Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “vertical connectivity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Infusion pump performance with vertical displacement: effect of syringe pump and assembly type.

OBJECTIVE: To evaluate the effect of different infusion pump models on continuity of drug delivery during vertical displacement of syringe pumps. DESIGN: Zero-drug delivery time (ZDDT), retrograde aspiration volume, and infusion bolus were recorded using the same syringe in three different models of syringe pump after lowering and elevating the pump. Compliance of each infusion assembly was measured using the occlusion release technique at 38 mmHg. RESULTS: Lowering the pump by 50 cm at an infusion rate of 1 ml/h resulted in ZDDT values ranging from 2.78 +/- 0.29 to 5.99 +/- 1.09 min. Elevating the syringe pump to its original position caused infusion boluses between 44.1 +/- 3.2 and 77.1 +/- 5.1 microl. The results demonstrated that there are large differences between syringe pump models (F = 66.8, df = 2/33, p < 0.0001) and between pumps of the same model (F = 21.3, df = 1/34, p < 0.0001). A similar pattern was found in retrograde aspiration volume and infusion bolus. CONCLUSION: All tested pumps led to clinically relevant flow irregularities during vertical displacement of the syringe pump. Thus, vertical displacement of any syringe pump connected to an infusion line delivering highly potent drugs at low infusion rates should be avoided. The variability across syringe pumps indicates that syringe pump design remains an area of potential further improvement for reducing the risk of adverse patient events.

Analysis of Variance↗

Hydro-resistive measurement of dynamic lifting strength.

A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with flexible wire rope via a series of pulleys to a piston suspended inside the tube. The piston has holes which can be closed with bungs. The drag force is proportional to the square of the velocity. The constant of proportionality can be chosen over a more than 100-fold range and is independent of temperature. Manual force is measured using a strain gauged cantilever over which the rope passes. Rope movement is monitored with a shaft encoder. These devices are sampled synchronously by an interfaced computer. Velocity and power are derived from the measurements of displacement, time and force. The device is highly accurate. Power measurements are not significantly different on two separate days although repetitions on one day show a warming-up effect. This device allows the study of dynamic lifts ranging from slow, high force, quasi-isokinetic lifts to lifts where high velocities and accelerations occur.

Biomechanical Phenomena↗

Information about three-dimensional shape and direction of illumination in a square-wave grating.

A homogeneous grey picture and a 'Mondrian' type of picture were illuminated by a projector with square-wave gratings of thirty different contrast values used as slides. Ten observers reported whether the picture appeared three-dimensional (3-D) (pleated) or flat. 3-D responses in this situation indicate colour constancy 'at the cost of' nonveridical depth perception. The frequencies of 3-D responses were significantly higher for the structured picture than for the homogeneous grey one. In reports of the direction from which the apparent 3-D object appeared to be illuminated there was a significant preference for responses "from above" when the grating was horizontally oriented. With vertical orientation there was no preference for "from the left" or "from the right". The results from the first experiment contradict traditional cue theories of depth perception since the projection of the borders between the fields of the structured picture was invariant and expected to inform about the flatness of the picture. They are, however, in line with a model for perceptual analysis of reflected light into common and relative components proposed earlier by Bergström. The difference in perceived direction of illumination between horizontally and vertically orientated gratings is discussed in connection with human ecology.

Color Perception↗

The vascular supply to the skin: an anatomical and physiological reappraisal--Part I.

We present a new concept of vascular anatomy, proposing that a complex subcutaneous vascular network, located between the dense and loose adipose tissue, connects the larger subcutaneous vessels, the vertical perforators, and the subdermal plexus. Knowledge of the location of these vessels helps determine optimal flap design and level of elevation. In this first of two articles, we describe the experimental portions of our study. The sequel describes the human experience and clinical implications.

Animals↗

Applied anatomy of transoral atlantoaxial reduction plate internal fixation.

STUDY DESIGN: A C1-C2 operation by the transoral approach was simulated to study the anatomic stratification, various structures, and adjacent relationships. The anatomic parameters in relation to transoral atlantoaxial reduction plate (TARP) internal fixation were measured. OBJECTIVES: To study relevant anatomic features of the structures involved in TARP internal fixation through transoral approach for treating irreducible atlantoaxial dislocation, so as to provide anatomic basis for the clinical application of TARP. SUMMARY AND BACKGROUND DATA: Irreducible anterior atlantoaxial dislocation (IAAD) with ventral spinal cord compression is difficult for surgical correction. Despite previous description of direct plate internal fixations through the transoral approach, the problem has not been fully resolved: the Harms' plate lacked a locking mechanism while the other plates unable to achieve immediate reduction of the atlantoaxial joint. We therefore designed the TARP system with which the decompression, reduction, internal fixation, and fusion procedures could be completed in the same transoral approach. The anatomic structures and stratification involved in the transoral approach, which were seldom addressed in previous anatomic studies, need to be clarified for internal fixation with TARP system. METHODS: Twenty fresh craniocervical specimens were microsurgically dissected layer by layer according to a transoral approach. Stratification of the posterior pharyngeal wall, course of the vertebral artery, anatomic relationships of the adjacent structures of the atlas and axis, and closely relevant anatomic parameters for TARP internal fixation were measured. RESULTS: The posterior pharyngeal wall consisted of two layers and two interspaces: the mucosa, prevertebral fascia, retropharyngeal space, and prevertebral space. The range from the anterior edge of the foramen magnum to C3 could be exposed by this approach. The thickness of the posterior pharyngeal wall was 3.6 +/- 0.3 mm (range, 2.9-4.3 mm) at the anterior tubercle of C1, 6.1 +/- 0.4 mm (range, 5.2-7.1 mm) at lateral mass of C1 and 5.5 +/- 0.4 (range, 4.3-6.5 mm) at the central part of C2, respectively. The distance from the incisor tooth to the anterior tubercle of C1, C1 screw entry point, and C2screw entry point was 82.5 +/- 7.8 mm (range, 71.4-96.2 mm), 90.1 +/- 3.8 mm (range, 82.2-96.3 mm), and 89.0 +/- 4.1 mm (range, 81.3-95.3 mm), respectively. The distance between the vertebral artery at atlas and the midline was 25.2 +/- 2.3 mm (range, 20.4-29.7 mm) and that between the vertebral artery at the axis and the midline was 18.4 +/- 2.6 mm (range, 13.1-23.0 mm). The allowed width of the atlas and axis for exposure was 39.4 +/- 2.2 mm (range, 36.2-42.7 mm) and 39.0 +/- 2.1 mm (range, 35.8-42.3 mm), respectively. The distance (a) between the two atlas screw insertion points (center of anterior aspect of C1 lateral mass) was 31.4 +/- 3.3 mm (range, 25.4-36.6 mm). The vertical distance (b) between the line connecting the two C1 screw entry points and that connecting the two C2 screw entry points (at the central part of the vertebrae, namely, 3 to 4 mm lateral to the midline of C2 vertebrae) was 21.3 +/- 2.7 mm (range, 19.4-24.3 mm), with an a/b ratio of 1.3 to 1.5. The screws of TARP had a lateral tilt of 12.2 degrees +/- 0.4 degrees (range, 10.2 degrees -14.6 degrees ) at C1 and a medial tilt of 7.3 degrees +/- 0.3 degrees (range, 5.1 degrees -9.4 degrees ) at C2 relative to the coronal plane. CONCLUSION: An atlantoaxial surgery through transoral approach is safe and feasible. This approach is suitable for an anterior TARP internal fixation, and the design of the internal fixation system should be based on the above anatomic data.

Atlanto-Axial Joint↗

Evaluation of hippocampal infolding using magnetic resonance imaging.

To investigate developmental morphological variation of the hippocampal formation, we evaluated the degree of hippocampal infolding in cross-sectional oblique coronal images of the cerebral peduncle and the superior cerebellar peduncle. We defined the hippocampal infolding angle as the angle between the vertical midline and the straight line connecting the medial superior margin of the subiculum with the lateral margin of the cornu ammonis. The angle increased slightly with age, and was larger in the superior cerebellar peduncle than in the cerebral peduncle and larger in the right superior cerebellar peduncle than in the left superior cerebellar peduncle. This suggests that this angle and its variation with age and location merit our attention in morphological evaluation of the hippocampal formation.

Adolescent↗

Origin of degree correlations in the Internet and other networks.

It has been argued that the observed anticorrelation between the degrees of adjacent vertices in the network representation of the Internet has its origin in the restriction that no two vertices have more than one edge connecting them. Here, we propose a formalism for modeling ensembles of graphs with single edges only and derive values for the exponents and correlation coefficients characterizing them. Our results confirm that the conjectured mechanism does indeed give rise to correlations of the kind seen in the Internet, although only a part of the measured correlation can be accounted for in this way.

Journal Article↗

Measuring larynx movement in standard Thia using the cricothyrometer.

Vertical movement of the larynx during connected speech was investigated in Standard Thai - a language that has five phonologically contrastive tones. The effects of pitch, consonant phonation-type, vowel quality, tonal categories, and position in the utterance were determined. Utterance position was found to be the factor most clearly associated with variations in larynx movement. The occurrence of an overall rise-fall pattern of larynx movement distributed over utterances of varying pitch patterns leads to the conclusion that larynx height is not a principal factor regulating pitch in connected speech. Implications for models of pitch production, distinctive features for tone, theories on the historical development of tone and the role of larynx movements in the production of consonants and vowels are discussed.

Adult↗

Interhemispheric connections between primary visual areas: beyond the midline rule.

In the last five years, a number of detailed anatomical, electrophysiological, optical imaging and simulation studies performed in a variety of non-human species have revealed that the functional organization of callosal connections between primary visual areas is more elaborate than previously thought. Callosal cell bodies and terminals are clustered in columns whose correspondence to features mapped in the visual cortex, such as orientation and ocularity, are starting to be understood. Callosal connections are not restricted to the vertical midline representation nor do they establish merely point-to-point retinotopic correspondences across the hemispheres, as traditionally believed. In addition, anatomical studies have revealed the existence of an ipsilateral component of callosal axons. The aim of this short review is to propose how these new data can be integrated into an updated scheme of the circuits responsible for assembling the primary visual field map.

Animals↗

Three-dimensional force measurements on mandibular implants supporting overdentures.

The purpose of this study was to determine masticatory and functional forces in three axes on mandibular implants supporting overdentures. Five edentulous test subjects were selected, each having two mandibular implants. Three-dimensional piezoelectric force transducers were mounted on the two-part ITI Bonefit implants and rigidly connected to the denture. Forces in vertical, lateromedial, and anteroposterior directions were measured by means of electrostatic plotter records. The test modalities were light tapping, grinding, maximal occlusal force, and chewing test food. Results showed that the five subjects developed similar stress patterns but quantitatively different occlusal and chewing forces. In all but one subject, reduced maximal occlusal force was found compared to dentate subjects and edentulous subjects with fixed partial prostheses supported by implants. The recordings of chewing cycles when eating test food resulted in very regular rhythmic strokes, similar to those of dentate subjects but with slightly reduced speed. All stress patterns showed that occlusal and chewing forces were mainly directed in vertical, medial, and anterior dimensions. The dominating component was vertical.

Aged↗

The anatomical study of transoral atlantoaxial reduction plate internal fixation.

OBJECTIVE: To study relevant anatomical features of the structures involved in transoral atlanto-axial reduction plate (TARP) internal fixation through transoral approach for treating irreducible atlanto-axial dislocation and providing anatomical basis for the clinical application of TARP. METHODS: Ten fresh craniocervical specimens were microsurgically dissected layer by layer through transoral approach. The stratification of the posterior pharyngeal wall, the course of the vertebral artery, anatomical relationships of the adjacent structures of the atlas and axis, and the closely relevant anatomical parameters for TARP internal fixation were measured. RESULTS: The posterior pharyngeal wall consisted of two layers and two interspaces: the mucosa, prevertebral fascia, retropharyngeal space, and prevertebral space. The range from the anterior edge of the foramen magnum to C(3) could be exposed by this approach. The thickness of the posterior pharyngeal wall was (3.6+/-0.3) mm (ranging 2.9-4.3 mm) at the anterior tubercle of C1, (6.1+/-0.4) mm (ranging 5.2-7.1 mm) at the lateral mass of C(1) and (5.5+/-0.4) mm (ranging 4.3-6.5 mm) at the central part of C(2), respectively. The distance from the incisor tooth to the anterior tubercle of C(1), C(1) screw entry point, and C(2)screw entry point was (82.5+/-7.8) mm (ranging 71.4-96.2 mm), (90.1+/-3.8) mm (ranging 82.2-96.3 mm), and (89.0+/-4.1) mm (ranging 81.3-95.3 mm), respectively. The distance between the vertebral artery at the atlas and the midline was (25.2+/- 2.3) mm (ranging 20.4-29.7 mm) and that between the vertebral artery at the axis and the midline was (18.4+/- 2.6) mm (ranging 13.1-23.0 mm). The allowed width of the atlas and axis for exposure was (39.4+/-2.2) mm (ranging 36.2-42.7 mm) and (39.0+/-2.1) mm (ranging 35.8-42.3 mm), respectively. The distance (a) between the two atlas screw insertion points (center of anterior aspect of C(1) lateral mass) was (31.4+/-3.3) mm (ranging 25.4-36.6 mm). The vertical distance (b) between the line connecting the two C(1) screw entry points and that connecting the two C(2) screw entry points (at the central part of the vertebrae, namely 3-4 mm lateral to the midline of C(2) vertebrae) was (21.3+/-2.7) mm (ranging 19.4-24.3 mm), with an a/b ratio of 1.3-1.5. The screws of TARP had a lateral tilt of 12.2 degrees+/-0.4 degrees(ranging 10.2 degrees-14.6 degrees) at C(1) and a medial tilt of 7.3 degrees+/-0.3 degrees (ranging 5.1 degrees-9.4 degrees) at C(2) relative to the coronal plane. CONCLUSIONS: An atlanto-axial surgery through transoral approach is safe and feasible. This approach is suitable for an anterior TARP internal fixation, and the design of the internal fixation system should be based on the above anatomical data.

Atlanto-Axial Joint↗

[Unusual total anomalous pulmonary venous connection; report of a case].

We report a case of a 7-hour-old infant with total anomalous pulmonary venous connection having abberant origin of the vertical vein. His clinical condition presented hemodynamically severe pulmonary vein obstruction as common pulmonary vein atresia. Without making the definitive diagnosis, he underwent the operation at 11 hours after birth under cardiopulmonary bypass. During the operation, we could not identify the drainage vein. Although we ligated the vessel sized less than 2 mm in diameter draining into superior vena cava which was suspected to be the vertical vein. After the operation pulmonary edema was severe, but his clinical condition improved by using nitric oxide without extracorporeal membrane oxygenation (ECMO) support. Postoperative cardiac catheterization showed normal cardiac function without pulmonary venous obstruction, and moreover identified the drainage vein originated from right upper pulmonary vein. To the best of our knowledge, this is the first case where the vertical vein originated from right upper pulmonary vein. Immediate surgical treatment before the circuratory exacerbation improve the outcome for this congenital anomaly.

Humans↗

[Studies on the halfside comparison of heterotopic transplantation of mucosa with and without epithelium].

In patients with symmetric recessions in their canine and premolar regions, one side was supplied with an epithelium-containing and the other with an epithelium-free graft from the hard palate. Both sides were studied and compared. After six months, the size of the connective tissue transplants was reduced by 50% (that of the epithelium transplants by 0%). Within half a year, the width of the attached gingiva had decreased by 36% in the case of connective tissue transplants (epithelium transplants by 15%) and the vertical graft width by 60% (epithelium transpltnas 17%). Our clinical and histological findings suggest that grafting of heterotopic connective tissue transplants is not equal to epithelium-containing transplants.

Adolescent↗

[The therapeutic orientation in vertical fractures of the patella].

Starting from the rareness of vertical fractures of the patella, in connection with a clinical case, the authors present this entity and the therapeutical problems in correction with this type of fracture. Interfragmentary diastasis is more than 3 mm, so the authors choose for treatment the osteosynthesis with a spongious screw placed horizontally, perpendicular on the fracture, keeping the integrity of the prepatellar fibrous planes. The authors appreciate that orthopedic treatment is reserved to the incomplete fractures or fractures without displacement.

Accidental Falls↗

Morphology and soma-dendritic distribution of synaptic endings from the rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF) on motoneurons in the oculomotor and trochlear nuclei in the cat.

The morphology and soma-dendritic distribution of anterograde biocytin-labelled rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF) synaptic endings in the oculomotor and trochlear nuclei have been examined by electron microscopy by using both preembedding immunoperoxidase and postembedding immunogold methods. The results indicate that three morphological types of riMLF synaptic endings are distinguishable on the basis of synaptic vesicle morphology (spheroidal, pleiomorphic, or ellipsoidal) and postsynaptic membrane specializations (asymmetrical or symmetrical). All three morphological types of riMLF synaptic endings establish synaptic connections predominantly with dendrites. Synaptic endings that contain ellipsoidal synaptic vesicles have a more proximal soma-dendritic distribution than those that contain either spheroidal or pleiomorphic synaptic vesicles. Furthermore, all three morphological types of synaptic endings are encountered in the same motoneuron subdivisions of the oculomotor and trochlear nuclei in the same experiments. The findings suggest that subregions of the riMLF contain coexistent populations of excitatory and inhibitory premotor neurons that are related to opposite directions of vertical saccadic eye movements but that project to the same motoneuron subgroups on the ipsilateral side. Both the morphology and the mode, pattern, and soma-dendritic distribution of saccade-related riMLF synaptic endings that establish synaptic connections with vertical motoneurons differ from those of excitatory and inhibitory second-order vertical vestibular synaptic endings. These differences in the synaptic organization of riMLF and second-order vestibular inputs to oculomotor and trochlear motoneurons may be related to differences in the information transferred by each source, the riMLF input conveying eye-velocity signals, and the vestibular input conveying eye-position signals.

Animals↗

Intrinsic connections of rat primary visual cortex: laminar organization of axonal projections.

The organization of local projections within the rat primary visual cortex (area 17) was investigated by tracing fibers with HRP in in vitro brain slices. The projections from different layers showed distinct laminar patterns. Layer 4 made a strong, topographically precise, projection to lower layer 2/3; weaker projections extended laterally and terminated diffusely in layer 2/3 but also ran vertically to layers 5 and 6. The connections of lower and upper layer 2/3 were reciprocal and point-to-point. Within layer 2/3, a large number of fibers ran horizontally and terminated at variable distances from the injection site without making terminal clusters. The main output from layer 2/3 was to layer 5. The most prominent projections from the upper half of layer 5 were to layers 2/3 and 6; lower layer 5, in contrast, made wide-ranging, clustered projections to layer 1, the bottom of layer 2/3, and the top of layers 4 and 5. The patches were 130-160 micron wide and spaced apart by 230-260 micron. The main projection that arose from the superficial layer 6 terminated in layer 4 above the injection site. In contrast, lower layer 6 made clustered projections to the layer 3/4 border, extending up to 2 mm in the coronal plane. The patches were 190-220 micron wide and spaced apart by 320-390 micron. Additional projections went to the layer 5/6 border and layers 1 and 2. These results indicate that geniculocortical input is processed through interlaminar connections that are topographically precise, widespread, or patchy. These connectivity patterns suggest a role for these connections in the transformation of functional maps between layers; focused projections preserve the architecture of the layers of origin, and diverging or patchy projections rearrange this organization and form new maps in the target layers (Lund: Annu. Rev. Neurosci. 11:253-288, '88). However, only a few interlaminar connections show one of these patterns in isolation, making it difficult to assign a single function to a particular connection. We, therefore, tentatively conclude that projections terminating in layers 1-4, with the possible exception of the connection between upper layer 6 and layer 4, transform functional maps. In contrast, the topographically precise projections from upper to lower layers preserve functional maps. The specific role of these connections in the construction of receptive field properties, however, is not known.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Anomalous subaortic course of the left brachiocephalic (innominate) vein: echocardiographic diagnosis and report of an unusual association.

Subaortic left brachiocephalic, or innominate, vein is an uncommon finding in congenital heart disease, usually associated with obstruction of the right ventricular outflow tract. We describe our experience with 14 patients in whom the lesion was identified echocardiographically, 12 of them with right ventricular obstruction, one with totally anomalous pulmonary venous connection in the absence of obstruction to the right ventricular outflow tract, and the final one with a normal heart. A precise diagnosis of this venous anomaly is of great importance, since it needs to be differentiated from a central pulmonary artery, a pulmonary venous confluence, or an ascending vertical vein in totally anomalous pulmonary venous connection. In patients referred for surgery without catheterization, an incorrect echocardiographic diagnosis could lead to disastrous surgical results.

Adolescent↗