Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “surface modification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Surface modification of polyurethane for promotion of cell adhesion and growth 1: surface photo-grafting with N,N-dimethylaminoethyl methacrylate and cytocompatibility of the modified surface.

Functional polyurethane (PU) surface was prepared by photo-grafting N,N-dimethylaminoethyl methacrylate (DMAEM) onto the membrane surface. Grafting copolymerization was conducted by the combined use of the photo-oxidation and irradiation grafting. PU membrane was photo-oxidized to introduce the hydroperoxide groups onto the surface, then the membrane previously immersed in monomer solution was irradiated by UV light. The X-ray photoelectron spectroscopy and water contact angle characterized the grafted copolymers and verified the occurrence of graft copolymerization. The results showed that UV irradiation could realize the graft copolymerization effectively. The grafted membrane showed minimal surface morphology. Human umbilical vein endothelium (HUVE) cells were seeded on the grafted surfaces. The performance of the surface in cell attachment correlated with the content of oxygen and nitrogen. Cells were spread more extensive and grown faster on the surface with lower degree of grafting.

Journal Article↗

Cell-surface modification with an iodinatible imidoester to enhance radiolabeling.

A procedure to enhance incorporation of radioactive iodine into cell-surface proteins is described. The effects of chemical modification of cells with the iodinatible haptens N-succinimidyl-3-(4-hydroxyphenyl) propionate (Bolton-Hunter reagent) and methyl-p-hydroxybenzimidate HC1 (Wood reagent) are compared. The Wood reagent, that does not alter the charge of the modified amino group, is superior in retention of cell viability and function. Cell-surface modification with the Wood reagent prior to radiolabeling is particularly useful for detecting antigens not readily iodinated using standard techniques.

Animals↗

Surface modification and patterning using low-energy ion beams: Si-O bond formation at the vacuum/adsorbate interface.

Modification of hydroxyl-terminated self-assembled monolayer (HO-SAM) surfaces by collision of low-energy (15 eV) hyperthermal Si(CH3)3+ ions is shown to lead to Si-O bond formation and terminal trimethylsilyl ether formation. Modification was verified by in situ mass spectrometry using chemical sputtering with CF3+ ions (70 eV), ex situ secondary ion mass spectrometric analysis (12 kV Ga+ primary ion beam), and through X-ray photoelectron spectroscopy by monitoring Si (2s). The nature of the surface modification was further established by analysis of synthetic SAM surfaces made up of mixtures of the trimethylsilyl-11-mercapto-1-undecane ether and various proportions of the hydroxyl-terminated mercaptan (11-mercapto-1-undecanol). These mixed surfaces, as well as the spectroscopic data, indicate that ca. 30% of the hydroxyl chains are covalently modified at saturation coverage. Analogous surface transformations are achieved using Si(CH3)2F+ and Si(CH3)2C6H5+.

Journal Article↗

Reduced thrombogenicity of nitinol stents--in vitro evaluation of different surface modifications and coatings.

The material and the surface patterns of intravascular stents play a pivotal role in activating platelets and triggering adherence of inflammatory cells that consecutively leads to renarrowing caused by neointimal hyperplasia. To improve these features, besides mechanical and chemical modifications, ways of masking the stent by covering have been developed. In addition, polymer-coated stents are used as vehicle for local drug delivery. But as substances used for this application are described to possess an inflammatory potential, this aspect has to be evaluated. In the present study we compared different approaches to surface alterations applied to a nitinol stent design. Besides commonly used techniques like passivation and electropolishing, we evaluated coatings with heparin, aluminium and a polyurethane polymer regarding their thrombogenic and inflammatory characteristics. By weaving thin elastomer fibres a graft was generated. The previously described Chandler loop was used to simulate arterial flow conditions ex vivo using rotating PVC tubings filled with human blood. All stents received 120 min of blood contact. To determine thrombocyte activation and inflammatory reaction, the platelet count and levels of beta-TG, TAT and PMN-elastase were assessed. Scanning electron microscopy was used to visualize the reactions. Mechanical polishing and passivation did not improve the stent surface characteristics while sandblasting, electropolishing and aluminium covering decreased activation of the coagulation cascade. In terms of thrombogenicity, the heparin coating had no beneficial effect. The lowest thrombogenic potential was found in the Polyurethane-coated stent group. All stents showed similar levels of polymorph nuclear granulocyte elastase except for the membrane design. While mechanical and chemical modifications are able to reduce thrombogenicity, coating with this particular polyurethane polymer seems to be superior to these approaches regarding the parameters assessed in this experimental setting. The Chandler loop is a valuable tool to test polymeric coatings ex vivo since these modifications may reduce drug performance by inducing inflammatory reaction themselves.

Alloys↗

Surface modification of mica due to titanium sputtering as studied by positron annihilation.

Study was conducted of surface structural modification of layered sheets of mica that had been subjected to titanium (Ti) sputter coating, use being made of a variable but mono energetic slow positron beam. Comparison has been drawn with the structure of pure muscovite mica sheet. Doppler broadening (DB) of the energy of annihilation radiation has been used as a parameter to assay changes in the surface characteristics within a depth profile of 500 angstroms. In support of these investigations, X-ray reflectivity data was used to assay titanium film thickness and the electron density profile of the film on mica. Finally, changes involving the surface micro-morphology of the system have been corroborated by scanning electron microscopy.

Journal Article↗

Surface modification for direct immunoprobes.

The modification of glass-type surfaces by several hydrophilic polymers of different molecular masses and functional properties [chitosan, dextran, poly(oxyethylene), poly(ethyleneimine) and poply(acrylamide)] with respect to the application for direct immunoprobes was investigated. Activation of the surface was carried out by silanisation and the polymers were coupled to the surface via amide bonds. The carboxyl derivative of a hapten was attached to the functional groups of the polymers by carbodiimide-activated coupling. As a reference system, the ligand was directly coupled to the silanised surface. Non-specific protein adsorption, specific binding of antibodies and regeneration were monitored by evaluation of reflectance spectra obtained by white light interference at a thin silica layer (RifS). All polymer modified layers showed improved properties compared to those with direct attachment of the hapten. The non-specific adsorption was reduced to 5-50%. Binding of a specific antibody was significantly increased by the polymer modification: Mass transport limited binding of the specific antibody in low concentrations (30 nM) up to a surface coverage value of 2 ng/mm2 and a maximum surface coverage in the range of a monolayer of IgG (5-6 ng/mm2) was observed for most of the polymers. The surface coverage found for IgG bound specifically to the dextran-modified surface exceeded a protein monolayer.

Adsorption↗

Surface modification of copolyether-urethane catheters with poly(ethylene oxide).

Pellethane 2363 80A catheters were modified with poly(ethylene oxide) in order to improve their blood compatibility. Contact angle measurements showed that Pellethane 2363 80A surfaces had increased wettability after this modification. The results of in vitro blood compatibility tests showed that surface modification with poly(ethylene oxide) resulted in a five-fold reduction of platelet deposition. Activation of coagulation was not affected.

Biocompatible Materials↗

Surface modifications of bioglass immersed in TRIS-buffered solution. A multitechnical spectroscopic study.

Bioglass 45S5 is used in the medical field as a bone regenerative material. In fact, when immersed in body fluid, a layer of hydroxy carbonate apatite (HCA), an analogue to the mineral phase that bones are made of, is deposited on its surface. A mechanism that would explain this process has been hypothesized and includes cation leaching from the glass to the solution and formation of both a silica-rich layer and a Ca/P-rich surface layer, prior to the actual crystallization of HCA. The present paper analyzes the dissolution of 2-mum-size particles of Bioglass in TRIS-buffered solution, focusing on the modifications occurring at the surface of the particles. Results from Transmission FT-IR, Raman, and X-ray Photoelectron Spectroscopy were compared in order to obtain this information. In all cases, precise spectral band assignments were obtained by comparing Bioglass spectra, before and after reaction, with the spectra registered on some selected reference samples. The results confirm the hypothesized mechanism of Bioglass reactivity and yield new insights on the surface modifications of the samples. In particular, the following is shown: the strength of the surface H-bonding system and of water coordination decreases during the reaction; surface carbonates, initially mainly bound to Na, are substituted by an increasing amount of Ca-bound carbonates; and the final calcium phosphate layer obtained is very similar, but not identical, to carbonated hydroxyapatite.

Ceramics↗

Surface modification of T-lymphocytes observed during rosetting.

Scanning electron microscopy has been used to characterize alterations of lymphocyte surface topology that occur on contact with erythrocytes during the rosetting reaction. Molt-4 cells, a line of leukemic human lymphocytes, defined as T-cells through their ability to form rosettes with sheep erythrocytes, were used for this. Unreacted Molt-4 cells exhibit surfaces that are virtually smooth and carry few microvilli. In contrast, Molt-4 cells in rosettes display a time-dependent modification of surface topology, characterized by the emergence of numerous, long microvilli, particularly in areas of red cell contact.

Animals↗

Surface modification of calcium hydroxyapatite with pyrophosphoric acid.

The surface of synthetic colloidal calcium hydroxyapatite (Ca(10)(PO(4))(6)(OH)(2); CaHap) was treated with pyrophosphoric acid (H(4)P(2)O(7); PP) in acetone and the materials were characterized by XRD, thermal analysis, N(2) adsorption, TEM, and FTIR. No remarkable change in XRD patterns or in particle morphology by the modification was observed. The additional amount of PO(4) of CaHap was increased with an increase in PP concentration. The Ca/P molar ratio of CaHap was decreased from 1.62 to 1.35 by the modification. IR results indicated that the PP reacts with surface P-OH groups of CaHap to form additional surface P-OH groups as follows: surface P-OH+H(4)P(2)O(7)--> surface P-O-PO(OH)(2) + H(3)PO(4). When the modified CaHap with Ca/P molar ratio less than 1.50 was treated at 850 degrees C in air, the materials transformed into beta-Ca(3)(PO(4))(2).

Diphosphates↗

[Research of plasma adsorption and action of platelet adhesion of Dacron modified by plasma surface modification].

In this paper, polyethylene glycol (PEG) of different molecular weight was grafted on the polyethylene terephthalate (PET, Dacron) films by plasma surface grafting modification. The competitive adsorption relation of plasma (fibrinogen and albumin) adsorbing on materials surface was analyzed in light of surface energy and interface free energy. The results indicated that the PET films grafted PEG long chain molecular possesses the characteristic of preferentially adsorbing albumin and this adsorption tendency of grafted PEG6000 sample is most distinct. The platelet adhesion tests of the PET films whose surfaces were pre-set in contact with fibrinogen and albumin indicated that the surface adsorbing albumin can distinctly inhibit platelet adhesion and aggregation and possess favorable blood compatibility, but the surface adsorbing fibrinogen can enhance platelet adhesion and aggregation.

Adsorption↗

Improved biological performance of Ti implants due to surface modification by micro-arc oxidation.

The surface of a titanium (Ti) implant was modified by micro-arc oxidation (MAO) treatment. A porous layer was formed on the Ti surface after the oxidation treatment. The phase and morphology of the oxide layer were dependent on the voltage applied during the oxidation treatment. With increasing voltage, the roughness and thickness of the film increased and the TiO(2) phase changed from anatase to rutile. During the MAO treatment, Ca and P ions were incorporated into the oxide layer. The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity increased, while the cell proliferation rate decreased. Preliminary in vivo tests of the MAO-treated specimens on rabbits showed a considerable improvement in their osseointegration capability as compared to the pure titanium implant.

Animals↗

Surface modification using silanated poly(ethylene glycol)s.

Surface-grafted poly(ethylene glycol) (PEG) molecules are known to prevent protein adsorption to the surface. The protein-repulsive property of PEG molecules are maximized by covalent grafting. We have synthesized silanated monomethoxy-PEG (m-PEG) for covalent grafting of PEG to surfaces with oxide layers. Two different trialkoxysilylated PEGs were synthesized and characterized. The first trialkoxysilylated PEG was prepared by direct coupling of m-PEG with 3-isocyanatopropyltriethoxysilane through a urethane bond (silanated PEG I). The other silanated PEG (silanated PEG II) containing a long hydrophobic domain between PEG and a silane domain was prepared by reacting m-PEG with 1,6-diisocyanatohexane and 10-undecen-1-ol in sequence before silylation with 3-mercaptopropyl trimethoxysilane. Silanated PEGs I and II were grafted onto glass, a model surface used in our study. The PEG-grafted glass surfaces were characterized by contact angle, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Although contact angle did not change much as the bulk concentration of silanated PEG used for grafting increased from 0.1 to 20 mg/ml for both PEGs I and II, the surface atomic concentrations from XPS measurements showed successful PEG grafting. Surface PEG grafting increased concentration of surface carbon but decreased silicone concentration. The high resolution C1s spectra showed higher ether carbon with lower hydrocarbon compositions for the PEG-grafted surfaces compared to the control surface. AFM images showed that more PEG molecules were grafted onto the surface as the bulk concentration used for grafting was increased. AFM images of the dried surfaces showed that the surfaces were not completely covered by PEG molecules. After hydration, however, the surface appears to be covered completely probably due to the hydration of the grafted PEG chains. Glass surfaces modified with silanated PEGs reduced fibrinogen adsorption by more than 95% as compared with the control surface. Silanated PEGs provides a simple method for PEG grafting to the surface containing oxide layers.

Adsorption↗

Metallic surface modification.

The potential beneficial effect of metal surface treatment using electrochemical polishing on stent thrombogenicity and neointimal hyperplasia was evaluated in a rat A-V model and a porcine coronary model. Thrombogenicity of polished stents (n=6) was compared to non-polished stents (n=5) in a rat A-V shunt model using 125I-fibrinogen and 51Cr-labelled platelets. Total clot weight after 30 min was significantly lower in the polished stents (32.1+/-2.8 vs 18.1+/-4.4: p<0.001). Also, 125I-fibrinogen deposition was significantly lower in the polished stents (1.30+/-0.07 vs 0.66+/-0.04: p<0.001). Platelet deposition was, however, not significantly reduced (12.7+/-3.4 vs 9.87+/-1.9, NS). Subsequently, the effect of electrochemical polishing on neointimal hyperplasia was evaluated in a porcine coronary model. Polished (n=10) and non-polished stents (n=10) were randomly implanted in the right coronary artery of healthy pigs. Neointimal hyperplasia was significantly decreased in the polished stents (0.56+/-0.28 vs 0.94+/-0.34 mm2: p<0.01).

Animals↗

Novel photoreactive surface modification technology for fabricated devices.

A novel surface process technology was developed to improve biocompatibility of fabricated devices, such as artificial blood pumps. The developed technology is based on photochemistry of a phenyl azide group, which is capable of covalently binding a synthetic polymer or protein to substrate surfaces upon ultraviolet (UV) irradiation. The photoreactive co-polymers or proteins, which were grafted or modified with phenyl azide groups, were successfully chemically fixed to surfaces. Photoreactive, hydrophilic copolymers with poly(dimethyl acrylamide) and albumin, both of which were chemically fixed on surfaces, were found effective for blood compatible surfaces; a fibronectin-bound surface was suitable for providing tissue compatibility. The quartz optical fiber guided UV irradiation system enables one to provide desired biocompatibility to a specific part of a fabricated device.

Artificial Organs↗

An aqueous-based surface modification of poly(dimethylsiloxane) with poly(ethylene glycol) to prevent biofouling.

We report a simple modification of poly(dimethylsiloxane) (PDMS) surfaces with poly(ethylene glycol) (PEG) through the adsorption of a graft copolymer, poly(l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) from aqueous solution. In this approach, the PDMS surface was treated with oxygen plasma, followed by immersion into aqueous solution containing PLL-g-PEG copolymers. Due to the hydroxyl/carboxylic groups generated on the PDMS surface after oxygen plasma, the polycationic PLL backbone is attracted to the negatively charged surface and PEG side chains exhibit an extended structure. The PEG/aqueous interface generated in this way revealed a near-perfect resistance to nonspecific protein adsorption as monitored by means of optical waveguide lightmode spectroscopy (OWLS) and fluorescence microscopy.

Adsorption↗

[Plasma immersion ion implantation. A new method for homogeneous surface modification of complex forms of medical implants].

Plasma immersion ion implantation (PIII) is a new method for the inexpensive rapid modification of the near-surface region of medical implants of complex shapes. PIII combines the advantages of conventional plasma and ion beam technologies. This article describes the physical basis of the procedure and the construction of a PIII system, and presents typical PIII parameters. In a number of examples, the use of the PIII to modify the surface of biocompatible materials (chrome-nickel stainless steel, titanium, titanium-aluminium-vanadium alloy) with the aim of reducing wear, increasing biocompatibility or improving adhesion, is described. Finally, the possibilities of combining PIII with other technologies are considered.

Biocompatible Materials↗

Surface modification of a polycarbonate-urethane using a vitamin-E-derivatized fluoroalkyl surface modifier.

Fluorinated surface-modifying macromolecules (SMMs) have been previously reported on and shown to limit the hydrolytic degradation of polyurethanes. The SMM molecules achieve this effect by allowing for the selective migration of terminal fluorinated groups to the polymer's surface, which may then shield more hydrolytically-sensitive groups in the base polyurethane backbone. A further extension of the SMM concept would be to utilize the migration of the fluorine tails to simultaneously deliver biologically active moieties to the surface. This study explored the synthesis and characterization of a vitamin-E (natural anti-oxidant) coupled surface modifier, as a model for the bioactive SMM concept. The SMM was synthesized using lysine diisocyanate (LDI), polycarbonate diol (PCN), and a fluoroalcohol. By derivatizing the LDI pendant ester, vitamin E was coupled to the SMM. The vitamin-E SMM was physically characterized using gel-permeation chromatography (GPC) and its anti-oxidant activity was assessed in the presence of 0.1 mM NaOCl. Polymer degradation experiments were carried out using 10 mM NaOCl incubation solutions, and the relative material breakdown was assessed using GPC and scanning electron microscopy (SEM). The results indicate that while the fluoro-component reduced damage of the PU, the bioactive component achieved a further deactivating effect. A similar action may also be effective against superoxide anions generated by human macrophages.

Biocompatible Materials↗