LCD versus CRT displays: a comparison of visual search performance for colored symbols.

Visual search performance for tactical symbols was examined with liquid-crystal (LCD) and cathode-ray tube (CRT) displays. Twenty-four adult participants (19 men, 5 women; mean age 41 years) searched for navy tactical display symbols on a map background. LCD and CRT displays of similar size and resolution (52 cm diagonal, 1280 x 1024 pixels) were used. Viewing angle (0 degrees vs. 60 degrees of azimuth), set size, target color (blue, red, or white), target presence, and search type (feature vs. conjunction) were also manipulated. Participants showed reduced sensitivity for red and blue symbols viewed 60 degrees off axis with the LCD relative to on-axis LCD, or to the CRT on or off axis. Colored symbols viewed off axis on the LCD produced longer response times in feature search and lower search efficiency in conjunction search. The results argue against the use of current LCD technology when off-axis viewing is likely and color coding is used.

Adult↗

Entrainment to video displays in primary visual cortex of macaque and humans.

Cathode ray tubes (CRTs) display images refreshed at high frequency, and the temporal waveform of each pixel is a luminance impulse only a few milliseconds long. Although humans are perceptually oblivious to this flicker, we show in V1 in macaque monkeys and in humans that extracellularly recorded action potentials (spikes) and visual-evoked potentials (VEPs) align with the video impulses, particularly when high-contrast stimuli are viewed. Of 91 single units analyzed in macaque with a 60 Hz video refresh, 29 cells (32%) significantly locked their firing to a uniform luminance display, but their number increased to 75 (82%) when high-contrast stimuli were shown. Of 92 cells exposed to a 100 Hz refresh, 21 (23%) significantly phase locked to high-contrast stimuli. Phase locking occurred in both input and output layers of V1 for simple and complex cells, regardless of preferred temporal frequency. VEPs recorded in humans showed significant phase locking to the video refresh in all seven observers. Like the monkey neurons, human VEPs more typically phase locked to stimuli containing spatial contrast than to spatially uniform stimuli. Phase locking decreased when the refresh rate was increased. Thus in humans and macaques phase locking to the high strobe frequency of a CRT is enhanced by a salient spatial pattern, although the perceptual impact is uncertain. We note that a billion people worldwide manage to watch TV without obvious distortion of their visual perception despite extraordinary phase locking of their V1s to a 50 or 60 Hz signal.

Action Potentials↗

Complementary scanning electron microscopy: technical notes and applications.

This report introduces practical techniques and applications of complementary scanning electron microscopy (SEM). To identify the complementary structures at high magnification, we first made a montage pair of low magnification micrographs as a guide map. Consulting the map, we took complementary micrographs at high magnification. When taking a picture at high magnification, we drew the outline of the most prominent structures on a transparent plastic plate attached to the cathode-ray tube of a SEM. Then another picture of the complementary structures was taken after adjusting the complementary structures to the reverse image of the plastic plate. We performed three applications of the complementary SEM: 1) complementary observation of the epithelial underside and lamina propria of the rat urinary bladder; 2) complementary observation of the fractured Golgi apparatus; and 3) evaluation of specimen drying methods. After proper digestion of the rat urinary bladder using strong alkali, the epithelium was detached from the underlying lamina propria. On the basal side of the epithelium, the meshwork of grooves were visible. The observation of the corresponding lamina propria confirmed that the grooves were occupied by blood capillaries located in the uppermost part of the lamina propria. The complementary observation of the Golgi apparatus was useful for understanding its three-dimensional architecture. The observation on both complementary fractured surfaces of the Golgi apparatus from the mouse lacrimal gland demonstrated the continuity of the Golgi stacks. It was also effective for observing both the cis and trans side of the same Golgi stack. Complementary SEM was also useful for evaluating the specimen drying method.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Assessing the image quality of a CCD-based digital intraoral radiography system: application of perceptibility curve test.

The perceptibility curve test is a method for evaluating the psychophysical properties of radiographic systems. The concept of the perceptibility curve is based on the minimum perceptible exposure differences that are recorded by a particular imaging system. The perceptibility curve test was applied to a Charge-Coupled Device (CCD)-based digital intraoral radiography system in this study. A test object was made of a square aluminum block, 28 mm in both height and length and 10 mm in thickness. The test object had ten contrast details in the form of round holes with diameters of 1.5 mm. The depths of the holes ranged from 0.05 mm to 0.5 mm in steps of 0.05 +/- 0.01 mm. An X-ray unit was used that operated in the range of 60 to 90 kVp. Test radiographs were shown to observers in random order. Six observers were asked to rate them regarding the number of spots representing holes that they could perceive. The smallest perceptible difference in gray level on the computer monitor, a 15-inch cathode-ray tube (CRT), was then found. The minimum difference in gray level between a perceptible detail and the background was determined. Dose response functions were employed to determine exposures corresponding to these gray levels. For each case, delta logE as a function of the number of object details was calculated. Finally the reciprocal of all values of (delta logE)min were calculated. The number of details which the observers perceived decreased linearly with decreasing delta logE values. The maximum number of details that observers perceived was eight or nine. The perceptibility curves showed that their peaks shifted slightly with a change of the kVp but that their shapes were similar at different kVp settings.

Color↗

Digital imaging modalities for dental practice.

The introduction of the computed tomograph in the 1970s revolutionized medical diagnosis by initiating the transition from analogue to digital imaging. During this period, more specialized equipment for image processing was developed, such as cathode-ray tubes for image display, special sensors for image acquisition, and storage devices for image archiving. Digital imaging systems designed exclusively for use in dentistry were developed in the latter half of the 1980s. Some are now being clinically applied under conditions of close scrutiny to determine diagnostic accuracy, image quality, and radiation exposure to patients. This article reviews the enabling technologies of digital systems used in dentistry, and focuses upon intraoral digital imaging systems, concepts for digital image acquisition, and variations in radiation dose and their effects on diagnostic accuracy of caries detection.

Data Display↗

Full-field digital mammography on LCD versus CRT monitors.

OBJECTIVE: Our purpose was to determine if the display of full-field digital mammograms on a 5-megapixel liquid crystal display (LCD) monitor is at least equivalent to the display of the same on a 5-megapixel cathode ray tube (CRT) monitor. MATERIALS AND METHODS: Five radiologists evaluated normal anatomy and features of 61 abnormalities in 48 full-field digital mammograms. A 9-point Likert scale was used to compare images on two identical soft-copy review workstations, one equipped with two 5-megapixel CRTs and the other with two 5-megapixel LCDs. Outcomes were evaluated using a random-effects analysis of variance model. Means and SEs were reported. Ninety-five percent confidence intervals and p values were calculated. RESULTS: The two systems were equivalent for most features. The LCDs were rated better for the sharpness of mass margins (p = 0.011) and mass conspicuity (p = 0.050). For calcium features, the LCDs were rated better than the CRTs for lesion conspicuity (p = 0.010) and number of calcifications (p = 0.043). For architectural distortions, there was no statistically significant difference between the monitors in any of the features evaluated. For display characteristics, the LCDs were better for luminance (p = 0.021). The CRTs were significantly better for image noise (p = 0.001). In the overall ratings, there was no statistically significant difference between the two displays. CONCLUSION: The 5-megapixel monochrome active-matrix LCD is equivalent to and in some respects better than the 5-megapixel CRT display for full-field digital mammograms over a range of normal and abnormal findings.

Breast Neoplasms↗

High-resolution computer display of portable, digital, chest radiographs of adults: suitability for primary interpretation.

OBJECTIVE: The suitability of using a high-resolution computer-display system for primary interpretation of adult chest radiographs obtained with portable apparatus and storage phosphor technology was evaluated with receiver operating characteristic analysis and subjective methods. MATERIALS AND METHODS: Sixty portable digital chest radiographs showing abnormalities that approached the resolution limits of our computed radiography system were selected. The original digital data making up the 2140 x 1760 x 10 bit images were transferred to a cathode ray tube (CRT) display system composed of two Megascan monitors. Postprocessing rendered two images, one for each monitor, to emulate the two-on-one hard-copy format produced by the computed radiography system. Each image set was interpreted independently by three radiologists experienced with hard-copy format. Limited level and window adjustments were allowed during CRT interpretation. For both CRT and hard-copy display, images were graded on the basis of the interpreter's confidence in the presence of pneumothorax and parenchymal abnormalities. Three types of foreign devices were subjectively analyzed: endotracheal tubes, nasogastric tubes, and temporary epicardial pacer wires. RESULTS: No significant differences were found in detecting pneumothorax or focal infiltrates. One radiologist found the hard copy better for detecting diffuse infiltrates (p = .02); two radiologists favored CRT for visualizing nasogastric tubes (p < .005, p < .02); and one radiologist favored CRT for visualizing temporary epicardial pacer wires (p = .05). CONCLUSION: We conclude that an optimized high-resolution CRT system is quite promising for primary interpretation of digital portable chest radiographs, but further investigation and greater statistical power are necessary to confirm our results.

Adult↗

Impact of ambient light and window settings on the detectability of catheters on soft-copy display of chest radiographs at bedside.

OBJECTIVE: The aim of this study was to evaluate how ambient light and interactive adjustment of density and contrast affect the detection of catheter fragments when interpreting bedside chest radiographs on soft-copy displays. MATERIALS AND METHODS: A total of 131 catheter fragments were superimposed over 10 bedside chest radiographs obtained with storage phosphor technology. Images were displayed on a clinical intensive care unit viewing station (color cathode-ray tube monitor, 21 inch [53 cm], 1280 x 1024 matrix) and were independently evaluated by five radiologists. The number of catheter fragments per image varied between 12 and 14, with an approximately equal distribution in high- and low-absorption areas. Detectability of catheter fragments was assessed under subdued and bright ambient light conditions with and without interactive adjustment of window width and level. RESULTS: Under subdued light, the detection rate of catheter fragments was significantly higher than under bright light (51.8% vs 56.6%, p < 0.05). Interactive window setting adjustment significantly increased the detection rate from 52.5% to 60.8% (p < 0.05) under subdued light and from 47.9% to 55.6% (p < 0.05) under bright light. With adjustment of window settings, the difference between the detection rates under subdued light (60.8%) and under bright light (55.6%) did not reach statistical significance. CONCLUSION: Detection of catheters on soft-copy display is significantly decreased by bright ambient light, an effect that can be largely compensated for by means of interactive adjustment of window settings.

Analysis of Variance↗

Radiologists' performance for differentiating benign from malignant lung nodules on high-resolution CT using computer-estimated likelihood of malignancy.

OBJECTIVE: The purpose of our study was to evaluate whether a computer-aided diagnosis (CAD) scheme can assist radiologists in distinguishing small benign from malignant lung nodules on high-resolution CT (HRCT). MATERIALS AND METHODS: We developed an automated computerized scheme for determining the likelihood of malignancy of lung nodules on multiple HRCT slices; the likelihood estimate was obtained from various objective features of the nodules using linear discriminant analysis. The data set used in this observer study consisted of 28 primary lung cancers (6-20 mm) and 28 benign nodules. Cancer cases included nodules with pure ground-glass opacity, mixed ground-glass opacity, and solid opacity. Benign nodules were selected by matching their size and pattern to the malignant nodules. Consecutive region-of-interest images for each nodule on HRCT were displayed for interpretation in stacked mode on a cathode ray tube monitor. The images were presented to 16 radiologists-first without and then with the computer output-who were asked to indicate their confidence level regarding the malignancy of a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: The area under the ROC curve (Az value) of the CAD scheme alone was 0.831 for distinguishing benign from malignant nodules. The average Az value for radiologists was improved with the aid of the CAD scheme from 0.785 to 0.853 by a statistically significant level (p = 0.016). The radiologists' diagnostic performance with the CAD scheme was more accurate than that of the CAD scheme alone (p < 0.05) and also that of radiologists alone. CONCLUSION: CAD has the potential to improve radiologists' diagnostic accuracy in distinguishing small benign nodules from malignant ones on HRCT.

Diagnosis, Differential↗

Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer preference study.

OBJECTIVE: Our objective was to compare cathode ray tube (CRT) display with liquid crystal display (LCD) for soft-copy viewing of chest radiographs in a clinical setting. MATERIALS AND METHODS: We displayed 80 posteroanterior digital chest radiographs side by side on a 5-megapixel CRT display and a 3-megapixel LCD. Gradation characteristics of both monitors were adjusted to DICOM display standards. Using a 4-point scale, seven radiologists ranked overall image quality and visibility of anatomic landmarks. Data analysis included Wilcoxon's rank sum test to assess the significance of preference for the different display modes and calculation of the percentage of images ranked equally by at least five of the seven radiologists. RESULTS: Wilcoxon's rank sum test found significant preferences (p < 0.001) for the CRT display for visualization of structures in low-attenuation areas of the thorax and for the LCD for visualization of structures in high-attenuation areas of the thorax. Overall image quality was ranked equal by at least five radiologists in 70% of cases, whereas for the remaining images a significant preference was found for the CRT display. CONCLUSION: We conclude that, under subdued ambient lighting conditions and without use of windowing, for most images the overall quality is equal with high-resolution CRT display and LCD. In images judged preferentially, we found a significant superiority for LCD for delineating mediastinal structures and for CRT display for delineating structures in the lung.

Computer Terminals↗

Stimulus length and orientation variables interact in peripheral motion perception.

To determine the effects of stimulus length and orientation on the perception of motion, 5 experienced subjects responded with a simple reaction to accelerating lines in peripheral vision while fixating on a reference cross at the center of a cathode-ray tube. Three experimental variables were involved: (a) line length, (b) direction of motion, and (c) orientation of the line with respect to the motion. Simple reaction time (RT) was significantly longer for vertical than for horizontal motion and for lines oriented in-line with the direction of motion than for lines oriented perpendicular to the direction of motion. A significant interaction was found between line length and orientation. The results show that the generalization that RT is shorter for small objects than for large objects must be modified in terms of the orientation of the object.

Adult↗

Psychology of computer use: XXX. Effects of presentation speed on pupil size using negative and positive CRTS.

The effects of presentation speed and both positive and negative CRT (cathode ray tube) displays on pupil size were studied. The pupillary areas of 12 female student volunteers were measured by infrared videopupillography. The three presentation speeds were no change for 12 sec., a change every 2 sec. for 12 sec., and a change every 1/2 sec. for 12 sec. Two-way analysis of variance showed that the pupil size in the negative displays was significantly larger than that in the positive displays. A difference in pupillary area results from different display speeds, irrespective of a difference in polarity.

Adult↗

A quantitative test of optokinetic nystagmus and its data processing by computer.

A quantitative test of optokinetic nystagmus was proposed. Horizontal nystagmus was examined by a large rotating cylinder with vertical stripes. Nystagmus responding to the cylinder rotation with an acceleration of 2 degrees/sec2 for 90 seconds was recorded with an electronystagmograph. On the records, the number of beats, average eye-speed, and average amplitude per each 10 seconds were calculated. This method was suitable for testing the nature of optokinetic nystagmus which indicates the ability of the eyes to adapt to objects moving through the visual field. Moreover, in order to save trouble in hand-scoring of each parameter of nystagmus, computer processing of electronystagmographic data was introduced. The results were printed numerically on the teletypewriter, and displayed graphically on a cathode ray tube and X-Y recorder. By displaying measured values on the form already printed with the normal ranges, the evaluation of the results was performed readily and objectively.

Adolescent↗

A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope.

A computer-based system has been developed for the integration and display of computerized tomography (CT) image data in the operating microscope in the correct perspective without requiring a stereotaxic frame. Spatial registration of the CT image data is accomplished by determination of the position of the operating microscope as its focal point is brought to each of three CT-imaged fiducial markers on the scalp. Monitoring of subsequent microscope positions allows appropriate reformatting of CT data into a common coordinate system. The position of the freely moveable microscope is determined by a non-imaging ultrasonic range-finder consisting of three spark gaps attached to the microscope and three microphones on a rigid support in the operating room. Measurement of the acoustic impulse transit times from the spark gaps to the microphones enables calculation of those distances and unique determination of the microscope position. The CT data are reformatted into a plane and orientation corresponding to the microscope's focal plane or to a deeper parallel plane if required. This reformatted information is then projected into the optics of the operating microscope using a miniature cathode ray tube and a beam splitter. The operating surgeon sees the CT information (such as a tumor boundary) superimposed upon the operating field in proper position, orientation, and scale.

Evaluation Studies as Topic↗

A multichannel PC tachistoscope with high resolution and fast display change capability.

The number of channels that PC tachistoscopes can have has increased recently (Bokhorst, 1995; Myors, 1998); however, neither the quality of display nor speed of image switching has been improved. This article shows the capability of VESA's VBE 3.0 standard (1998) for increasing the number of channels of high-quality images. And the refresh rate can be set to the fastest cathode ray tube (CRT) scanning rate the monitor can tolerate in order to reduce the timing delay of changing display. A PCTSCOPE library was written in C to provide these capabilities, which is compatible with conventional DOS real mode. The PC tachistoscope can have numbers of channels with various resolutions and colors and different refresh rates. For example, 25 images with the resolution of 640 x 480 pixels and 256 colors can be loaded to video memory, and vertical refresh rate can be set to 180 Hz. It takes less than 6 msec to change the display among 25 channels in synchronizing with the start of the video scanning frame. In this library, the number of channels, the resolution of the images, and the speed of changing display all are improved. The multichannel PC tachistoscope with this technique is especially suitable for research requiring high-quality images and rapid successive presentation of stimuli.

Computer Storage Devices↗

Comparing visual perception on conventional cabinet tachistoscopes and computer monitor tachistoscopes.

Computer monitor-based tachistoscopes (using a cathode ray tube, CRT) and conventional tachistoscopes differ in experimental control over stimulus continuity, duration, and timing accuracy. This study evaluated the perception of visual stimuli presented with the two different types of devices. An experiment was conducted to compare recognition of visuospatial stimuli (random shapes) presented laterally and centrally in the visual fields for short exposure durations (14, 29, and 43 msec), first with one device and then with another. Results indicated that the subjects' error rates and laterality patterns were similar on both types of tachistoscopes. It was concluded that perception of visual stimuli presented as continuous images on a conventional tachistoscope may be equivalent to perception of visual stimuli presented as pulsating images on a CRT. Further studies are needed using other types of visual materials to determine the range of visual stimuli for which both types of tachistoscopes measure equivalent perceptual processes.

Adolescent↗

Motion aftereffect transfer in the monofixation syndrome.

If one adapts to a moving repetitive stimulus of stripes that is suddenly stopped, the stripes will appear to move backward. This apparent backward motion is the motion aftereffect (MAE), and its duration is a measure of its magnitude. If one eye adapts to the moving stimulus and the other eye experiences the aftereffect to the stationary stimulus, the aftereffect has been transferred from one eye to the other and is termed the interocular transfer of the MAE. Experimental evidence indicates that the degree of MAE transfer correlates with clinical binocularity. This study compares the MAE transfer in six subjects with the monofixation syndrome to five normal subjects. The stimuli used are sinusoidal stripes generated on two cathode-ray tubes, subtending either 8 degrees or 2 degrees of visual angle with a periodicity of either 0.5 or 3 cycles/degree presented haploscopically. Subjects with the monofixation syndrome differed significantly from normal subjects in the amount of MAE transferred, implying a lack of central neuronal connections in addition to those mediating conscious central fusion in clinical sensory testing.

Adaptation, Physiological↗

Measurements of extremely low-frequency magnetic fields around video display terminals.

The extremely low-frequency (ELF) magnetic field emissions of seven video display terminal (VDT) models were measured. A measuring coil with a linearized frequency response (50 Hz to 25 kHz) was used. The dominating ELF magnetic field around the terminals was the 50 or 60 Hz asymmetric triangular waveform from the vertical deflection coil of the cathode ray tube. At the distance of 50 cm, the magnetic field strength was still slightly higher than the background level in usual office rooms, but several orders of magnitude lower than the thresholds of known interaction mechanisms. Some recent experiments suggest that certain biological effects may occur at field strengths only a few times higher than those found at the position of VDT operators, but the significance of these effects to human health is not known.

Computer Systems↗