Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VOC”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Interlaboratory study of a test method measuring total volatile organic compound content of consumer products.

Consumer products are potentially significant sources of volatile organic compounds (VOCs), which are precursors to the formation of ozone in photochemical smog. To address the problem of ozone formation in ambient air, the U.S. Environmental Protection Agency (EPA) has been involved in the development of test methods for measuring the VOC content of consumer products. This paper describes results of an interlaboratory study to estimate the repeatability (precision of analyses performed by a single laboratory) and reproducibility (precision of analyses performed by different laboratories) of the consumer products' VOC measurement method based on EPA Method 24 (for VOCs in surface coatings). The mean method repeatability was 2.7 wt% VOC, and the mean method reproducibility was 4.8 wt% VOC. Method repeatability ranged from 0.2 to 4.4 wt% VOC, and reproducibility ranged from 0.6 to 11.9 weight percent VOC. The precision of the VOC method for consumer products is similar to the precision of EPA Method 24 for surface coatings.

Household Products↗

Wet scrubber analysis of volatile organic compound removal in the rendering industry.

The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture. A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20-100%).

Air Pollutants↗

Proton-transfer-reaction mass spectrometry as a new tool for real time analysis of root-secreted volatile organic compounds in Arabidopsis.

Plant roots release about 5% to 20% of all photosynthetically-fixed carbon, and as a result create a carbon-rich environment for numerous rhizosphere organisms, including plant pathogens and symbiotic microbes. Although some characterization of root exudates has been achieved, especially of secondary metabolites and proteins, much less is known about volatile organic compounds (VOCs) released by roots. In this communication, we describe a novel approach to exploring these rhizosphere VOCs and their induction by biotic stresses. The VOC formation of Arabidopsis roots was analyzed using proton-transfer-reaction mass spectrometry (PTR-MS), a new technology that allows rapid and real time analysis of most biogenic VOCs without preconcentration or chromatography. Our studies revealed that the major VOCs released and identified by both PTR-MS and gas chromatography-mass spectrometry were either simple metabolites, ethanol, acetaldehyde, acetic acid, ethyl acetate, 2-butanone, 2,3,-butanedione, and acetone, or the monoterpene, 1,8-cineole. Some VOCs were found to be produced constitutively regardless of the treatment; other VOCs were induced specifically as a result of different compatible and noncompatible interactions between microbes and insects and Arabidopsis roots. Compatible interactions of Pseudomonas syringae DC3000 and Diuraphis noxia with Arabidopsis roots resulted in the rapid release of 1,8-cineole, a monoterpene that has not been previously reported in Arabidopsis. Mechanical injuries to Arabidopsis roots did not produce 1,8-cineole nor any C6 wound-VOCs; compatible interactions between Arabidopsis roots and Diuraphis noxia did not produce any wound compounds. This suggests that Arabidopsis roots respond to wounding differently from above-ground plant organs. Trials with incompatible interactions did not reveal a set of compounds that was significantly different compared to the noninfected roots. The PTR-MS method may open the way for functional root VOC analysis that will complement genomic investigations in Arabidopsis.

Animals↗

Development of a new photocatalytic oxidation air filter for aircraft cabin.

UNLABELLED: A new photocatalytic oxidation air filter (PCO unit) has been designed for aircraft cabin applications. The PCO unit is designed as a regenerable VOC removal system in order to improve the quality of the recirculated air entering the aircraft cabin. The PCO was designed to be a modular unit, with four UV lamps sandwiched between two interchangeable titanium dioxide coated panels. Performances of the PCO unit has been measured in a single pass mode test rig in order to show the ability of the unit to decrease the amount of VOCs (toluene, ethanol, and acetone) entering it (VOCs are fed separately), and in a multipass mode test rig in order to measure the ability of the unit to clean the air of an experimental room polluted with the same VOCs (fed separately). Triangular cell panels have been chosen instead of the wire mesh panels because they have higher efficiency. The efficiency of the PCO unit depends on the type of VOCs that challenges it, toluene being the most difficult one to oxidise. The efficiency of the PCO unit decreases when the air flow rate increases. The multipass mode test results show that the VOCs are oxidized but additional testing time would be necessary in order to show if they can be fully oxidized. The intermediate reaction products are mainly acetaldehyde and formaldehyde whose amount depends on the challenge VOC. The intermediate reaction products are also oxidized and additional testing time would be necessary in order to show if they can be fully oxidized. The development of this new photocatalytic air filter is still going on. PRACTICAL IMPLICATIONS: The VOC/odor removing adsorbers are available for only a small proportion of aircraft currently in service. The photocatalytic oxidation (PCO) technique has appeared to be a promising solution to odors problems met in aircraft. This article reports the test results of a new photocatalytic oxidation air filter (PCO unit) designed for aircraft cabin applications. The overall efficiency of the PCO unit is function of the compound (toluene, ethanol, and acetone) that challenges the unit and toluene appears to be the most difficult compound to oxidize. Test results have shown the influence of the design of the PCO unit, the air flow rate and the type of UV on the efficiency of the PCO unit. The results obtained in this study represent a first attempt on the way to design a filter for VOC removal in cabin aircraft applications. The PCO technique used by the tested prototype unit is able to partially oxidized the challenge VOCs but one has to be aware that some harmful intermediate reaction products (mainly formaldehyde and acetaldehyde) are produced during the oxidation process before being partially oxidized too.

Air Pollution, Indoor↗

Perturbation of voltage-sensitive Ca2+ channel function by volatile organic solvents.

The mechanisms underlying the acute neurophysiological and behavioral effects of volatile organic compounds (VOCs) remain to be elucidated. However, the function of neuronal ion channels is perturbed by VOCs. The present study examined effects of toluene (TOL), trichloroethylene (TCE), and perchloroethylene (PERC) on whole-cell calcium current (ICa) in nerve growth factor-differentiated pheochromocytoma (PC12) cells. All three VOCs affected ICa in a reversible, concentration-dependent manner. At +10-mV test potentials, VOCs inhibited ICa, whereas at test potentials of -20 and -10 mV, they potentiated it. The order of potency for inhibition (IC50) was PERC (270 microM) > TOL (720 microM) > TCE (1525 microM). VOCs also changed ICa inactivation kinetics from a single- to double-exponential function. Voltage-ramp experiments suggested that VOCs shifted ICa activation in a hyperpolarizing direction; this was confirmed by calculating the half-maximal voltage of activation (V1/2, act) in the absence and presence of VOCs using the Boltzman equation. V(1/2, act) was shifted from approximately -2 mV in control to -11, -12, and -16 mV by TOL, TCE, and PERC, respectively. Similarly, VOCs shifted the half-maximal voltage of steady-state inactivation (V1/2, inact) from approximately -16 mV in control to -32, -35, and -20 mV in the presence of TOL, TCE, and PERC, respectively. Inhibition of ICa by TOL was confirmed in primary cultures of cortical neurons, where 827 microM TOL inhibited current by 61%. These data demonstrate that VOCs perturb voltage-sensitive Ca2+ channel function in neurons, an effect that could contribute to the acute neurotoxicity of these compounds.

Action Potentials↗

The respiratory effects of volatile organic compounds.

Volatile organic compounds (VOCs) have been implicated as causative agents in asthma and building-related illness. To determine whether a mixture of VOCs could impair lung function or cause airway inflammation among subjects without bronchial hyperresponsiveness, the authors conducted a randomized, crossover-design trial of controlled human exposures to filtered air for four hours, VOCs at 25 mg/m(3) for four hours, and VOCs at 50 mg/m(3) for four hours, using a VOC mixture based on sampling of indoor environments. VOC exposures caused dose-related increases in lower respiratory, upper respiratory, and non-respiratory symptoms, with no significant change in lung function (FEV(1);, FVC, or FEF(25-75), nasal lavage cellularity or differential cell counts, induced sputum cellularity or differential cell counts, or biomarkers of airway inflammation, including IL-8, LTB(4), or albumin in nasal lavage or induced sputum samples. Atopic individuals had significantly reduced FEE(25-75 following exposure to VOCs at 50 mg/m(3), suggesting that these individuals may be more sensitive to the health effects of VOCs. The authors conclude that reductions in levels of VOCs to substantially less than 25 mg/m(3) are required if a "non-irritating" work environment is desired.

Adult↗

Health effects of a mixture of indoor air volatile organics, their ozone oxidation products, and stress.

In our present study we tested the health effects among women of controlled exposures to volatile organic compounds (VOCs), with and without ozone (O3), and psychological stress. Each subject was exposed to the following three conditions at 1-week intervals (within-subject factor): VOCs (26 mg/m3), VOCs + O3 (26 mg/m3 + 40 ppb), and ambient air with a 1-min spike of VOCs (2.5 mg/m3). As a between-subjects factor, half the subjects were randomly assigned to perform a stressor. Subjects were 130 healthy women (mean age, 27.2 years; mean education, 15.2 years). Health effects measured before, during, and after each 140-min exposure included symptoms, neurobehavioral performance, salivary cortisol, and lung function. Mixing VOCs with O3 was shown to produce irritating compounds including aldehydes, hydrogen peroxide, organic acids, secondary organic aerosols, and ultrafine particles (particulate matter with aerodynamic diameter < 0.1 microm). Exposure to VOCs with and without O3 did not result in significant subjective or objective health effects. Psychological stress significantly increased salivary cortisol and symptoms of anxiety regardless of exposure condition. Neither lung function nor neurobehavioral performance was compromised by exposure to VOCs or VOCs + O3. Although numerous epidemiologic studies suggest that symptoms are significantly increased among workers in buildings with poor ventilation and mixtures of VOCs, our acute exposure study was not consistent with these epidemiologic findings. Stress appears to be a more significant factor than chemical exposures in affecting some of the health end points measured in our present study.

Adult↗

[Determination of volatile organic compounds in atmospheric environment].

It is well known that volatile organic compounds (VOCs) are the main photochemical pollutants and ozone precursors of the photochemical smog. Investigation of photochemical pollution in the ambient air must focus on VOCs, but the concentration of VOCs in ambient air is in a very low level (10(-9)-10(-12), volume fraction), so there are difficulties in the determination of VOCs. In this work, based on the TO14A and TO15 methods recommended by the Environmental Protection Agency of United States, an improved method for the determination of fifty-six VOCs, mainly O3 precursors, in atmospheric environment was developed. Operating conditions of VOCs preconcentrator, gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) were optimized. Air sample was first frozen by liquid nitrogen, and then H2O and CO2 were eliminated in the VOCs preconcentrator. The preconcentrated VOCs sample was injected to GC and detected by MS or hydrogen flame ionization detector (FID). The C2-C10 hydrocarbons were separated effectively in capillary columns under the high concentration of CO2. The detection limits were 0.1 microgram.m-3 and the relative standard deviations were in the range from 2.57% to 9.82%. This method has been used for the determination of VOCs in real samples. The results were satisfactory.

Air Pollutants↗

Changes in immunological and hematological parameters of female residents exposed to volatile organic compounds in the city of Kaohsiung, Taiwan.

The objective of this study was to assess the effects, if any, of volatile organic compounds (VOCs) in the ambient air of Kaohsiung, Taiwan, on certain hematological and immunological parameters of 153 female study participants. The major source of VOCs was vehicle emissions. The participants were selected from three areas, each area at a different distance from a freeway. Results indicated that total concentrations of VOCs and a subgroup of 25 VOCs (VOC25) ranged from 250 to 335 ppb and 89 to 113 ppb, respectively. The distribution of VOC concentrations did not correlate with distance from the freeway. The participants living in the area with higher VOC concentrations had significantly higher abnormalities of white blood cells (WBC) and hemoglobin (Hb). In addition, IgG and IgA counts were significantly lower for the participants in the area with higher VOCs than for participants in the area with lower VOCs. This finding indicates that VOCs in ambient air may suppress immunological variables.

Adult↗

Volatile organic compound testing of a population living near a hazardous waste site.

Accurate measures of individual exposure are critical in reducing misclassification and establishing scientifically valid associations between health outcomes and exposures to environmental contaminants. As part of a community health study, the Agency for Toxic Substances and Disease Registry conducted exposure testing for volatile organic compounds (VOCs) in the blood of people residing near an industrial complex. The purposes of the study were to assess recent exposures to VOCs in this community and to assess the utility of conducting blood VOC testing on populations near hazardous waste sites. One hundred blood specimens from the target area and 106 blood specimens from the control area were collected for analysis. The blood VOC levels in the target-area participants were compared to those in the control area and to a national reference population. Of the 31 separate VOCs for which testing was done, only acetone was statistically significantly (p < 0.05) higher in target-area participants (1,636 parts per billion [ppb]) than in control-area participants (1,353 ppb). 1,1,1-Trichloroethane was found at higher geometric mean levels in the control group (0.169 ppb) than in the target group (0.115 ppb) (p = 0.01). Median blood levels of 2-butanone and 1,4-dichlorobenzene were slightly higher in both target- and control-area groups than in the national reference population, but neither area was statistically significantly higher than the national reference population for any contaminant measured. Overall, there appeared to be no association between residing in the target area and elevated blood VOC levels. Based on the results of this study, blood VOC testing should be limited to populations living near sites where environmental testing has shown recent, elevated VOC exposure, or where unusual circumstances of illness may be attributed to VOC exposure.

Acetone↗

Method for the collection and assay of volatile organic compounds in breath.

Breath testing for volatile organic compounds (VOCs) provides an intrinsically safe method for investigating human metabolism. An improved breath-collecting apparatus (BCA) is described which was acceptable to patients, simple to use, highly sensitive, and free from chemical contamination. VOCs in 10.0 L alveolar breath and 10.0 L room air were collected onto adsorptive traps. Using automated instrumentation, VOCs were thermally desorbed and assayed by gas chromatography/mass spectroscopy. Twenty normal volunteers were studied, and the alveolar gradient (concentration in breath minus concentration in air) was determined for the most abundant VOCs. A total of 1259 VOCs were observed and tentatively identified in the breath of normal subjects. The mean alveolar gradients were positive in 461 VOCs and negative in 798 VOCs. The method provided a sensitive and convenient assay for breath VOCs and permitted tentative determination of their origin from either inside or outside the body.

Adult↗

Volatile organic compounds in the blood of persons in Kuwait during the oil fires.

Between March and November of 1991, approximately 9000 workers from 43 different countries battled the burning oil wells in Kuwait. To document the exposure of persons in Kuwait during the oil well fires to volatile organic compounds (VOCs), we obtained samples of blood from 14 U.S. personnel in Kuwait City in May of 1991 (group I) and 40 American firefighters working in the oil fields in October of 1991 (group II). Concentrations of VOCs in group I and group II were compared with those of a random sample of 114 persons in the United States (reference group). The median concentrations of VOCs in group I were equal to or lower than those in the reference group. We found significant differences between the median concentrations of several VOCs in group II and the reference group. Median levels of ethylbenzene were about 10 times higher among group II than among the reference group (0.53 microgram/l vs 0.052 microgram/l). Median levels of benzene, m-/p-xylene, o-xylene, styrene, and toluene among group II were more than double those of the reference group. Although firefighters had higher median concentrations of VOCs than the reference group, those American personnel in Kuwait not involved in fighting the oil fires had concentrations of VOCs comparable to those in the reference group. Blood VOC measurements indicate a significant increase in exposure to VOCs in firefighters, but do not demonstrate this in personnel in Kuwait City.

Adult↗

Estimation of biogenic volatile organic compounds emissions in subtropical island--Taiwan.

Elevated tropospheric ozone is harmful to human health and plants. It is formed through the photochemical reactions involving volatile organic compounds (VOCs) and nitrogen oxides (NO(x)). The elevated ozone episodes occur mainly in summer months in the United States, while the high-ozone episodes frequently occur during the fall in Taiwan. The unique landscape of Taiwan produces tremendous amounts of biogenic VOCs in the mountain regions that are adjacent to concentrated urban areas. The urban areas, in turn, generate prodigious amounts of anthropogenic emissions. Biogenic VOC emissions have direct influence on tropospheric ozone formation. To explore the air quality problems in Taiwan, this study attempts to develop a biogenic VOC emission model suitable for air quality applications in Taiwan. The emission model is based on the Biogenic Emissions Inventory System Version 2 and coupled with a detailed Taiwan land use database. The 1999 total Taiwan biogenic VOC emissions were estimated at 214,000 metric tons. The emissions of isoprene, monoterpenes, and other VOCs were about 37.2%, 30.4%, and 32.4% of total biogenic VOC emissions, respectively. The annual total biogenic VOC emission per unit area was more than two times the value of that in any European country, implying that detailed emissions estimates in any size of region will benefit the global biogenic emission inventories.

Air Pollutants↗

Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study.

BACKGROUND: Many volatile organic compounds (VOCs), principally alkanes and benzene derivatives, have been identified in breath from patients with lung cancer. We investigated whether a combination of VOCs could identify such patients. METHODS: We collected breath samples from 108 patients with an abnormal chest radiograph who were scheduled for bronchoscopy. The samples were collected with a portable apparatus, then assayed by gas chromatography and mass spectroscopy. The alveolar gradient of each breath VOC, the difference between the amount in breath and in air, was calculated. Forward stepwise discriminant analysis was used to identify VOCs that discriminated between patients with and without lung cancer. FINDINGS: Lung cancer was confirmed histologically in 60 patients. A combination of 22 breath VOCs, predominantly alkanes, alkane derivatives, and benzene derivatives, discriminated between patients with and without lung cancer, regardless of stage (all p<0.0003). For stage 1 lung cancer, the 22 VOCs had 100% sensitivity and 81.3% specificity. Cross-validation of the combination correctly predicted the diagnosis in 71.7% patients with lung cancer and 66.7% of those without lung cancer. INTERPRETATION: In patients with an abnormal chest radiograph, a combination of 22 VOCs in breath samples distinguished between patients with and without lung cancer. Prospective studies are needed to confirm the usefulness of breath VOCs for detecting lung cancer in the general population.

Aged↗

Volatile organic compounds concentrations in residential indoor and outdoor and its personal exposure in Korea.

To date, personal volatile organic compounds (VOCs) exposure and residential indoor and outdoor VOCs levels have not been characterized in Korea. In this study, residential indoor and outdoor VOCs concentrations were measured and compared simultaneously with the personal exposure for each of 30 participants in a medium city, Asan, and in a metropolitan city, Seoul. Factors that influence personal VOCs exposures were assessed in relation to house characteristics and time activity information. All VOC concentrations were measured using passive samplers during a 24-h period and analyzed using GC-MS. Ten target VOCs were benzene, trichloroethylene, toluene, o-xylene, p-xylene, ethylbenzene, MIBK, n-octane, styrene, and 1,2-dichlorobenzene. Residential indoor and outdoor VOCs concentrations measured in Seoul were significantly higher than those in Asan. Indoor/outdoor (I/O) ratios for all target compounds ranged from 0.94 to 1.51 and I/O ratios of Asan were a little higher than those of Seoul. Results indicate that time activity information can be used to predict personal exposures, although such predictions will result in an over estimation compared to measured exposures. Factors which influence the indoor VOCs level and its personal exposure in relation to house characteristics included house age, indoor smoking, and house type.

Air Pollutants↗

Volatile organic compounds cytotoxicity and expression of HSP72, HSP90 and GRP78 stress proteins in cultured human cells.

The aim of this study was to determine whether overexpression of stress proteins (SPs) could be a sensitive biomarker for cell injury due to exposure to low doses of volatile organic compounds (VOCs) such as benzene, ethylbenzene, toluene, xylene, and chlorinated derivatives (ClB). Sublethal and cytotoxic threshold concentrations of the VOCs were determined by studying the growth rate of normal (fibroblasts) or tumor-derived human cell lines (A549, HepG2) exposed for 4 days to VOCs. Changes in SP expression as a function of concentrations were investigated by Western blotting.VOC toxicity was found to be correlated with their degree of chlorination and their hydrophobicity. Cytotoxic threshold concentrations (no-observed effect concentration, NOEC) were found to be similar for the three cell lines. It was observed that using a mixture of VOCs, each of them at concentration below the NOEC, resulted in an actual toxicity to the cells. This finding reveals a synergistic effect and should be taken into account when assessing threshold risk and exposure limit values in the worker's environment when several pollutants may be present. HSP72 and HSP90 expression levels were not affected whereas GRP78 expression was increased by all the VOCs. Taking into account the specific molecular function of GRP78, it suggests that VOC exposure results in misfolded or underglycosylated protein accumulation in the endoplasmic reticulum. GRP78 overexpression was closely related to the magnitude of growth inhibition due to increasing concentrations of each VOC. The overexpression was found to be significant for concentrations 5 to 30 times higher than NOEC, indicating that, under our experimental conditions, GRP78 expression cannot be considered as a sensitive biomarker of exposure to environmental VOCs.

Benzene↗

Volatile organic compounds in urban rivers and their estuaries in Osaka, Japan.

The levels and distribution of 55 volatile organic compounds (VOCs) were determined by purge and trap GC-MS on water samples from 30 sites within the urban rivers and estuaries of Osaka, a populated industrialized city of Japan. Forty of 55 target VOCs listed in the US EPA Method 524.2 were detected. Dichloromethane (DCM) was found at higher levels at all of the sampling sites. The distribution of dominant VOCs followed four different patterns. First, the most common VOCs (DCM, toluene, trichloroethene and tetrachloroethene) showed concentration maxima in the river segments, and the sites of maximum concentration fluctuated due to irregular large spills and/or loadings. Second, one VOC (cis-1,2-dichloroethene) was evenly distributed in particular rivers due to fixed loadings. Both of these patterns were found in the upper and middle reaches. Third, some of VOCs (1,2,3-trichloropropane and benzene) were specific to a single industrial site and truceable to those sources. Finally, some VOCs showed no concentration maxima along the rivers and entered from multiple sources (chloroform and bromodichloromethane). Diurnal variations of VOCs at the border of the city area, receiving domestic and industrial discharges, provided information to interpret their observed downstream distribution and possible sources.

Journal Article↗

Long-term measurement of volatile organic compounds in ambient air by canister-based one-week sampling method.

A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible.

Air Pollutants↗