Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Determination of parabens in pharmaceutical formulations by solid-phase microextraction-ion mobility spectrometry.

Solid-phase microextraction (SPME) coupled with ion mobility spectrometry (IMS) was used for the detection and quantitation of 4-hydroxybenzoate preservatives, methylparaben, ethylparaben, propylparaben, and butylparaben, in commercial pharmaceutical products. For the first time, SPME-IMS is described for the simultaneous detection, separation, and quantitation of multiple analytes in complex matrixes. The parabens are extracted from the samples using SPME, and the analytes on the fiber are heated by the IMS desorber unit and vaporized into the drift tube. The four preservatives differing only by a methyl group were separated in less than 18 ms. The analytical procedure was optimized for fiber coating selection, extraction time, sample pH, sample volume, ionic strength, and IMS conditions. Separation characteristics such as resolution, theoretical plates, and drift times of the parabens were also evaluated based on the direct interfacing of SPME to IMS. The conditions were tested using six over-the-counter topical products containing various combinations of preservatives. Analysis of the samples by SPME-IMS using benzyl paraben as an internal standard yields good comparison to an HPLC method, thereby reinforcing the applicability of this technique as a method for routine analysis. Limits of detection were 10 ng/mL for methylparaben and ethylparaben and 5 ng/mL for propylparaben and butylparaben. Good linearity range and reproducibility of less than 8% were obtained.

Calibration↗

Biomimetic measurement of allelochemical dynamics in the rhizosphere.

Polydimethylsiloxane (PDMS) materials were used to quantify levels of the photosynthesis inhibitor sorgoleone in the undisturbed rhizosphere of sorghum plants. The materials used included stir bars coated with PDMS (stir bar sorptive extraction), technical grade optical fiber coated with a thin film of PDMS (matrix-solid phase microextraction), and PDMS tubing. PDMS tubing retained the most sorgoleone. As analyzed by high performance liquid chromatography, amounts of sorgoleone retained on the PDMS materials increased with time. Other materials tested (polyurethane foam plugs, C18 and Tenax disks, and resin capsules) proved less suitable, as they were subject to sometimes extensive penetration by fine root hairs. These results demonstrate the potential for PDMS-based materials to monitor the release of allelochemicals in the undisturbed rhizosphere of allelopathic plants. Unlike extraction procedures that recover all available compounds present in the soil, PDMS functions in a manner more analogous to plant roots in sorbing compounds from soil solution or root exudates. Information on chemical dynamics in the rhizosphere is crucial for evaluating specific hypotheses of allelopathic effects, understanding allelopathic mechanisms, and assessing the importance of allelopathic processes in plant communities.

Benzoquinones↗

Assay of stability, free and total concentration of chlorhexidine in saliva by solid phase microextraction.

This paper presents the development and application of a solid phase microextraction method for the full investigation of chlorhexidine interaction with saliva during a pharmacokinetic study: chemical stability, binding to proteins, free concentration, total concentration and kinetics of elimination after oral administration. Only 0.1 mL sample were needed for each time point and the concentration of salivary proteins was determined as well. It was shown that chlorhexidine remained stable in the oral cavity for at least 9 h and high concentrations of the drug (2 microg/mL total) were still present even 8 h after mouthrinsing. Supplementary facts were uncovered: while the total concentration followed first-order elimination kinetics, the free concentration remained almost constant for several hours; this showed that the oral cavity acted like a reservoir that slowly released the drug. It was also revealed that following oral administration of chlorhexidine, the normal composition of saliva changed for a few hours, probably as a physiological response to the bitter taste of the medicine. The method had a wide linear range (0.1-40 microg/mL free chlorhexidine) that was perfectly suitable for the study of chlorhexidine retention in the oral cavity. Separation and quantitation were achieved by liquid chromatography coupled to mass spectrometry; no interference from endogenous compounds was observed. This selective and sensitive solid-phase microextraction (SPME) approach for monitoring the free and total concentration of a drug, as well as the concentration of proteins that bind that drug, should prove to be more useful for pharmacokinetic studies than classic methods that only provide the total concentration as a final result.

Chlorhexidine↗

Time dependence of phase distribution of pyrethroid insecticides in sediment.

Synthetic pyrethroids are strongly hydrophobic compounds, and their toxicity in sediment is regulated by phase distribution among the sediment, dissolved organic matter, and water phases. In the present study, we spiked and equilibrated four pyrethroids in two sediments, and we characterized their phase distribution as a function of contact time. The freely dissolved concentration measured by solid-phase microextraction was only a small fraction (<16.3%) of the total pore-water concentration as determined by liquid-liquid extraction. The fraction of the freely dissolved concentration was significantly greater in the freshwater sediment (1.7-16.3%) than in the marine sediment (1.1-4.2%) following 9 d of equilibration, and it decreased substantially with contact time to less than 5% at 30 d after sediment dosing. Consequently, the apparent organic carbon partition coefficient (Koc) and dissolved organic carbon partition coefficient (Kdoc) values increased significantly over the contact time, especially in the freshwater sediment, suggesting that phase distribution was not at equilibrium after 9 d of equilibration. If only the freely dissolved concentration is bioavailable, these observations suggest that contact time after sediment dosing may greatly affect the bioavailability and, hence, the toxicity of pyrethroids. Therefore, a long contact time (> or = 30 d) is recommended for sediment toxicity testing of this class of compounds. The dependence of bioavailability on contact time also implies that test conditions must be standardized to allow comparison between laboratory-dosed samples and field samples.

Carbon↗

Solid-phase microextraction for quantitative analysis of organophosphorus pesticides in environmental water samples.

Solid-phase microextraction (SPME) is a relatively new technique that appears as a convenient and efficient extraction method in contrast with more complex techniques used for pesticide residue analysis based on liquid-liquid and solid-phase extraction. This extraction procedure involves the absorption of analytes into a polymeric film coated onto a fine silica fiber directly dipped in the aqueous sample. An SPME procedure for the determination of 12 organophosphorus pesticides in clean environmental water samples at low ng/ml concentration level has been developed by optimising variables involved in extraction and desorption. The absorption equilibrium has been estimated by mathematical treatment of the process using an expression that describes experimental absorption time profiles. The method was evaluated according to the reproducibility, linearity range and limits of detection using two different fiber coatings: 100 microm polydimethylsiloxane and 85 microm polyacrylate. The limits of detection obtained using nitrogen-phosphorus detection ranged between 0.01 and 0.2 ng/ml with relative standard deviations lower than 15% at the 1 ng/ml level. The method showed good linearity between 0.1 and 10 ng/ml with regression coefficients ranging between 0.97 and 0.999. Determination of organophosphorus pesticides in water samples in concentration below 0.1 ng/ml can be easily carried out with this fast, economic and solvent-free SPME procedure.

Adsorption↗

Development of a solid-phase microextraction method with micellar desorption for the determination of chlorophenols in water samples. Comparison with conventional solid-phase microextraction method.

A novel analytical method is presented for the determination of chlorophenols in water. This method involves pre-concentration by solid-phase microextraction (SPME) and an external desorption using a micellar medium as desorbing agent. Final analysis of the selected chlorophenols compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detection (DAD). Optimum conditions for desorption, using the non-ionic surfactant polyoxyethylene 10 lauryl ether (POLE), such as surfactant concentration and time were studied. A satisfactory reproducibility for the extraction of target compounds, between 6 and 15%, was obtained, and detection limits were in the range of 1.1-5.9ngmL(-1). The developed method is evaluated and compared with the conventional one using organic solvent as a desorbing agent. The method was successfully applied to the determination of chlorophenols in water samples from different origin. This study has demonstrated that solid-phase microextraction with micellar desorption (SPME-MD) can be used as an alternative to conventional SPME method for the extraction of chlorophenols in water samples.

Chlorophenols↗

New trends in hair analysis and scientific demands on validation and technical notes.

This review focuses on basic aspects of method development and validation of hair testing procedures. Quality assurance is a major issue in drug testing in hair resulting in new recommendations, validation procedures and inter-laboratory comparisons. Furthermore recent trends in research concerning hair analysis are discussed, namely mechanisms of drug incorporation and retention, novel analytical procedures (especially ones using liquid chromatography-mass spectrometry (LC-MS) and alternative sample preparation techniques like solid-phase microextraction (SPME)), the determination of THC-COOH in hair samples, hair testing in drug-facilitated crimes, enantioselective hair testing procedures and the importance of hair analysis in clinical trials. Hair testing in analytical toxicology is still an area in need of further research.

Forensic Toxicology↗

Liquid-phase micro-extraction techniques in pesticide residue analysis.

Modern trends in analytical chemistry are towards the simplification and miniaturization of sample preparation, as well as the minimization of organic solvent used. In view of this aspect, several novel micro-extraction techniques are being developed in order to reduce the analysis step, increase the sample throughput and to improve the quality and the sensitivity of analytical methods. One of the emerging techniques in this area is liquid-phase micro-extraction (LPME). It is a miniaturized implementation of conventional liquid/liquid extraction (LLE) in which only microliters of solvents are used instead of several hundred milliliters in LLE. It is quick, inexpensive and can be automated. In the last few years, LPME has been combined with liquid chromatography (LC) and capillary electrophoresis (CE), besides the generally used coupling to gas chromatography (GC), and has been applied to various matrices, including biological, environmental, and food samples. This work is aimed at providing an overview of the major developments of LPME, coupled with chromatography and CE, as reported in the literature. The paper will focus on the application of the technique to different matrices and the aim is to reveal the panorama of opportunities and to try to indicate the potential of LPME in pesticide analysis. A critical review of the first applications to pesticide analyses is presented in the main part of the manuscript. The optimization of LPME as well as advantages and disadvantages are discussed. It is concluded that, because of its high pre-concentration factor, LPME can be introduced with benefit into water analysis for several pesticide groups. In particular, the application of LPME to non-polar pesticides in environmental analysis appears to be promising. However, similar to other micro-extraction techniques, such as solid phase micro-extraction (SPME), serious limitations still remain when analyzing semi-solid and solid environmental, food or biological matrices and/or highly polar compounds. Thus, other pre-concentration techniques may be a good alternative if an analytical problem cannot be sufficiently dealt with LPME.

Chromatography, Liquid↗

Evaluation of the antimicrobial activity of citrus essences on Saccharomyces cerevisiae.

The aim of this research was to assess the antimicrobial activity of nine different industrial essences used in a soft drink factory in relation to their composition, as well as to verify the role of vapor pressure on their bioactivity. The essences were tested against a Saccharomyces cerevisiae strain isolated from spoiled soft drinks. The tests were carried out by adding the essences directly to a liquid medium or into the headspace of closed systems inoculated with the yeast. The headspace composition was evaluated through a solid phase microextraction-gas chromatography technique. The use of a mass spectrometer allowed the identification of the peaks detected. The microbial growth was indirectly monitored by measuring the metabolic CO2 released by the yeast. The results obtained indicated that the most effective essences were characterized by the highest concentration of some terpenes, such as citral, beta-pinene, and p-cymene. Moreover, all of the essences were more bioactive when added directly to the liquid medium.

Citrus↗

ASTM standards for fire debris analysis: a review.

The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved. Fire debris analysts that use the standards should be aware of these changes.

Journal Article↗

Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urine.

A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.

Chromatography, High Pressure Liquid↗

New high-performance cryofocalizer injector for in-tube solid-phase microextraction and headspace capillary gas chromatographic applications.

The construction of a high-efficiency but cheap injector for volatile and very volatile compounds is shown. The device focuses the compounds in a fused-silica (FS) transfer capillary with the aid of liquid nitrogen. A 6.2 mm O.D. glass tube liner (ca. 25 cm x 1.5 mm I.D.) is inserted in the heated (-200 degrees C) injector of the gas chromatograph in place of the standard glass liner, and extends further externally through a liquid nitrogen container made with styrofoam-like material. Inside this glass tube, the FS transfer line passing through the oven door is connected like a pre-column to the analytical high-resolution GC column. It can move fast between the heated and the cooled zone (<-->, deltaL = 13 cm), and when this movement starts, crvofocused analytes are injected "at once" resulting in symmetrical and sharp injection bands with "zero" carryover. The performance of this device is demonstrated by its application to in-tube solid-phase microextraction and to spice volatiles analysis.

Chromatography, Gas↗

Liquid-liquid-liquid microextraction of aromatic amines from water samples combined with high-performance liquid chromatography.

A simple preconcentration and clean-up liquid-liquid-liquid microextraction of aromatic amines is described in this paper. The compounds were extracted from 2.0 ml aqueous samples (donor phase) into an organic phase, layered on the donor phase, and then back extracted to a microdrop of aqueous receiving phase, suspended in the organic phase. After extraction, the microdrop was injected into the HPLC system directly for analysis. Optimal conditions of the extraction were donor phase (a1): 2 ml of water sample adjusted to pH 13 with NaOH-NaCl; organic phase (o), 150 microl ethyl acetate; and receiving phase (a2) of 2 microl aqueous solution at pH 2.1. The a1-->o extraction time was 15 min and for o-->a2, 30 s. 18-Crown-6 ether, which can complex with amine, was added to the aqueous receiving phase to improve the extraction performance. Enrichment factors ranged from 218 (for 4-nitroaniline) to 378 (for 4-chloro-2-aniline). The calibration curve for these anilines was linear within the range 2.5 ng/ml-2.5 microg/ml (r2=0.998). Detection limits ranged from 0.85 to 1.80 ng/mi (at S/N=3). This procedure can be a selective preconcentration method for aromatic amines present in water samples.

Amines↗

Evaluation of solid-phase microextraction for the isotopic analysis of volatile compounds produced during fermentation by lactic acid bacteria.

The use of solid-phase microextraction (SPME) coupled with isotope ratio mass spectrometry (IRMS) for the analysis of flavor compounds produced by lactic acid bacteria has been evaluated using both liquid and headspace sampling modes. Initially, it was necessary to optimize the conditions for the SPME extraction of flavors-diacetyl and acetoin-in standard aqueous solutions. The effects of salt, headspace versus liquid sampling, and coating phase were tested. Second, the suitability of the coupling of SPME and gas chromatography-combustion interface-IRMS (GC-C-IRMS) for the determination of delta(13)C values was assessed. It is shown that neither the analyte concentration nor the period of fiber exposure has an effect on the delta(13)C values. Finally, having verified that there are no matrix effects from the fermentation medium, it is reported for the first time that flavor compounds can be extracted directly from culture supernatant by SPME and their delta(13)C values can be obtained by GC-C-IRMS.

Acetoin↗

Detection of the cyclic nitramine explosives hexahydro-1,3,5-trinitro- 1,3,5-triazine (RDX) and octahydro- 1,3,5,7-tetranitro- 1,3,5,7-tetrazine (HMX) and their degradation products in soil environments.

The cyclic nitramine explosives hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX) were examined in field and microcosm soil samples to determine their patterns of degradation and environmental fates. A number of analytical techniques, including solid-phase microextraction with on-fiber derivatization, gas chromatography-mass spectrometry, gas chromatography with electron-capture detection, liquid chromatography-mass spectrometry, and micellar electrokinetic chromatography were required for the analyses. Two different classes of intermediates were detected, both of which lead ultimately to the formation of nitrous oxide (N2O) and carbon dioxide (CO2). The first class was identified as the nitroso derivatives formed by the sequential reduction of -NO2 functional groups. The second class of intermediates, which was favored at higher humidities and in the presence of anaerobic sludge amendments, consisted of ring cleavage products including bis-(hydroxymethyl)-nitramine and methylenedinitramine. Rye-grass (Lolium perenne) present in field samples was found to extract and accumulate HMX from soil without further degradation. In all cases (excepting the plant samples), the indigenous microbes or amended domestic anaerobic sludge consortia degraded the cyclic nitramine explosives eventually to produce N2O and CO2.

Azocines↗

[Developments in preparation and experimental method of solid phase microextraction fibers].

Solid phase microextraction (SPME) is a simple and effective adsorption and desorption technique, which concentrates volatile or nonvolatile compounds from liquid samples or headspace of samples. SPME is compatible with analyte separation and detection by gas chromatography, high performance liquid chromatography, and other instrumental methods. It can provide many advantages, such as wide linear scale, low solvent and sample consumption, short analytical times, low detection limits, simple apparatus, and so on. The theory of SPME is introduced, which includes equilibrium theory and non-equilibrium theory. The novel development of fiber preparation methods and relative experimental techniques are discussed. In addition to commercial fiber preparation, different newly developed fabrication techniques, such as sol-gel, electronic deposition, carbon-base adsorption, high-temperature epoxy immobilization, are presented. Effects of extraction modes, selection of fiber coating, optimization of operating conditions, method sensitivity and precision, and systematical automation, are taken into considerations in the analytical process of SPME. A simple perspective of SPME is proposed at last.

Chromatography, Gas↗

Molecularly imprinted polymers for solid-phase extraction and solid-phase microextraction: recent developments and future trends.

Molecularly imprinted polymers (MIPs) are synthetic polymers having a predetermined selectivity for a given analyte, or group of structurally related compounds, that make them ideal materials to be used in separation processes. In this sense, during past years a huge amount of papers have been published dealing with the use of MIPs as sorbents in solid-phase extraction, namely molecularly imprinted solid-phase extraction (MISPE). Although the majority of these papers were restricted to describe the use of different templates for different applications, several attempts proposing new alternatives to minimize the inherent drawbacks of the preparation and use of MIPs (i.e. template bleeding, tedious synthesis procedure, etc.) have been reported. Thus, this paper does not pretend to be a collection of MISPE-related papers but to give an overview on the significant attempts carried out during recent years to improve the performance of MIPs in solid-phase extraction. In addition, the use of MIPs packed in high performance liquid chromatography (HPLC) columns for the direct injection of crude sample extracts and the preparation of imprinted fibres for solid-phase microextraction will be also discussed.

Combinatorial Chemistry Techniques↗

Comparison of strategies for extraction of high molecular weight polycyclic aromatic hydrocarbons from drinking waters.

Simple, rapid, and inexpensive methods have been developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in drinking waters without interferences from other chemical contaminants by use of two different extraction techniques and analysis by an optimized reverse-phase (RP) high-performance liquid chromatography followed by fluorescence detection (HPLC-FLD) method. The feasibility of SPE (solid-phase extraction) and SPME (solid-phase microextraction) for the determination of PAH in drinking water samples has been evaluated. Several parameters have been studied and optimized for both extraction procedures. The relationship between the nature of the fibers and the quantity of extracted compounds and the effects of organic solvent, salt addition, sampling temperature, and sampling time was studied for SPME. Acetonitrile percentage added to the sample, sample storage conditions (temperature and time), and type of organic elution solvent and elution volume were evaluated for SPE. The results show that both extraction procedures can be used to determine PAHs in drinking waters, but SPE gives better performance (recovery, precision, and quantification limits) for the determination of PAHs in drinking water at the levels established by the legislation.

Chromatography, High Pressure Liquid↗