Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bronchoscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Bronchoscopic removal of foreign bodies from children in Bosnia and Herzegovina: experience with 230 patients.

OBJECTIVES: To present the experience from an emerging country, in the bronchoscopic removal of foreign bodies in children. METHODS: Retrospective analysis of medical records from 230 patients treated at the ENT Department, Tuzla University Hospital, Bosnia and Herzegovina, between January 1987 and December 1998. RESULTS: Positive bronchoscopic findings were present in 136 (59.1%) cases. Right bronchus (53.7%) and left bronchus (30.1%) were the most frequent location of extracted foreign bodies. The types of extracted foreign bodies were organic in 114 (83.8%), non-organic in 12 (8.8%) and of an indefinite nature in ten (7.4%) cases. The most frequent type of foreign body was: pumpkin seed (23.4%), peanut (18.4%), bean (14.6%). The nature of the foreign body could not be determined in 7.4% cases: either because the foreign bodies were in the state of disintegration or were too small. Two children (0.87%) died during the bronchoscopy. CONCLUSION: Aspiration of foreign body into tracheobronchial tree in children carries a high risk although prompt treatment of survivors is associated with low mortality. Health care education is the key to prevention.

Age Distribution↗

Laryngeal mask airway for therapeutic fiberoptic bronchoscopic procedures.

These cases illustrate the advantages of the laryngeal mask as compared with an endotracheal tube or oxygen face mask for selected patients undergoing therapeutic bronchoscopic procedures. The advantages include a larger internal diameter allowing easier passage of instruments, reduced work of breathing, lack of discomfort associated with insertion, access to the vocal cords and upper trachea unimpeded by the presence of an endotracheal tube, and capnographic and volume monitoring of respiration. The LMA is thus a valuable alternative for airway management in pulmonary compromised patients undergoing therapeutic bronchoscopic procedures.

Adult↗

Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images.

This paper describes a method for tracking the camera motion of a flexible endoscope, in particular a bronchoscope, using epipolar geometry analysis and intensity-based image registration. The method proposed here does not use a positional sensor attached to the endoscope. Instead, it tracks camera motion using real endoscopic (RE) video images obtained at the time of the procedure and X-ray CT images acquired before the endoscopic examination. A virtual endoscope system (VES) is used for generating virtual endoscopic (VE) images. The basic idea of this tracking method is to find the viewpoint and view direction of the VES that maximizes a similarity measure between the VE and RE images. To assist the parameter search process, camera motion is also computed directly from epipolar geometry analysis of the RE video images. The complete method consists of two steps: (a) rough estimation using epipolar geometry analysis and (b) precise estimation using intensity-based image registration. In the rough registration process, the method computes camera motion from optical flow patterns between two consecutive RE video image frames using epipolar geometry analysis. In the image registration stage, we search for the VES viewing parameters that generate the VE image that is most similar to the current RE image. The correlation coefficient and the mean square intensity difference are used for measuring image similarity. The result obtained in the rough estimation process is used for restricting the parameter search area. We applied the method to bronchoscopic video image data from three patients who had chest CT images. The method successfully tracked camera motion for about 600 consecutive frames in the best case. Visual inspection suggests that the tracking is sufficiently accurate for clinical use. Tracking results obtained by performing the method without the epipolar geometry analysis step were substantially worse. Although the method required about 20 s to process one frame, the results demonstrate the potential of image-based tracking for use in an endoscope navigation system.

Algorithms↗

The role of the fibreoptic bronchoscope in otorhinolaryngological practice.

Flexible fibreoptic bronchoscope has been employed in the examination of the nasopharynx, pharynx, larynx, trachea, bronchus and intrathoracic oesophagus under local anaesthesia. It is used either for diagnostic or therapeutic purposes. A total of 1690 procedures have been performed with no complication. The indications and findings in these procedures are listed. The advantages and limitations of the use of flexible fibreoptic bronchoscope as a 'panendoscopic examination' instrument are discussed.

Adolescent↗

Bronchoscopic removal of foreign bodies in adults: experience with 62 patients from 1974-1998.

The authors reviewed their experience with therapeutic bronchoscopy for removal of tracheobronchial foreign bodies in the adult. Bronchoscopy records and collection of foreign bodies in the endoscopic department were retrospectively examined. Among 37,466 bronchoscopies performed between 1974-1998, 62 (0.2%) were performed for the removal of tracheobronchial foreign bodies. Medical history was suggestive of foreign body aspiration in 33 patients and the chest radiograph was suggestive in 10 patients. The procedure was performed with the flexible bronchoscope in 42 patients (68%), rigid bronchoscope in 4 (6%), and with both in 16 (26%) patients. Foreign bodies were found in the right bronchial tree on 42 occasions, in the left on 20 and in the trachea once. In 39 patients, inflammatory granulations were found around the foreign body. The origins of the foreign bodies included: bone fragments (n=31), vegetable (n=10), broncholith (n=8), a part of dental prosthesis (n=7), endodontic needle (n=2), a metallic (n=2), or plastic (n=1) particle, a tracheostomy tube (n=1) and a match (n=1). In one patient, 2 foreign bodies were found. The foreign bodies were successfully removed in all but 2 patients (3%). The most useful instruments for removal were alligator forceps and the wire basket. Foreign bodies in the tracheobronchial system are rare in adults. They can be successfully removed in the majority of patients under either flexible or rigid bronchoscopy.

Adolescent↗

Diagnostic yield of bronchoscopic sampling methods in bronchial carcinoma.

OBJECTIVES: The aim was to study the yield of malignant or suspicious cells from bronchoalveolar lavage (BAL), endobronchial biopsy (BX) and endobronchial brushing (BR) specimens obtained at bronchoscopy. METHODOLOGY: We prospectively followed up all patients who had undergone bronchoscopy and studied those with subsequent diagnosis of bronchial carcinoma at a tertiary referral centre. Bronchoalveolar lavage, BX and BR were performed, sequentially whenever possible, by one pulmonologist. The parameters assessed were age, gender, macroscopic bronchoscopic findings, TNM staging, radiological findings, histological typing, and diagnostic yield from BAL, BX, and BR. RESULTS: One hundred patients (31 females, 69 males; mean age +/- SD, 61.8+/-12.7 years; range 32-81 years) were studied between 1995 and 1997. Of these, BAL, BX and BR were performed on 100, 64 and 37 cases which yielded diagnostic specimens for bronchial carcinoma in 69, 78.1, and 62.2% of cases, respectively (P > 0.05). Diagnostic specimens were therefore obtained in 69,50, and 23% of the entire patient cohort from BAL, BX, and BR, respectively (P < 0.001). The diagnostic yield of BAL was independent of patient age, gender, site of lesion, TNM staging, histological typing and macroscopic bronchoscopic findings. Addition of BX, BR and postbronchoscopic sputum sampling to BAL only increased the yield of diagnostic specimens for bronchial carcinoma by 7, 0, and 4%, respectively. CONCLUSION: Bronchoalveolar lavage is a highly effective sampling method to obtain cytological evidence for bronchial carcinoma. The diagnostic yield for BAL is independent of tumour or other clinical characteristics. Further studies should be performed to confirm these important and clinically relevant findings.

Adult↗

Bronchoscopic removal of foreign bodies in children: retrospective analysis of 822 cases.

At the Department of Thoracic and Cardiovascular Surgery of Hacettepe University, a total number of 822 pediatric bronchoscopies were performed from 1984 through 1990 for suspected foreign body aspiration. Of the children 65.3% were boys and 34.7% were girls ranging in age from one month to 14 years. Definitive statement of foreign-body aspiration was obtained from 394 patients. Unilateral hyperaeration, atelectasis, and unilateral parenchymal infiltration were the most common radiological findings. In all endoscopic procedures, a pediatric rigid bronchoscope was used under general anesthesia and controlled ventilation. Foreign bodies were found in 77.7% of the 822 patients. In the rest of the children inflammatory disorders were confirmed. The foreign bodies most commonly found in 639 patients were sun-flower seeds (21.1%), beans (10.4%), water-melon seeds (10%), and hazelnuts (9.8%). In our presented series, the incidence of non-fatal complication was 1.8%, apart from these patients 5 of them (0.6%) died after the bronchoscopic procedures.

Adolescent↗

Bronchoscopic lavage with perfluorocarbon decreases postprocedure hypoxemia in an ovine model of smoke inhalation.

OBJECTIVE: Bronchoscopy and lavage are used to confirm diagnosis and can be therapeutic in patients suffering inhalation injury. Lavage is traditionally performed using saline, which is unfortunately associated with profound transient hypoxemia. Perfluorocarbons, having a high gas solubility for oxygen and carbon dioxide, increase oxygenation when instilled into the airway. We hypothesized that the use of perfluorocarbons for bronchoscopic lavage would attenuate this transient hypoxemia. METHODS: Sheep were prepared for chronic study. They were insufflated with cotton smoke and then randomized to receive a lavage with 200 mL of perfluorocarbon or saline at 2, 6, 12, and 24 hours after injury. RESULTS: All animals had a steady and significant decline in their pre- to post-PaO2/FiO2 (P/F) ratio. At 2, 6, and 12 hours, the saline lavage group had a significant decrease in their P/F ratio (485+/-32 to 212+/-37 mm Hg, 439+/-22 to 170+/-40 mm Hg, and 381+/-48 to 184+/-59 mm Hg). This decrease in P/F ratio was not observed in the perfluorocarbon group (474+/-19 to 459+/-29 mm Hg, 424+/-32 to 387+/-43 mm Hg, and 366+/-50 to 357+/-67 mm Hg). CONCLUSION: These findings indicate that perfluorocarbons attenuate the transient hypoxemia associated with saline bronchoscopic lavage and thus may be considered safer for patients with acute lung injury.

Animals↗

Registration of real and CT-derived virtual bronchoscopic images to assist transbronchial biopsy.

This paper describes research work motivated by an innovative medical application: computer-assisted transbronchial biopsy. This project involves the registration, with no external localization device, of a preoperative three-dimensional (3-D) computed tomography (CT) scan of the thoracic cavity (showing a tumor that requires a needle biopsy), and an intraoperative endoscopic two-dimensional (2-D) image sequence, in order to provide assistance in transbronchial puncture of the tumor. Because of the specific difficulties resulting from the data being processed, a multilevel strategy was introduced. For each analysis level, the relevant information to process and the corresponding algorithms were defined. This multilevel strategy, thus, provides the best possible accuracy. Original image processing methods were elaborated, dealing with segmentation, registration and 3-D reconstruction of the bronchoscopic images. In particular, these methods involve adapted mathematical morphology tools, a "daemon-based" registration algorithm, and a model-based shape-from-shading algorithm. This pilot study presents the application of these algorithms to recorded bronchoscopic video sequences for five patients. The preliminary results presented here demonstrate that it is possible to precisely localize the endoscopic camera within the CT data coordinate system. The computer can thus synthesize in near real-time the CT-derived virtual view that corresponds to the actual endoscopic view.

Biopsy, Needle↗

In vitro study of the safety limits of bronchoscopic argon plasma coagulation in the presence of airway stents.

OBJECTIVE AND BACKGROUND: The purpose of this study was to identify the safety limits of bronchoscopic argon plasma coagulation (APC) around indwelling airway stents. METHODOLOGY: This is an experimental in vitro study simulating a patient-care environment. Uncovered and covered Nitinol (Ultraflex), uncovered and covered Wallstent and studded silicone stents were deployed in the tracheobronchial tree of a ventilated and oxygenated heart-lung block from an expired pig. APC was performed at power settings of 40 and 80 W using F(I)O(2) of 0.21, 0.40 and 1.00 and an argon gas-flow rate of 0.8 L/min through a flexible fiberoptic bronchoscope. The primary outcome was the time taken for the APC to cause stent damage. Stent damage was defined as discoloration, ignition or rupture. RESULTS: Airway fires involving all five stents consistently occurred in the presence of 100% oxygen at powers of 40 W and 80 W. At lower F(I)O(2) (0.21 and 0.40) silicone stents were not damaged at 40 W and 80 W. Uncovered Ultraflex stents were undamaged using 40 W at either F(I)O(2) (0.21 and 0.40), but could be damaged using both F(I)O(2) levels when the power was increased to 80 W. Covered Ultraflex and both uncovered and covered Wallstents were damaged at both power settings (40 W and 80 W) and F(I)O(2) (0.21 and 0.40) levels, with a trend towards earlier damage using higher F(I)O(2) and power. CONCLUSION: Working within the parameters identified in this study (power 40 W, F(I)O(2) 0.21, APC flow-rate 0.8 L/min), APC is a safe method for tissue devitalization and destruction and avoids the risk of airway stent ignition, especially if short bursts of APC are employed. The safety limits identified using an F(i)O(2) of 0.4, however, are also important because some patients undergoing resection may require oxygen therapy.

Animals↗

133Xenon ventilation scintigraphy applied to bronchoscopic lung volume reduction techniques for emphysema: relevance of interlobar collaterals.

BACKGROUND: 133Xenon ventilation scintigraphy and (99m)Tc-MAA perfusion scintigraphy can be used to assess dynamic ventilation patterns in patients with severe emphysema. AIM: To describe the scintigraphic features of attempted bronchoscopic lung volume reduction (BLVR), exploring mechanisms that might explain the unexpected lack of postoperative atelectasis. METHODS: Five patients with heterogenous severe upper lobe emphysema were evaluated with 133Xenon ventilation and (99m)Tc-MAA perfusion scintigraphy, chest radiography, bronchoscopy and high resolution computed tomography before and up to 1 month after endoscopic placement of bronchial prostheses (BLVR). Ex vivo assessment of the lungs of two further patients with severe upper lobe emphysema was performed. RESULTS: No significant subsegmental or lobar collapse was evident on post-procedure chest radiography or high resolution computed tomography, despite bronchoscopic confirmation of adequate position and functioning of prostheses. 133Xenon ventilation scintigraphy confirms significantly decreased upper lobe wash-in (P < 0.023), unchanged lower lobe wash-in and significantly increased lower lobe wash-out rates (P < 0.005) after BLVR. Significant redistribution of perfusion to the lower lobes occurred after BLVR (P < 0.025). Ex vivo experiments on explanted emphysematous lungs demonstrated that these findings could best be explained by collateral interlobar ventilation, which was calculated in one specimen to be as high as 15% of total lower lobe ventilation. Peri-valvular leak is a much less likely possibility. CONCLUSION: 133Xenon ventilation scintigraphy indicated the presence of significant interlobar collateral ventilation in patients with severe emphysema that may have major relevance to these novel alternative techniques to lung volume reduction surgery. 133Xenon scintigraphy can be used in the evaluation of severe emphysema before and after novel therapeutic interventions.

Bronchoscopy↗

Pulmonary infiltrates in patients with haematologic malignancies: clinical usefulness of non-invasive bronchoscopic procedures.

In a prospective study 90 patients with haematologic malignancies (57 acute leukaemias, 6 Hodgkin's Diseases, 15 Non-Hodgkin Lymphomas, 12 other diseases), with fever exceeding 38.4 degrees C and newly developed pulmonary infiltrates underwent bronchoscopy obtaining bronchoalveolar lavage, bronchial washings and protected brush specimen (n = 71). Pneumonias due to gram-negative bacteria (n = 38) and fungi (n = 34) were most frequent. Bronchoscopic specimens yielded 226 isolates (2 different organisms/bronchoscopy on average). 112 organisms were finally regarded as causing pneumonia. Sensitivity of bronchoscopy in diagnosing infectious episodes was 66%, but only 4 out of 13 non-infectious pulmonary infiltrates could be identified. Bronchoscopy was most effective in the diagnosis of pneumocystis carinii and herpes virus pneumonia, whereas sensitivity and specificity of detecting fungal and bacterial pneumonia were low. Empirical antimicrobial therapy was verified by evaluation of bronchoscopic samples in 25 out of 90 cases. Empirical therapy was successfully changed according to the results of invasive samplings in 34 out of 90 cases. Early identification of causative pathogens had a significant impact on survival.

Adolescent↗

Use of the flexible fibreoptic bronchoscope in diagnosis of sputum-negative pulmonary tuberculosis.

In four years' use of the flexible fibreoptic bronchoscope in diagnosing sputum-negative pulmonary tuberculosis, of 275 patients with tuberculosis suspected from chest radiographic appearances, 89 (32.4%) were shown to have active disease. In 60 (67.4%) of these patients the diagnosis was made from samples obtained through the fibreoptic bronchoscope (56 from bronchial brushings, four from transbronchial biopsy samples). Of the 56 positive bronchial brushings, 35 were positive on direct smear and 21 only on culture. Transbronchial biopsy exclusively accounted for only four of the 60 positive diagnoses. In the remaining 29 patients, the diagnosis was made from further sputum or biopsy specimens in 15, from the response to treatment in 12, and at necropsy in two. In six of 10 patients with military tuberculosis, bronchial brushings were positive on direct smear.

Biopsy↗

Granular cell tumour of the bronchus: bronchoscopic and clinical features.

Granular cell tumours are uncommon, generally benign neoplasms of uncertain origin that occasionally affect the tracheobronchial tree. Their incidence seems to be increasing, despite the fact that such tumours are rarely suspected on clinical grounds or bronchoscopic appearance. Here we describe three cases of endobronchial granular cell tumours, one of which regressed spontaneously after biopsy, and review previous accounts of their bronchoscopic and clinical features.

Bronchoscopy↗

Bronchoscopic and angiographic findings in tracheobronchial endometriosis.

The case is described of a 31 year old woman who presented with complaints of recurrent haemoptysis coinciding with menstruation. Bronchoscopic examination revealed multiple purplish-red submucosal lesions on the right side of the trachea and bilateral bronchial trees which appeared during her menses and regressed in the intermenstrual periods. Brush cytology revealed cell clusters consistent with endometrial origin. Bronchial angiography demonstrated prominent vasculature at the right paratracheal area and bilateral bronchial trees corresponding to the lesions seen on bronchoscopic examination. Her haemoptysis was satisfactorily controlled by danazol therapy and follow up bronchoscopy showed disappearance of the tracheobronchial lesions. To our knowledge this is the first case of thoracic endometriosis with tracheal involvement.

Adult↗

Hilar masses: evaluation with CT-guided biopsy after negative bronchoscopic examination.

Computed tomography (CT)-guided biopsies of 20 patients with hilar masses were performed after non-diagnostic bronchoscopic examination. Bronchoscopy included washings, brushings, routine biopsy, and, in many cases, transbronchial biopsy. In all but one case (95%), biopsy with a 22-gauge needle permitted a cytologic diagnosis of malignancy. In 14 of the 19 cases (74%), a diagnosis of primary lung carcinoma involving the hili was made, and in the remaining five of the 19 (26%), metastatic hilar adenopathy from an extrathoracic primary tumor was identified. A pneumothorax rate consistent with our average rate for CT-guided biopsies (25%) was obtained, and only one patient required chest tube placement. In this series, CT-guided biopsies of hilar masses were more consistently successful in obtaining tissue for diagnosis than were bronchoscopic biopsies. Transthoracic needle aspiration biopsy may be the preferred initial diagnostic procedure in many patients with hilar masses.

Adult↗

AIDS-related Kaposi sarcoma of the lung: radiographic findings and staging system with bronchoscopic correlation.

PURPOSE: To determine the chest radiographic findings in patients with tracheobronchial Kaposi sarcoma (KS) and to develop a radiographic staging system that allows comparison of radiographic to bronchoscopic findings and allows assessment of the typical temporal progression of pulmonary KS. MATERIALS AND METHODS: The chest radiographs and medical records of 76 male patients, aged 23-60 years (mean, 36 years 4 months) with bronchoscopically proved KS were retrospectively reviewed. Tumor extent at bronchoscopy (grade 1-3) was compared with severity of parenchymal disease (radiographic stage 0-3). RESULTS: There was a statistically significant relationship between extent of tracheobronchial disease and radiographic stage (P = .01). However, in some patients, parenchymal KS of advanced stage was present with no visible endobronchial disease. CONCLUSION: The proposed staging system describes features of early, moderate, and advanced KS. Although there is a correlation between tracheobronchial and parenchymal disease, the latter can occur in the absence of endobronchial lesions.

Acquired Immunodeficiency Syndrome↗