Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “continuous space simulations”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

A mathematical approach enabling the calculation of the total endolymph flow in the semicircular ducts.

1. A mathematical treatment of the flow inside the vertebrate labyrinth is given. The main difference to former theories (e.g. the "torsion pendulum" theory) is that the entire system formed by the three semicircular ducts, interconnected by the crus commune and the utriculus, is considered, instead of a single duct circuit. 2. The theory consists of a geometrical description of a labyrinth rotating in space, the solution of the continuity equation, determination of the initial velocities in all the ducts in a "cupulometry" experiment and derivation of the equation of motion (e.o.m.). 3. Equations for a system consisting of two ducts and for the classical single-duct system are special cases of the three-duct system. 4. Three different methods for the solution of the e.o.m. are described: an analytical one, a Runge-Kutta simulation and an "asymptotic" method. The last method includes approximations of the solution of the e.o.m. on a long and a short time scale. Its advantage is that it gives an insight based on rather manageable formulae. 5. The physiological basis of the presented theory, biological applications and verification are given in a separate paper (Muller & Verhagen, 1988).

Animals↗

Feature selection for structure-activity correlation using binary particle swarms.

We present a new feature selection algorithm for structure-activity and structure-property correlation based on particle swarms. Particle swarms explore the search space through a population of individuals that adapt by returning stochastically toward previously successful regions, influenced by the success of their neighbors. This method, which was originally intended for searching multidimensional continuous spaces, is adapted to the problem of feature selection by viewing the location vectors of the particles as probabilities and employing roulette wheel selection to construct candidate subsets. The algorithm is applied in the construction of parsimonious quantitative structure-activity relationship (QSAR) models based on feed-forward neural networks and is tested on three classical data sets from the QSAR literature. It is shown that the method compares favorably with simulated annealing and is able to identify a better and more diverse set of solutions given the same amount of simulation time.

Algorithms↗

Two-dimensional statistical model for regularized backprojection in SPECT.

In SPECT, both the noise affecting the data and the discretization of the inverse Radon transform are responsible for the ill-posed nature of the reconstruction. To constrain the problem, we propose a regularized backprojection method (RBP) which takes advantage of the relationships existing between the continuity properties of the projections and those of the reconstructed object. The RBP method involves two stages: first, a statistical model (the fixed-effect model) is used to estimate the noise-free part of the projections. Then, the filtered projections are reconstructed using a backprojection algorithm (spline filtered backprojection) which ensures that the reconstructed object belongs to a space consistent with that containing the projections. The method is illustrated using analytical simulations, and the RBP approach is compared to the conventional filtered backprojection. The effect on the reconstructed slices of the parameters involved in RBP is studied in terms of spatial resolution, homogeneity in uniform regions and quantification. It is shown that appropriate combinations of these parameters yield a better compromise between homogeneity and spatial resolution than conventional FBP, with similar quantification performances.

Algorithms↗

["Spatial shift alignment (SSA)"--a new method for determining blood flow velocity in video capillary microscopy].

A new technique (spatial shift alignment [SSA]) for measuring capillary blood velocity in human capillaries in the skin is described. A capillaroscopic image is digitized by means of a frame grabber. Within the lumen of a suitable capillary limb a region of interest known as a slot is placed. At a frame frequency of 25 per second, this slot is copied in a free part of the frame grabber store along a horizontal axis. A static space-time image with light diagonal bands representing the plasma gaps in their passage through the capillary limb is obtained. By determining the gradient of the diagonal bands, a measure of the capillary blood velocity is obtained. The SSA system was validated by means of a simulated model using known fixed velocities between 0 and 1.0 mm/sec (r = 0.979, n = 24). The procedure can be employed with any image processing systems, and enables continuous monitoring of the velocity measurements. Since it is time-saving and just as accurate as the frame-to-frame method, SSA could be widely applied to the measurement of blood cell velocity in capillaroscopy.

Blood Flow Velocity↗

A new technique to measure and track blood resistivity in intracardiac impedance volumetry.

OBJECTIVE: To propose and verify a technique by which blood resistivity can be measured continuously and instantaneously with a conductance catheter used to measure ventricular volume by intracardiac impedance volumetry. METHODS: Intracardiac impedance volumetry involves the measurement of ventricular blood volume using a multi-electrode conductance catheter. Ventricular volume measurement with the conductance catheter requires the value of blood resistivity. Previously, blood resistivity has been determined by drawing a sample of blood and measuring resistivity in a separate measuring cell. A new technique is proposed that allows the resistivity of blood to be measured with the conductance catheter itself. Two adjacent electrodes of the catheter are chosen to establish a localized electric field. With a localized field, the resistance measured between the adjacent electrodes bears a constant ratio (resistivity ratio) to the resistivity of blood. Finite element cylindrical models with exciting electrodes were created to determine the resistivity ratio. Blood resistivity was determined by dividing the resistance found due to the localized electric field by the resistivity ratio. The proposed scheme was verified in cylindrical physical models and in in vivo canine hearts. RESULTS: Finite element simulations showed the resistivity ratio to be 1.30 and 1.43 for two custom-made catheters (Ohmeda Inc. and Biosensors Inc., respectively). The resistivity ratio remained constant as long as the cylindrical volume of blood around the adjacent electrodes had a radius larger than the electrode spacing. In addition, this ratio was found to be a function of electrode width. The new technique allowed us to measure saline resistivity with an error, -0.99+/-0.25% in a physical model, and blood resistivity with an error, -0.625+/-2.75% in an in vivo canine model. CONCLUSION: The new in vivo technique can be used to measure and track blood resistivity instantaneously and continuously without drawing blood samples.

Animals↗

Hybrid ordered phase encoding (HOPE): an improved approach for respiratory artifact reduction.

Respiration causes continuous change in cardiac position, which leads to image degradation. Phase-encode reordering methods are often used to reduce these artifacts. An improved method for suppressing motion artifacts by reordering the acquisition of k space has been developed that is less sensitive to change of breathing patterns and bulk movement. We describe the theory behind the new approach and compare its results with those of existing methods by use of a phantom with simulated and actual acquired breathing patterns. The comparison was also made in vivo; cardiac scans were performed in 15 subjects with image planes that are known to be particularly susceptible to respiratory artifact. A significant improvement in image quality was achieved compared with conventional nonreordered and existing reordering methods.

Algorithms↗

The interpoint distance distribution as a descriptor of point patterns, with an application to spatial disease clustering.

The topic of this paper is the distribution of the distance between two points distributed independently in space. We illustrate the use of this interpoint distance distribution to describe the characteristics of a set of points within some fixed region. The properties of its sample version, and thus the inference about this function, are discussed both in the discrete and in the continuous setting. We illustrate its use in the detection of spatial clustering by application to a well-known leukaemia data set, and report on the results of a simulation experiment designed to study the power characteristics of the methods within that study region and in an artificial homogenous setting.

Cluster Analysis↗

Combined Monte Carlo and molecular dynamics simulation of fully hydrated dioleyl and palmitoyl-oleyl phosphatidylcholine lipid bilayers.

We have applied a new equilibration procedure for the atomic level simulation of a hydrated lipid bilayer to hydrated bilayers of dioleyl-phosphatidylcholine (DOPC) and palmitoyl-oleyl phosphatidylcholine (POPC). The procedure consists of alternating molecular dynamics trajectory calculations in a constant surface tension and temperature ensemble with configurational bias Monte Carlo moves to different regions of the configuration space of the bilayer in a constant volume and temperature ensemble. The procedure is applied to bilayers of 128 molecules of POPC with 4628 water molecules, and 128 molecules of DOPC with 4825 water molecules. Progress toward equilibration is almost three times as fast in central processing unit (CPU) time compared with a purely molecular dynamics (MD) simulation. Equilibration is complete, as judged by the lack of energy drift in 200-ps runs of continuous MD. After the equilibrium state was reached, as determined by agreement between the simulation volume per lipid molecule with experiment, continuous MD was run in an ensemble in which the lateral area was restrained to fluctuate about a mean value and a pressure of 1 atm applied normal to the bilayer surface. Three separate continuous MD runs, 200 ps in duration each, separated by 10,000 CBMC steps, were carried out for each system. Properties of the systems were calculated and averaged over the three separate runs. Results of the simulations are presented and compared with experimental data and with other recent simulations of POPC and DOPC. Analysis of the hydration environment in the headgroups supports a mechanism by which unsaturation contributes to reduced transition temperatures. In this view, the relatively horizontal orientation of the unsaturated bond increases the area per lipid, resulting in increased water penetration between the headgroups. As a result the headgroup-headgroup interactions are attenuated and shielded, and this contributes to the lowered transition temperature.

Lipid Bilayers↗

Self-similar random field models in discrete space.

Self-similar random fields are of interest in various areas of image processing since they fit certain types of natural patterns and textures. Current treatments of self-similarity in continuous two-dimensional (2-D) space use a definition that is a direct extension of the one-dimensional definition, which requires invariance of the statistics of a random process to time scaling. Current discrete-space 2-D approaches do not consider scaling, but, instead, are based on ad hoc formulations, such as digitizing continuous random fields. In this paper, we show that the current statistical self-similarity definition in continuous space is restrictive and provide an alternative, more general definition. We also provide a formalism for discrete-space statistical self-similarity that relies on a new scaling operator for discrete images. Within the new framework, it is possible to synthesize a wider class of discrete-space self-similar random fields and texture images.

Algorithms↗

The biological clock of Neurospora in a microgravity environment.

The circadian rhythm of conidiation in Neurospora crassa is thought to be an endogenously derived circadian oscillation; however, several investigators have suggested that circadian rhythms may, instead, be driven by some geophysical time cue(s). An experiment was conducted on space shuttle flight STS-9 in order to test this hypothesis; during the first 7-8 cycles in space, there were several minor alterations observed in the conidiation rhythm, including an increase in the period of the oscillation, an increase in the variability of the growth rate and a diminished rhythm amplitude, which eventually damped out in 25% of the flight tubes. On day seven of flight, the tubes were exposed to light while their growth fronts were marked. Some aspect of the marking process reinstated a robust rhythm in all the tubes which continued throughout the remainder of the flight. These results from the last 86 hours of flight demonstrated that the rhythm can persist in space. Since the aberrant rhythmicity occurred prior to the marking procedure, but not after, it was hypothesized that the damping on STS-9 may have resulted from the hypergravity pulse of launch. To test this hypothesis, we conducted investigations into the effects of altered gravitational forces on conidiation. Exposure to hypergravity (via centrifugation), simulated microgravity (via the use of a clinostat) and altered orientations (via alterations in the vector of a 1 g force) were used to examine the effects of gravity upon the circadian rhythm of conidiation.

Biological Clocks↗

The role of target position in smooth pursuit deceleration and termination.

Subjects smoothly pursued a target moving horizontally at 15 deg/s. After pursuit for 1 s, the target jumped 3 deg ahead of the fovea. At the moment of the jump, target velocity became 0 and 'effective visual feedback' assumed a value of either 0 (target retinally stabilized), -0.2, -0.4, or -1.0 (target fixed in space). With 0 visual feedback the eye continued to move smoothly at a moderate velocity, an apparent response to target position relative to the fovea. When negative visual feedback was present eye velocity decreased. With -0.2 and -0.4 feedback, this decrease was not a simple exponential, but often consisted of an initial fast decrease followed by slower decrease. With -1.0 feedback, eye velocity quickly decreased in an approximately exponential manner, and stopped. We were able to simulate these pursuit responses using a simple model of the pursuit system. Key features of the model are: (a) a target-velocity channel whose output decreases with target offset from the fovea, and whose gain switches from high to low as pursuit velocity approaches zero; (b) a target-position channel with a saturation non-linearity at 1-3 deg; and (c) a positive feedback loop with gain of less than 1.0. All of these features are essential to simulate the pursuit responses, especially with visual feedback values of -0.2 and -0.4. Our results and model suggest that target position serves as an important stimulus in guiding smooth pursuit as pursuit velocity decreases, and especially during pursuit termination.

Feedback↗

A unified model of spatial and episodic memory.

Medial temporal lobe structures including the hippocampus are implicated by separate investigations in both episodic memory and spatial function. We show that a single recurrent attractor network can store both the discrete memories that characterize episodic memory and the continuous representations that characterize physical space. Combining both types of representation in a single network is actually necessary if objects and where they are located in space must be stored. We thus show that episodic memory and spatial theories of medial temporal lobe function can be combined in a unified model.

Animals↗

Phase diagrams in the lattice restricted primitive model: from order-disorder to gas-liquid phase transition.

The phase behavior of the lattice restricted primitive model (RPM) for ionic systems with additional short-range nearest neighbor (NN) repulsive interactions has been studied by grand canonical Monte Carlo simulations. We obtain a rich phase behavior as the NN strength is varied. In particular, the phase diagram is very similar to that of the continuum RPM for high NN strength. Specifically, we have found both gas-liquid phase separation, with associated Ising critical point, and a first-order liquid-solid transition. We discuss how the line of continuous order-disorder transitions present for the low NN strength changes into continuum-space behavior as one increases the NN strength and compare our findings with recent theoretical results by Ciach and Stell [Phys. Rev. Lett. 91, 060601 (2003)].

Journal Article↗

Comparative efficacy of cefoperazone, cefoperazone plus sulbactam, ciprofloxacin, clindamycin, metronidazole, and penicillin G against anaerobic bacteria in an animal model.

Treatment efficacy of various antimicrobial regimens against anaerobes was studied in semipermeable chambers simulating a closed-space, locally neutropenic infection site in rabbits. Bacteroides fragilis, Bacteroides melaninogenicus, Clostridium perfringens, and Peptostreptococcus anaerobius were inoculated (at a mean of 5.3 log10 CFU/ml in prereduced pooled rabbit serum) into the chambers (one isolate per chamber) in triplicate. Antimicrobial therapy consisted of cefoperazone, cefoperazone plus sulbactam, ciprofloxacin, clindamycin, metronidazole (against the gram-negative anaerobes), or penicillin G (against the gram-positive anaerobes), beginning 4 hours after organism inoculation and continuing every 6 hours for 16 doses. With the use of anaerobic techniques for specimen acquisition, transport, and culture, quantitative bacterial findings were measured at the start of therapy and at various time points thereafter. Antibiotic concentrations were measured in blood and chamber fluid by liquid chromatography or bioassay methods. At the end of the study in vivo organisms were reduced by at least 3 log10 CFU/ml from drug-free growth control chambers by all the antimicrobial regimens tested except for cefoperazone against B. fragilis and ciprofloxacin against the three isolates tested. The addition of sulbactam to cefoperazone inhibited B. fragilis beta-lactamase activity and eradicated B. fragilis in vivo. In vivo results with this model confirmed in vitro susceptibilities of all tested antimicrobials except ciprofloxacin and should provide useful indications of the potential clinical efficacy of other new agents against anaerobes.

Animals↗

Contributions of space experiments to the study of gravitropism.

The study of gravitropism in space has permitted the discovery that statoliths are not completely free to sediment in the gravisensing cells of roots. These organelles are attached to actin filaments via motor proteins (myosin) which are responsible for their displacement from the distal pole of the cell toward the proximal pole when the seedlings are transferred from a 1g centrifuge in space to microgravity. On the ground, the existence of the link between the statoliths and the actin network could not be established because the gravity force is much greater than the force exerted by the motor proteins. This finding led to a new hypothesis on gravisensing. It has been proposed that statoliths can exert tensions in the actin network which become asymmetrical when the root is stimulated in the horizontal position on the ground. The space experiments have confirmed to some extent the results obtained on gravisensitivity with clinostats, although these devices do not simulate microgravity correctly. Reexamination of the means of estimating gravisensitivity has led to the conclusion that the perception and the transduction phases could be very short (that is, within a second). This data is consistent with the fact that the statoliths are attached to the actin filament and do not have to move a long distance to exert forces on the actin network. It has also been demonstrated that gravity regulates the gravitropic bending in order to avoid the overshooting of the vertical direction on the ground. The roots, which are stimulated and placed in microgravity, are not subjected to this regulation and curve more than roots stimulated continuously. However, the curvature of roots or of coleoptiles that takes place in microgravity can be greatly reduced by straightening the extremity of the organs.

Actins↗

A novel instrument for studying the flow behaviour of erythrocytes through microchannels simulating human blood capillaries.

A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.

Adult↗

Long timestep dynamics of peptides by the dynamics driver approach.

Previous experience with the Langevin/implicit-Euler scheme for dynamics ("LI") on model systems (butane, water) has shown that LI is numerically stable for timesteps in the 5-20 fs range but quenches high-frequency modes. To explore applications to polypeptides, we apply LI to model systems (several dipeptides, a tetrapeptide, and a 13-residue oligoalanine) and also develop a new dynamics driver approach ("DA"). The DA scheme, based on LI, addresses the important issue of proper sampling, which is unlikely to be solved by small-timestep integration methods or implicit methods with intrinsic damping at room temperature, such as LI. Equilibrium averages, time-dependent molecular properties, and sampling trends at room temperature are reported for both LI and DA dynamics simulations, which are then compared to those generated by a standard explicit discretization of the Langevin equation with a 1 fs timestep. We find that LI's quenching effects are severe on both the fast and slow (due to vibrational coupling) frequency modes of all-atom polypeptides and lead to more restricted dynamics at moderate timesteps (40 fs). The DA approach empirically counteracts these damping effects by adding random atomic perturbations to the coordinates at each step (before the minimization of a dynamics function). By restricting the energetic fluctuations and controlling the kinetic energy, we are able with a 60 fs timestep to generate continuous trajectories that sample more of the relevant conformational space and also reproduce reasonably Boltzmann statistics. Although the timescale for transition may be accelerated by the DA approach, the transitional information obtained for the alanine dipeptide and the tetrapeptide is consistent with that obtained by several other theoretical approaches that focus specifically on the determination of pathways. While the trajectory for oligoalanine by the explicit scheme over the nanosecond timeframe remains in the vicinity of the full alpha R-helix starting structure, and a high-temperature (600 degrees K) MD trajectory departs slowly from the alpha helical structure, the DA-generated trajectory for the same CPU time exhibits unfolding and refolding and reveals a range of conformations with an intermediate helix content. Significantly, this range of states is more consistent with spectroscopic experiments on small peptides, as well as the cooperative two-state model for helix-coil transition. The good, near-Boltzmann statistics reported for the smaller systems above, in combination with the interesting oligoalanine results, suggest that DA is a promising tool for efficiently exploring conformational spaces of biomolecules and exploring folding/unfolding processes of polypeptides.

Alanine↗

Conditions for the triggering of spreading depression studied with computer simulations.

In spite of five decades of study, the biophysics of spreading depression (SD) is incompletely understood. Earlier we have modeled seizures and SD, and we have shown that currents through ion channels normally present in neuron membranes can generate SD-like depolarization. In the present study, we define the conditions for triggering SD and the parameters that influence its course in a model of a hippocampal pyramidal cell with more complete representation of ions and channels than the previous version. "Leak" conductances for Na(+), K(+), and Cl(-) and an ion pump were present in the membrane of the entire cell; fast inactivating voltage dependent conductances for sodium and potassium in the soma; "persistent" conductances in soma and apical dendrite, and K(+)- and voltage-dependent N-methyl-D-aspartate (NMDA)-controlled conductance in the apical dendrite. The neuron was surrounded by restricted interstitial space and by a "glia-endothelium" system of extracellular ion regulation bounded by a membrane having leak conductances and an ion pump. Ion fluxes and concentration changes were continuously computed as well as osmotic cell volume changes. As long as reuptake into the neuron and "buffering" by glia kept pace with K(+) released from the neuron, stimulating current applied to the soma evoked repetitive firing that stopped when stimulation ceased. When glial uptake was reduced, K(+) released from neurons could accumulate in the interstitium and keep the neuron depolarized so that strong depolarizing pulses injected into the soma were followed either by afterdischarge or SD. SD-like depolarization was ignited when depolarization spreading into the apical dendrite, activated persistent Na(+) current and NMDA-controlled current. With membrane parameters constant, varying the injected stimulating current influenced SD onset but neither the depolarization nor the increase in extracellular K(+). Glial "leak" conductance influenced SD duration and SD ignition point. Varying maximal conductances (representing channel density) also influenced SD onset time but not the amplitude of the depolarization. Hypoxia was simulated by turning off the Na-K exchange pump, and this resulted in SD-like depolarization. The results confirm that, once ignited, SD runs an all-or-none trajectory, the level of depolarization is governed by feedback involving ion shifts and glutamate acting on ion channels and not by the number of channels open, and SD is ignited if the net persistent membrane current in the apical dendrites turns inward.

Algorithms↗