Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Joint Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

[Quantitative determination of spongiosa formation of tibial cortical bone following knee joint total prosthesis implantation].

Cancellization always occurs following implantation of total knee joint replacements. In the study reported here the extent of the cancellization process at the tibia corticalis was investigated; it was found that the extent of cancellization differs according to the height and the time factor. The danger of cancellization as a risk to the joint prosthesis is pointed out with reference to a case in which a fracture occurred. The problem of isoelastic joint prostheses as alternatives for avoiding cancellization is discussed.

Adult↗

[The value of leukocyte scintigraphy in suspected implant infection in patients with chronic polyarthritis].

When infection of implants is suspected, optimal management requires accurate confirmation or exclusion of infection. However, in spite of demonstrative clinical signs cultures of smears or chemical parameters of inflammation frequently are ambiguous. Scintigraphy with indium-labeled white blood cells (WBC) has been reported to be sensitive and specific in the diagnosis of low-grade sepsis of the musculoskeletal system. Twenty-eight patients with possible infection were prospectively studied. Infection was suspected in 19 cases with total hip joint prosthesis, 14 cases with knee joint prosthesis and 1 case with shoulder joint prosthesis. All of them underwent scanning with indium-111-labeled WBC and subsequently underwent surgery. At surgery infections were determined by means of culture or histologic results. When correlated with culture and histologic results sensitivity of 111-indium-WBC imaging was 89% with a specificity of 67% and a predictive accuracy of 77%. In patients with rheumatoid arthritis, however, predictive accuracy of 111-indium-labeled WBC imaging was higher than with standard diagnostic methods. The difference was statistically significant (P < 0.05, chi(2)-test). In the patients examined as a whole, predictive accuracy of 111-indium-labeled WBC imaging does not differ from that of standard diagnostic methods. That is why expensive and time-consuming 111-indium-WBC imaging is not justified generally in diagnosis of infection of implants. 111-Indium-WBC imaging is well suited to supplement standard diagnostic methods in patients with rheumatoid arthritis.

Adult↗

Synovium-like tissue from loose joint replacement prosthesis: comparison of human material with a canine model.

The formation of synovium-like tissue is a biological response to a loose joint replacement prosthesis. Histological examination of this tissue has shown a synovial lining with a predominance of fibroblasts and macrophages, some multinucleated giant cells, and dispersed particles from the implant. Previous studies have reported elevated interleukin 1 (IL-1), prostaglandin E2 (PGE2), and collagenase in this tissue. We developed a canine model for the loose cemented femoral stem. Tissue harvested from the canine model was compared with human tissue retrieved at revision arthroplasty. Histology showed synovium, similar to that observed around loose human prostheses, adjacent to the canine cement sheath. Cells were isolated from this tissue and incubated in culture medium with or without naproxen for 3 days. Aliquots of the conditioned media were tested in the thymocyte proliferation assay to determine IL-1-like activity. IL-1 beta levels in human cell-conditioned media were analyzed by enzyme-linked immunosorbent assay, and PGE2 levels were measured by radioimmunoassay (RIA) using a PGE2 RIA kit (New England Nuclear). Human tissue contained levels of IL-1 beta in the range of 150 to 7,040 pg/mL and PGE2 levels of 82 to 952 ng/mL. The canine specimens contained IL-1-like activity and significant amounts of PGE2 (76 to 1,720 ng/mL). Naproxen decreased PGE2 levels in vitro. This animal model provides the means to investigate the in vivo and in vitro activity of the synovial cells around loose total joint prostheses.

Adult↗

Temporomandibular joint devices: treatment factors and outcomes.

TMJ devices have been used for many years in reconstruction of the temporomandibular joint (TMJ). The most common endosseous implant currently used in TMJ reconstruction is a mini-anchor that is placed in the posterior head of the condyle to support artificial ligaments to stabilize the articular disk in the proper position. A 2-year follow-up study shows a success rate of 90% in reference to incisal opening jaw and occlusal stability, and significant reduction in presurgical pain level. Some materials that have been used in TMJ reconstruction, including Proplast-Teflon (PT) and Silastic devices, have caused devastating problems for patients. These materials, (particularly the PT) can cause severe foreign-body giant-cell reaction, severe bone and soft-tissue destruction, and migration of particles to other body areas, and may initiate or exacerbate connective tissue and autoimmune disease problems. Christensen joint prosthesis has been reported to have very good success in TMJ reconstruction. The most thoroughly studied TMJ total joint device is the Techmedica custom-made total joint prosthesis, with a 5-year follow-up study on 31 patients and 52 reconstructed joints. All patients have functioning prostheses with good jaw and occlusal stability and an average pain reduction of 4.4 points on a 0-to-10 visual analog pain scale. However, this device currently is unavailable. In complex cases requiring multiple TMJ operations, particularly those with previously failed alloplast, a custom-made total joint prosthesis, using materials with proven safety and efficacy in orthopedic joint reconstruction, may be the only option available to improve predictably the quality of life of these patients.

Autoimmune Diseases↗

[Condylar reconstruction after resection of an intracapsular stomach carcinoma metastasis].

BACKGROUND: The mandible is a very uncommon place for a metastasis of a gastric carcinoma. Normally the area of the temporomandibular joint (TMJ) remains unaffected. The separate vascularization is discussed as one reason among others. Primary reconstruction after resection of the condyle is often problematic because an early onset of adjuvant systemic therapy is required. In this case, the insertion of a Quinn joint prosthesis is presented after resection of a TMJ metastasis. CASE: We report a hematogenic metastatic gastric adenocarcinoma in a 51-year old male who initially presented with increasing disclusion in the left molar region. Suspecting a metastatic adenocarcinoma of the TMJ, a condylectomy with immediate replacement by a total joint prosthesis was performed via a preauricular approach. Corresponding to the clinically and radiologically suspected diagnosis, the decalcified histological specimen presented as a metastatic gastric adenocarcinoma within the intracapsular region. RESULTS: The healing period of the implanted modified Quinn prosthesis was fast and uncomplicated after resection of this, to our knowledge, first documented metastatic gastric adenocarcinoma of the intracapsular region. After early restoration of joint function and patient satisfaction, the required radiochemotherapy of further unresectable bony metastases could be started in time. DISCUSSION: This example of an extremely rare case of a metastasis shows that such a total joint prosthesis appears to be a very good alternative to extended autogenous reconstruction or an unsatisfactory primary resection. Due to the mating of the spherical condylar head and glenoid fossa, the modified Quinn prosthesis is very suitable for total joint replacement after extended resection or in multiply preoperated cases.

Adenocarcinoma↗

Treatment of suppurative arthritis by percutaneous catheter drainage.

Percutaneous catheter drainage to treat suppurative arthritis was performed in five joints in five patients. Joints drained included the hip in two cases and one case each of a hip joint prosthesis, an ankle joint, and a glenohumeral joint. Organisms isolated from the joints included Staphylococcus aureus in one hip joint and the hip prosthesis, and Haemophilus influenzae in the ankle joint. Specific organisms were not isolated in the other hip joint or in the shoulder joint. Systemic antibiotic therapy was used in all five patients, and in two patients gentamicin was instilled through the catheters. Joint infection was managed successfully with catheter drainage and antibiotics in three patients. In all three cases, the range of motion was restored and the patients became free of pain after catheter drainage. These three patients remained asymptomatic at follow-up ranging from 3 weeks to 9 months. In two patients, percutaneous drainage failed. In one patient, the catheter positions could not be maintained and the catheters repeatedly became dislodged. In the other, superimposed osteomyelitis necessitated surgical debridement. No complications occurred. Our experience suggests that suppurative arthritis can be successfully treated with drainage of the joint via a percutaneous catheter in combination with antibiotic therapy.

Adult↗

Treatment outcomes for temporomandibular joint reconstruction after Proplast-Teflon implant failure.

A retrospective study of 107 patients (male, n = 13; female, n = 94) with 163 joints previously treated with Proplast-Teflon (PT; Vitek, Inc, Houston, TX) implants was performed. The average time in situ for the PT was 59.8 months (range, 2 to 126 months). Average length of follow-up was 84.6 months (range, 59 to 126 months). Only 12% of joints showed no significant osseous changes radiographically. Forty-five patients (42%) continue to have in situ PT implants and 36% of them experience pain that requires medication; 25% have developed an anterior open bite and malocclusion; 9% have limited vertical opening; and 40% are asymptomatic. Temporomandibular joint (TMJ) reconstruction after PT implant failure was performed with five different autologous tissues or a total joint prosthesis. Autologous tissues used to reconstruct the TMJ and the rates of success were as follows: 1) 31% free temporalis fascia and muscle graft with and 13% without sagittal split ramus osteotomy, 2) 8% dermis, 3) 25% conchal cartilage, 4) 12% costochondral grafts, and 5) 21% sternoclavicular grafts. The success rate decreased in all autologous tissue groups as the number of TMJ surgeries performed before reconstruction increased. Ankylosis was the most common cause of failure. Results of TMJ reconstruction with a total joint prosthesis were as follows: 1) 88% functional and occlusal stability of total joint prosthesis; 2) level of pain reduction was rated as 46% good, 38% fair, and 16% poor; and 3) an average interincisal opening of 27 mm at 24 months or less, and 33 mm at 25 months and beyond.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Neutrophils are active in total joint implant loosening.

BACKGROUND: Polymorphonuclear neutrophils (PMN) are the first cells to take part in the local foreign body reaction in aseptic loosening of endoprostheses. The aim of this study was to evaluate the systemic host reaction to total joint replacement by measuring the production of nitric oxide by neutrophils before and after total joint replacement. PATIENTS AND METHOD: Blood samples were collected from 33 patients (27 hips and 6 knees) before surgery, and 2 weeks, 2 months and 2.5-3 years after surgery. The levels of nitric oxide produced by PMN were measured by the method described by Markert et al. (1994). RESULTS: Patients reporting pain in the region of the implant 3 years after surgery, and also patients with radiographic signs of loosening, had higher production of NO in the early period and 3 years after the implantation than those with good clinical results. INTERPRETATION: We propose that elevated levels of nitric oxide production by PMNs may serve as a marker of total joint prosthesis loosening.

Aged↗

What is the role of bone scintigraphy in the diagnosis of infected joint prostheses?

AIM: To analyse the role played by bone scintigraphy in the diagnosis of infected joint prostheses. METHODS: The study included 77 patients, aged 32-77 years, in whom infection of a joint prosthesis (48 hip, 29 knee) was suspected. In all patients the following examinations were performed consecutively: a two-phase Tc methylene diphosphonate (Tc-MDP) bone scan, a Tc hexamethylproplyene amine oxime (Tc-HMPAO) labelled white blood cell (WBC) scan, and a Tc microcolloid bone marrow (BM) scan. The minimum interval between examinations was 48 h. The diagnoses were based on data obtained from bacteriological cultures. RESULTS: The bone scan was positive in all patients and 28 of them had an infection (sensitivity 100%, specificity 0%). The WBC scan was positive in 61 patients but only 27 had an infection. The WBC scan was negative in 16 patients, and the possibility of infection was discarded in 15 of these cases (sensitivity 96%, specificity 30%). The results of the bone marrow scan were not compatible with those of the WBC scan (suggestive of infection) in 27 patients: 26 of them had prosthesis infection. The results of both examinations were compatible in the other 34 patients and the possibility of infection was discarded in 33 of these patients (sensitivity 92.8%, specificity 98%). The addition of a BM scan to a WBC scan decreased the sensitivity from 96% to 92.8% but increased specificity from 30% to 98%. The addition of a bone scan to this dual combination did not alter the results. CONCLUSIONS: When infection of a prosthesis is suspected the diagnostic procedure should start with a WBC scan followed, if positive, by a BM scan. This procedure reduces the cost, the time required for a diagnosis, and the dose of radiation received by the patient.

Adult↗

Total joint replacement: where are we today, and where are we headed?

With the advent of noncemented total joint prostheses, today's orthopedic surgeons are asking questions about the predictability and performance of newer biologically fixed implants. Reported experience to date has failed to document any improved parameters of performance; instead, problems of prolonged convalescence, postoperative pain, and difficulties in revision procedures have been noted. Other issues of concern relate to the potential harmful effects of ion leaching, and problems of stress shielding and stress overload due to the physical properties of the materials presently available. Current investigative efforts to resolve these problems look promising, though surgeons should realize that science is a long way from producing the perfect total joint prosthesis.

Aging↗

[Experimental study of metallic bone and joint prostheses with plasma-sprayed ceramic coating].

In order to solve the loosening problem of endoprosthesis, a titanium-based alloy bone and joint prosthesis with plasma-sprayed ceramic coating was developed by the authors. By the fabrication powdered alumina or zirconium oxide were melted in an electric arc by a temperature of 10,000 K and sprayed onto the metallic prosthesis. The coating was 0.3 to 0.6 mm in thickness and had innumerable micropores. The pores were 50 to 200 microns in diameter. The metallic bone and joint prosthesis with plasma-sprayed ceramic coating exhibits characteristics of metal and ceramic, such as high mechanical strength, high resistance to corrosion and elution and good biocompatibility. According to our experimental study, the plasma-sprayed ceramic coating allows tissue ingrowth into its micropores and prevents the loosening of the prosthesis. Successful cases have been experienced through 10 years clinical application.

Aluminum Oxide↗

Surgical reconstruction of TMJ.

Certain situations and pathological processes that arise with temporomandibular joint destruction can only be resolved with surgical reconstructive procedures in order to attempt a functional and anatomical rehabilitation of this joint. Many of these situations can be surgically treated with the patient's own autologous tissues. However, in some patients reconstruction is complex and the use of autologous tissues is unadvisable whereas reconstruction utilizing alloplastic materials may be an appropriate alternative. The following report describes 4 clinical cases in which autologous grafts or Christensen joint prosthesis are employed in temporomandibular joint reconstruction.

Adult↗

[Results of treatment of hip joint prosthesis-related infections].

The article present results of the operative treatment of deep infections in the hip joint prostheses. Ninetieth patients treated from 1980 through 1998 were analysed. Gram-positive organisms were found in 65% of the cases and gram-negative in 35%. Staphylococcus aureus were isolated in 50% of the cases. The two-stage reimplantation procedure is performed in four patients. Excellent results were reported in three patients, and poor results in one patient. The Girdlestone pseudarthrosis as a definitive procedure is performed in fifteen patients. Good results were reported in two patients, fair results in twelve, and poor results in one patient. The mean shortening of the limb was 4.5 cm. The infection were controlled in 93% of the cases. Better functional results are obtained by the two-stage reimplantation than the Girdlestone pseudarthrosis, though is an acceptable method of controlling infection.

Adult↗