Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DENTURE BASES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Repair of denture base resin using woven metal and glass fiber: effect of methylene chloride pretreatment.

STATEMENT OF PROBLEM: A durable repairing system for denture base fracture is desired to avoid recurrent fracture. Purpose. This study evaluated the strength and modulus of elasticity of repaired acrylic specimens reinforced with various processes. MATERIAL AND METHODS: Transverse strength and modulus of elasticity of repaired acrylic denture base specimens were evaluated with a 3-point bending test and compared with a heat-polymerized control. Autopolymerizing acrylic resin was used with woven metal fiber and glass fiber with and without methylene chloride surface treatment (n = 6 per group). The specimens were cut in half and fixed in a metal mold to obtain a space for placing the repairing resin. A cavity was prepared when metal or glass fiber was used. All specimens were stored in 37 degrees C distilled water for 48 hours before the test. All data were statistically analyzed with 1-way ANOVA, and differences among groups were analyzed with Fisher test (P< or =.05). RESULTS: The mean value of the transverse strength for the control was 87.2 MPa. The specimens repaired by glass fiber with methylene chloride surface treatment exhibited the highest transverse strength (96.8 MPa), which was significantly higher than that of the control (P< or =.05). The elastic modulus of the specimens repaired by glass fiber with methylene chloride surface treatment (4189.3 MPa) was significantly greater than that of the control (2683.7 MPa) at a 95% level of confidence. The values of transverse strength and elastic modulus were highest when the surface treatment was combined with a reinforcing glass fiber. CONCLUSION: Reinforcement with glass fiber and methylene chloride pretreatment produced transverse strength and a modulus of elasticity higher than the control.

Acrylic Resins↗

Tensile bond strength of a soft lining with acrylic denture base resins.

Bonding of different soft lining materials has been widely investigated, but there is little work on the effect of using different denture base resins. This study investigates the bonding of Molloplast-B (a heat-cured, silicone soft lining material) and five commercial acrylic denture base materials of different types (Pacton, Lucitone, Meliodent, Ivocap and Compresin). The lining was processed against all the resins cured and Pacton, Lucitone and Meliodent uncured. In the cured specimens, Lucitone, Meliodent and Compresin demonstrated cohesive failure, whereas Pacton and Ivocap demonstrated part-adhesive and part-cohesive failure. All three sets of uncured specimens demonstrated adhesive failure. It was concluded that pre-curing, roughening and treating with Primo adhesive gives a better bond.

Acrylic Resins↗

The effect of cross-linking agents on the impact resistance of a linear poly(methyl methacrylate) denture-base polymer.

Eight different cross-linking agents were added to the monomer component of a linear poly(methyl methacrylate) denture-base resin in various concentrations, and their effect on the impact resistance of the cured polymer studied. The cross-linking agents were chosen to provide a range of cross-linking chain lengths and degrees of chain flexibility. When tested under oral conditions, the polymers cross-linked with long and flexible chains did not show the marked reduction in impact resistance found in polymers cross-linked with shorter and stiffer cross-linking chains. It seems likely that by replacing EGDMA in denture-base resins with a cross-linking agent such as PEG 600 DMA, one could use a higher concentration with a consequent improvement in solvent resistance.

Composite Resins↗

The effects of surface machining on heat cured acrylic resin and two soft denture base materials: a scanning electron microscope and confocal microscope evaluation.

STATEMENT OF PROBLEM: Rough surfaces promote the adhesion and colonization of denture plaque, therefore it is important to know the character of the surface left by rotary instruments on denture base materials. As a single microscopic technique can introduce artifact, complementary microscope techniques need to be used. PURPOSE: This study investigated the surface characteristics of the machined surfaces of heat-cured acrylic resin, Molloplast B and Novus. MATERIAL AND METHODS: Scanning electron microscopy and confocal microscopy were used to investigate surfaces that had been prepared with appropriate clinical rotary instruments. Thirty samples of each material were prepared with steel and tungsten carbide burs, Molloplast stones, and Arbor bands. An analysis of variance, with the Scheffe multiple comparison of means test, was used to compare average surface roughness of the individual surfaces. RESULTS: The tungsten carbide bur produced a smoother nongrooved surface than the steel bur on acrylic resin. The roughest surfaces were produced on the soft lining materials by the Arbor band and Molloplast stone. CONCLUSIONS: The confocal microscope is a valuable complementary instrument to scanning electron microscopy and provides surface roughness data by using a noncontact method. Each type of rotary instrument produces its own characteristic surface on denture base materials.

Acrylic Resins↗

Abrasion resistance of microwave-curing denture base resin.

This study was designed to test the abrasion resistance of microwave-curing denture base resin. We also studies the effects of surface smoothing treatment on abrasion resistance. Test resin was allowed to polymerize, and then buff polished or treated by surface smoothing. Knoop hardness was measured both prior to and following surface treatment. Then, the test material was subjected to brushing using a newly developed toothbrushing machine. Volume and surface roughness of the material were measured before and after brushing, and the surface structure of the material was examined with SEM. Microwave-curing denture base resin is equal in Knoop hardness and abrasion resistance to its conventional heat-curing counterpart, although it is smoother at the surface. The resin improved both in hardness and abrasion resistance when it underwent surface smoothing treatment regardless of whether it was heat-cured or microwave-cured. As was evident from SEM observations that both types of resins suffered superficial chipping following severe brushing, which is in accordance with our previous clinical findings.

Acrylic Resins↗

Cytotoxicity of denture base acrylic resins: a literature review.

Acrylic resins are widely used in the fabrication of denture bases and have been shown to be cytotoxic as a result of substances that leach from the resin. The primary eluate is residual monomer. Numerous reports suggest that residual monomer may be responsible for mucosal irritation and sensitization of tissues. This information is important, not only to assess the biologic effects of such materials, but also to enable a comparison among the different polymerization methods, thus assisting the clinician in selecting a material with minimal cytotoxicity. This article reviews the literature published from 1973 to 2000, selected by use of a Medline search, associated with cytotoxic effects usually ascribed to acrylic denture base materials.

Acrylic Resins↗

Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin.

PURPOSE: This study compared the linear dimensional changes of 3 injection-molded denture base materials to that of conventionally processed polymethylmethacrylate (PMMA) resin. MATERIALS AND METHODS: An impression of an aluminum maxillary edentulous arch was made with a condensation silicone impression material (Denture Elasticon) to fabricate a gypsum master cast that was replicated as a silicone mold. A maxillary complete denture with acrylic teeth was waxed to full contour on the master cast and replicated to make 40 wax dentures. ERA attachments cast in metal (Rexillium) with indices milled into the centers were waxed into 3 positions in each denture for recording dimensional measurements of the wax denture. Ten dentures were allocated to each of 4 groups; Group 1 was processed using conventionally processed PMMA (Microlon), Group 2 used injection-molded PMMA (SR-lvocap), Group 3 employed injection-molded nylon (Valplast), and Group 4 used injection-molded styrene (Northern). All processed specimens were stored at room temperature (25 degrees C, ambient humidity) for 1 week (while still on the master cast) before anteroposterior and cross-arch measurements were made using the ERA reference points with a digital caliper. After separation from the master cast and following water storage at 37 degrees C for 7 days additional measurements were made. RESULTS: An analysis of the results showed that the effect of processing was not the same for the 3 dimensions studied, regardless of which dimension was considered (p < 0.0001). The pattern of dimensional changes associated with the material type was not the same between the wax and processing stages as it was for the change between the processing and decasting stages (p < 0.0001). CONCLUSIONS: Processing the denture base materials produced unequal deformation in different dimensions (anterior-posterior and cross-arch). Each material tested also responded differently to the processing stages.

Acrylic Resins↗

An investigation of the variables which may affect the bond between plastic teeth and denture base resin.

OBJECTIVES: The failure of the bond between acrylic resin denture base material and resin teeth remains a significant problem. This study evaluated the tensile bond strength of specimens produced by commonly employed tooth preparation and processing methods as used in dental laboratories. METHODS: Twenty-two experimental groups, each consisting of 36 specimens, were investigated by subjecting the tooth-resin bond to tensile loading. The groups were allocated to one of five experimental sets to investigate: (a) effect of resin dough time, (b) effect of tooth surface condition, (c) effect of processing variables, (d) effect of monomer cementing, and (e) effect of acrylic resin cement. The results were analysed statistically using a one factor ANOVA and a Student t test. RESULTS: A significantly stronger bond was obtained when the resin was packed late in the dough stage, and a superior bond, in all cases, when high-impact resin was used. Tooth surface modification by grinding or grooving made no significant difference when compared with unmodified surfaces. Wax-contaminated surfaces produced highly significant weaker bonds. Time of introduction and duration of water-bath processing had no significant effect on bond strength. Monomer cementing of the tooth surface, especially with high-impact monomer. significantly improved the bond strength. The application of resin cements was found to produce the most significant increase in denture tooth bond strength. CONCLUSIONS: The important steps in obtaining a consistently high value denture tooth bond are thorough dewaxing of the tooth surface followed by the application of a suitable resin cement.

Acrylic Resins↗

Creep and hardness testing of some denture base polymers.

A method of measuring creep, recovery, hardness, and the effect of cyclic loading on denture base polymers using a modified Wallace hardness tester is described. This apparatus is particularly sensitive and is capable of detecting very small variations in these properties of the materials. A representative group of denture base polymers that include heat-cured, pour-type, and other modified materials was tested. The results obtained are in good agreement with those shown by other workers.

Denture Bases↗

Dynamic viscoelastic properties of models composed of posterior denture teeth and denture base resin.

The purpose of this investigation was to compare the dynamic viscoelastic properties of various models composed of denture teeth and heat-cured denture base resin. The specimens were porcelain and resin teeth mounted in denture base resin. Compressive dynamic stiffness and phase differences were measured with a viscoelastic spectrometer. Measurements of the viscoelastic frequency spectrum based on the fast Fourier transform of displacement to applied random forces were analyzed with a spectrum analyzer. The stiffness of the specimens was independent of the frequency. The stiffness of the porcelain specimens was higher than that of the resin ones measured under the same conditions. The phase lag of the specimens was dependent on the frequency. The phase lag of the porcelain specimens was lower than that of the resin ones measured under the same conditions. This study suggested that the acrylic resin teeth had greater toughness and higher shock-absorbing ability than the porcelain teeth, and that the porcelain teeth were more brittle than the acrylic resin ones, whether the teeth were isolated or in dentures.

Acrylic Resins↗

Visco-elastic properties of pour (fluid) denture base resins.

A number of pour-type denture base resins were found to have low glass transition temperatures, indicating a propensity to thermal distortion. These low transition temperatures reflected high residual monomer contents. Furthermore, such materials exhibited high mechanical loss tangents, consistent with high creep rates observed previously.

Acrylic Resins↗

The significance of major connectors and denture base mucosal contacts on the functional strain patterns of maxillary removable partial dentures.

The purpose of this study was to investigate the biomechanical significance of major connectors and base mucosal contacts on the mechanical behaviour of maxillary removable partial dentures in vivo. Six subjects wearing maxillary dentures retained by conical crowns were selected for the study. Reflective photoelasticity and strain gauges were used to monitor the development of strain/stress during functional loading. Loading tests were performed initially with a denture design including a palatal major connector and denture bases and then repeated after removal of the major connectors and denture base alveolar muccosa contacts. The palatal major connector and the denture bases mucosal contacts contribute significantly to the rigidity and stability of removable partial dentures retained by conical crowns.

Aged↗

The effect of diabetes mellitus on histopathological changes in the tissues under denture base bearing masticatory pressure.

The effect of streptozotocin-induced diabetes mellitus on histopathological changes in tissues bearing masticatory pressure exerted through an experimental denture base has been studied in animal specimens. Experimental dentures, which prescribed the masticatory pressure by the amount of subsidence of the denture base (100, 50 or 13 microm), were constructed for the hard palate of the molar regions of rats. It was revealed that streptozotocin-induced diabetes mellitus (1) weakened the intercellular junctions in the epithelium and gradually enhanced this state with time, (2) lessened the atrophic and proliferative reactions in the epithelial ridge and prolonged their appearance period, (3) enhanced the compression of lamina propria mucosae and prolonged the appearance period of this reaction, (4) enhanced the inflammatory change and extended its appearance period, (5) lowered the threshold for the inflammatory reaction induced by the masticatory pressure, (6) increased the number of osteoclasts and prolonged the period of their presence, (7) lowered the threshold for osteoclastic bone resorption induced by the masticatory pressure, (8) inhibited the appearance of osteoblasts following the disappearance of osteoclasts and (9) accelerated the decline rate of masticatory pressure exerted to the denture supporting tissues. Therefore, it can be concluded that the streptozotocin-induced diabetes mellitus in the animals tested deteriorated the tolerance of the denture supporting tissues to masticatory pressure.

Alveolar Bone Loss↗

Flexure fatigue of 10 commonly used denture base resins.

The flexure fatigue properties of 10 denture base resins (four different types) were tested. Each specimen underwent two-way testing in a water bath maintained at 37 degrees +/- 1 degree C. A load of 3,650 gm was applied a 342 flexures per minute until the specimen broke. The resin types listed in order of increasing resistance to flexure fatigue are polymethylmethacrylate (PMM) pour resins, PMM thermosetting resins, vinyl resins, and a PMM grafted resin. Although small samples size and scatter of results limit broad application of this data, it is of some significance that the grafted resin Lucitone 199 tended to withstand repeated flexure when compared to the other resins.

Dental Stress Analysis↗

The effects of cross-linking agents on the water sorption and solubility characteristics of denture base resin.

Six different cross-linking agents were added to the monomer component of an autopolymerizing denture base resin, and their effects on the water sorption and solubility were investigated. The results of this study suggested that the chemical nature of the polymer versus that of the water molecule directly affected the water sorption of denture base resin. The addition of a cross-linking agent decreased the solubility with increasing concentration.

Acrylic Resins↗

Effect of glass fiber reinforcement on the flexural strength of different denture base resins.

OBJECTIVE: Different types of fibers have been added to polymer materials to improve their mechanical properties. Glass fibers have been used in either continuous or woven form as a strengthening material. The aim of this study was to investigate the effect of a new glass fiber reinforcement system on the flexural strength of three different denture base resins (heat polymerized, autopolymerized, and photopolymerized). METHOD AND MATERIALS: Ninety specimens were formed in a specially designed mold to produce identical specimens in accordance with each manufacturer's recommendations. RESULTS: The fibers of Stick and Stick Net were well impregnated with the resin of polymer matrix. Stick and Stick Net reinforcement significantly enhanced the flexural strength of the tested specimens. In all groups, specimens reinforced with Stick glass fibers exhibited the highest flexural strength, followed by Stick Net glass fibers. The control group specimens without fiber exhibited the lowest values. CONCLUSION: The process of reinforcement of denture base resins with glass fiber may be a useful means of strengthening denture bases beyond their normal limits.

Acrylic Resins↗

Color change in acrylic denture base resin reinforced with wire mesh and glass cloth.

In this study, the L*a*b* color system as a color system and light transmittance of the denture base resin reinforced with wire mesh and glass cloth were measured, and the color difference (deltaE*ab) was calculated using L*, a* and b* values which were measured both on a white calibration plate and on a null background. The thicknesses of test specimens, which were reinforced with wire mesh and glass cloth 0.5 and 1.0 mm below the surface, were 3 and 5 mm. L*, a* and b* values of wire mesh reinforcing specimens decreased in comparison with the non-reinforcing specimens (p<0.05). L* values of glass cloth-reinforcing specimens increased compared with the non-reinforcing specimens (p<0.05). The glass cloth is an effective reinforcing material and an aesthetically important property of denture base resin, since wire mesh makes the resin appear darker with the background condition greatly altering the color, while glass cloth makes the resin lighter.

Acrylic Resins↗