On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems.

OBJECTIVE: To compare film for intra-oral radiography with two charge-coupled device (CCD) and one storage phosphor system for digital imaging in respect of subjective image quality, detectability of small mass differences and appearance of burn-out effects and blooming phenomena at various exposure times. METHODS: Dried mandibles with teeth from different areas were radiographed at exposures covering a relative range from 1 to 100. Image quality was subjectively evaluated after image processing, when applicable, using a visual grading scale from 0 to 10. The number of visible holes in an aluminium block was used to measure the detectability of small mass differences. Burn-out effects and blooming were evaluated by measuring widths of roots and of aluminium and plastic cylinders. RESULTS: Radiographs with the storage phosphor system achieved image quality scores similar to those of film but over a larger exposure range, while CCD images were rated lower and over a smaller range. All holes in the aluminium block were only detected with the storage phosphor system. While the widths of roots were strongly affected by sensor saturation in CCD images and by burn-out in film images, smaller effects were seen with the storage phosphor system. Similar results were obtained with aluminium and plastic cylinders. CONCLUSIONS: Higher image quality was achieved over a much wider exposure range with the storage phosphor system than with either film or the CCD systems.

Humans↗

The dynamic range of digital radiographic systems: dose reduction or risk of overexposure?

OBJECTIVES: To investigate the range of diagnostically acceptable digital radiographs and film as a function of exposure time, as well as the relationship to dose reduction and consequences for dental practice. METHODS: Five systems for intraoral radiography were used to take a series of radiographs, with increasing exposure times, of five different dry bone specimens. Seven observers evaluated the 25 series of radiographs. The observers had to determine which radiographs of each series were acceptable for dental diagnostics and which radiograph of each series they preferred. RESULTS: For Ektaspeed Plus film, the exposure time for the preferred radiograph was 0.52 s, with a range of diagnostically acceptable radiographs from 0.23-1.02 s. The preferred radiograph of the solid-state systems required less radiation than film (Sirona, 0.13 s; MPDx 0.35 s). The exposure range of these systems is narrow. In contrast, the exposure range of the phosphor plate systems is very wide. The preferred radiograph of the phosphor plate systems required high exposure (Digora, 1.21 s; Gendex DenOptix, 1.16 s). CONCLUSIONS: All digital systems require less exposure than film for diagnostically acceptable radiographs, but this is less obvious for preferred radiographs. Solid-state systems alert the dentist when a too long exposure time is used by a lack of image quality; phosphor plate systems, however, produce good quality radiographs even at high exposure times, which may result in an unnecessarily high dose.

Analysis of Variance↗

Spectral interferometric microscope with tandem liquid-crystal Fabry-Perot interferometers for extension of the dynamic range in three-dimensional step-height measurement.

The maximum measurable range of a spectral interference microscope depends on the coherence length of the light transmitted by its tunable spectral filter. To achieve a large range in step-height measurement we have developed a new tunable spectral filter that uses tandem liquid-crystal Fabry-Perot interferometers (LC-FPIs), which can simultaneously attain both a high spectral resolution and a large tuning range. Fringe visibility measurements were carried out, and it was found that the coherence length of the light transmitted through tandem LC-FPIs is two times larger than that transmitted through a single LC-FPI. Using this novel tunable spectral filter, we developed a new spectral interference microscope for the measurement of three-dimensional shapes of discontinuous objects. Experimental results of step-height measurements both with a single LC-FPI and with tandem LC-FPIs are presented for a combination of standard steel gauge block sets with 1-, 99-, and 100-microm steps. A large range (1-100 microm) of measurement with submicrometer resolution was achieved with tandem LC-FPIs that was not possible with our previous system in which a single LC-FPI was used.

Journal Article↗

Dynamic range of the frequency response of the horizontal vestibulo-ocular reflex of the alert rhesus monkey.

The vestibulo-ocular reflex (VOR) of the alert rhesus monkey was studied using rotational acceleration in the horizontal plane. Both sinusoidal and pseudorandom binary sequence (PRBS) stimuli were used to perform parameters. Results from sinusoidal studies over the frequency range 0.01 to 1.28 Hz, with stimulus amplitudes ranging from 16 to 256 degrees/second were consistent with a linear model of the VOR. Results PRBS stimuli whose bandwidths extended from 0.008 to 0.45 Hz with amplitudes of 4 to 256 degrees corroborated the sinusoidal results. Sinusoidal data obtained at high rotational frequencies indicated that a peak VOR gain occurred at approximately 4 Hz. Close agreement between sinusoidal and PRBS data suggested that the rhesus VOR does not manifest the predictive behavior reported in studies of smooth pursuit eye movements.

Acceleration↗

Liquid chromatography-electrospray mass spectrometry of beta-carotene and xanthophylls. Validation of the analytical method.

The investigation of beta-carotene and the xanthophylls beta-cryptoxanthin, lutein, zeaxanthin, canthaxanthin and astaxanthin using reversed-phase liquid chromatography-electrospray mass spectrometry interfaced with TurboIonspray (LC-TurboISP-MS) is described. Two narrow-bore C18 columns connected in series and an isocratic solvent system containing acetonitrile-methanol (0.1 M ammonium acetate)-dichloromethane at a flow-rate of 300 microl/min (without splitting) were used. Operating in the positive-ion mode over m/z 500-650, the effects on the formation of the molecular ion species or adduct ions and the MS detector response were investigated for carotenoids, varying the orifice plate voltage, the ring voltage and the ISP voltage. Both conventional ISP and TurboISP were performed; using the TurboISP-MS system, ionization efficiency increased with respect to ISP-MS, particularly at the highest temperature (500 degrees C). Good results were particularly obtained for beta-carotene, which was detectable at the low ng level, without the use of solution-phase oxidants. Using LC columns and acquiring in single-ion monitoring mode, detection limits were estimated to be in the 0.1-1 ng range; dynamic range was established between one- and two-orders of magnitude. Better sensitivity under positive-ion than negative-ion conditions was demonstrated.

Chromatography, High Pressure Liquid↗

Acoustic voice analysis in patients with Parkinson's disease treated with dopaminergic drugs.

To quantify several acoustic features of the voice in patients with Parkinson's disease (PD), 41 patients and 28 age and sex-matched controls were studied. PD severity was assessed with the Unified PD Rating Scale (UPDRS) and the Hoehn and Yahr staging. The Computerized Speech Lab 4300 program (Kay Elemetrics) was used. Two seconds of a sustained /a/ and a sentence were captured with a microphone and laryngograph equipment. Measures included fundamental frequency (F0), frequency perturbation (jitter), intensity perturbation (shimmer), and harmonic/noise ratio (H/N) of the vowel /a/, and frequency and intensity variability of a sentence, phonational range, dynamic range at the natural frequency, maximum phonational time and s/z ratio. All subjects underwent indirect laryngoscopy and/or laryngeal fibroscopy. When compared with controls, PD patients showed higher jitter, lower H/N ratio, lower frequency and intensity variability of the sentence, and lower phonational range and reported a higher frequency of the presence of low voice-intensity, monopitch, voice arrests, and struggle. These features seem to be unaffected by the duration and severity of the disease.

Aged↗

Dynamic Kerr effect responses in the terahertz range.

Dynamic Kerr effect measurements provide a simple realization of a nonlinear experiment. We propose a field-off experiment where an electric field of one or several sinusoidal cycles with frequency omega is applied to a sample in thermal equilibrium. Afterwards, the evolution of the polarizability is measured. If such an experiment is performed in the terahertz range it might provide valuable information about the low-frequency dynamics in disordered systems. We treat these dynamics in terms of a Brownian oscillator model and calculate the Kerr effect response. It is shown that frequency-selective behavior can be expected. In the interesting case of underdamped vibrational motion we find that the frequency dependence of the phonon damping can be determined from the experiment. Also the behavior of overdamped relaxational modes is discussed. For typical glassy materials we estimate the magnitude of all relevant quantities, which we believe will be helpful in experimental realizations.

Journal Article↗

Acoustic voice analysis in patients with essential tremor.

To quantify several acoustic features of the voice in patients with essential tremor (ET), 28 patients and 28 age- and sex-matched controls were studied. ET severity was assessed with the rating scale for tremor of Fahn, Tolosa, and Marín. The Computerized Speech Lab 4300 program (Kay Elemetrics) was used. Two-second samples of a sustained /a/ and a sentence were captured with a microphone and laryngograph equipment. Measures included fundamental frequency (F0), frequency perturbation (jitter, Koike algorithm), intensity perturbation (shimmer, Horii algorithm), and harmonic-to-noise ratio (H/N, Yumoto algorithm) of the vowel /a/, and the frequency and intensity variability of the sentence, phonational range, and dynamic range at the natural frequency, maximum phonational time, and s/z ratio. All subjects underwent indirect laryngoscopy and/or laryngeal fibroscopy. When compared with controls, ET patients showed higher jitter, lower H/N ratio (the last one only with laryngographic signal), of the vowel /a/, lower frequency variability in the microphonic signal, lower intensity variability in the laryngographic signal of the sentence, and significantly lower dynamic range at natural frequency of phonation. ET patients reported higher frequency of the presence of high voice intensity, tremor, and struggle. Several acoustic parameters were influenced by the severity of the disease, including shimmer, jitter, H/N ratio, frequency variability of the sentence, and s/z ratio, although neither of the acoustic analysis values or the phonetometric measurements were affected by the presence of voice tremor or by a successful pharmacological treatment of ET.

Aged↗