Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Hand Joints”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Hand and wrist joint problems in patients with Ehlers-Danlos syndrome.

Ehlers-Danlos syndrome is a heritable disorder of connective tissue that is clinically characterized by joint hypermobility and skin hyperextensibility and fragility. Four of our patients who fit the criteria for Ehlers-Danlos syndrome are presented. Abnormalities in the hand and wrist joint that are directly related to joint hypermobility are discussed.

Adult↗

Urinary CTX-II levels are associated with radiographic subtypes of osteoarthritis in hip, knee, hand, and facet joints in subject with familial osteoarthritis at multiple sites: the GARP study.

OBJECTIVE: To assess the relation between the urinary concentrations of type II collagen C-telopeptide (UCTX-II) and radiographic signs of osteoarthritis (ROA) in the GARP (Genetics, Arthrosis and Progression) study. METHODS: UCTX-II levels were measured in GARP study participants, who are sibling pairs predominantly with symptomatic osteoarthritis at multiple sites. Kellgren and Lawrence scores were used to assess ROA in the knees, hips, hands, and vertebral facet joints, and spinal disc degeneration. A proportionate score was made for each joint location, based on the number of joints with ROA. The sum total ROA score represents a measure of cartilage abnormalities within each patient. By using linear mixed models the total ROA score and the joint site specific ROA scores were correlated with the UCTX-II level. RESULTS: In 302 subjects the mean (SD) and median (range) for UCTX-II were 265 (168) and 219 (1346) ng/mmol creatine, respectively. There was a significant association between the total ROA score and UCTX-II levels. Subsequent multivariate analysis showed that the joint site specific ROA score at all joint sites, except for spinal disc degeneration, contributed independently to this association. CONCLUSIONS: The total ROA score of GARP patients, representing cartilage abnormalities at the most prevalent ROA joint locations, showed an excellent correlation with UCTX-II levels. The specific ROA scores at the hip, hand, facet, and knee joints additively and independently explained this association. Even in patients with osteoarthritis at multiple sites, UCTX-II may be a sensitive quantitative marker of ROA.

Adult↗

Patterns of joint distribution in hand osteoarthritis: contribution of age, sex, and handedness.

The most frequent site of osteoarthritis (OA) is the hands, but the pattern of hand OA development remains controversial. Understanding these patterns may assist in evaluating biological aging, determining etiology, and proposing ways of preventing hand OA. We investigated the pattern distribution of OA in hands and the influences of age, sex, and handedness on its development. The study population was comprised of Chuvashians (660 males age 18-89 years and 585 females age 18-90 years). OA development was evaluated for 15 joints of each hand according to the Kellgren and Lawrence grading scheme. Statistical analyses included Pearson correlation, cluster analysis, MANCOVA, and linear and polynomial regression. OA changes first appeared in subjects <30 years of age. Metacarpophalangeal (MP) joints underwent the first OA changes until the sixth decade, when the row of distal interphalangeal (DIP) joints became most affected. Cluster analysis showed that symmetry was the most common pattern of interrelationship between rows of joints. The best-fitting and most parsimonious model of age-related pattern of hand OA was the polynomial two-interval linear model. It showed a higher rate of OA development during the relatively young ages, 32-34 years than later on. We found statistically significant differences between sexes only for the DIP (P = 0.019) and PIP (P = 0.011) rows of joints. Handedness had no influence on hand OA development.

Adolescent↗

The surgical management of stiff joints in the hand.

Significant and lasting improvement in stiff MP and PIP joints can be achieved by operative management. Operative intervention should be considered only after persistence of stiffness after a vigorous program of nonoperative therapy. In our series of 135 such stiff finger joints, capsulotomy increased the range of motion in MP joints by more than 30 degrees in 68 percent of the patients, more than 50 degrees in 57 percent, and more than 70 degrees in 32 percent. The increased range of motion for the PIP joints was more than 30 degrees in 63 percent of the patients, more than 50 degrees in 41 percent, and more than 70 degrees in 25 percent.

Exercise Therapy↗

The role of soft tissue reconstruction in flexible implant arthroplasty of the metacarpophalangeal joint.

In 116 hand metacarpophalangeal joint arthroplasties of the flexible type, the operative technique did not include reconstruction of capsular or ligamentous structures, but employed meticulous relocation of the common extensor tendons, and a modification of the metacarpal osteotomy plane and shape. A closely supervised program of splintage and therapy was instituted postoperatively. This series does not vary significantly with respect to range of motion or recurrence of ulnar drift (seen only when patients failed to wear splints as directed) in comparison to other reports. The results, therefore, fail to support the concept that radial capsular and ligamentous reconstruction is an essential part of this procedure.

Arthroplasty↗

Association of matrilin-3 polymorphisms with spinal disc degeneration and osteoarthritis of the first carpometacarpal joint of the hand.

BACKGROUND: Seven polymorphisms in the matrilin-3(MATN3) gene were previously tested for genetic association with hand osteoarthritis in an Icelandic cohort. One of the variants, involving a conserved amino acid substitution (T303M; SNP5), was related to idiopathic hand osteoarthritis. OBJECTIVES: To investigate SNP5 and two other promising polymorphisms (rs2242190; SNP3, rs8176070; SNP6) for association with radiographic and symptomatic hand osteoarthritis phenotypes, as well as other heritable phenotypes. METHODS: Polymorphisms were examined in two distinct cohorts of subjects: a population based sample from the Rotterdam study (n = 809), and affected siblings from the genetics, osteoarthrosis and progression (GARP) study (n = 382). RESULTS: The originally described association of T303M with the hand osteoarthritis phenotype was not observed in the populations studied. In the Rotterdam sample, however, carrying the T allele of T303M conferred an odds ratio of 2.9 (95% confidence interval (CI), 1.2 to 7.3; p = 0.02) for spinal disc degeneration. In the GARP study, carriers of the A allele of SNP6 had an odds ratio of 2.0 (95% CI, 1.3 to 3.1, p = 0.004) for osteoarthritis of the first carpometacarpal joint (CMC1) as compared with the Rotterdam sample as a control group. Subsequent haplotype analysis showed that a common haplotype, containing the risk allele of SNP6, conferred a significant risk in sibling pairs with CMC1 osteoarthritis (odds ratio = 1.7 (95% CI, 1.1 to 2.7, p = 0.02)). CONCLUSIONS: These associations suggest that the MATN3 region also determines susceptibility to spinal disc degeneration and CMC1 osteoarthritis.

Alleles↗

Percutaneous arthrodesis of small joints in the hand. A minimum three-year follow-up.

Our aim in this prospective study was to evaluate a minimally invasive technique for percutaneous arthrodesis of the small joints in the hand. Thirteen arthrodeses were undertaken in 11 patients, eight women and three men. After the percutaneous removal of articular cartilage, the bony surfaces were aligned in a predetermined position and stabilised using a percutaneous screw system. The mean follow-up was 38.6 months (36 to 56). Bony union was achieved in 12 cases (ten patients) between nine and 12 weeks after surgery. In one patient a second operation was required to obtain union and another developed a painless nonunion after premature removal of the implants.

Adult↗

How many joints in the hands and wrists should be included in a score of radiologic abnormalities used to assess rheumatoid arthritis?

Numerous methods for reading abnormalities of rheumatoid arthritis in hand and wrist radiographs have been proposed over the past several decades. There are many differences among these methods, one of the more striking of which is the variation in the number of joints that are scored. In this study, we tested the number of joints that need to be read in order to represent abnormalities accurately and reproducibly, using the scores of multiple observers. Thirteen rheumatologists and radiologists each read a set of 41 hand and wrist films from patients with rheumatoid arthritis. Ten of 13 readers scored 27 joints in each hand and wrist; the other 3 readers scored fewer areas. Fourteen combinations of joints were selected based on the frequency of involvement and the technical adequacy of routine films in assessing a given area. After testing these 14 different combinations, 1 scheme, which included 17 areas read for erosions and 18 areas read for joint space narrowing, was tested further. The correlation coefficients for 10 intraobserver scores derived from this modified scheme compared with the original scores were between 0.981 and 0.997. Seventy-one of 78 interobserver comparisons were better using the new scheme than using the original scheme. These data indicate that the simplified scheme, using a combination of 17 joints to score erosions and 18 to score joint space narrowing, more accurately reflects the extent of abnormalities perceived by a panel of experts than does the original scheme. This abbreviated number of joints shortens the amount of time required to read a set of films and simplifies the scoring of films, since a number of areas that are difficult to read are eliminated from radiographic assessment.

Arthritis, Rheumatoid↗

High-resolution magnetic resonance imaging of the interphalangeal joints of the hand.

High-resolution magnetic resonance imaging (MRI) of the interphalangeal joints of the fingers is being employed to study arthritis. To facilitate this research, a clear understanding of the structures visualisable by MRI is necessary. A gradient echo (GE) sequence was developed that produced good contrast between cartilage and other joint structures. These detailed images, with an in-plane resolution of 200 x 100 microns, enable resolution of three cartilage zones which can be interpreted as a superficial layer at the cartilage/cartilage interface, an intermediate layer and calcified cartilage in contact with bone; these correlate well with known anatomy. Further analysis of the images indicates that although a chemical shift artifact causes changes in the images at the field strength used (0.5 T), it does not cause enough distortion to necessitate suppression of the effect. Furthermore, the only detectable susceptibility artifact at these low field strengths was a loss of signal in bone trabeculae at the bone/cartilage interface. There is clearly potential in the study of the articular structures, in particular cartilage, in detail, using high-resolution MRI.

Adult↗

Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand.

PURPOSE: The purpose of this study was to evaluate the clinical results of Swanson silicone implant arthroplasty of the proximal interphalangeal (PIP) joint, specifically evaluating clinical results with long-term assessment. METHODS: A retrospective review of 70 silicone implants of the PIP joint in 48 patients was performed with an average follow-up period of 6.5 years (range, 3-20 y). Clinical assessment included motion, stability, and alignment. Radiographic assessment included implant fracture, deformity, and cystic bone resorption. The pathology consisted of degenerative joint disease in 14, posttraumatic arthritis (TA) in 11, rheumatoid arthritis (RA) in 13, and idiopathic arthritis (IA) associated with collagen disease in 12 patients. Swan neck and boutonniere deformities were assessed separately. Statistical analysis of preoperative risk factors was compared with the postoperative assessment of pain, motion, and function (return to work). RESULTS: There was no significant change in the active range of motion (ROM) before and after PIP arthroplasty (26 degrees vs 30 degrees ). Correction of swan neck and boutonniere deformities was difficult, usually leading to poor results. There was improvement in maximum active extension before surgery lacking 32 degrees to after surgery lacking 18 degrees . From a statistical standpoint rheumatoid joint involvement with PIP arthroplasty had poorer results than degenerative or posttraumatic arthritis with respect to pain relief and ROM. Pain relief was present in 70% of replaced PIP joints with residual pain and loss of strength in 30%. Radiographic analysis showed abnormal bone formation (cystic changes) in 45%. There were 11 implant fractures and 9 joints that required revision surgery. CONCLUSIONS: Silicone replacement of the PIP joint is effective in providing relief of pain from arthritis but does not provide improvement in motion or correction of deformity. It provided a poorer outcome in rheumatoid disease in comparison with degenerative, posttraumatic, or idiopathic arthritis.

Arthritis↗

Correction of long term joint contractures of the hand by distraction. A case report.

Joint contractures are a common complication of hand trauma. The conventional treatment consists of arthrolysis, tenolysis and occasionally arthrodesis. Frequently, this does not achieve a good result, particularly when there has been a long delay in presentation. Progressive lengthening of a joint by distraction (joint distraction) allows the release of joint contractures even in cases of failure of traditional methods. We present a case of a delayed (20 years) work related traumatic flexion deformity of the PIP joint of the left index and middle fingers. This was the result of a complete division of both flexor tendons of both fingers. The range of movements, both active and passive, was limited to 90/100 degrees in the index finger and 95/100 degrees in the middle finger. Following joint distraction using our lengthening device (Antãotrade mark, Portugal) the patient was able to achieve an active and passive range of movements of 10/100 degrees for the PIP joint of the index finger and 40/100 degrees of the middle. This clinical case shows the simplicity and application of our technique for the correction of joint contractures.

Adult↗