Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Lasers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema.

AIM: To correlate change of an oedema index derived by scanning laser tomography with change of visual function in patients undergoing grid laser photocoagulation for clinically significant diabetic macular oedema (DMO). METHODS: The sample comprised 24 diabetic patients with retinal thickening within 500 micro m of the fovea. Inclusion criteria included a logMAR visual acuity of 0.25, or better. Patients were assessed twice before a single session of grid laser treatment and within 1 week of, and at 1, 2, 4, and 12 weeks after, treatment. At each visit, patients underwent logMAR visual acuity, conventional and short wavelength automated perimetry (SWAP), and scanning laser tomography. Each visual function parameter was correlated with the mean oedema index. The mean oedema index represented the z-profile signal width divided by the maximum reflectance intensity (arbitrary units). A Pearson correlation coefficient (Bonferroni corrected) was undertaken on the data set of each patient. RESULTS: 13 patients exhibited significant correlation of the mean oedema index and at least one measure of visual function for the 10 degrees x 10 degrees scan field while 10 patients correlated for the 20 degrees x 20 degrees scan field. Seven patients demonstrated correlation for both scan fields. Laser photocoagulation typically resulted in an immediate loss of perimetric sensitivity whereas the oedema index changed over a period of weeks. Localised oedema did not impact upon visual acuity or letter contrast sensitivity when situated extrafoveally. CONCLUSIONS: Correlation of change of the oedema index and of visual function following grid laser photocoagulation was not found in all patients. An absence of correlation can be explained by the localised distribution of DMO in this sample of patients, as well as by differences in the time course of change of the oedema index and visual function. The study has objectively documented change in the magnitude and distribution of DMO following grid laser treatment and has established the relation of this change to the change in visual function.

Aged↗

Evaluation of port wine stains by laser Doppler perfusion imaging and reflectance photometry before and after pulsed dye laser treatment.

Treatment of choice for congenital capillary malformations of the port wine stain type is presently the pulsed dye laser. Although treatment results have usually been excellent or good, a few patients respond less well. Looking for a tool to predict and monitor the treatment we used laser Doppler perfusion imaging and reflectance photometry. Measurements with laser Doppler perfusion imaging were performed in 19 patients initially and after 1-3 treatments and with reflectance photometry initially and after 1-6 treatments. Before treatment, 15 of the patients had an increased bloodflow within the port wine stain in comparison with normal contralateral skin. After the laser treatments, 15 of 18 patients had decreased bloodflow within the lesion and all 18 had surrounding hyperemia. Reflectance photometry showed a successive increase in blanching and predicted within 6 weeks of the first treatment the eventual clinical result. The bloodflow, as measured with laser Doppler perfusion imaging, did not correlate well with the photometrically registered erythema. Reflectance photometry is a useful objective tool, which early in the treatment course indicates whether laser therapy will be successful. Laser Doppler perfusion imaging is less helpful in monitoring patients but may be of use in the study of port wine stain pathophysiology.

Adolescent↗

A study of cavity preparation by Er:YAG laser--observation of hard tooth structures by laser scanning microscope and examination of the time necessary to remove caries.

The purpose of this study was to observe and measure the morphological changes that occur in the hard tissue after the application of Er:YAG laser. Another objective was to evaluate and compare the duration of application of both the laser apparatus and a conventional cutting device. In this study, sound and newly extracted carious tissues were used. The morphological changes in hard tooth structures produced by Er:YAG laser irradiation were examined by using a laser scanning microscope. Results showed that appropriate laser irradiation was 100 mJ/pulse for dentin, and 200 mJ/pulse for enamel. Also, the laser scanning microscope images were less damaged than the SEM images due to pretreatment of the specimens. The time taken to remove carious enamel by laser irradiation was slightly longer than the compared rotary cutting device; however, no differences between the two methods were observed in case of carious dentin removal.

Aluminum Silicates↗

Laser surgery: using the carbon dioxide laser.

In 1917 Einstein theorized tha through an atomic process a unique kind of electromagnetic radiation could be produced by stimulated emission. When such radiation is in the optical or infrared spectrum it is termed laser (light amplification by stimulated emission of radiation) light. A laser, a high-intensity light source, emits a nearly parallel electromagnetic beam of energy at a given wavelength that can be captured by a lens and concentrated in the focal spot. The wavelength determines how the laser will be used. The carbon dioxide laser is now successfully employed for some surgical procedures in gynecology, otorhinolaryngology, neurosurgery, and plastic and general surgery. The CO2 laser beam is directed through the viewing system of an operating microscope or through a hand-held laser component. Its basic action in tissue is thermal vaporization; it causes minimal damage to adjacent tissues. Surgeons require special training in the basic methods and techniques of laser surgery, as well as in the safety standards that must be observed.

Humans↗

Effect of laser wavelength and protein solder concentration on acute tissue repair using laser welding: initial results in a canine ureter model.

Successful tissue approximation can be performed using low power laser energy combined with human albumin solder. In vitro studies were undertaken to investigate the acute repair strengths achieved using different laser wavelengths. Furthermore, we evaluated the change in repair strength with that resulted from changes in protein solder concentration. Intraluminal bursting pressure following ureterotomy repair was measured for the following laser wavelengths: 532, 808, 1,320, 2,100, and 10,600 nm. The tissue absorption characteristics of the 808-nm diode and the KTP-532-nm lasers required the addition of the exogenous chromophores indocyanine green and fluorescein, respectively. A 40% human albumin solder was incorporated in the repair of a 1.0-cm longitudinal defect in the canine ureter. Following determination of an optimal welding wavelength, human albumin solder of varying concentrations (25%, 38%, 45%, and 50%) were prepared and tested. The 1,320-nm YAG laser achieved the highest acute bursting pressure and was the most effective in this model. Of the concentrations of albumin tested, 50% human albumin yielded the greatest bursting pressures. We conclude that of the laser wavelengths evaluated, the 1,320-nm YAG achieves the strongest tissue weld in the acute ex vivo dog ureter model. In addition, when this laser system is used, the acute strength of a photothermal weld appears to be directly proportional to the concentration of human albumin solder in the range of 25 to 50%.

Albumins↗

Effect of pulse duration on bubble formation and laser-induced pressure waves during holmium laser ablation.

BACKGROUND AND OBJECTIVE: One concern during laser ablation of tissue is the mechanical injury that may be induced in tissue in the vicinity of the ablation site. This injury is primarily due to rapid bubble expansion and collapse or due to laser-induced pressure waves. In this study, the effect of laser pulse duration on the thermodynamics of bubble formation and accompanying acoustic pressure wave generation has been investigated. STUDY DESIGN/MATERIALS AND METHODS: Q-switched holmium:YAG laser pulses (pulse duration 500 ns, pulse energy 14 mJ) and free-running holmium:YAG laser pulses (pulse duration 100-1,100 microseconds, pulse energy 200 mJ) were delivered in water and tissue phantoms via a 200- and 400-microns fiber, respectively. The tissue phantoms consisted of polyacrylamide gels with varying mechanical strengths. Bubble formation was recorded with a fast flash photography setup, while acoustic transients were measured with a needle hydrophone. RESULTS: It was observed that, as the pulse length was increased the bubble shape changed from almost spherical for Q-switched pulses to a more elongated cylinder shape for longer pulse durations. The bubble expansion velocity was larger for shorter pulse durations. Only the Q-switched pulse induced a measurable thermo-elastic expansion wave. All pulses that induced bubble formation generated pressure waves upon collapse of the bubble in gels as well as in water. However, the magnitude of the pressure wave depended strongly on the size and geometry of the induced bubble. CONCLUSION: The magnitude of the collapse pressure wave decreased as laser pulse duration increased. Hence it may be possible to reduce collateral mechanical tissue damage by stretching the holmium laser pulse.

Acoustics↗

Comparative study of Nd:YAG laser angioplasty at 1.06 microns, 1.32 microns, and 1.44 microns wavelengths: decreased vascular spasm and early mortality with 1.44 microns laser ablation.

BACKGROUND AND OBJECTIVE: Although laser angioplasty has been demonstrated to be effective for the treatment of long, complex coronary arterial atherosclerotic stenoses, there is an associated risk of acute arterial spasm, dissection, and perforation as well as a significant restenosis rate. It has been postulated that the use of lasers emitting at wavelengths designed for radiation absorption by water would decrease local tissue trauma. STUDY DESIGN/MATERIALS AND METHODS: We have examined the use of a Nd:YAG laser designed to emit at 1.44 microns, an absorption peak for water, and compared the results of laser ablation at 1.06 microns, 1.32 microns, and 1.44 microns wavelengths. Nd:YAG laser angioplasty was performed in the abdominal aorta of White Leghorn roosters. Acute and chronic vascular trauma was assessed by contrast angiography and histological analysis. RESULTS: There was a significant decrease in early mortality with 1.44 microns laser ablation. This decreased mortality after 1.44 microns ablation was associated with a decrease in vascular spasm, perforation, and thermal damage. Atherosclerotic plaque development at follow up was decreased with 1.44 microns ablation but this was not significant. CONCLUSION: 1.44 microns laser ablation decreases early vascular trauma and mortality and may decrease subsequent atherosclerotic plaque development.

Angiography↗

Single-laser approach for fluorescence guidance of excimer laser angioplasty at 308 nm: evaluation in vitro and during coronary angioplasty.

BACKGROUND AND OBJECTIVE: Spectroscopic guidance of laser angioplasty has been attempted using a diagnostic He-Cd laser in addition to the therapeutic laser system. This study evaluated a single-laser approach for simultaneous ablation and fluorescence excitation. STUDY DESIGN/MATERIALS AND METHODS: A spectroscopy system was coupled to a clinical XeCl excimer laser. Ablation of 162 human aortic samples in saline and blood with 45 mJ/mm2 per pulse yielded 676 fluorescence spectra validated histologically. The same equipment was used in 16 patients for angioplasty of 18 coronary stenoses applying 500 to 1,725 pulses with 45 to 60 mJ/mm2 under saline flushing. A total of 783 spectra were recorded and validated by intracoronary ultrasound (categories: atheroma, fibrous plaque, calcified lesion). RESULTS: In vitro, 5 types of spectra could be differentiated: (1) atheroma, (2) fibrous plaque, (3) calcified lesion in saline, (4) media, and (5) calcified lesion in blood. Discriminant analysis prospectively classified 576 validation spectra with the following sensitivity and specificity for each type: (1) 83.5 and 97.1%, (2) 85.7 and 96.8% (3) 100 and 98.5%, (4) 98.1 and 99.3%, (5) 98.9 and 100%, respectively. In vivo type 1, 2, 3, and 5 spectra were also observed, but not the media spectrum. The predominant sonographic category also prevailed in spectroscopy. Calcified lesions yielded type 3 and 5 as well as mixed spectra. CONCLUSIONS: Using an excimer laser for angioplasty allows combining ablation and fluorescence excitation without a diagnostic laser. Principal types of atherosclerotic lesions and the media can be differentiated spectroscopically with this approach.

Adult↗

In vitro tissue effects of a combined Ho:YAG/Nd:YAG laser: sprinkling of tissue fragments by Ho:YAG laser light may be problematic for oncological interventions.

BACKGROUND AND OBJECTIVE: Surgery of soft tissue, for example, of the tongue or the liver, requires a cutting and coagulating device. Therefore, a combined Ho:YAG/Nd:YAG laser providing the laser beam of both systems together in one bare fiber seems to be useful. STUDY DESIGN/MATERIALS AND METHODS: We studied the effect of such a laser system in vitro on tongues of pigs. RESULTS: Combined application of both lasers results in vitro in a thicker coagulation zone in soft tissue (tongue). Tissue fragments possibly containing vital cells are sprinkled by the pulsed energy of the Ho:YAG laser up to a distance of 20 cm. CONCLUSION: Using the pulsed Ho:YAG laser for oncologic interventions seems to be problematic. Combined laser effect in vivo may result in better hemostasis.

Animals↗

Laser-tissue interaction with a high-power 2-microm fiber laser: preliminary studies with soft tissue.

BACKGROUND AND OBJECTIVE: Recent developments in fiber laser technology have introduced highly efficient, compact sources with high output beam quality. The first laser-tissue interaction studies with a high-power 2-microm fiber laser were conducted. STUDY DESIGN/MATERIALS AND METHODS: Chicken breast and porcine muscle tissue samples were subjected to continuous wave (cw) irradiation at 800-mW and 5-W output power levels, with spot sizes of approximately 150 microm. After laser irradiation, samples were inspected with an optical microscope and prepared for histologic processing. RESULTS: Evaluation of surface changes in tissue samples indicated an interaction similar in nature to those previously demonstrated with other cw lasers, but with photothermal ablation characteristics typical of strongly absorbed lasers operating in the infrared wavelength region. An ablation velocity of 0.27 mm.sec(-1) in porcine tissue was determined at 800-mW incident power. Histopathologic analysis demonstrated the formation of lesions with minimal damage at boundaries and no evidence of carbonization. CONCLUSIONS: Results indicate that this fiber laser has the potential to fulfill applications in the medical field.

Absorption↗

Effects of electrocautery, CO2 laser, and contact Nd:YAG laser scalpel on the healing of intestinal incision.

Leakage after intestinal resection is a serious complication with a high mortality rate. A recent study claims that cutting the intestine with the CO2 laser improves the healing of intestinal anastomoses (Ferulano et al: Eur Surg Res 16:127-130, 1984). The present study was undertaken to analyze the effects of electrocautery, CO2 laser, and contact Nd:YAG laser on the healing of intestinal incisions. Fifteen piglets were used and the cutting and reanastomosing were performed by using all cutting methods in each animal in randomized order. Resection sites were 50 cm, 100 cm, and 150 cm distal to the ligament of Treitz. On the seventh day the bursting pressures were measured for each anastomosis. They were 172 +/- 17 mmHg for normal bowel segment and 133 +/- 12, 135 +/- 40, and 139 +/- 17 mmHg for electrocautery, CO2 laser, and Nd:YAG laser, respectively. There were no mortality, no anastomotic leaks, and no statistically significant differences in the bursting pressures, in histology, or in the healing of anastomotic sites, indicating that electrocautery, CO2 laser, and contact Nd:YAG laser scalpel can safely be used in the surgery of small intestine.

Animals↗

Dependence of the XeCl laser cut rate of plaque on the degree of calcification, laser fluence, and optical pulse duration.

A XeCl laser with an optical pulse duration of 35 ns was used to determine the cut depth per laser pulse of postmortem human aorta as a function of laser fluence for four main categories of plaque development. The data indicate that the cut depth per pulse progressively decreases as the degree of calcification increases even at very high (100 mJ/mm2) laser fluences. A comparison was made between the XeCl laser cut rate data obtained using the 35-ns duration laser pulses to data obtained using 200-ns duration pulses for each of the four plaque types. As the degree of tissue calcification increased higher XeCl laser fluences were required for the long pulse case to achieve the same cut depth per pulse as that observed using the shorter pulse duration.

Angioplasty, Laser↗

Alternative lasers for endoscopic surgery: comparison of pulsed thulium-holmium-chromium:YAG with continuous-wave neodymium:YAG laser for ablation of colonic mucosa.

Precise and controllable tissue vaporization is essential for minimizing risk in removal of sessile polyps from the lumen of thin walled gastrointestinal organs such as the colon. We compared the ablative efficiency on canine colonic mucosa of the THC:YAG laser with the clinically employed cw Nd:YAG laser. Fresh canine colon was treated with a progressive dose schedule using each laser at several energy/power densities. Ablation depth was measured on fresh tissue and thermal (non-ablation or coagulative) damage examined histologically. The THC:YAG ablation rates were 13.7 +/- 0.8 and 10.2 +/- 0.4 microns/J at 55 and 85 J/cm2, respectively. The Nd:YAG laser generated 3.7 +/- 0.3, 2.8 +/- 0.1, and 3.6 +/- 0.2 microns/J at 4,460, 5,095, and 5,730 W/cm2, respectively. There was a significant (P less than 0.001) difference among the THC:YAG ablation rates and between the THC:YAG and Nd:YAG ablation rates (ANOVA). The THC:YAG laser craters had significantly less collateral thermal damage than Nd:YAG. The pulsed THC:YAG laser should have an important clinical role since its use could reduce the risk of perforation in endoscopic laser procedures such as the removal of sessile polyps.

Aluminum Silicates↗

Comparison of tissue effects with sculptured fiberoptic cables and other Nd:YAG laser and argon laser treatments.

The use of a fiber optic cable in contact with tissue results in a complex thermal interaction between the cable and the tissue. The effect of the laser-tissue interaction was investigated using sculptured quartz fiber optic cables, sapphire contact rods, and bare fiber optic cables attached to the Nd:YAG laser. The laser-tissue effects of the Nd:YAG and argon lasers were compared. Examination of treated animals showed there to be a significant difference between immediate and 48-hour thermal effects. The sculptured fibers created significantly less tissue damage than the sapphire contact tips, the 0.6-mm bare fiber, or the argon laser with a 0.3-mm bare fiber either with or without contact. All Nd:YAG laser contact treatments were less damaging than the argon laser treatments.

Abdominal Muscles↗

Erb:YAG and Hol:YAG laser osteotomy: the effect of laser ablation on bone healing.

Sixty-nine male Sprague Dawley rats were divided into three groups of 23 animals each and osteotomies were performed in group 1 with a power saw, in group 2 with the Erb:Yag laser, and in group 3 with the Hol:YAG laser. Two animals of each group were sacrificed 1 week, 4, 8, and 12 weeks after operation for histologic investigation, and five animals of each group at 4, 8, and 12 weeks after osteotomy for torque testing. Anterior-posterior (AP) radiographs were taken at the same time points and investigated for callus formation and development of pseudoarthrosis. All tibiae osteotomied with the Hol:YAG laser (group 3) developed pseudoarthrosis within 12 weeks and, therefore, torque testing could not be performed for this group. Biomechanical measurements of bone treated by power saw or Erb:YAG laser osteotomies, respectively, showed no significant statistical difference in the stability of bone between the two groups. Histologic examination after 1 week exhibited fibrous tissue at the site of osteotomy in rats of all three groups and additionally carbonization in rats of group 3. Saw osteotomies resulted in more callus formation than Erb:YAG osteotomies, but both techniques provoked a certain reunion within 8 weeks. Hol:YAG laser-treated osteotomies, however, exhibited formation of dense fibrous tissue, carbonization and no callus formation within 12 weeks. Radiographic pictures showed more callus formation for saw osteotomies as compared to those performed with the Erb:YAG laser. For Hol:YAG laser osteotomies pseudoarthrosis was identified also radiologically.

Aluminum Silicates↗

Thulium fiber laser lithotripsy: an in vitro analysis of stone fragmentation using a modulated 110-watt Thulium fiber laser at 1.94 microm.

BACKGROUND AND OBJECTIVES: The high-power Thulium fiber laser has previously been shown to rapidly vaporize and coagulate soft urinary tissues (e.g., prostate). This is the first preliminary study of a high-power Thulium fiber laser for fragmentation of urinary stones. STUDY DESIGN/MATERIALS AND METHODS: A continuous-wave, high-power Thulium fiber laser operating at a wavelength of 1.94 microm, was modulated to operate in pulsed mode with an output pulse energy of 1 J through a 300-microm-core silica fiber at a 20 milliseconds pulse length and repetition rate of 10 Hz. The fragmentation time to reduce uric acid (UA) (n = 13) and calcium oxalate monohydrate (COM) (n = 6) stones into particles < 2 mm was measured. RESULTS: Mean initial mass of the UA and COM stones measured 860+/-211 and 763 +/- 204 mg. Fragmentation rates measured 388 +/- 49 and 25 +/- 2 mg/minute. Average time needed to fragment the UA and COM stones into particles < 2 mm was 2.25 +/- 0.63 and 30.7 +/- 8.4 minutes, respectively. CONCLUSIONS: The high-power Thulium fiber laser, when operated in pulsed mode, is capable of fragmenting both soft (UA) and hard (COM) urinary stones. The Thulium fiber laser may be useful as a single laser system for use in multiple soft and hard tissue laser ablation applications in urology.

Calcium Oxalate↗

Influences of laser pulse duration and anastomotic disruption on laser-assisted microvascular anastomoses (LAMA).

The success rate of laser-assisted microvascular anastomosis (LAMA) can be influenced by many factors, including the parameters of the laser technique used. This study examined the effects of laser pulse duration and the occurrence of anastomotic disruption immediately following first repair attempts on the incidence of aneurysm formation and the patency rate in LAMA. Fifty transected rat femoral arteries in 25 rats were anastomosed with three stay sutures and welded with a CO2 laser at a power of 80 mW. In each rat, the laser was applied in the form of 45 pulses of 0.2 sec duration to one femoral artery (group 1) and in the form of 15 pulses of 0.6 sec duration to the contralateral femoral artery (group 2). Comparison of group 1 with group 2 showed that overall rates of aneurysm formation (30% vs. 17%) and patency rates (92% vs. 96%) did not differ significantly (P less than 0.05) at 3 weeks postoperatively. However, disrupted vessels in both groups had a significantly higher incidence of subsequent aneurysm formation than nondisrupted vessels (54% vs. 0% in group 1, P less than 0.05; 43% vs. 6% in group 2, P less than 0.06; groups 1 and 2 pooled, P less than 0.001). These findings indicate that changes in laser pulse duration such as those tested do not affect the aneurysm and patency rates of LAMA. The results demonstrate, however, that disruption after laser welding plays a significant role in subsequent aneurysm formation.

Anastomosis, Surgical↗

Local fundus response to blue (LED and laser) and infrared (LED and laser) sources.

Light damage research began during the early years of laser light exploration. There is a clear and significant literature that identifies an easily demonstrated retina-pigment epithelium pathology which is associated with short wavelength exposures below 520 nm. Recent interest has expanded because of the growing evidence for a blue light contribution to the retina aging process by way of a poorly understood chemical process(es) that involve circulation, oxidative reactions and the spectral absorption properties of the pigment epithelium. New powerful sources of relatively inexpensive blue energy have become available as a family of light emitting diodes. In this experiment, we examined funduscopic, angiographic and scanning laser tomographic measures of the retinal-pigment epithelium response to LED and laser spectral blue and infrared emissions closely matched in wavelengths and delivered under carefully matched circumstances. Ten retinas in normal young rhesus monkeys were locally exposed to various energy density values at 458 nm (Argon laser) ranging from 5 to 54 J cm(-2). Eight rhesus eyes were exposed to LED irradiation with a peak wavelength of 460 nm ranging from 9 to 62 J cm(-2). Similarly, a matched infrared (IR) laser and IR LED pair were used to expose an additional ten eyes for comparison of the long wavelengths. IR irradiance ranged from 21 to 306 J cm(-2). There was no response to IR exposure in any of the eyes. Blue light exposure results were measured from the color fundus photographs, scanning laser tomographs and early- and late-phase fluorescein angiogram responses at 2 and 30 days after the exposure. Results scores were accumulated for the four measures at the two time periods. The resulting lesion scores when plotted against the exposure in J cm(-2)showed no demonstrable effect at irradiance lower than 10 J cm(-2)and near 100% effectiveness for irradiance greater than 30 J cm(-2). The most sensitive and enduring indicator of change was the late fluorescein angiograms. Nonparametric statistical analysis of the scores from the two samples support the conclusion that there is no difference in the consequences of LED and laser light exposures under these matched conditions.

Analysis of Variance↗