 per cent increase in the predicted minimum film thickness. Furthermore, the predicted maximum contact pressure considering both the cement and the bone was found to be decreased by about 80 per cent, while the minimum film thickness was predicted to be increased by 50 per cent. Despite a significant increase in the predicted minimum lubricating film thickness due to the large femoral head and the thin acetabular cup, a mixed lubrication regime was predicted for the McKee-Farrar metal-on-metal hip implant under estimated in vivo steady state walking conditions, depending on the surface roughness of the bearing surfaces. This clearly demonstrated the important influences of the material, design and manufacturing parameters on the tribological performance of these hard-on-hard hip prostheses. Furthermore, in the present contact mechanics analysis, the significant increase in the elasticity due to the relatively thin acetabular cup was not found to cause equatorial contact and gripping of the ball.

Acetabulum↗

Development and problems of metal-on-metal hip arthroplasty.

For over 40 years, the metal-on-polyethylene bearing has dominated the field of total hip replacement. Problems of wear, osteolysis (dissolution of bone), and ultimately failure of prostheses have led to the development of alternative bearing surfaces. Metal-on-metal hip resurfacing has taken current orthopaedic surgery almost by storm. However, metal ion release following metal-on-metal hip resurfacing remains a major cause for concern. This article looks into the development and examines problems and issues surrounding metal-on-metal resurfacing arthroplasty.

Bone Neoplasms↗

Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants.

Metal-metal hip implants have been used clinically in Europe to reduce the risk of wear particle induced osteolysis. Joint simulator devices could provide useful information for design improvement of the modern generation of metal-metal hip implants. Early wear results for metal-metal hip specimens were obtained using a MATCO hip simulator. A detailed kinematic analysis was developed for the MATCO simulator and applied to two of the wear experiments to predict the starting surface motion, contact zone and lubricant film thickness. It was shown that points on cup surfaces were not subjected to a reciprocating interaction with the head during wear at the beginning of testing but as wear proceeded, it was suggested that, in some cases, reciprocating interaction did occur on the cup surface. Comparison between simulator and in vivo kinematics suggested a more realistic representation for cup than for head wear. In the simulator, the Hertzian contact zone moved in a circular path over the cup surface and changed in size in correspondence with the applied load. Elastohydrodynamic lubrication was considered to be possible in the simulator, with estimated fluid film thickness as great as 0.1 micron. However, such thick films were not likely to have occurred at the start of the two wear tests which were examined in detail, although some mixed film lubrication might have accounted for the relatively low wear of one of the specimens. The inclusion of kinematic details, contact mechanics and elastohydrodynamic lubrication analysis in simulator testing protocols and in design of metal metal hip implants was recommended.

Elasticity↗

Using metal-ligand binding characteristics to predict metal toxicity: quantitative ion character-activity relationships (QICARs).

Ecological risk assessment can be enhanced with predictive models for metal toxicity. Modelings of published data were done under the simplifying assumption that intermetal trends in toxicity reflect relative metal-ligand complex stabilities. This idea has been invoked successfully since 1904 but has yet to be applied widely in quantitative ecotoxicology. Intermetal trends in toxicity were successfully modeled with ion characteristics reflecting metal binding to ligands for a wide range of effects. Most models were useful for predictive purposes based on an F-ratio criterion and cross-validation, but anomalous predictions did occur if speciation was ignored. In general, models for metals with the same valence (i.e., divalent metals) were better than those combining mono-, di-, and trivalent metals. The softness parameter (sigma p) and the absolute value of the log of the first hydrolysis constant ([symbol: see text] log KOH [symbol: see text]) were especially useful in model construction. Also, delta E0 contributed substantially to several of the two-variable models. In contrast, quantitative attempts to predict metal interactions in binary mixtures based on metal-ligand complex stabilities were not successful.

Algorithms↗

Analysis of 118 second-generation metal-on-metal retrieved hip implants.

Osteolysis is due to particulate wear debris and is responsible for the long-term failure of total hip replacements. It has stimulated the development of alternative joint surfaces such as metal-on-metal or ceramic-on-ceramic implants. Since 1988 the second-generation metal-on-metal implant Metasul has been used in over 60 000 hips. Analysis of 118 retrieved specimens of the head or cup showed rates of wear of approximately 25 microm for the whole articulation per year in the first year, decreasing to about 5 microm per year after the third. Metal surfaces have a 'self-polishing' capacity. Scratches are worn out by further joint movement. Volumetric wear was decreased some 60-fold compared with that of metal-on-polyethylene implants, suggesting that second-generation metal-on-metal prostheses may considerably reduce osteolysis.

Arthroplasty, Replacement, Hip↗

Metallic dental material biocompatibility in osteoblastlike cells: correlation with metal ion release.

Ions released from metallic dental materials used in orthodontic appliances could induce undesirable effects on cells and tissues. This study evaluates the biocompatibility of two of the most labile components of metallic dental alloys on osteoblastlike cells. The influence of protein and ions on metal dissolution properties is also investigated using different electrolyte solutions. Morphological alterations, cell growth, and differentiation of osteoblasts were assessed after exposure to pure metals (Ag, Cu, Pd, Au) and Ni-Ti alloy and correlated with the kinetics of elements released into the culture media. Results showed that Cu and Ag were the most cytotoxic elements and the other metals were biocompatible with the osteoblasts. The parameters of biocompatibility were correlated with the levels of ions detected into the culture media. Metal ions induced cell death through early mitosis arrest, apoptotic phenomena, and necrotic processes. Voltammograms showed that anions and proteins interfered in the corrosion process. Fetal bovine serum (FBS) strongly affected the electrochemical process, decreasing the oxidation rate of the metals. In conclusion, copper and silver ions showed a time-dependent low biocompatibility, which correlated with the concentration of released ions. The dissolution of the metallic materials was dependent on the composition of the simulated biological media.

Animals↗

Bioaccumulation of metals in Eisenia fetida after exposure to a metal-loaded bauxsol reagent.

The present study investigated the acute toxic effects of a metal-loaded Bauxsol reagent (MLBR), containing more than 6,450 mg kg(-1) of bound metal, on the earthworm Eisenia fetida. Bauxsol is manufactured by Virotec Global Solutions of Gold Coast, Queensland, Australia. The E. fetida were exposed to 0, 10, 20, 40, 60, and 80% treatments of MLBR plus cow manure for 28 d. Good motility and no mortality of E. fetida were found in all treatments after 28 d of exposure. The greatest bioaccumulation of metals by E. fetida occurred in the 20 and 40% MLBR treatments. The bioaccumulation of metals in the worms and bioaccumulation factors (BAFs) were less than the reported toxicity thresholds to cause mortality and less than the reported BAF for moderately contaminated soils, indicating that metals bound to Bauxsol reagents are mostly nonbioavailable. Analyses of the 20% MLBR treatment at 28 d using a sequential extraction procedure showed that more than 95% of the metals are bound within the Fe/Mn oxide fractions. However, changes occurred in metal fractionation after exposure to E. fetida for Cd/Cr, and Fe/Mn. The data also showed that the exchangeable (1 M MgCl2) and the toxicity characteristic leaching procedure extractant are useful as indicators of metal bioavailability from MLBR to E. fetida.

Aluminum↗

Silica gel modified with N-(3-propyl)-O-phenylenediamine: functionalization, metal sorption equilibrium studies and application to metal enrichment prior to determination by flame atomic absorption spectrometry.

The use of the chemically modified silica gel N-(3-propyl)-O-phenylenediamine (SiG-NPPDA) adsorbent, for the preconcentration and separation of trace heavy metals, was described. SiG-NPPDA sorbs quantitatively (90-100% recovery) trace amounts of nine heavy metals, viz., Cd(II), Zn(II), Fe(III), Cu(II), Pb(II), Mn(II), Cr(III), Co(II) and Ni(II) at pH 7-8. The sorption capacity varies from 350 to 450 micromol g(-1). Desorption was found to be quantitative with 1-2 M HNO3 or 0.05 M Na2EDTA. The distribution coefficient, Kd and the percentage concentration of the investigated metal ions on the adsorbent at equilibrium, C(M,eqm)% (Recovery, R%), were studied as a function of experimental parameters. The logarithmic values of the distribution coefficient, log Kd, ranges between 4.0 and 6.4. Some foreign ions caused little interference in the preconcentration and determination of the investigated nine metals by flame atomic absorption spectrometry (AAS). The adsorbent and its formed metal chelates were characterized by IR (absorbance and/or reflectance), potentiometric titrations and thermogravimetric analysis (TGA and DTG). The mode of chelation between the SiG-NPPDA adsorbent and the investigated metal ions is proposed to be due to the reaction of the investigated metal ions with the two nitrogen atoms of the SiG-NPPDA adsorbent. The present adsorbent coupled with flame AAS has been used to enrich and determine the nine metal ions in natural aqueous systems and in certified reference materials (RSD < or = 5%). The copper, iron, manganese and zinc present in some pharmaceutical vitamin samples were also preconcentrated on SiG-NPPDA adsorbent and determined by flame AAS (RSD < or = 4.2%). Nanogram concentrations (0.07-0.14 ng ml(-1)) of Cd(II), Zn(II), Fe(III), Pb(II), Cr(III), Mn(II), Cu(II), Co(II) and Ni(II) can be determined reliably with a preconcentration factor of 100.

Flame Ionization↗