Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Usefulness of T1-weighted image with fast inversion recovery technique in intracranial lesions: comparison with T1-weighted spin echo image.

To evaluate the usefulness of T1-weighted images using the fast inversion recovery (T1FIR) technique as compared with routine T1-weighted spin echo (T1SE) images in various intracranial lesions. Routine spin echo and T1FIR images were performed in 15 consecutive patients with 18 lesions, cerebral infarction in five, astrocytoma in four, vascular lesion in three, encephalomalacia and hemorrhage in each two, arachnoid cyst and meningioma in each one. T1FIR images were performed with 1.5-T Signa [repetition time (TR)/echo time (TE)/inversion time (TI) was 2000/34/800 in 14, 4000/34/1200 in four lesions] and qualitatively compared with the T1SE images in signal intensity, lesion detectability, determination of lesion extent and conspicuity, contrast between lesion and background. Additionally, gray-to-white matter and cerebrospinal fluid (CSF)-to-white matter contrast were evaluated. The signal intensity of the lesions was similar on both T1FIR and T1SE images in all cases. The lesion detectability was similar on both sequences in 15 lesions, and the determination of the lesion extent was definitely higher in 16 lesions on the T1FIR images. Lesion conspicuity was superior in 11, similar in 5, and inferior in 2 patients on the T1FIR images. And also, contrast of lesion-to-background, gray-to-white matter, and CSF-to-white matter was superior on the T1FIR images. The T1FIR technique improved the determination of lesion extent and lesion conspicuity and was qualitatively superior for image contrast as compared with T1SE, but it takes more time than T1SE. The clinical application of T1FIR images depends on whether the superior aspect of the T1FIR images outweighs the disadvantage of the longer time required for this technique.

Brain↗

Subvoxel image registration of multislice (2D) magnetic resonance images in patients with high-grade gliomas of the brain.

AIMS: To implement a multislice two-dimensional (2D) T2-weighted sequence suitable for subvoxel image registration and to assess its usefulness in detecting change in high-grade intracranial gliomas. MATERIALS AND METHODS: Twenty patients with high-grade gliomas were studied on two or more occasions. T2-weighted multislice pulse sequences with a Gaussian slice profile, 50% overlapping slices and nearly isotropic voxels were acquired. The images were registered and subtraction images were produced. The images were compared with three-dimensional (3D) T1-weighted registered images and conventional unregistered T2-weighted images. All images were scored for changes in the lesions and ventricular system. RESULTS: The 2D and 3D registered subtraction images were the most sensitive for detecting changes in both the lesions and other regions in the brain. The mean rank scores were significantly higher for the lesions (chi2=86.742; df=5, n=38, P<0.0001) and for the ventricles (chi2=63.837; df=5, n=35, P<0.0001) compared with the unregistered and registered anatomical images. The subtraction images were also most sensitive for detecting signal intensity changes irrespective of the direction of change. CONCLUSION: Rigid body subvoxel registration can be successfully performed with both multislice 2D and 3D imaging. In principle, virtually all forms of clinical MR images of the brain can be accurately registered and subtracted.

Adult↗

Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment.

OBJECTIVE: The objective of this study was to reconstruct images bearing multiple contrasts from a single sequence magnetic resonance imaging (MRI) experiment. MATERIALS AND METHODS: Using a segmented IR-TrueFISP imaging sequence, the signal recovery after inversion and alpha/2 preparation was sampled in 6 volunteers. These images were used to generate T1, T2, and spin-density maps, allowing construction of images with multiple contrasts, including T1-, T2-, spin-density-weighted, and also FLAIR contrast. Traditionally acquired images bearing the corresponding contrast were obtained for comparison. Regression analysis was performed to compare the synthetic and traditionally acquired images for the whole brain and a region of interest in the occipital region. RESULTS: The synthetic images closely reproduced the contrast from the "standard" examination. Using regression analysis, the obtained image signal intensities for the calculated images compare favorably (P <0.0001-<<0.000001) with images acquired using multiple sequences. CONCLUSIONS: Perfectly registered images with any desired contrast based on T1, T2, and spin density, along with underlying quantitative maps, can be obtained using a single IR-TrueFISP sequence.

Brain↗

The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain.

A method to correct for geometric image distortion in the x-ray imaging chain, so-called dewarping, has been developed. A global two-dimensional polynomial model of which the degree is optimized is used. The performance of the method has been tested in a number of experiments using images of a plate with a 1 cm spaced wire grid put against the input screen of the x-ray image intensifier (14/17/27 cm). Both offline cine film and online video images were analyzed. The accuracy of the dewarp method was derived from the acquired images and from computer-simulated distorted images. The robustness and reproducibility of the dewarp method was evaluated by means of imaging the grid in various random orientations. Three parameters describing the behavior of the algorithm were considered. One is the reproducibility of the location of a dewarped position. The second parameter is the reproducibility of the distance between two adjacent dewarped positions as a measure of the reproducibility of the size of an object under investigation. The third parameter is the reproducibility of the pixel size in the plane of the calibration plate. The major results are: the reproducibility of the location of a dewarped position was 0.01-0.04 mm for cine film and 0.04-0.07 mm for video images. The coefficient of variation of the distance between two dewarped positions was 0.04%-0.11% for cine film and 0.15%-0.18% for video images. The dewarp algorithm turned out to be fast and accurate and the distortion was removed over the whole image field down to a low random residual level. It was found that a random orientation of the grid did not affect the assessment of the distortion nor its correction. The dewarp method proved to be intrinsically robust and highly reliable. Time instability of the imaging chain was the main source of variability in the dewarp results.

Algorithms↗

A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography.

A selenium based digital x-ray system dedicated to chest radiography has been installed by the UK Department of Health's Medical Devices Agency at Leeds General Infirmary, UK, to undergo a comprehensive evaluation, including the physical image quality. The underlying characteristics which define the overall image quality of a system are the following: sensitometric response, modulation transfer function, and noise power spectrum. These have been measured objectively on preprocessed digital data acquired under relevant radiographic conditions. The image data is further processed prior to hard copy display. The displayed image quality may only be measured subjectively; threshold contrast detail detectability is such a measure which can be related to the objective measures of image quality. The objective imaging characteristics suggest that Thoravision has a significant advantage over conventional radiography imaging systems. However, subjective measures have demonstrated that the image processing can have a significant effect on the perceived image quality. Thoravision has the potential to deliver a significantly improved image quality to clinicians with no increase in radiation exposure to the patient, or image quality may be maintained with a reduction in radiation exposure. Digital image processing is central to the efficiency with which it achieves this.

Biophysical Phenomena↗

Automated, real time extraction of fundus images from slit lamp fundus biomicroscope video image sequences.

AIMS: Slit lamp fundus biomicroscopy allows for high magnification, stereoscopic diagnosis, and treatment of macular diseases. Variable contrast, narrow field of view, and specular reflections arising from the cornea, sclera, and examining lens reduce image quality; these images are of limited clinical utility for diagnosis, treatment planning, and photodocumentation when compared with fundus camera images. Algorithms are being developed to segment fundus imagery from slit lamp biomicroscopic video image sequences in order to improve clinical utility. METHODS: Video fundus image sequences of human volunteers were acquired with a video equipped, Nikon NS-1V slit lamp biomicroscope. Custom developed software identified specular reflections based on brightness and colour content, and extracted the illuminated fundus image based on colour image analysis and size constraints. RESULTS: In five subjects with variable image quality, the approach allowed for automatic, robust, accurate extraction of that portion of the video image corresponding to the illuminated portion of the fundus. Non-real time analysis allowed for fundus image segmentation for each frame of the image sequence. In real time, segmentation occurs at 2 Hz, and improvements are being implemented for video rate performance. CONCLUSIONS: Computer vision algorithms allow for real time extraction of fundus imagery from marginal quality, slit lamp fundus biomicroscope image sequences.

Algorithms↗

MR imaging in acute stroke: diffusion-weighted and perfusion imaging parameters for predicting infarct size.

PURPOSE: To investigate the predictive value of the ischemic lesion size, as depicted in the acute stroke phase on diffusion-weighted magnetic resonance (MR) images and time-to-peak (TTP) maps of tissue perfusion imaging, for infarct size, as derived from T2-weighted imaging in the postacute phase. MATERIALS AND METHODS: Fifty patients who underwent diffusion-weighted and perfusion imaging within 1-24 hours after stroke onset and a follow-up T2-weighted investigation after about 8 days were included. Lesion volumes were evaluated by using a semiautomatic thresholding technique. Volumetric results of acute diffusion-weighted and perfusion imaging were analyzed in comparison with follow-up T2-weighted images and in terms of the time difference between symptom onset and initial MR imaging. RESULTS: At diffusion-weighted imaging, the acute lesion defined by a signal intensity increase of more than 20%, compared with the contralateral side, showed the best correlation with the infarct size after 1 week. At perfusion imaging, the best predictor relative to the contralateral side was a delay of more than 6 seconds on TTP maps. Temporal analysis of volumetric results, which depended on the time difference between symptom onset and examination, revealed two patient subgroups. CONCLUSION: Diffusion-weighted imaging helped to predict the size of the lesion on T2-weighted images obtained after about 8 days in patients with a symptom onset of more than 4 hours (r = 0.96), while in patients with a symptom onset of less than 4 hours, perfusion imaging provided important additional information about brain tissue with impaired perfusion.

Acute Disease↗

Endorectal MR imaging and MR spectroscopic imaging for locally recurrent prostate cancer after external beam radiation therapy: preliminary experience.

PURPOSE: To evaluate endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for the depiction of locally recurrent prostate cancer after external beam radiation therapy. MATERIALS AND METHODS: Endorectal MR imaging and MR spectroscopic imaging were performed in 21 patients with biochemical failure after external beam radiation therapy for prostate cancer. Two readers independently and retrospectively reviewed MR images and rated the likelihood of recurrent tumor on a five-point scale. Spectroscopic voxels were considered suspicious for malignancy if the choline level was elevated and citrate was absent. Receiver operating characteristic curve analysis was used to assess cancer detection in each side of the prostate with endorectal MR imaging and spectroscopic imaging at different thresholds based on the scores assigned by the two readers and on the number of suspicious voxels in each hemiprostate, respectively. The presence or absence of cancer at subsequent transrectal biopsy was used as the standard of reference. RESULTS: Biopsy demonstrated locally recurrent prostate cancer in nine hemiprostates in six patients. The area under the receiver operating characteristic curve for the detection of locally recurrent cancer with MR imaging was 0.49 and 0.51 for readers 1 and 2, respectively. By using the number of suspicious voxels to define different diagnostic thresholds, the area under the receiver operating characteristic curve for MR spectroscopic imaging was significantly (P < .005) higher, at 0.81. In particular, the presence of three or more suspicious voxels in a hemiprostate showed a sensitivity and specificity of 89% and 82%, respectively, for the diagnosis of local recurrence. Seven hemiprostates demonstrated complete metabolic atrophy at spectroscopic imaging and only postirradiation atrophy at biopsy. CONCLUSION: Preliminary data suggest that MR spectroscopic imaging, but not endorectal MR imaging, may be of value for the depiction of locally recurrent prostate cancer after radiation therapy.

Aged↗

MR imaging of the liver: breath-hold T1-weighted MP-GRE compared with conventional T2-weighted SE imaging--lesion detection, localization, and characterization.

PURPOSE: To compare breath-hold T1-weighted magnetization-prepared gradient-echo (MP-GRE) imaging with conventional T2-weighted spin-echo (SE) imaging in evaluation of focal liver disease. MATERIALS AND METHODS: Images of 68 patients evaluated for focal liver disease were reviewed. Five sets of images were analyzed: axial, sagittal, and coronal breath-hold T1-weighted MP-GRE images, axial T2-weighted SE images, and a compilation of axial, sagittal, and coronal (three-plane) T1-weighted MP-GRE images. Lesion signal intensity (SI) and signal difference-to-noise (SD/N) ratios were calculated. RESULTS: Lesions were detected, localized, and characterize more accurately (P < .05-.001) and with greater confidence on three-plane T1-weighted MP-GRE images than on almost all single-plane images. Mean SI ratios of nonsolid and solid lesions on MP-GRE and SE images were significantly different at all lesion sizes; mean SD/N ratio was significantly different only for large lesions. CONCLUSION: Lesion detection, localization, and characterization can be accurately and confidently performed with three-plane T1-weighted MP-GRE breath-hold imaging, potentially obviating conventional T2-weighted SE imaging.

Artifacts↗

Computed tomographic images and three-dimensional expression of crystalline lens findings from multiple slices of Scheimpflug slit images.

Although the observation of lens changes in clinical examination has been made through a slit lamp microscope under dilated pupil, precise documentation and analysis of lens changes are presently possible through Scheimpflug photographic images. However, the methodology is still unsatisfactory because the image analysis is two dimensional. In order to overcome this disadvantage, the authors aimed at developing a new methodology for obtaining computed tomographic images of the lens. 60 Scheimpflug slit images of a cataractous human lens were taken by an anterior eye segment analysis system as digital data. After the locations of the whole slit images had been matched, reconstruction of the coronal section line images was performed utilizing extracted image information. The total number of reconstructed coronal section images in additional procedures of the image interpolation was 150. Computed tomography of the lens image was made from those 150 images. A whole lens figure was also demonstrated as a moving three dimensional image.

Aged↗

MR evaluation of the anterior cruciate ligament: value of supplementing sagittal images with coronal and axial images.

OBJECTIVE: Most studies evaluating the anterior cruciate ligament have focused on sagittal MR images for the diagnosis of injury. Limitations of sagittal images have been reported, however, including nonvisualization and incomplete visualization of the ligament. This study was undertaken to assess the value of adding coronal and axial MR images to sagittal images in the evaluation of the anterior cruciate ligament. MATERIALS AND METHODS: We reviewed oblique sagittal T1-weighted, coronal T2-weighted, and axial T2-weighted images to determine the status of the anterior cruciate ligament in 325 patients. All patients had arthroscopy. Sagittal images were initially interpreted alone and then in combination with coronal and axial images. RESULTS: Sagittal T1-weighted images alone had a 94% sensitivity and an 84% specificity for determining the status of the anterior cruciate ligament. A multiplanar evaluation of the anterior cruciate ligament resulted in a change in MR interpretation in 21 patients (6%), which led to an improved sensitivity of 98% and a specificity of 93%. Diagnostic confidence was improved in an additional 14 patients (4%). CONCLUSION: Our results show that the efficacy of MR imaging for the detection of anterior cruciate ligament tears is greater when axial and coronal images are used in combination with sagittal images than when sagittal images are used alone.

Adult↗

Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

OBJECTIVE: The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS: Fifty-three patients with 108 focal hepatic masses had, prospectively, MR of the liver at 1.5 T. T2-weighted fast spin-echo (6000/117 [TR/effective TE]; echo train length=16; acquisition time = 3 min 12 sec) images obtained with and without fat suppression, T2-weighted BHFSE (2700/105; echo train length = 20; acquisition time = 22 sec), and 3D rapid GRE images (10.1/1.9/30 degrees [TR/TE/alpha]) obtained during one breath-hold (12 scan locations in 21 sec or 20 scan locations in 32 sec) before and after injection of gadolinium chelate were blindly and independently analyzed in consensus by three readers. RESULTS: Gadolinium chelate-enhanced 3D rapid GRE images allowed depiction of more focal hepatic masses (90 of 108, sensitivity = 83%) than did T2-weighted fast spin-echo with fat suppression images (76 of 108, sensitivity = 70%), T2-weighted fast spin-echo without fat suppression images (74 of 108, sensitivity = 69%), T2-weighted BHFSE images (73 of 108, sensitivity = 68%), and unenhanced 3D rapid GRE images (54 of 108, sensitivity = 50%) (p < .01). No difference in sensitivity was found between the three T2-weighted sequences. CONCLUSION: Gadolinium chelate-enhanced 3D rapid GRE imaging is superior to T2-weighted fast spin-echo images obtained with or without fat suppression for the detection of focal hepatic masses. T2-weighted BHFSE is similar to T2-weighted fast spin-echo images in detecting focal hepatic lesions.

Adult↗

Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography.

OBJECTIVE: The purpose of this study was to determine if tissue harmonic imaging (THI) sonography produced higher quality images than did conventional sonography. SUBJECTS AND METHODS: A prospective study was performed on 89 patients to compare the image quality of THI sonography with that of conventional sonography. Each examination was performed using THI sonography (transmitted frequency, 2.0 MHz; received frequency, 4.0 MHz) and conventional sonography at 2.5 and 4.0 MHz. The pancreatic area was studied in 60 patients, and other anatomic areas were studied in 68 patients. The images were then graded for penetration, detail, and total image quality. Graders were unaware of the sonographic technique. RESULTS: Of the 60 pancreatic examinations, THI sonography was the best technique for penetration in 45, detail in 54, and total image quality in 50. For the pancreas, THI sonography was significantly better than 2.5-MHz conventional sonography for penetration (p = .0002), detail (p < .0001), and total image quality (p < .0001). THI sonography was significantly better than 4.0-MHz conventional sonography for penetration (p < .0001), detail (p < .0001), and total image quality (p < .0001). Of the 68 examinations of other anatomic areas, THI sonography was the best technique for penetration in 42, detail in 57, and total image quality in 58. For other anatomic areas, THI sonography was significantly better than 2.5-MHz conventional sonography for penetration (p = .05), detail (p < .0001), and total image quality (p < .0001). THI sonography was significantly better than 4.0-MHz conventional sonography for penetration (p < .0001), detail (p < .0001), and total image quality (p < .0001). CONCLUSION: The THI technique improved sonographic image quality.

Aged↗

Benefits of perfusion MR imaging relative to diffusion MR imaging in the diagnosis and treatment of hyperacute stroke.

BACKGROUND AND PURPOSE: The development of thrombolytic agents for use with compromised cerebral blood flow has made it critical to quickly identify those patients to best treat. We hypothesized that combined diffusion and perfusion MR imaging adds vital diagnostic value for patients for whom the greatest potential benefits exist and far exceeds the diagnostic value of diffusion MR imaging alone. METHODS: The cases of patients with neurologic symptoms of acute ischemic stroke who underwent ultra-fast emergent MR imaging within 6 hours were reviewed. In all cases, automatic processing yielded isotropic diffusion images and perfusion time-to-peak maps. Images with large vessel distribution ischemia and with mismatched perfusion abnormalities were correlated with patient records. All follow-up images were reviewed and compared with outcomes resulting from hyperacute therapies. RESULTS: For 16 (26%) of 62 patients, hypoperfusion was the best MR imaging evidence of disease distribution, and for 15 of the 16, hypoperfusion (not abnormal diffusion) comprised the only imaging evidence for disease involving large vessels. For seven patients, diffusion imaging findings were entirely normal, and for nine, diffusion imaging delineated abnormal signal in either small vessel distributions or in a notably smaller cortical branch in one case. In all cases, perfusion maps were predictive of eventual lesions, as confirmed by angiography, CT, or subsequent MR imaging. CONCLUSION: If only diffusion MR imaging is used in assessing patients with hyperacute stroke, nearly one quarter of the cases may be incorrectly categorized with respect to the distribution of ischemic at-risk tissue. Addition of perfusion information further enables better categorizing of vascular distribution to allow the best selection among therapeutic options and to improve patient outcomes.

Aged↗

Attenuation correction for myocardial perfusion imaging. A comparison between SPECT and PET imaging by polar map analysis.

AIM: We investigated the impact of photon attenuation in myocardial perfusion imaging with SPECT and PET in patients with coronary artery disease. In fact, the regional tracer distribution can be quantitatively assessed by polar map analysis if the effects of photon attenuation are accounted for. PET imaging permits accurate measurement of and correction for photon attenuation, whereas results of attenuation correction in SPECT imaging have been inconsistent. PATIENTS, METHODS: We compared photon attenuation in resting perfusion imaging studies with SPECT ((99m)Tc-sestamibi) and PET ((13)N-ammonia) from 21 patients. Transaxial images were reconstructed with and without attenuation correction and reoriented into short axis images. Polar map analysis was utilized to generate regional tracer uptake in six anatomical segments. RESULTS: Average segmental photon attenuation calculated as the ratio of counts in corrected and uncorrected images was 7.2 +/- 1.4 in SPECT and 14.0 +/- 3.1 in PET imaging (p < 0.01). This attenuation factor was significantly related to body mass index for both methods (p < 0.001). While attenuation correction for SPECT imaging did compensate for attenuation effects in the inferior wall (from -15% to +6% vs. PET), relative tracer uptake in the anterior wall in SPECT images was significantly reduced after attenuation correction (from -2% to -18% vs. PET, p < 0.01). CONCLUSION: Differential effects of attenuation correction for myocardial SPECT perfusion imaging need to be considered when algorithms designed to compensate effects of photon attenuation in SPECT imaging are employed in clinical practice.

Aged↗

An image-dependent Metz filter for nuclear medicine images.

To provide optimal image quality, digital filters should account for both the count level and the object imaged. That is, they should be image-dependent. By using the constraint equation of constrained least-squares (CLS) restoration to determine one parameter of the Metz filter, a filter which adapts to the image has been developed. This filter has been named the Constrained Least-Squares Metz filter. The filter makes use of a regression relation to convert the Metz filter parameter determined using the CLS criterion to the value which would minimize the normalized mean square error (NMSE). The regression relation and the parameters which specify the general form of the Metz filter were determined using images of the Alderson liver and spleen phantoms. The designed filter was tested for its ability to adapt to other objects with images from each of three different test objects. When the values of the Metz filter parameters for these images determined by the CLS-Metz filter were compared by a regression analysis to those which minimized the NMSE for each image, a correlation coefficient of 0.98, a slope of 0.95, and a zero intercept of 0.1 were obtained. With clinical images, the CLS-Metz filter has been shown to provide consistently good image quality with images as diverse as heart perfusion images and bone studies.

Filtration↗

[Myocardial imaging with thallium-201--subtraction imaging with 201TlCl and 99mTcO4- for the visualization of the right ventricle--(author's transl)].

The dual radioisotope techniques with 201TlCl and 99mTcO4- were performed in 30 cases inclusive of various heart and lung diseases, using a scintillation camera coupling to a small digital computer. The scintigraphic procedures were started about 5 minutes after intravenous injection of 201TlCl. The myocardial images such as anterior, 60 degrees left anterior oblique, and left lateral view, were obtained. Next, 30 degrees left anterior oblique view was taken and radionuclide angiogram with 99mTcO4- was done in the same position too. This joint use of the myocardial imaging and radionuclide angiography could increase diagnostic reliability. Superimposing the image as iso-count map extracted out of radionuclide angiogram to the brightness image of 201TlCl, the anatomic orientation of the image of 201TlCl was improved. Subtracting the blood pool image with 99mTcO4- or radionuclide angiogram, which showed visualization of the right ventricle, lungs and left ventricle, from the image of 201TlCl, the subtraction image was obtained. The right ventricle was visualized more clearly on this subtraction image than the original image of 201TlCl. Good visualization of the right ventricle was shown in 25 cases on the subtraction image, and in 17 cases on the original image of 201TlCl.

Adult↗

Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion imaging agent: implications for a one-day imaging protocol.

Tetrofosmin is a 99mTc-labeled myocardial perfusion imaging agent that has shown encouraging results in Phase I and II clinical trials. The purpose of this study was to determine the biokinetics of this agent following administration during exercise and at rest in order to determine an optimal imaging protocol. Twenty patients with suspected coronary artery disease underwent symptom-limited treadmill exercise. Six to 8 mCi of 99mTc-tetrofosmin was injected at peak exercise and 22-24 mCi was injected 4 hr later at rest. Serial 5-min planar images were obtained in the left anterior oblique view at 5, 10, 15, 30, 60, 120 and 180 min after the radiotracer injection. Regions of interest were drawn on the serial images around the entire heart and portions of liver, lung, spleen, gallbladder and gastrointestinal tract. Average decay-corrected counts per pixel in each organ were plotted against time. In addition, heart-to-adjacent organ ratios were also determined. On stress images, the heart had the highest activity at all times, with the exception of gallbladder in the first 15 min. On rest images, the gallbladder, liver and gastrointestinal tract initially had higher activity than the heart; but the activity in these organs cleared rapidly over the subsequent 30-60 min. Heart-to-adjacent organ ratios were > 1.0 at all times in the stress images. Heart-to-organ ratios were < 1.0 in the first 15 min on the rest images for the liver and gastrointestinal tract. However, 30 min later, all ratios on the rest images were > or = 1.0. Technetium-99m-tetrofosmin images were considered to be of good to excellent quality with good myocardial delineation and adequate contrast between the heart and background. These These observations indicate that a convenient one-day tetrofosmin imaging protocol similar in duration to conventional 201Tl imaging is feasible.

Adult↗