Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GAS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Enantiomeric separation of chiral polychlorinated biphenyls on beta-cyclodextrin capillary columns by means of heart-cut multidimensional gas chromatography and comprehensive two-dimensional gas chromatography. Application to food samples.

Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE, and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent, separated using these beta-cyclodextrin based columns. Multidimensional techniques, such as heart-cut multi-dimensional gas chromatography (heart-cut MDGC) and comprehensive two-dimensional gas chromatography (GC x GC), were investigated for their ability to solve coelution problems with other PCBs present in commercial mixtures and real-life samples. Heart-cut MDGC improved the separation as compared to one-dimensional GC, and enantiomeric fractions of the investigated chiral PCBs could be determined free from interferences. However, limitations on the number of target compounds that can be transferred to the second column in a single run and, therefore, the time consumption, have led to the evaluation of GC x GC as an alternative for this type of analysis. With GC x GC, two column set-ups were tested, both having a chiral column as first-dimension column, and two different polar stationary phase columns in the second dimension. On using both column combinations, congeners 84, 91, 95, 132, 135, 136, 149, 174, and 176 could be determined free from coelutions with other PCBs. Results on the application of heart-cut MDGC to food samples such as milk and cheese are given, as well as the first results on the application of GC x GC to this type of samples.

Animals↗

Analysis of triacetone triperoxide by gas chromatography/mass spectrometry and gas chromatography/tandem mass spectrometry by electron and chemical ionization.

The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.

Forensic Sciences↗

Gas phase infrared spectra of 209 polychlorinated biphenyl congeners using gas chromatography with Fourier transform infrared detection: internal standardization with a 13C-labelled congener.

The gas phase infrared spectra of biphenyl and 209 polychlorinated biphenyls (PCB) are observed; 30 are presented in graphical form so that their uniqueness can be appreciated. The spectra were observed with a gas chromatograph linked via a light pipe with a Fourier transform infrared spectrometer. Unequivocal library matches (with match factors > 990 in 1000) can be performed with 50 ng of a congener injected into the chromatograph. Quantitation with the technique was briefly investigated with 2,2',5,5'-tetrachlorobiphenyl (BZ no. 52). Selective wavelength chromatograms of the most intense absorption (1457cm-1) were integrated. Septuplicate injections showed that 20 ng of the compound could be determined with +/- 4% precision. The resolution of the spectrometer was sufficient to distinguish between the 13C-labelled trichlorobiphenyl and the unlabelled material, indicating the possibility of internal or surrogate standardization of PCB analysis.

Carbon Isotopes↗

Diffusion-limited gas mixing in the lung and its consequences for transpulmonary gas transport.

The ratio of alveolar ventilations of He and SF6 (VA,He/VA,SF6) was determined in 7 healthy male subjects at rest and at three different levels of exercise on a bicycle ergometer (75, 150 and 225 W). This ratio was calculated from the ratio of the specific ventilations for these gases which were obtained from the decay of the end-tidal partial pressures of He and SF6 during a simultaneous, multiple-breath washout. In all experiments, VA for He was larger than VA for SF6. On the average, VA,He/VA,SF6 was equal to 1.09, and the mean values of this ratio at rest and at the three levels of exercise were not significantly different. Therefore, the difference in VA for He and SF6 (VA,He-VA,SF6) increased with increasing work load. Further, we used the mean value obtained for VA,He/VA,SF6 to calculate the ratio of excretion values (E1/E2) for pairs of hypothetical tracer gases with equal blood-gas partition coefficients and with different diffusivities in the gas phase. E1/E2 ranged from unity for lambda = 0 to about 1.08 for lambda = 10. At a given lambda, E1/E2 decreased with increasing ventilation-perfusion ratio of the lung. Thus, the difference between the excretion values of light and heavy tracer gases will be most pronounced under rest conditions and for gases that are well soluble in blood.

Adult↗

Study of the microbiodegradation of terpenoid resin-based varnishes from easel painting using pyrolysis-gas chromatography-mass spectrometry and gas chromatography-mass spectrometry.

The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have been evaluated using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) and gas chromatography-mass spectrometry (GC-MS). The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC-MS. Two types of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally, the studied biocides--Biotin, New-Des and Nipagine--generally exhibited good inhibiting effects on the microorganisms studied, although some interesting differences were found between them regarding the application method and type of biocide.

Biodegradation, Environmental↗

Monoamine metabolites and related compounds in human amniotic fluid: assay by gas chromatography and gas chromatography-mass spectrometry.

Some catecholamine metabolites and related compounds have been identified in amniotic fluid obtained by transabdominal amniocentesis at various stages of pregnancy, including 4-hydroxy-3-methoxymandelic acid, 4-hydroxy-3-methoxyphenylglycol, 4-hydroxy-3-methoxyphenylcetic acid, p-hydroxypheny lacetic acid, p-hydroxphenyllactic acid and N-benzoylglycine (hippuric acid). Analysis was by gas chromatography with electron capture detection and by gas chromatography-mass spectrometry. Two of these compounds were determined quantitatively, free 4-hydroxy-3-methoxphenylglycol and p-hydroxyphenllactic acid: the concentration of the former increased with advancing pregnancy and that of the latter tended to decrease. Conjugated 4-hydoxy-3-methoxyphenylglycol could not be determined with accuracy as appreciable amounts of the unconjugated compound were found in the snail extract used for enzymatic hydrolysis. Assay of 4-hydroxy-3-methoxyphenylglycol in amniotic fluid is likely to be of diagnostic importance in the prenatal diagnosis of congenital neuroblastoma. Although 4-hydroxy-3-methoxyphenylethanol, 3, 4-dihydroxymandelic acid and 3, 4-dihydroxyphenylacetic acid were specifically looked for in amniotic fluid, they could not be detected.

Amniocentesis↗

Analysis of the major urinary thromboxane metabolites, 2,3-dinorthromboxane B2 and 11-dehydrothromboxane B2, by gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry.

2,3-Dinorthromboxane B2 and 11-dehydrothromboxane B2, the two major metabolites of thromboxane B2, are considered to be indices of thromboxane A2 activity in humans. The determination of these metabolites in urine was comparatively performed by gas chromatography-mass spectrometry and gas chromatography-mass spectrometry-mass spectrometry using the corresponding chemically synthesized tetradeuterated analogues as internal standards. The urine samples of five females and two males, all healthy, were prepurified by solid-phase extraction. The corresponding pentafluorobenzyl ester derivatives were repurified by high-performance liquid chromatography. The concentrations of 2,3-dinorthromboxane B2 and 11-dehydrothromboxane B2 ranged from 21 to 266 pg/ml and 47 to 942 pg/ml, respectively. The ratio of urinary 2,3-dinorthromboxane B2 to 11-dehydrothromboxane B2 varied from 1:3 to 1:5, except for one sample with nearly equal concentrations of 2,3-dinorthromboxane B2 and 11-dehydrothromboxane B2.

Chemical Phenomena↗

Complementary use of gas chromatography-mass spectrometry, gas chromatography-atomic emission detection and nuclear magnetic resonance for identification of pharmaceutically related impurities of unknown structures.

The complementary use of gas chromatography-mass spectrometry (GC-MS), gas chromatography-atomic emission detection (GC-AED) and nuclear magnetic resonance (NMR) spectroscopy is demonstrated by the identification of four major by-products in a sample from an exploratory attempt to synthesise 1.3-dichloro-5-(difluoromethoxy)benzene. GC-MS was used for straightforward identification of the target compound and one of the impurities. By employing GC-AED, the sample was screened for heteroatoms in the analysed molecules and determination of the partial empirical formula of one sample component was carried out. The combined spectroscopic data obtained from the MS and AED experiments facilitated structure elucidation of two of the additional by-products. Finally, identification of the last unknown component could be obtained by combining spectral information from GC-MS, GC-AED and NMR data acquired after isolation of the impurity from the sample.

Gas Chromatography-Mass Spectrometry↗

Characterisation of beeswax in works of art by gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry procedures.

Pyrolysis (Py) with in situ derivatisation with hexamethyldisilazane-gas chroma-break tography-mass spectrometry (GC-MS) and a gas chromatography-mass spectrometry procedure based on microwave-assisted saponification were used to identify the organic components in small sized beeswax samples. With the latter procedure quantitative recoveries can be made and hydrocarbons, alcohols and omega-1-diols in the neutral fraction, and fatty acids and omega-1-hydroxy acids in the acidic fraction can be efficiently separated and detected. Both procedures were used to characterise a wax anatomic sculpture "The Plague" (1691-1694) by Gaetano Zumbo, resulting in the identification of beeswax and a Pinaceae resin. The GC-MS analysis brought to light some essential differences in beeswax composition between the raw material and the old modelled wax thus giving some clear indications about the recipe used by the sculptor.

Alcohols↗

Novel flame photometric detector for gas chromatography based on counter-current gas flows.

A novel analytical device has been developed for gas chromatography. It is based on optical emission from a counter-current (i.e. counter-flowing) air or oxygen flame, which burns in an opposing stream of hydrogen and column effluent. The flame is typically positioned "upside down" on the upper (air) jet, which faces the lower (hydrogen + effluent) jet. It can also be positioned on the lower jet, be connected to both jets, or be suspended in the gap between them. Excellent stability can be obtained in any of these modes. Overall, this new "counter-current flame photometric detector" (ccFPD) responds to analytes in the manner of a conventional flame photometric detector (FPD); however, it can be operated over a much wider range of gas flows. For instance, the same physical ccFPD burner easily supports stable flames of air flows between 5 and 200 ml/min and corresponding hydrogen flows between 5 and 10,000 ml/min. Visual observation of the counter-current flame, in the presence of sulfur and phosphorus as test analytes, reveals intense, steady luminescence under a wide variety of conditions. Additionally, and in contrast to the commercial FPD, flame conductivity signals can be obtained that are similar in quality to those produced by a conventional flame ionization detector (FID). Thus the ccFPD is a flexible, easily optimized photometric detector. The exceptional flow stability of the ccFPD was used to explore the earlier reported phenomenon of strong signal/noise (S/N) ratios, which had been obtained for hetero-elements of the iron group from a conventional FPD with a small, stoichiometric flame. Results using the ccFPD, which also exhibits this unusual response, indicate that these high S/N ratios are only partly due to the predictable decrease in flame noise with decreasing flame size. Contrary to expectations, the absolute analyte signal often increases as the flame size decreases to the point of extinction. The signal intensity and the magnitude of the observed changes depend to some degree on the flame composition (H2/O2 ratio).

Chromatography, Gas↗

Monolayer-protected gold nanoparticles as an efficient stationary phase for open tubular gas chromatography using a square capillary model for chip-based gas chromatography in square cornered microfabricated channels.

The application of a dodecanethiol monolayer-protected gold nanoparticle (MPN) stationary phase within a microchannel environment was explored using a square capillary column as a model for high-speed, microfabricated gas chromatography (microGC). Successful deposition and evaluation of a dodecanethiol MPN phase within a 1.3 m long, 100 microm x 100 microm square capillary is reported. The thickness of the MPN phase was evaluated using SEM analysis. An average thickness of 15 nm along the capillary walls was determined. While the film depth along the walls was very uniform, the corner depths were greater with the largest observed depth being 430 nm. Overall, an efficient chromatographic system was obtained with a minimum reduced plate height, h(min), of 1.2 for octane (k = 0.22). Characterization of the MPN column was completed using four compound classes (alkanes, alcohols, ketones, and aromatics) that were used to form a seven-component mixture with a 2-s separation. A mixture consisting of a nerve agent simulant in a sample containing analytes that may commonly interfere with detection was also separated in only 2 s, much faster than a similar separation previously reported using a microGC system requiring 50 s. A comparison of the MPN stationary phase to phases employed in previously reported microGC systems is also made. Application of the square capillary MPN column for a high-speed separation as the second column of a comprehensive 2-D gas chromatography system (GC x GC) was also explored.

Chromatography, Gas↗

Analysis of natural gas by gas chromatography reduction of correlated uncertainties by normalisation.

The results of gas chromatographic analysis of natural gas mixtures reveal strong correlations (Pearson correlation coefficient of >0.96) between the uncertainty of each component and variations in the ambient pressure. Although correction for ambient pressure variations can reduce this variability, normalisation of the results of each analysis using the assumption that the sum of all component amount fractions is unity provides significantly greater reductions in the uncertainty of each measured component. We show that the uncertainty in normalised components can be estimated approximately using the correlation coefficient as a measure of the correlation present in the measurements, or exactly using a full calculation of the variance/covariance (V/C) structure of the data.

Chromatography, Gas↗

Comparison of conventional gas chromatography and comprehensive two-dimensional gas chromatography for the detailed analysis of petrochemical samples.

Comprehensive two-dimensional gas chromatography (GC x GC) has been investigated for the characterization of high valuable petrochemical samples from dehydrogenation of n-paraffins, Fischer-Tropsch and oligomerization processes. GC x GC separations, performed using a dual-jets CO2 modulator, were optimized using a test mixture representative of the hydrocarbons found in petrochemicals. For complex samples, a comparison of GC x GC qualitative and quantitative results with conventional gas chromatography (1D-GC) has demonstrated an improved resolution power of major importance for the processes: the group type separation has permitted the detection of aromatic compounds in the products from dehydrogenation of n-paraffins and from oligomerization, and the separation of alcohols from other hydrocarbons in Fischer-Tropsch products.

Chromatography, Gas↗

Characterization of complex hydrocarbons in cigarette smoke condensate by gas chromatography-mass spectrometry and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

Gas chromatography-mass spectrometry with electron ionization and positive-ion chemical ionization and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF-MS) were applied for the characterization of the chemical composition of complex hydrocarbons in the non-polar neutral fraction of cigarette smoke condensates. Automated data processing by TOF-MS software combined with structured chromatograms and manual review of library hits were used to assign the components from GC x GC-TOF-MS analysis. The distributions of aliphatic hydrocarbons and aromatics were also investigated. Over 100 isoprenoid hydrocarbons were detected, including carotene degradation products, phytadiene isomers and carbocyclic diterpenoids. A total of 1800 hydrocarbons were tentatively identified, including aliphatic hydrocarbons, aromatics, and isoprenoid hydrocarbons. The identified hydrocarbons by GC x GC-TOF-MS were far more than those by GC-MS.

Gas Chromatography-Mass Spectrometry↗

On-line introduction of high-pressure gas-liquid sample for capillary gas chromatographic analysis.

An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 microL and a washing solvent loop of 0.5 microL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique.

Chromatography, Gas↗

Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.

1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The relative standard deviation (R.S.D.) values of each analytical method were smaller than 3%. The amount of 1,4-dioxane was found to vary from 11.6 +/- 0.3 ppm to 73.5 +/- 0.5 ppm in 30% of nonionic surfactants from manufacturers in Taiwan. These methods were linear over the studied range of 3-150 ppm with correlation coefficients higher than 0.995. The recoveries of 1,4-dioxane for these nonionic surfactants following SPME were all higher than 96 +/- 1% (n = 3). The detection limits of 1,4-dioxane for these nonionic surfactants following SPME were from 0.06 ppm to 0.51 ppm. The experimentally determined level of 1,4-dioxane in cosmetics from manufacturers in Taiwan varied from 4.2 +/- 0.1 ppm to 41.1 +/- 0.6 ppm in 22% of daily used cosmetics following SPME coupled with GC and GC-MS. Conventional solvent extraction takes around 1 h for extraction and reconcentration but SPME takes only around 10 min. SPME provides better analyses of 1,4-dioxane in nonionic surfactants and cosmetics than conventional solvent extraction and head space pretreatments in term of simplicity, speed, precision, detection limit, and solvent consumption.

Calibration↗

Analysis of tert-butyldimethylsilyl derivatives in heavy gas oil from Brazilian naphthenic acids by gas chromatography coupled to mass spectrometry with electron impact ionization.

Naphthenic acids, C(n)H(2n+Z)O(2), are a complex mixture of alkyl-substituted acyclic and cycle-aliphatic carboxylic acids. The content of naphthenic acids and their derivatives in crude oils is very small, which hinders their extraction from matrixes of wide and varied composition. In this work, liquid-liquid extraction, followed by solid phase extraction with an ion exchange resin (Amberlyst A-27) and ultrasound desorption were used to isolate the acid fraction from heavy gas oil of Marlim petroleum (Campos, Rio de Janeiro, Brazil). The analysis was accomplished through gas chromatography coupled to mass spectrometry with electron impact ionization, after derivatization with N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBDMSTFA). The results indicate the presence of carboxylic acids belonging to families of alicyclic and naphthenic compounds which contain up to four rings in the molecule.

Carboxylic Acids↗

Comparative study on the gas-phase adsorption of hexane over zeolites by calorimetry and inverse gas chromatography.

The scope of this work is to carry out a systematic comparison of inverse gas chromatography (IGC) and microcalorimetry as tools for the study of the gas-phase adsorption of organic vapours (using hexane as model compound) on zeolitic materials (using different Mn, Co and Fe-exchanged NaX and CaA zeolites). Adsorption isotherms were recorded using both techniques in the temperature range of 150-250 degrees C, being observed that the shape of the isotherms obtained with the dynamic (IGC) and static (microcalorimetry) techniques was surprisingly similar in the pressure range at which both techniques are applicable (low surface coverages). Concerning to the measurement of the strength of the adsorption, calorimetric data provide two parameters related to the adsorption enthalpy: the initial differential heat and the isosteric adsorption enthalpy. A great coincidence was found between the last one and the adsorption enthalpy determined by IGC (4-20% of difference, depending on the studied material). The behaviour of the initial differential heat depends strongly on the studied material, being in some cases closely related to the other two parameters and temperature-independent (in the case on Mn-exchanged zeolites), whereas for the Co-CaA and Fe-CaA zeolites, it is temperature-dependent, being not correlated with the other parameters in this case. The main conclusion of this work is that IGC is an attractive alternative to the static microcalorimetric data for obtaining information on the adsorption of organic compounds on microporous materials.

Adsorption↗