Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BIOPSIES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16Linked to original sources

Significance of atypical and suspicious small acinar proliferations, and high grade prostatic intraepithelial neoplasia on prostate biopsy: implications for cancer detection and biopsy strategy.

PURPOSE: We reviewed our results from a urological pathology reference laboratory with respect to the incidence of HGPIN, and atypical and suspicious lesions in the spectrum of ASAP. Subsequent CaP findings on repeat biopsy with relevant clinical implications were assessed. MATERIALS AND METHODS: A review of 42,667 prostate biopsies was performed. We defined atypical and suspicious as variants of ASAP with suspicious being more worrisome for CaP. Findings were correlated with the location of CaP on repeat prostate biopsy. RESULTS: The rate of subsequent CaP detection was significantly higher for an initial diagnosis of suspicious findings (51% or 54 of 107 cases) than for atypical findings (34% or 39 of 116) or HGPIN (22% or 79 of 358, p < 0.001). CaP was found on the same side of the prostate in 61 of 78 (78%), 30 of 39 (77%) and 41 of 54 patients (76%) with initial HGPIN, atypical and suspicious biopsies, respectively. There was no significant difference among the 3 groups in the likelihood of future CaP at the same site or the same side of the prostate. CONCLUSIONS: Patients with a suspicious biopsy were significantly more likely to have CaP on future biopsy than those with atypical findings or HGPIN, suggesting that there may be divisions with prognostic significance in the larger category of ASAP. To our knowledge the reproducibility of recognizing such divisions remains to be established. Neither atypical nor suspicious lesions were more likely than HGPIN to predict CaP at the same site or side of the prostate as the original diagnosis. Repeat biopsy may be indicated in any patient with HGPIN, or atypical or suspicious lesions and this biopsy should not be limited to the site or side of the original pathological findings.

Aged↗

Systematic transrectal ultrasound guided prostate biopsy after negative digitally directed prostate biopsy.

The diagnostic accuracy of digitally directed prostate biopsies was evaluated by performing systematic ultrasound guided biopsies on 44 patients who had previously had a negative prostate biopsy by systematic digitally directed technique. All 44 patients still had palpable abnormalities. Core biopsies (2 to 4) were obtained from each lateral lobe of the prostate with 2 additional cores directed at hypoechoic lesions. Only 4 of the 44 ultrasound directed biopsies (9.1%) were positive for cancer. These results confirm the postulate that random systematic digitally directed biopsy is highly accurate in making the diagnosis of prostate cancer. They also suggest that performing biopsies in a systematic pattern is more important than the method used to guide the biopsy needle.

Biopsy↗

Using the percentage of biopsy cores positive for cancer, pretreatment PSA, and highest biopsy Gleason sum to predict pathologic stage after radical prostatectomy: the Center for Prostate Disease Research nomograms.

OBJECTIVES: To develop probability nomograms to predict pathologic outcome at the time of radical prostatectomy (RP) on the basis of established prognostic factors and prostate biopsy quantitative histology. METHODS: Using information from the database of the Center for Prostate Disease Research (CPDR), univariate and multivariate analyses were performed on 1510 men who had undergone transrectal ultrasound and biopsy for diagnosis and had radical prostatectomy as primary therapy, with variables of age, race, clinical stage, pretreatment prostate-specific antigen (PSA), biopsy Gleason sum, and percentage of biopsy cores positive for cancer (total number of cores positive for cancer divided by the total number of cores obtained). The percentages of biopsy cores positive were grouped as less than 30%, 30% to 59%, and greater than or equal to 60%. The three most significant variables were used to develop probability nomograms for pathologic stage. RESULTS: PSA, biopsy Gleason sum, and percentage of cores positive were the three most significant independent predictors of pathologic stage. The assigned percentage of biopsy core-positive subgroups along with pretreatment PSA and highest Gleason sum were used to develop probability nomograms for pathologic stage. CONCLUSIONS: Pretreatment PSA, highest biopsy Gleason sum, and the percentage of cores positive for cancer are the most significant predictors for pathologic stage after radical prostatectomy. On the basis of these findings, CPDR probability nomograms were developed to predict pathologic outcome at the time of RP.

Adult↗

The correlation between the grade of dyskaryosis on cervical smear, grade of cervical intraepithelial neoplasia (CIN) on punch biopsy and the final histological diagnosis on cone biopsies of the cervix.

This study was carried out to assess how reliably a punch biopsy of the cervix predicts the maximum grade of CIN present and whether a colposcopically directed punch biopsy is more reliable than cytology in predicting the grade of intraepithelial neoplasia present in the cervix. The grade of CIN in 107 cone biopsy specimens was compared with the grade of CIN and dyskaryosis in punch biopsies and smears from the same patients. Exact correlations were identified between the highest grade lesions on cone biopsy and those in 63% of punch biopsies and 49% of cervical smears. We conclude that punch biopsy provides a more reliable estimate of the highest grade of CIN present in a subsequent cone biopsy than cervical cytology, but nonetheless fails to give a consistent estimate of the final grade of CIN in a significant percentage of cases.

Biopsy↗

Topics in bone marrow biopsy pathology: role of marrow topography in myelodysplastic syndromes and evaluation of post-treatment and post-bone marrow transplant biopsies.

The role of bone marrow biopsy is expanding. Bone marrow biopsy is considered a "gold standard" for assessing cellularity and infiltrative process. More recently, biopsies are increasingly used for immunohistochemical stains and molecular studies such as in situ hybridization and laser microdissection, further augmenting morphologic interpretation. Biopsies are playing a greater role in early diagnosis of myelodysplastic syndromes (MDS). Both primary and secondary MDS are increasing (5% to 12%), and can present a significant challenge in early diagnosis. Present MDS diagnostic criteria are based purely on marrow aspirate smears, peripheral blood smears, and ancillary studies, and may not be adequate in some instances. With the current understanding of marrow topography and hematopoietic microenvironment, bone marrow biopsies are greatly useful in early diagnosis and grading of MDS. Marrow biopsies also are helpful in evaluation of postchemotherapy and post-bone marrow transplant patients. Assessment of topographic alteration and certain corroborating immunohistochemical and molecular studies can only be performed on bone marrow biopsies, and these ancillary studies will contribute significantly to the understanding of hematopoietic disorders. Bone marrow biopsy, in conjunction with other modalities such as flow cytometry, will play a significant role in diagnostic hematopathology. Ann Diagn Pathol 5:110-120, 2001.

Biopsy↗

Biopsy-negative giant cell arteritis: clinical spectrum and predictive factors for positive temporal artery biopsy.

OBJECTIVES: To examine the frequency and features of patients with biopsy-negative giant cell arteritis (GCA), establish differences with biopsy-proven GCA, and identify the optimal set of predictors for a positive temporal artery biopsy (TAB) in patients with GCA. METHODS: Retrospective study of an unselected population of patients with GCA diagnosed at the reference hospital for a defined population between 1981 and 1998. Patients were classified into biopsy-proven GCA if a TAB was positive for GCA, or biopsy-negative GCA if they fulfilled the American College of Rheumatology 1990 criteria for the classification of GCA (Hunder GG, et al Arthritis Rheum 1990; 33:1122-8) despite having a negative TAB. RESULTS: One hundred ninety Caucasian patients were diagnosed with GCA. Twenty-nine of them (15.3%) had a negative TAB. In these biopsy-negative patients, headache and polymyalgia rheumatica were frequent presenting symptoms. In contrast, jaw claudication, abnormal temporal artery on physical examination, and constitutional syndrome (asthenia, anorexia, and weight loss of 4 kg or more) were less common. They also had lower biologic markers of inflammation. The best predictive model of biopsy-proven GCA included a history of constitutional syndrome (OR = 6.1), an abnormal temporal artery on physical examination (OR = 3.2), and the presence of visual complications (OR = 4.9). CONCLUSIONS: In GCA, a subset of patients have a high likelihood of having a negative TAB. This subset seems to have less severe ischemic complications than that of biopsy-proven GCA. In patients without visual manifestations, abnormal temporal artery on examination or constitutional syndrome the risk of having an abnormal TAB is low.

Aged↗

[Vacuum punch biopsy under digital stereotaxic control, a new procedure in percutaneous diagnostic incision and excision biopsy of mammographic findings: initial experience].

PURPOSE: To evaluate a digital, stereotactically controlled vacuum punch biopsy method. MATERIAL AND METHOD: In 60/61 female patients a vacuum punch biopsy (14 G) was performed under digital stereotactic control; by means of a single biopsy 1-2 cm3 of tissue was obtained. In one patient the examination could not be carried out because of insufficient microcalcification. Excision biopsies were performed because of doubtful microcalcification (24), focal lesions (35) or abnormal tissue architecture (1). RESULTS: 48 of the biopsies proved benign, 2 showed dysplasias, 5 in situ and 5 invasive carcinomas. In all cases the histological and radiological diagnoses were in agreement. The possibility of a non-presentative biopsy could be excluded with a high degree of certainty because of the accurate localisation and the coherent tissue samples; this produced significant increase in diagnostic certainty. Subsequent haematomas seen mammographically (58/60) are smaller (1-1.5 cm) than for conventional percutaneous punch biopsies because of the effect of suction. The examination was well tolerated (there were no significant haematomas and no infection). Problems consisted of one case of bleeding (due to little experience) and one incorrect localisation which was immediately recognised. DISCUSSION: If the high degree of accuracy, which is expected, can be confirmed, the procedure would appear suitable for replacing diagnostic operative biopsies of non-characteristic mammographic finding.

Biopsy↗

Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.

PURPOSE: To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. MATERIAL AND METHODS: A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. RESULTS: There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. CONCLUSION: Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.

Adolescent↗

Endomyocardial biopsy in the cardiac allograft recipient. A review of 570 biopsies.

The morphologic abnormalities present in 570 endomyocardial biopsies from 39 cardiac allograft recipients and 16 autopsy hearts are described, and criteria pertinent to the diagnosis of rejection discussed. Entirely normal myocardium was apparent in 16% of the biopsies. Abnormalities related to biopsy of previous biopsy site occurred in 69%, and mononuclear infiltrates of varying intensity were present in 64% of the biopsies. Acute rejection was diagnosed in 17 (43.6%) patients in 32 (5.6%) of the biopsies and five hearts at autopsy. Seven of the biopsies with acute rejection were follow-up biopsies after a previous diagnosis of acute rejection and represented ongoing acute rejection. Similarly, three patients with rejection at autopsy died with ongoing rejection. The overall frequency of acute rejection was thus 0.70 episodes per patient. The most reliable histologic feature in the diagnosis of acute rejection in cyclosporine immunosuppressed recipients was a diffuse mononuclear infiltrate, apparent at low magnification. Myocyte necrosis, said to be critical in the diagnosis of rejection in cyclosporine-treated patients, was not a reliable indicator in the authors' experience.

Adolescent↗

Percutaneous liver biopsy in children: impact of ultrasonography and spring-loaded biopsy needles.

BACKGROUND: Percutaneous liver biopsy is a valued tool of pediatric hepatology. Recent advances in technology have incorporated spring-loaded biopsy needles and ultrasonography in percutaneous liver biopsy. METHODS: To determine the frequency of complications after liver biopsy and whether variables such as needle selections (Jamshidi, Monopty, or ASAP) and ultrasound guidance could predict complications, medical records were retrospectively reviewed of all patients who underwent percutaneous liver biopsy during a 7-year period. Available data were collected from 123 patients who had undergone a total of 249 percutaneous liver biopsies. All patients with evidence of mild clotting abnormalities (8.83%) received platelets, cryoprecipitate, or fresh-frozen plasma. RESULTS: There was a 6.83% incidence of overall complications, and a 2.4% incidence of major complications. The mortality rate was 0.4%. Ultrasound localization did not diminish the risk of bleeding during biopsy. There was no significant difference in the change of hematocrit between the aspiration (Jamshidi) and spring-loaded (Monopty) needles. However, in patients less than 5 years of age, the change of hematocrit was significantly higher (P < 0.05) with the 15- or 18-gauge ASAP needle (Microvasive, Quincy, MA, U.S.A.) than with either the Jamshidi (Allegience Healthcare, Columbia, MD, U.S.A.) or Monopty (Bard Technologies, Covington, GA, U.S.A.) needles. CONCLUSION: Percutaneous liver biopsy is safe, using either aspiration or spring-loaded needles. Ultrasound guidance may not be helpful except in patients who underwent segmental liver transplantation.

Adolescent↗

Significance of routine transition zone biopsies in Japanese men undergoing transrectal ultrasound-guided prostate biopsies.

BACKGROUND: The objective of this study was to evaluate the clinical significance of additional routine transition zone (TZ) biopsies in Japanese men undergoing transrectal ultrasound (TRUS)-guided systematic 8-core peripheral zone (PZ) biopsies. METHODS: Between October 2002 and December 2004, a total of 788 consecutive patients underwent TRUS-guided systematic biopsy of the prostate for the fi rst time. As a rule, 10 cores were taken from each patient; that is, 8 cores from the PZ, including the standard sextant cores and 2 cores from the anterior lateral horns, and 2 additional cores from the bilateral TZ. The cancer detection rate was calculated according to several parameters. We also assessed the disease extent on radical prostatectomy specimens according to the cancer location within the biopsy specimens. RESULTS: Prostate cancer was detected by 10-core biopsies in 209 (26.5%) of the 788 patients, and 11 of these patients had positive cores only in the TZ; that is, the increase in cancer detection rate by sampling two additional cores from the TZ was 5.3%. Among 209 patients diagnosed as having prostate cancer, radical prostatectomy without any neoadjuvant therapy was performed in 59 patients with positive biopsy cores in the PZ, 7 in the TZ and 32 in both the PZ and TZ. Patients with positive cores in both zones showed significantly less favorable characteristics, indicating more advanced disease than that in those with positive cores in either zone. CONCLUSIONS: Routine TZ biopsy did not significantly increase the detection rate of prostate cancer; however, the anatomical location of positive biopsy cores could provide additional information concerning disease extension in patients undergoing radical prostatectomy.

Aged↗

Histological changes in prostate biopsies after salvage cryotherapy: effect of chronology and the method of biopsy.

OBJECTIVES: To examine changes in prostate biopsies at different intervals after salvage cryotherapy and the effect of biopsy type (transrectal ultrasonography-guided vs transurethral resection, TUR), as the sequence and extent of histological changes occurring in the prostate after salvage cryotherapy for local failure of prostate cancer treatment are unknown. PATIENTS AND METHODS: In all, 158 prostate biopsies from 150 patients were examined histologically after salvage cryotherapy for prostate cancer after radiotherapy had failed. Specimens were grouped by time from cryotherapy and biopsy technique. RESULTS: Biopsies showed hyalinization, necrosis, inflammation and residual cancer. Hyalinization became predominant over time, most notably in biopsies with no residual cancer. Core biopsies showed more hyalinization and regenerating glands, while TUR biopsies showed more necrosis and inflammation. CONCLUSIONS: Tissue cryo-injury and reactive changes last for >1 year; more extensive cryo-injury suggests more effective cancer ablation. A long-term follow-up is necessary, as prostate cancer might remain indolent for >1 year.

Analysis of Variance↗

Liver biopsies from psoriatics related to methotrexate therapy. 3. Findings in post-methotrexate liver biopsies from 160 psoriatics.

The purpose of this paper is to report findings in post-MTX liver biopsies from 160 psoriatics treated with Methotrexate (MTX) in single biopsy and B. 68 patients with serial biopsies. At the time of liver biopsy the 92 patients had received a mehosis and six patients had fibrosis. Comparing these 7 patients with patients having normal liver histology (13 patients) revealed no statistically significant difference in cumulative doses of MTX, but a statistically significant higher admitted alcohol intake during MTX therapy (p less than 0.002) and an older age (p less than 0.01) in the patients with cirrhosis or fibrosis. in the 68 patients MTX had accumulated to a mean dose of 3940 mg (range 32k-8355 mg) at the time the latest liver biopsies were taken. Among the latest liver biopsies were 14 cirrhosis (21 per cent, 95 per cent confidence limits: 12-32 per cent) and 16 fibrosis (24 per cent, 95 per cent confidence limits: 14-35 per cent). The 14 patients with cirrhosis when compared to patients with normal histology (9 patients), had taken an equal total dose of MTX at the latest liver biopsy, but had consumed a statistically significant higher amount of alcohol (p less than 0.05) during MTX therapy and also tended to be older (p less than 0.006). Comparison of a material A and B indicates that the prevalence of cirrhosis and fibrosis among MTX treated psoriatics increases rapidly beyond a cumultative dose of two to four grams of MTX. No MTX treated psoriatics should thus be allowed to pass this dosage range without having a liver biopsy performed.

Adult↗

Small bowel biopsy for malabsorption: comparison of the diagnostic adequacy of endoscopic forceps and capsule biopsy specimens.

Biopsy specimens of the small bowel were obtained from 40 patients suspected of having malabsorption. Four different techniques were used at a single session--namely, endoscopic biopsy of the descending duodenum using paediatric and standard size forceps and suction capsule biopsy of the descending duodenum and the proximal jejunum. Specimens were compared for size, adequacy, and ability to confirm or exclude mucosal abnormality. Fourteen patients had villous atrophy. In all patients four biopsy specimens were obtained with paediatric endoscopic forceps and four with standard endoscopic forceps. No capsule biopsy specimen was retrieved from the duodenum in three patients and from the jejunum in five patients. Specimens were considered to be adequate in 36 patients when paediatric forceps were used, in 39 when standard forceps were used, in 28 on duodenal capsule biopsy, and in 32 on jejunal capsule biopsy. This study indicates that the most reliable method for diagnosing or excluding villous atrophy is endoscopic forceps biopsy of the descending duodenum, provided that at least four specimens are obtained with standard size forceps.

Adult↗

Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument.

A recently developed method of minimally invasive breast biopsy involves use of a directional, vacuum-assisted instrument. Use of this instrument requires some changes in techniques and applications of breast biopsy, but it enables confident biopsy of breast lesions under both ultrasound (US) and stereotactic guidance. The device uses vacuum to pull tissue into the probe and to remove the specimen without withdrawing the probe each time. For stereotactic biopsy, to target the lesion, the probe is placed anterior or posterior to the lesion and stereotactic positioning views are obtained; for a US-guided procedure, the probe is advanced posterior to the lesion. Next, the direction that the probe aperture must be rotated to face the lesion is determined. Tissue samples are obtained at consecutive clock positions of 1 1/2-hour intervals to achieve contiguous sampling. At least 15 samples are obtained with an 11-gauge probe to acquire a minimum of 1,500 mg of tissue. If postbiopsy images reveal that the lesion has been removed, a percutaneous clip is placed to mark the biopsy site for follow-up examination and possible further treatment. Patients are examined the next day and given the biopsy results and treatment considerations, if needed; they are followed up approximately 1 week later to detect any complications (eg, discomfort, ecchymosis). By learning how to perform a directional, vacuum-assisted biopsy with either stereotactic or US guidance, the radiologist has an additional, valuable tool for bringing accurate breast biopsy to his or her community.

Biopsy, Needle↗

Biopsy of amorphous breast calcifications: pathologic outcome and yield at stereotactic biopsy.

PURPOSE: To assess the pathologic outcome of amorphous breast calcifications and the success of stereotactic biopsy for such lesions. MATERIALS AND METHODS: From July 1995 through February 2000, biopsy of all clustered amorphous calcifications not clearly stable for at least 5 years or in a diffuse scattered distribution was recommended. Logistic regression analysis was used to stratify the risk of malignancy by patient risk factors, calcification distribution, and stability. RESULTS: Calcifications were retrieved from 150 biopsies; 30 (20%) proved malignant and included 27 ductal carcinomas in situ and three low-grade invasive and intraductal carcinomas (2-5 mm). Another 30 (20%) yielded high-risk lesions, including 21 atypical ductal hyperplasia, eight atypical lobular hyperplasia, and one lobular carcinoma in situ. In 150 lesions, stereotactic biopsy was performed on 113 and aborted in 10. Calcifications were retrieved from all 113 stereotactic biopsies. Of those with calcification retrieval, there were three histologic underestimates (accuracy, 97%). Stereotactic biopsy spared a surgical procedure in 57 (46%) of 123 patients. Needle localization was required for 23 (15%) of 150 patients due to poor conspicuity. Five (45%) of 11 biopsies performed in women with ipsilateral breast cancer showed malignancy (P = .025). When multiple lesions of amorphous calcifications were present in one breast, sampling of one reliably predicted the outcome of others. CONCLUSION: We found a substantial rate of ductal carcinoma in situ and high-risk lesions associated with amorphous calcifications. Stereotactic biopsy can be successfully performed for the majority of subtle amorphous calcifications; however, only a minority were spared a surgical procedure.

Adult↗

Prostatic biopsy directed with endorectal MR spectroscopic imaging findings in patients with elevated prostate specific antigen levels and prior negative biopsy findings: early experience.

PURPOSE: To prospectively evaluate the accuracy of transrectal ultrasonography (US)-guided biopsy directed with magnetic resonance (MR) spectroscopic imaging in patients with an elevated prostate specific antigen (PSA) level and negative findings at prior biopsy by using subsequent biopsy results as the reference standard. MATERIALS AND METHODS: The committee on human research approved this study, and written informed consent was obtained. MR imaging and MR spectroscopic imaging were performed in 42 men (age range, 45-75 years; average age, 63.3 years; median age, 65 years) with negative findings at two or more prostatic biopsies and at digital rectal examination. MR spectroscopic data were rated on a scale of 1 (benign) to 5 (malignant) on the basis of standardized metabolic criteria. Abnormal voxels were overlaid on the corresponding transverse transrectal US images and used to perform voxel-guided biopsy of the prostate. All patients subsequently received an extended-pattern biopsy scheme. RESULTS: Thirty-one of 42 patients demonstrated metabolic abnormalities that were suspicious for cancer (voxels with scores > or = 4). Eleven patients with negative MR spectroscopic imaging results also had negative biopsy findings. Cancer was detected in 17 (55%) of 31 men with positive MR spectroscopic imaging findings (voxels with scores > or = 4) with a sensitivity of 100%, specificity of 44%, positive predictive value of 55%, negative predictive value of 100%, and accuracy of 67%. In men with at least one spectroscopic voxel with a score of 5 (12 of 17 men), the sensitivity, specificity, positive and negative predictive values, and accuracy were 71%, 84%, 75%, 81%, and 79%, respectively. CONCLUSION: Metabolic data from MR spectroscopic imaging can be transferred to transrectal US images and used to sample regions of cancer in men with rising PSA levels and negative findings at prior biopsy with good accuracy.

Aged↗

Add-on device for stereotactic core-needle breast biopsy: how many biopsy specimens are needed for a reliable diagnosis?

PURPOSE: To prospectively determine whether there is a minimum number of cores required for histopathologic diagnosis of mammographically detected nonpalpable breast lesions with an add-on 14-gauge stereotactic core-needle biopsy device. MATERIALS AND METHODS: The study was approved by the ethics committee of the hospital; informed consent was obtained. Biopsy was performed in 197 patients with 205 lesions (97 masses, 108 microcalcifications). The first sample (from the center) was collected in container A; second and third samples (2 mm from center), in container B; and additional samples, in container C. Malignancies, atypical ductal hyperplasia (ADH), and radial scars were excised. Benign lesions were followed up mammographically (mean, 24 months). Strict sensitivity and working sensitivity were calculated separately. Stereotactic biopsy with diagnosis of a nonmalignant lesion that, after surgery, proved to be malignant was considered false-negative when strict sensitivity was calculated. Stereotactic biopsy with diagnosis of ADH or radial scar was considered true-positive if the findings at surgery corresponded to the results at biopsy or indicated malignancy and was considered false-positive if the findings at surgery were benign when working sensitivity was calculated. Sensitivity, specificity, and overall accuracy of stereotactic biopsy were determined for masses and microcalcifications in all three containers by using surgical samples and findings at mammographic follow-up as reference. At chi2 analysis, P < .05 was considered to indicate significant difference. RESULTS: Strict sensitivity of the first sample was 77% (66 of 86) (90% [35 of 39] for masses, 66% [31 of 47] for microcalcifications). Results of the first sample were false-negative significantly more often in microcalcifications (n = 16) than in masses (n = 4) (P = .010). Combined results of containers A and B (ie, three samples) yielded higher strict sensitivity than those with first sample alone (95% [37 of 39] for masses [P = .196], 91% [43 of 47] for microcalcifications [P < .001]). With multiple samples, strict and working sensitivity were both 100% (39 of 39) for masses and 91% (43 of 47) and 98% (46 of 47), respectively, for microcalcifications. Four false-negative diagnoses (ADH, three cases; lesion with discordant mammographic and stereotactic biopsy findings, one case) were microcalcifications. CONCLUSION: More than three samples are needed (a minimum number was not determined) for a histologic diagnosis of a mass lesion by using an add-on stereotactic biopsy device.

Biopsy, Needle↗