Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Inhalation Spacers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Assessment of the inhalation technique in asthmatic patients: a comparative study of three aerosol devices.

Local administration of drugs by means of aerosol device is widely used in the treatment of asthma. Nevertheless, the effectiveness of this method depends on an adequate inhalation technique (IT), which available evidence has shown to be rather problematic. The aim of this study was to assess IT in out-patients with bronchial asthma who frequently use aerosol therapy with Pressurized Metered dose inhalers (MDI), pressurized inhalers with spacer (MDI-S) and the Astra-Draco Turbuhaler system (TH). A sample of 150 adults with asthma were evaluated. These patients had been followed up for than two years and they often used one of the devices mentioned above. The IT has broken down into several steps for each procedure. Percentages of patients with one error in the IT were 50%, 44% and 42% for MDI, MDI-S and TH procedures, respectively. 18%, 20% and 14% of patients committed three errors in the IT, respectively. Differences detected were not significant. Seven patients committed errors in every step of the IT. In conclusion, the level of errors found in our study is high, similar to that cited in the existing literature. It is also roughly equivalent for the three devices tested. We believe that the proper teaching monitoring of IT skills is highly important in the treatment of bronchial asthma.

Administration, Inhalation↗

Pharmacokinetics of (R,S)-Albuterol after aerosol inhalation in healthy adult volunteers.

The pharmacokinetics of inhaled (R,S)-albuterol following pulmonary absorption were studied in healthy human subjects. Ten subjects (5 females and 5 males) inhaled two puffs (180 microg) of albuterol via a metered-dose inhaler and spacer device. All subjects were nonsmoking and had normal pulmonary function. Charcoal slurries were ingested to block gastrointestinal absorption of drug. Venous samples were obtained from each subject at thirteen time points from 0 through 12 h post dose. (R,S)-Albuterol concentration in plasma was measured using a gas chromatography-mass spectrometry (GC-MS) assay. The plasma concentration-time profiles conformed to a two-compartment extravascular model with first-order absorption kinetics. The drug levels reached maximum in 12.6 +/- 2.2 (SD) minutes, which is in contrast with previous reports that maximum plasma concentrations occur within 2 to 4 h. The mean peak plasma level was 1469 +/- 410 pg/mL. The mean half-life of distribution was 17.9 +/- 8.2 min. The mean half-life of elimination was 4.4 +/- 1.5 h. Female subjects achieved peak concentration more rapidly than male subjects (10.4 vs 14.8 min, p = 0.01) and had a higher mean peak concentration (1778 vs 1159 pg/mL, p = 0.04).

Absorption↗

Metal versus plastic spacers: an in vitro and in vivo comparison.

This study compared the metal Nebuchamber with the polycarbonate Volumatic spacer in vivo as well as in vitro. Seventeen asthmatic patients were evaluated in a crossover placebo-controlled double-blind study. Bronchodilation, heart rate and serum potassium levels were measured at baseline and 15 min after administration of salbutamol. Cumulative dose-response curves (200, 400, 800 and 1600 microg) were constructed. The Andersen Cascade Impactor was used to compare the aerodynamic particle size distribution. The FEV(1) measurements showed highly significant differences between placebo and the two active preparations (P<0.001), but not between the two active preparations (P=0.433). The serum potassium levels also showed highly significant differences between placebo and the two active preparations (P=0.009), but not between the two active preparations (P=0.532). Only 1600 microg salbutamol dose raised the heart rate significantly, but the difference between the two active preparations was not significant. The in vitro deposition study revealed no significant differences in the delivered dose or in the fine particle dose (P>0.05). In conclusion, there are no significant differences between the Volumatic and Nebuchamber either in vivo or in vitro.

Administration, Inhalation↗

Triple inhaled drug protocol for the treatment of acute severe asthma.

STUDY OBJECTIVE: This study tests the hypothesis that the administration of multiple doses of inhaled albuterol (A), ipratropium bromide (IB), and flunisolide (F) provides an additional benefit to adults with acute severe asthma compared with the administration of A plus IB (A/IB) or A plus F (A/F). DESIGN: Randomized, double-blind, prospective trial. PATIENTS AND INTERVENTIONS: One hundred seventy-two patients who presented to an emergency department were assigned to receive A, IB, and F (ie, triple drug treatment [TDG]; 56 patients), A/IB (60 patients), or A/F (56 patients). All drugs were administered through a metered-dose inhaler and spacer at 10-min intervals for 3 h. RESULTS: Patients who received TDG had an overall 64% greater improvement (95% confidence interval [CI], 24 to 103%; p = 0.002) in FEV(1) (mean [+/- SD], 2.1 +/- 0.6 L) than those who received A/F (mean, 1.7 +/- 0.6 L), and a 41% greater improvement (95% CI, 1 to 80%; p = 0.04) than those who received A/IB (mean, 1.8 +/- 0.6 L). Differences between groups increased with time (p = 0.001). At 3 h, there was a trend toward a reduction in hospital admission rates (A/IB group, 25%; A/F group, 20%; and TDG group, 11%). The patients who were the most likely to benefit (ie, those with a greater improvement in pulmonary function and a significant reduction in the hospitalization rate) from TDG were those with more severe obstruction (ie, FEV(1), < 30% of predicted). The benefit of TDG was equally evident independent of the patient's previous use of corticosteroids. CONCLUSIONS: The data suggest that there was a therapeutic benefit from the addition of IB and F to A administered in high doses, particularly in those patients in whom the FEV(1) was < 30% of the predicted value.

Acute Disease↗

Reduced effect of inhaled beta 2-adrenergic agonists on lung mucociliary clearance in patients with cystic fibrosis.

STUDY OBJECTIVE: It has been suggested that the defective cyclic AMP-dependent Cl- secretion and the increased Na+ absorption from airway epithelia in cystic fibrosis (CF) may lead to dehydrated secretions and impaired mucociliary clearance. Beta 2-adrenergic agonists are unable to stimulate the Cl- transport in the airways in CF while being able to do so in normal airways. Thus, we questioned whether the beta 2-adrenergic agonist, terbutaline, would improve mucociliary clearance in patients with CF as it does in healthy subjects. DESIGN: A double-blind, randomized cross-over trial. SETTING: Whole lung and regional mucociliary clearance of a radioaerosol was measured for 3 h by gamma camera. One minute of cough clearance was measured at 3 h. Pulmonary function was measured before and after the gamma camera study. PATIENTS: Ten young patients with CF were studied; three were heterozygous for deletion of the phenylalanine at position 508 (delta F508), and seven were delta F508 homozygous. INTERVENTIONS: Inhalation of 1 mg of terbutaline (4 puffs) and placebo via a metered-dose inhaler by spacer. MEASUREMENTS AND RESULTS: The largest differences in tracheobronchial retention (percent) in the whole lung and regional lung zones were generally observed within 1 h after terbutaline and placebo treatment: whole lung (mean +/- SD), 60 +/- 22 percent and 63 +/- 20 percent; central zone, 41 +/- 19 percent and 50 +/- 25 percent; midzones, 65 +/- 27 percent and 63 +/- 19 percent; and peripheral zones, 77 +/- 28 percent and 72 +/- 28 percent, respectively [p > 0.1]. Whereas none of these differences was statistically significant, subanalyses suggested an improvement in mucociliary clearance by terbutaline in the three delta F508 heterozygous patients but not in the seven delta F508 homozygous patients. One minute of voluntary coughing resulted in clearance of less than 8 percent of the initial radioactivity, with a trend of more peripheral zone clearance after terbutaline compared with placebo. A small significant decrease in airway resistance was detected 3 h after terbutaline. CONCLUSIONS: We conclude that 1 mg of terbutaline did not improve mucociliary clearance significantly in the patients with CF. Also, the effect of terbutaline was much less than demonstrated earlier in healthy subjects. This is consistent with earlier findings of a lack of beta-adrenergic modulation of Cl- transport in CF. Thus, no rehydration of the dry mucus in CF is expected, and a possible beta 2-agonist-induced increase in ciliary beating would have only a minor effect on overall mucociliary clearance.

Administration, Inhalation↗

A comparison of the lung deposition of budesonide from Easyhaler, Turbuhaler and pMDI plus spacer in asthmatic patients.

Inhaled corticosteroids in pressurized metered does inhalers (pMDIs) are often delivered via a large volume spacer device, but these are bulky and inconvenient. Dry powder inhalers (DPIs) provide a highly portable and convenient propellant-free alternative to pMDIs for asthma maintenance therapy However, each DPI could have unique in vivo delivery characteristcs. In order to quantify the total and regional lung deposition of budesonide (200 microg) from (a) Easyhaler, (b) Turbuhaler and (c) pMDI plus Nebuhaler 750 ml spacer, a three-way randomized cross-over study was carried out in 12 mild to moderate asthmatic patients. Deposition was quantified by the imaging technique of gamma scintigraphy Optimal inhalation techniques were used throughout. Mean (SD) whole lung deposition (% metered dose) was similar for Easyhaler [18.5 (7.8) %] and Turbuhaler [21.8 (8.2) %], but was significantly higher for pMDI plus Nebuhaler [44.1 (10.0) %, P < 0.01]. The regional distribution patterns in the lungs were predominantly central for all three devices. Nebuhaler reduced oropharyngeal deposition significantly compared with the two DPIs. Easyhaler showed comparable deposition to Turbuhaler and hence drugs delivered by Easyhaler would be expected to have a similar clinical effect to those delivered by Turbuhaler in asthma maintenance therapy.

Administration, Inhalation↗

Inhaled corticosteroids for non-specific chronic cough in children.

BACKGROUND: Cough in isolation of other clinical features is known as non-specific cough, which has been defined as non-productive cough in the absence of identifiable respiratory disease or any known aetiology. In children with non-specific cough the possibility of asthma being the underlying disorder is often raised (so called cough variant asthma). The proponents of cough variant asthma suggest a therapeutic trial of medications usually used to treat asthma. OBJECTIVES: To determine the efficacy of inhaled corticosteroids in non-specific cough in children over the age of two years. SEARCH STRATEGY: Searches were conducted on Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. Searches were current as of March 2004. SELECTION CRITERIA: All randomised (randomised and quasi-randomised) controlled clinical trials in which an inhaled corticosteroid (beclomethasone (BDP), fluticasone (FP), triamcinalone (TAA) or any other corticosteroid) were given for cough in children over two years of age were included. Two review authors independently assessed articles for inclusion and methodological quality. DATA COLLECTION AND ANALYSIS: Data from trials was extracted by both review authors and entered into the Cochrane Collaboration software program RevMan Analyses 1.0.2. MAIN RESULTS: Two trials met the inclusion criteria (123 participants). One compared inhaled beclomethasone dipropionate (400 micrograms per day) with placebo and the other compared fluticasone propionate (2 mg per day for 3 days followed by 1 mg per day for 11 days) with placebo. Both studies used metered dose inhalers via a spacer. With the lower dose of inhaled corticosteroid there was no significant difference between the beclomethasone and placebo groups. With the higher dose there was a significant improvement in nocturnal cough frequency after two weeks in children presenting with persistent nocturnal cough. However, a significant but smaller improvement was also seen with placebo. AUTHORS' CONCLUSIONS: In one study beclomethasone dipropionate (400 micrograms per day) was no different from placebo in reducing the frequency of cough measured objectively or scored subjectively. There might be a small improvement with very high-dose inhaled corticosteroid but the clinical impact of this is unlikely to beneficial.

Adrenal Cortex Hormones↗

Terbutaline aerosol from a metered dose inhaler via a 750 ml spacer. Effect on large and small airways.

The effect on large and small airways of a pressurized terbutaline aerosol delivered via a 750 ml spacer, or via an ordinary actuator, was investigated in a double-blind study of 15 patients with reversible obstructive airflow disease. There was significant bronchodilatation with both devices as measured by Raw, FEV1.0, PEFR, MEF75, MEF50, and MEF25. Raw showed, a significant difference in favour of the 750 ml spacer. Measurement of Closing Volume (CV) revealed a significant decrease with the spacer, but with the ordinary actuator there was a slight increase in CV; the difference between the devices was significant. The quotient Closing Volume/Vital Capacity (CV/VC%) was significantly decreased with the 750 ml spacer but not with the ordinary actuator. The decrease in volume of isoflow (VisoV) was more pronounced with the spacer but not significantly so. The results suggest that use of a 750 ml spacer may promote more extensive peripheral deposition of the drug in the bronchial tract.

Aerosols↗

Obstructive Sleep Apnea and Hypopnea Efficacy and Safety of a Long-Acting beta2-Agonist.

The effect of inhaled long-acting beta2-agonists in obstructive sleep apnea syndrome (OSAS) is unknown, although from the pharmacological point of view both therapeutic and adverse effects need to be considered. The purpose of this study was to obtain data on the efficacy and safety of salmeterol in patients with OSAS. In a randomized, double-blind, placebo-controlled, cross-over study, effects of salmeterol on respiration during sleep and sleep quality were investigated in 20 patients with OSAS. Of these, 4 patients were female, 16 male; the average age was 53.0 +/- 7.8 years, with average body mass index 28.0 +/- 3.0 kg small middle dot m(-2) and average apnea hypopnea index 35.6 +/- 17.8 h(-1). Patients with asthma, chronic obstructive pulmonary disease (COPD), and left heart failure were excluded. Placebo or verum (50 &mgr;g salmeterol) was administered at 7 pm by meter dose inhaler and spacer device. All patients underwent full polysomnography during baseline, placebo, and verum night. Statistical analysis was performed by StudentOs t-test (p > 0.05). Between the placebo and verum there were no differences in total sleep time, sleep stages, apnea index (AI), apnea hypopnea index (AHI), and nadir oxygen saturation. There was, however, 1) a significant deterioration of mean oxygen saturation (SaO2m; placebo 93.1 +/- 2.0 vs. verum 92.5 +/- 2.2%; p = 0.01), 2) of percent of time spent with an oxygen saturation (SaO2) </= 90% (placebo 13.1 +/- 14.5 vs. verum 19.5 +/- 20.8%; p = 0.02), and 3) a significant increase in heart rate (placebo 63.1 +/- 9.2 vs. verum 65.6 +/- 9.3 h(-1); p = 0.01). In patients with OSAS, salmeterol had no adverse effect on quality of sleep, AI or AHI. The slight increase in heart rate and the deterioration of oxygen saturation probably have no clinical relevance; the latter condition might be due to ventilation-perfusion-mismatch. This study excluded any influence of salmeterol on obstructive sleep apnea and hypopnea; on the other hand, salmeterol turned out to be safe in terms of OSAS. This might be of special importance in patients suffering from both OSAS and obstructive airway disease.

Journal Article↗

Dose-related bronchodilator response to aerosolized salbutamol (albuterol) in ventilator-dependent premature infants.

We used a placebo-controlled standardized protocol to define the dose-response relationship to the beta-adrenergic bronchodilator salbutamol (albuterol) in 10 ventilator-dependent premature infants at a postnatal age of 13.3 +/- 4.9 days. Passive respiratory system resistance and compliance were measured at baseline and 10 minutes after administration of salbutamol via a metered-dose inhaler and spacer device. Salbutamol caused a significant dose-related response with a 33% mean decrease in respiratory system resistance (p less than 0.05) and a 67% mean increase in respiratory system compliance (p less than 0.001). In seven and six patients, respectively, 100 micrograms of salbutamol caused significant improvement in resistance and compliance; 200 micrograms was required in the remainder, but one patient had no improvement in compliance. Oxygen saturation increased linearly with the increase in compliance. In 7 of the 10 infants, the duration of action of 200 micrograms of salbutamol on the following day was 3 hours. We conclude that bronchodilator treatment may be useful in the management of ventilator-dependent neonates with respiratory distress syndrome.

Aerosols↗

Critical pathway for the emergency department management of acute asthma: effect on resource utilization.

STUDY OBJECTIVE: To determine the effect of a critical pathway on resource utilization in asthmatic patients. METHODS: The study combined a prospective analysis of 149 patients with asthma treated by a pathway protocol with a retrospective analysis of 97 patients with asthma treated by conventional means. The setting was a community hospital. RESULTS: Among patients treated by protocol, oxygen use declined by 19% (P = .001), handheld nebulizer treatments by 33% (P = .001), saline locks by 15% (P = .011), and intravenous steroid administration by 13% (P = .034). There was an increase in the use of metered-dose inhalers with spacer by 64% (P = .001) and oral steroids by 18% (P = .027). CONCLUSION: A critical pathway, based primarily on national guidelines, can be an effective means of treating asthma patients in terms of resource utilization.

Acute Disease↗

Salbutamol treatment of acute severe asthma in the ED: MDI versus hand-held nebulizer.

The objectives of this study were to compare the efficacy of salbutamol delivered by either metered-dose inhaler plus spacer (MDI-spacer) or by wet nebulization (NEB), and to determine the relationships between physiologic responses and plasma salbutamol concentrations. Asthmatic patients presenting to the emergency department (ED) with acute severe asthma (forced expiratory volume in the first second [FEV1] less than 50% of predicted) were enrolled in a randomized, double-blind, parallel-group study. The MDI-spacer group received salbutamol, delivered via MDI into a spacer device, in four puffs actuated in rapid succession at 10-minute intervals (2.4 mg/h). The NEB group was treated with nebulized salbutamol, 1.5 mg, via nebulizer at 15-minute intervals (6 mg/h). Doses were calculated on the basis of the percentage of total dose that reaches the lower airway with both methods. The protocol involved 3 hours of this treatment. Mean peak expiratory flow rate (PEFR) and FEV1 improved significantly over baseline values for both groups (P=.01). However, there were no significant differences between both groups for PEFR and FEV1 at any point studied. The examination of the relationships between cumulative dose of salbutamol and change in FEV1 showed a significant linear relationship (P=.01) for both methods (MDI r=.97; NEB r=.97). The regression equations showed that for every 1 mg of salbutamol by MDI-spacer, 2.5 mg are needed from nebulization to have equal therapeutic response. At the end of treatment, the salbutamol plasma levels were 10.1+/-1.6 ng/ml for the MDI-spacer group and 14.4+/-2.3 ng/ml for the NEB group (P=.0003). Both groups showed a nonsignificant heart rate decrease. A significant group-by-time interaction means that differences between groups increased with time (P=.04). Additionally, the NEB group presented a higher incidence of tremor (P=.03) and anxiety (P=.04), reflecting larger systemic absorption of salbutamol. These data indicate that when doses used are calculated on the basis of the percentage of total drug that reaches the lower airway, there was equivalent bronchodilatation after salbutamol administered by either MDI-spacer or nebulization in patients with acute severe asthma. However, nebulizer therapy produced greater side effects related to the increase in salbutamol absorption and higher plasma level.

Acute Disease↗

[Inhaled antiasthmatics in children. How to choose?].

An optimal combination of anti-asthmatic drugs and delivery devices produces the best short- and long-term control in asthmatic children. Various inhalation devices can be used: nebulizer, metered dose inhaler with or without spacer devices, dry powder inhaler. Their use will depend on age, asthma severity, acute or long-term treatment and the child's preference. Explanation and control of inhalation techniques are essential for a good compliance.

Administration, Inhalation↗

[Inhalers and nebulizers in the children].

Inhaled way is the most efficient method to deliver drugs for the treatment of respiratory diseases. Pulmonary deposition depends upon the inhalation system and technique. The evaluation of the drug deposition is difficult, particularly in children. Because of irradiation, scintigraphic studies which permit the best approach of the pulmonary deposition are rare in children. Various inhalation systems are available: nebuliser, metered-dose inhaler with or without spacer device, dry powder inhaler. Whatever the system used, the control of asthma will be only possible with the regular evaluation of the child inhalatory technique.

Administration, Inhalation↗

Artificial neural network prediction of aerosol deposition in human lungs.

PURPOSE: To develop a rapid and reliable method for predicting the pattern of aerosol particle deposition within the human lungs, using artificial neural networks (ANNs). METHODS: Experimental data from the literature were used to train multi-layer perceptron (MLP) networks to allow for prediction of regional and total aerosol particle deposition patterns in human lungs. These data covered particle sizes in the range 0.05-15 microm and three different breathing patterns (ranging from "quiet" breathing to breathing "under physical work conditions"). Three different MLPs were trained, to provide separate predictions of aerosol particle deposition in the laryngeal, bronchial, and alveolar regions. The total deposition fraction for a given set of breathing conditions was computed simply as the sum of the outputs produced from the corresponding regional deposition MLPs. RESULTS: The ANNs developed are shown to give highly accurate predictions for both regional and total aerosol deposition patterns for all particle sizes and breathing conditions (with errors typically less than 0.04%). CONCLUSIONS: We conclude that the current set of ANNs can be used to give good predictions of particle deposition from polydisperse pharmaceutical aerosols generated from breath-actuated dry powder inhalers, nebulizers, and metered dose inhalers with spacers.

Aerosols↗

A review of once-daily delivery of anti-asthmatic drugs in children.

Determining which drug is suitable for, and which patient can benefit from, a once-daily dose of prophylactic treatment is important for practitioners who want to improve therapeutic compliance in children with asthma. According to the literature, once-daily delivery of cromolyn sodium, nedocromil or beclomethasone dipropionate must be avoided. On the other hand, switching from a twice-daily to a once-daily regimen is efficient and safe only in children with well-controlled asthma using nebulized or dry-powder budesonide, dry-powder fluticasone propionate, flunisolide, or sustained-release theophylline. Such information is not available for long-acting beta2-agonists, except for oral bambuterol. Initiating a once-daily treatment in previously untreated children can only be based on low doses of inhaled budesonide or on an oral drug, montelukast. Further studies in children with severe asthma or treated with metered-dose inhalers and spacer devices are required before recommending a once-daily drug delivery in such situations.

Anti-Asthmatic Agents↗

Peak inspiratory flows in children with cystic fibrosis.

OBJECTIVE: To show that in children with moderately severe cystic fibrosis lung disease: (i). inspiratory flow may be reduced; and (ii). peak inspiratory flow may be predicted from height, expiratory flow analysis or body mass index. METHODS: All children attending the Royal Children's Hospital, Melbourne, between May and July, 2001 who had cystic fibrosis, were aged > 5 years, were able to perform spirometry reproducibly and who had a forced expiratory volume in 1 s < 60% predicted were prospectively enrolled. Height, weight, peak inspiratory flow, forced expiratory volume in 1 s and forced vital capacity were recorded. Linear regression analysis was performed. RESULTS: The age range was 9.4-19.9 years. Sixteen boys and 11 girls were studied. All children had a peak inspiratory flow > 0.5 L/s. There was a significant relationship between peak inspiratory flow and forced vital capacity (R2 = 0.50) especially in boys (R2 = 0.65). In boys, peak inspiratory flow was significantly related to forced expiratory volume in 1 s (R2 = 0.47). There was no relationship between peak inspiratory flow and predicted values of expiratory flow, age, height, weight or body mass index. Logistic regression was used to predict the probability that peak inspiratory flow was < 2.0 L/s for a given forced vital capacity. If the forced vital capacity is > 2.5 L, peak inspiratory flow is likely to be > 2.0 L/s. CONCLUSIONS: In children with significant cystic fibrosis lung disease, peak inspiratory flow is likely to be > 0.5 L/s, which is required to activate dry powder inhalers. If the forced vital capacity is < 2.5 L, the peak inspiratory flow may be < 2.0 L/s, and a metered dose inhaler and spacer should be considered. Further studies that investigate the relationship between expiratory flow and peak inspiratory flow against an internal resistance are needed.

Child↗