Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fluorescence Microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Quantification of fetomaternal hemorrhage by fluorescence microscopy is equivalent to flow cytometry.

BACKGROUND: The quantification of fetal cells in the maternal circulation remains an important goal to determine the amount of anti-D necessary to prevent active immunization of a D- mother giving birth to a D+ baby. Underestimation of fetomaternal hemorrhage (FMH) results in inefficient anti-D prophylaxis and maternal immunization; overestimation of FMH results in higher doses of passively transferred anti-D, higher costs, and the risk of disease transmission. Thus, a reliable method to quantitatively assess FMH is necessary. STUDY DESIGN AND METHODS: Serial dilutions of artificial FMH were quantitatively measured by three different methods: flow cytometry, fluorescence microscopy (each after anti-D staining), and by the Kleihauer-Betke test. The accuracy and precision of the three methods were compared by statistical analysis. RESULTS: Fluorescence microscopy and flow cytometry were comparably accurate and precise in quantifying FMH. In contrast, the accuracy of the Kleihauer-Betke test was poor, resulting in substantial overestimation of FMH in the samples with lower fetal cell concentrations. CONCLUSION: Anti-D flow cytometry and fluorescence microscopy for detection of fetal cells offer equally reliable and precise methods in contrast to the Kleihauer-Betke test. Fluorescence microscopy may be established as standard to quantify FMH in clinical practice because it is comparable to flow cytometry; in addition, it is time saving and is less expensive.

Adult↗

Two-photon excitation fluorescence microscopy with a high depth of field using an axicon.

In conventional two-photon excitation fluorescence microscopy, the numerical aperture of the objective determines the lateral resolution and the depth of field. In some situations, as with functional imaging of dynamic events distributed in live biological tissue, an improved temporal resolution is needed; as a consequence, it is imperative to use optics with a high depth of field to simultaneously image objects at different axial positions. With a conventional microscope objective, increasing the depth of field is achieved at the expense of lateral resolution. To overcome this limitation, we have incorporated an axicon in a two-photon excitation fluorescence microscopy system; measurements have shown that an axicon provides a depth of field in excess of a millimeter, while the lateral resolution is maintained at the micrometer scale. Thus axicon-based two-photon microscopy has been shown to yield a high-resolution projection image of a sample with a single 2D scan of the laser beam while maintaining the improved tissue penetration typical of two-photon microscopy.

Equipment Design↗

Long-depth imaging of specific gene expressions in whole-mount mouse embryos with single-photon excitation confocal fluorescence microscopy and FISH.

Long-depth imaging of specific gene expression in the midgestation whole-mount mouse embryo (WME) is demonstrated with single-photon excitation (1PE) confocal fluorescence microscopy and fluorescence in situ hybridization. Expression domains of Pax-6 mRNA transcripts were labeled with an in situ hybridization probe that is a RNA sequence complementary to the cloned gene fragment and were rendered visible using two fluorochrome-conjugated antibodies that fluoresce at peak wavelengths of lambda(F) = 0.525 microm and lambda(F) = 0. 580 microm, respectively. Distributions of Pax-6 mRNA domains as deep as 1000 microm in the day 9.5 WME were imaged with a long-working-distance (13.6 mm) objective lens (magnification 5x). The scattering problem posed by the optically thick WME sample is alleviated by careful control of the detector pinhole size and the application of simple but fast postdetection image enhancement techniques, such as space and wavelength averaging to produce high-quality fluorescence images. A three-dimensional reconstruction that clearly shows the Pax-6 mRNA expression domains in the forebrain, diencephalon, optic cup, and spinal cord of the day 9.5 WME is obtained. The advantages of 1PE confocal fluorescence imaging over two-photon excitation fluorescence imaging are discussed for the case of long-depth imaging in highly scattering media. Imaging in midgestation WMEs at optical depths of more than 350 microm has not yet been realized with two-photon fluorescence excitation.

Animals↗

Total internal reflection fluorescence microscopy in single molecule nanobioscience.

Recent development in total internal reflection fluorescence microscopy (TIRFM) has made it possible to directly monitor the behaviors of biomolecules at the single-molecule level both in vitro and in living cells. This technique has opened a new era in bioscience, so-called single-molecule nanobioscience. In this review, we will summarize the theoretical basis of TIRFM, explain the instruments of TIRFM for single-molecules imaging, and discuss some novel applications of TIRFM to single-molecule nanobioscience.

Equipment Design↗

Dynamics of cell membranes and the underlying cytoskeletons observed by noninterferometric widefield optical profilometry and fluorescence microscopy.

Combining the noninterferometric wide-field optical profilometry technique with fluorescence microscopy, we observe the membrane activities of a living cell as well as the structures of its cytoskeletons. The membrane ripples of a lamellipodium are related to similar structures of the underlying actin filaments. However, we find the ripples appear prior to and disappear later than the corresponding actin filament structures, which supports the elastic Brownian ratchet model of cell motility. In addition, we measure the three-dimensional movement of a fibronectin-coated latex bead on the membrane. The bead motion is determined by the movement and branching of the actin molecules on the filament, as well as by the displacement of the filament itself.

3T3 Cells↗

Measurement of drug distribution in vascular tissue using quantitative fluorescence microscopy.

Quantitative tools to assess vascular macromolecular distributions have been limited by low signal-to-noise ratios, reduced spatial resolution, postexperimental motion artifact, and the inability to provide multidimensional drug distribution profiles. Fluorescence microscopy offers the potential of identifying exogenous compounds within intact tissue by reducing autofluorescence, the process by which endogenous compounds emit energy at the same wavelength as fluorescent labels. A new technique combining fluorescence microscopy with digital postprocessing has been developed to address these limitations and is now described in detail. As a demonstration, histologic cross-sections of calf carotid arteries that had been loaded endovascularly with FITC-Dextran (20 kD) ex vivo were imaged at two different locations of the electromagnetic spectrum, one exciting only autofluorescent structures and the other exciting both autofluorescent elements and exogenous fluorescent labels. The former image was used to estimate the autofluorescence in the latter. Subtraction of the estimated autofluorescence resulted in an autofluorescence-corrected image. A standard curve, constructed from arteries that were incubated until equilibrium in different bulk phase concentrations of FITC-Dextran, was used to convert fluorescent intensities to tissue concentrations. This resulted in a concentration map with spatial resolution superior to many of the previous methods used to quantify macromolecular distributions. The transvascular concentration profiles measured by quantitative fluorescence microscopy compared favorably with those generated from the proven en face serial sectioning technique, validating the former. In addition, the fluorescence method demonstrated markedly increased spatial resolution. This new technique may well prove to be a valuable tool for elucidating the mechanisms of macromolecular transport, and for the rational design of drug delivery systems.

Blood Vessels↗

Scanning confocal fluorescence microscopy for single molecule analysis of nucleotide excision repair complexes.

We used scanning confocal fluorescence microscopy to observe and analyze individual DNA- protein complexes formed between human nucleotide excision repair (NER) proteins and model DNA substrates. For this purpose human XPA protein was fused to EGFP, purified and shown to be functional. Binding of EGFP-labeled XPA protein to a Cy3.5-labeled DNA substrate, in the presence and absence of RPA, was assessed quantitatively by simultaneous excitation and emission detection of both fluorophores. Co-localization of Cy3.5 and EGFP signals within one diffraction limited spot indicated complexes of XPA with DNA. Measurements were performed on samples in a 1% agarose matrix in conditions that are compatible with protein activity and where reactions can be studied under equilibrium conditions. In these samples DNA alone was freely diffusing and protein-bound DNA was immobile, whereby they could be discriminated resulting in quantitative data on DNA binding. On the single molecule level approximately 10% of XPA co-localized with DNA; this increased to 32% in the presence of RPA. These results, especially the enhanced binding of XPA in the presence of RPA, are similar to those obtained in bulk experiments, validating the utility of scanning confocal fluorescence microscopy for investigating functional interactions at the single molecule level.

DNA↗

Fluorescence microscopy of etched methacrylate sections improves the study of mitosis in plant cells.

Etched sections of methacrylate infiltrated plant tissue [Gubler (1989) Cell Biol. Int; Rep., 13:137-145; Baskin et al. (1992) Planta, 187:405-413] offer many advantages over the more traditional squash technique of Wick et al. [(1981) J. Cell Biol. 89:685-690] for immunofluorescence microscopic investigation of the plant cytoskeleton, especially during mitosis. These advantages include: (1) unimpeded access of antibody probes, (2) confocal-like imaging without the expense of confocal equipment, (3) maintenance of organ architecture as well as intracellular structure, (4) the ability to independently examine separate focal planes with the same or multiple antibody(s) or other labelling compounds, and (5) the ability to archive unetched sections, polymerized or non-polymerized infiltrated tissue. In this paper examples of staining of various microtubule cytoskeletal and mitotic proteins are shown in a variety of methacrylate embedded plant tissues.

Antibodies, Monoclonal↗

Heterogeneous distribution of fibronectin, tenascin-C, and laminin immunoreactive material in the cumulus-corona cells surrounding mature human oocytes from IVF-ET protocols--evidence that they are composed of different subpopulations: an immunohistochemical study using scanning confocal laser and fluorescence microscopy.

Monoclonal antibodies and immunofluorescence microscopy, including laser confocal microscopy, were used in this study to point out the production of fibronectin, tenascin-c, and laminin in the cumulus-corona (CC) cells surrounding mature human oocytes from IVF-ET protocols in view of their presumptive importance in the coordination of the processes leading to fertilization and early embryo cleavage, including the final maturation of the ovum, the sperm-egg interaction, and the "complex biochemical dialogue" between the gamete and the oviduct through the tubal luminal environment. One hundred fifty mature oocyte-CC complexes were obtained from IVF-ET protocols and fixed in 4.0% buffered paraformaldehyde. Specimens were incubated with a panel of primary monoclonal antibodies (mabs) recognizing different epitopes of fibronectin, tenascin-c, and laminin and then with fluorescein isothiocyanate-conjugated goat anti-mouse IgG. Observations were made by a scanning confocal microscope (Sarastro 2000) and a photomicroscope (Polyvar, Reichert-Jung) equipped with epifluorescence optics. The immunohistochemical data demonstrated that human CC cells are capable of producing fibronectin and tenascin-c but that their production is not homogeneous in the CC population. In fact, fibronectin immunoreactivity was shown mostly by inner CC cells (mainly corona cells), whereas tenascin was produced by some cells scattered in the entire cumulus mass. Moreover, fibronectin and tenascin-c immunoreactive material was observed in the intracytoplasmic areas, at the plasma membrane level as well as in the extracellular matrix. On the contrary, laminin immunofluorescent material was found around plasma membranes of almost all CC cells, but a clear intracytoplasmic reaction was never observed. This leads us to assume that laminin in the extracellular matrix remains entrapped once produced by granulosa follicular cells and that in the postovulatory period no active secretion occurs in CC cells. Even though the functional role of these extracellular matrix proteins remains still unclear, it is reasonable to suggest that they are necessary in various steps of the reproductive process, i.e., from the pick-up of the oocyte, its transport through the oviduct, and fertilization, up until the early cleavage of the embryo. Finally, functional differences between "corona radiata" and "cumulus" cells during the oocyte denudation may be accounted for particular distribution of these adhesive proteins.

Fertilization in Vitro↗

In vivo behaviour of long-circulating liposomes in blood vessels in hamster inflammation and septic shock models-use of intravital fluorescence microscopy.

This study aimed to observe liposome uptake by leukocytes in vivo. The study was performed on skin by using a dorsal skin-fold chamber implanted in golden hamsters using intravital microscopy. 5 and 6-CF-encapsulated polyethylene glycolated liposomes were injected intravenously. The skin microcirculation was observed with an intravital Eclipse E800 Nikon microscope (using x40, x80 magnification) fitted with a Xenon light source and an epifluorescence assembly (excitation, 470 nm, FWHM 40 nm; emission, 540 nm, FWHM 40 nm). An ultra-high sensitivity videocamera mounted on the microscope projected the image onto a monitor, and the images (720 x 576 pixels) were recorded for playback analysis with a digital video cassette recorder. An acute inflammatory response was obtained by removing one complete layer of skin and the underlying fascia and avascular tissue on the opposing side of the flap corresponding to an area equivalent to the window aperture. Using this model and set-up, leukocyte rolling and adhesion were easily observed and the entry of PEGylated liposomes into hamster blood leukocytes was studied for a period of 6 h. PEGylated liposomes were clearly identified alone inside the blood flow and inside the leukocytes as soon as the inflammatory reaction appeared. This study shows for the first time that blood leukocytes in their natural milieu of whole blood are capable of interacting with, and taking up, liposomes. This observation is in accordance with previous in vitro studies.

Animals↗

Automated neurite labeling and analysis in fluorescence microscopy images.

BACKGROUND: To investigate the intricate nervous processes involved in many biological activities by computerized image analysis, accurate and reproducible labeling and measurement of neurites are prerequisite. We have developed an automated neurite analysis method to assist this task. METHODS: Our approach can be considered as automated with certain user interaction in setting initial parameters. Single and connected centerlines along neurites are extracted. The computerized method can also generate branching and end points. Owing to its multi-scale flexibility, both thick and thin neurites are simultaneously detected. RESULTS: We employ the relative neurite length difference (defined as the difference between the lengths obtained by automated and manual analysis divided by the total length of the latter) and neurite centerline deviation (defined as the area of the regions enclosed by different paths between automated and manual analysis divided by the total length of the former) to evaluate the performance of our algorithm, which is of great interest in neurite analysis. The average of the relative length difference is about 0.02, while the average of the centerline deviation is about 2.8 pixels. The probabilities of the distributions being the same from the Kolmogorov-Smirnov (KS) test of the automatic and manual results are 99.79%. The KS test also shows no significant bias between different observers based on the proposed new validation scheme. CONCLUSIONS: With the accurate and automated extraction of neurite centerlines and measurement of neurite lengths, the proposed method, which greatly reduces human labor and improves efficiency, can serve as a candidate tool for large-scale neurite analysis beyond the capability of manual tracing methods.

Algorithms↗