Peroxide-modified titanium dioxide: a chemical analog of putative Martian soil oxidants.

Hydrogen peroxide chemisorbed on titanium dioxide (peroxide-modified titanium dioxide) is investigated as a chemical analog to the putative soil oxidants responsible for the chemical reactivity seen in the Viking biology experiments. When peroxide-modified titanium dioxide (anatase) was exposed to a solution similar to the Viking labeled release (LR) experiment organic medium, CO2 gas was released into the sample cell headspace. Storage of these samples at 10 degrees C for 48 hr prior to exposure to organics resulted in a positive response while storage for 7 days did not. In the Viking LR experiment, storage of the Martian surface samples for 2 sols (approximately 49 hr) resulted in a positive response while storage for 141 sols essentially eliminated the initial rapid release of CO2. Heating the peroxide-modified titanium dioxide to 50 degrees C prior to exposure to organics resulted in a negative response. This is similar to, but not identical to, the Viking samples where heating to approximately 46 degrees C diminished the response by 54-80% and heating to 51.5 apparently eliminated the response. When exposed to water vapor, the peroxide-modified titanium dioxide samples release O2 in a manner similar to the release seen in the Viking gas exchange experiment (GEx). Reactivity is retained upon heating at 50 degrees C for three hours, distinguishing this active agent from the one responsible for the release of CO2 from aqueous organics. The release of CO2 by the peroxide-modified titanium dioxide is attributed to the decomposition of organics by outer-sphere peroxide complexes associated with surface hydroxyl groups, while the release of O2 upon humidification is attributed to more stable inner-sphere peroxide complexes associated with Ti4+ cations. Heating the peroxide-modified titanium dioxide to 145 degrees C inhibited the release of O2, while in the Viking experiments heating to this temperature diminished but did not eliminated the response. Although the thermal stability of the titanium-peroxide complexes in this work is lower than the stability seen in the Viking experiments, it is expected that similar types of complexes will form in titanium containing minerals other than anatase and the stability of these complexes will vary with surface hydroxylation and mineralogy.

Carbon Dioxide↗

The effect of titanium surface roughness on the adhesion of monocytes and their secretion of TNF-alpha and PGE2.

Dental implant surfaces are important in determining the tissue/surface interaction. One of the first cells to adhere to the implant surface is the monocyte. This study examines the effect of surface roughness on monocyte adhesion and cytokine secretion. Monocyte adherence to titanium discs of 4 different degrees of surface roughness and plastic surfaces was assayed. Blood mononuclear cells were incubated for 1.5 h in 16 mm culture wells into which titanium discs had been placed. Non-adherent cells were washed off and the numbers of remaining adherent monocyte determined by DNA quantification. TNF-alpha and PGE2 secretion in media from overnight cultures of attached monocytes stimulated with lipopolysaccharide (LPS) was quantified using ELISA and RIA, respectively. Monocyte adherence to rough titanium surfaces was greater than to turned titanium surfaces, while the lowest adherence was to the plastic surface. No significant differences in adherence to 250, 75 or 25 microm blasted surfaces could be detected. The number of adherent monocytes increased with time, with maximum adhesion after 2 h of incubation. Incubation of monocytes adherent to titanium surfaces resulted in a decrease of less than 30% in their numbers over 7 days, whereas cells attached to plastic surfaces decreased to non-detectable numbers after 48 h. Porphyromonas gingivalis LPS stimulation upregulated TNF-alpha and PGE2 secretion into the media. The LPS-induced TNF-alpha and PGE2 secretion was independent of the titanium surface roughness, however the lowest amounts of TNF-alpha and PGE2 were secreted from cells attached to plastic surfaces. The results of this study indicate that the number of monocytes attached to blasted titanium surfaces is significantly greater than to machined titanium surfaces. PGE2 and TNF-alpha secretion is less influenced by titanium surface roughness.

Analysis of Variance↗

Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures.

In a randomized clinical study 47 titanium and gold-alloy fixed partial dentures (FPDs) were placed during a 1-year period. In the titanium group (n = 22) all metal substructures were made of unalloyed titanium. The titanium substructures were fabricated by copy milling, spark erosion and laser welding (Procera, Nobelpharma). Ceramic veneering was carried out with Duceratin titanium ceramics (Ducera, Germany). In the control group (n = 25) the high-gold alloy Degudent U (Degussa, Germany) and Vita VMK 68 ceramics (Vita, Germany) were used. The longest observation time was 6 years. Only one FPD had to be removed due to metal-ceramic failure (titanium group). The clinical performance of all 125 porcelain-fused-to-metal (PFM) veneers with respect to the longevity of the metal-ceramic compound was described by Kaplan-Meyer survivor analyses. Relating survival to a completely intact ceramic veneer, the 5-year survivor rate was 84% for titanium and 98% for the high-gold alloy. PFM titanium restorations exhibited a significantly increased risk of metal-ceramic failure. However, concerning defects requiring removal, no significant differences in titanium versus high-gold alloy occurred. There were no significant differences in the survival distributions between crowns and pontics within the two groups.

Adult↗

Evaluation of titanium brackets for orthodontic treatment: Part II--The active configuration.

After each archwire was ligated into a bracket with a 0.010-in stainless steel wire, both stainless steel and beta-titanium archwires (0.017- x 0.025-in) were slid through commercially pure titanium brackets (0.018-in slot size) at 34 degrees C in both the dry and wet conditions. As controls, stainless steel archwire versus stainless steel bracket couples were used with comparable dimensions. The drawing forces were measured at 5 angulations (0 degrees, 3 degrees, 7 degrees, 9 degrees, and 11 degrees ) for 5 normal forces (nominally 0.2, 0.4, 0.6, 0.8, and 1.0 kg). Regression lines were determined for each frictional couple (P <.05). In the passive configuration, the kinetic frictional coefficients of control and test couples in the dry condition were comparable to previously reported values at 0.11 +/- 0.01 for stainless steel versus stainless steel, 0.12 +/- 0.00 for stainless steel versus titanium, and 0.26 +/- 0.02 for beta-titanium versus titanium. As the angulation was increased from 0 degrees to 11 degrees and the normal force was maintained at 0.2 kg, the resistance to sliding values increased by 208 g for stainless steel versus stainless steel, by 222 g for stainless steel versus titanium, and by 185 g for beta-titanium versus titanium. When the normal force was increased to 1.0 kg, the resistance to sliding values increased to 277 g, 246 g, and 245 g, respectively. Although resistance to sliding increased with angulation and normal force, the passive layer did not breakdown. Titanium brackets remained comparable to stainless steel brackets in the active configuration.

Dental Stress Analysis↗

Inhibition of inflammatory species by titanium surfaces.

Titanium has been used successfully for decades in orthopaedic and dental implants, but the mechanism mediating its biocompatible properties has not been elucidated. The authors investigated the possible role of titanium in modulating reactive oxygen mediators typically produced during the inflammatory response. Peroxynitrite is a highly reactive and unstable inflammatory mediator produced in vivo. This study found a 200% increase in the rate of degradation of peroxynitrite in the presence of titanium. To measure peroxynitrite reactivity, the nitration of 4-hydroxyphenylacetic acid by the peroxynitrite donor 3-morpholinosydnonimine was used. At a pH of 7.4, passivated titanium surfaces led to a 58% decrease of nitration of 4-hydroxyphenylacetic acid by peroxynitrite compared with controls in the absence of proteins. Surface treatments were found to influence the ability of titanium to inhibit peroxynitrite reactivity. Unpassivated titanium surfaces resulted in only a 10% decrease of nitrated 4-hydroxyphenylacetic acid, whereas titanium treated with hydrogen peroxide resulted in a 70% decrease. Decreases in nitration of 4-hydroxyphenylacetic acid also were seen with titanium in the presence of fibrinogen, 10% fetal calf serum, and sodium bicarbonate buffer. These results suggest that titanium is capable of enhancing the breakdown of the inflammatory mediator peroxynitrite and may account for the biocompatible properties of the material.

Biocompatible Materials↗

Consolidation of craniotomy lines after resorbable polylactide and titanium plating: a comparative experimental study in sheep.

The consolidation process of craniotomy lines in a skeletally immature large mammal was studied. A traditional narrow titanium miniplate was compared with a 0.5-mm-thick, 12-mm-wide absorbable punched self-reinforced poly-L-lactide (SR-PLLA) plate, both fixed with titanium miniscrews over bilateral parietal 2.5-mm-wide stable transosseous craniotomies on nine female sheep (16 to 20 months old). After 6, 12, 20, 52, and 104 weeks, cross-sectional histology, histomorphometry, and oxytetracycline chloride fluorescence studies were done to compare the healing process of the craniotomy lines and to study the biocompatibility and the degradation process of the SR-PLLA plate. The consolidation pattern supported the principle of guided tissue regeneration: under the wide, resorbable plate osseous bridging proceeded evenly throughout the line, whereas titanium plating led to bulky, uneven growth in the bone margins. All SR-PLLA-plated osteotomy lines had healed completely by 20 weeks, whereas none of the titanium-plated lines had consolidated during a follow-up of 1 year. The nonossified gaps were filled with dense connective tissue. Histomorphometric analysis showed that osseous bridging proceeded significantly faster on the resorbable plate side compared with the titanium side (p < 0.001). The osteoid surface fraction over the total trabecular surface was highest at 6 weeks, being 63 percent on the SR-PLLA side and only 36 percent on the titanium side. The oxytetracycline chloride fluorescence studies confirmed these findings. After 52 weeks, there was no osteoid or oxytetracycline chloride fluorescence left as a sign of terminated ossification, even in the nonconsolidated titanium sides. Microscopic cracking of the plate was evident at 12 to 20 weeks, and the first signs of active resorption were present at 52 weeks. After 2 years, the plate had disappeared and tiny polylactide particles were being actively reabsorbed. The biocompatibility of SR-PLLA and titanium was good, and no adverse cellular reactions to these materials were noted, except a clinical foreign body reaction caused by loosened titanium miniscrews. A densely punched, 0.5-mm-thick self-reinforced PLLA plate seems to retain its integrity for a sufficiently long time to complete osseous healing of a 2.5-mm-wide craniotomy line in the sheep calvarial area. A thin, wide fixation plate enables superior healing, especially in osseous defects. The degradation process of the SR-PLLA plate begins within 1 year and is far advanced after 2 years. By using absorbable SR-PLLA fixation plates instead of metallic plates, a subsequent operation for the removal of the implants can be avoided. SR-PLLA devices could thus be a potential additive or even alternative to metallic implants in craniofacial surgery.

Animals↗

Effect of heat-treated titanium surfaces on protein adsorption and osteoblast precursor cell initial attachment.

The clinical success of dental implants is governed in part by surface properties of implants and their interactions with the surrounding tissues. The objective of this study was to investigate the effect of heat-treated titanium surfaces on protein adsorption and osteoblast precursor cell attachment in vitro. Passivated titanium samples used in this study were either non heat treated or heat treated at 750 degrees C for 90 minutes. It was observed that the contact angle on heat-treated titanium surfaces was statistically lower compared with the non-heat-treated titanium surfaces. The non-heat-treated titanium surface was also observed to be amorphous oxide, whereas heat treatment of titanium resulted in the conversion of amorphous oxide to crystalline anatase oxide. No significant difference in albumin and fibronectin adsorption was observed between the heat-treated and non-heat-treated titanium surfaces. In addition, no significant difference in initial cell attachment was observed between the two groups. It was concluded that heat treatment of titanium resulted in significantly more hydrophilic surfaces compared to non-heat-treated titanium surfaces. However, differences in oxide crystallinity and wettability were not observed to affect protein adsorption and initial osteoblast precursor cell attachment.

Adsorption↗

The potential for bonding titanium restorations.

PURPOSE: The use of titanium for implants has shown the biological acceptance of the metal. Recently, methods of using titanium for restorations, crowns, and bridges have been introduced using both cast and spark erosion systems for fabrication. A potential also exists for using titanium for bonded (Maryland) bridges. MATERIALS AND METHODS: In this study, the potential for bonding titanium was investigated by cementing with various adhesives: (A) metal to metal, (B) metal to enamel, and (C) comparing with a known procedure of bonding nickel-chromium. Truncated cones of pure titanium were fabricated with a 5-mm circular face for bonding to a larger titanium disc embedded in a plastic ring. A special jig was used to pull the bonded cone from the disc on an Instron tensile testing machine (Instron Corporation, Canton, MA). The resin-metal adhesives used were: (1) Infinity, (2) Metabond, (3) All-Bond 2, and (4) Panavia. These were compared with (5) nickel-chromium cones sandblasted and bonded to nickel-chromium with Panavia. Titanium cones were also bonded to human enamel with (6) Panavia and (7) Metabond. The 10 samples in each group were subjected to tensile force, and point of fracture was recorded. The data were subjected to an analysis of variance with a Scheffe F test at the 95% level of significance. RESULTS: The results of tensile forces in MPa were (1) Infinity, 28.1 +/- 3.6; (2) Metabond, 28.1 +/- 1; (3) All-Bond 2, 49.5 +/- 4.3; (4) Panavia, 57.9 +/- 3.1; (5) Panavia to nickel-chromium, 42.9 +/- 6.6; (6) Panavia to enamel, 18.5 +/- 4.7; and (7) Metabond to enamel, 19.3 +/- 3.5. Titanium was most effectively bonded with All-Bond 2 and Panavia, with Panavia samples significantly better than Panavia to nickel-chromium samples. CONCLUSIONS: It was concluded that titanium bonded restorations with certain adhesive cements were a definite possibility.

Analysis of Variance↗

Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature.

There are very few reports on hypersensitivity reactions in association with titanium-based materials so that the existence of allergy to titanium is still put in question. We report on a patient in whom impaired fracture healing and eczema localized to the perioperative area developed upon titanium-based osteosynthesis. Patch testing gave no reactions to titanium nor to nickel, chromium, or cobalt. However, in the lymphocyte transformation test, the patient's lymphocytes showed markedly enhanced proliferation in vitro to titanium. After removal of the titanium material, fracture healing was achieved and the eczema cleared. Parallel to this, in vitro hyperreactivity to titanium disappeared. Although contact allergic reactions to titanium have been very rarely reported, these findings support a diagnosis of titanium allergy in our patient.

Adult↗

Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial.

BACKGROUND: Stent coating with titanium-nitride-oxide has been shown to reduce neointimal hyperplasia in the porcine restenosis model. We designed a prospective, randomized, clinical study to investigate the safety and efficacy of titanium-nitride-oxide-coated stents compared with stainless steel stents. METHODS AND RESULTS: Ninety-two patients with de novo lesions were randomly assigned to treatment with titanium-nitride-oxide-coated stents (n=45) or stainless steel stents of otherwise identical design (n=47; control). Baseline characteristics were similar in both groups. At 30 days, no stent thromboses or other adverse events had occurred in either group. Quantitative coronary angiography at 6 months revealed lower late loss (0.55+/-0.63 versus 0.90+/-0.76 mm, P=0.03) and percent diameter stenosis (26+/-17% versus 36+/-24%, P=0.04) in lesions treated with titanium-nitride oxide-coated than in control stents. Binary restenosis was reduced from 33% in the control group to 15% in the titanium-nitride oxide-coated stent group (P=0.07). Intravascular ultrasound studies at 6 months showed smaller neointimal volume in titanium-nitride-oxide-coated stents than in control stents (18+/-21 versus 48+/-28 mm3, P<0.0001). Major adverse cardiac events at 6 months were less frequent in titanium-nitride-oxide-coated stents than in control stent-treated patients (7% versus 27%, P=0.02), largely driven by a reduced need for target-lesion revascularization (7% versus 23%, P=0.07). CONCLUSIONS: Revascularization with titanium-nitride-oxide-coated stents is safe and effective in patients with de novo native coronary artery lesions. Titanium-nitride-oxide-coated stents reduce restenosis and major adverse cardiac events compared with stainless steel stents of otherwise identical design.

Aged↗

Fusing of dental ceramics to titanium.

Titanium is known as a useful biometal because of its good biocompatibility and mechanical performance. However, titanium is chemically an exceptional metal, reacting strongly with gaseous elements like oxygen, hydrogen, and nitrogen and also dissolving them extensively. This high reactivity causes problems, for example, when dental ceramics are fused to titanium. Commercial ceramic-titanium systems are increasingly used in prosthetic dentistry, but little is known about the microstructure and composition of the system. Better understanding of chemical reactions between ceramics and titanium is necessary if mechanically more compatible ceramic-titanium bonds are to be developed. This review deals with titanium as a metal, titanium's affinity for nonmetallic elements (especially oxygen), and reactions with other elements. Different aspects are discussed relative to the fusing of dental ceramics to titanium.

Biocompatible Materials↗

Human gingival fibroblast integrin subunit expression on titanium implant surfaces.

BACKGROUND: Implant surface characteristics have been shown to modify cell behavior and regulate integrin expression. Integrin expression and resultant integrin-mediated cellular activity are essential components of tissue healing and homeostasis. Although both osseous and soft tissue healing around dental implants are critical to clinical success, there is limited information available on the effect of implant surfaces on integrin expression in soft tissues. Therefore, the aim of this study was to examine integrin expression for gingival fibroblasts on titanium surfaces and the influence of titanium surface roughness on integrin expression and cell morphology. METHODS: Human gingival fibroblasts were cultured on smooth (polished) and rough (sand-blasted acid-etched) titanium surfaces and a cell culture plastic (control) surface. To analyze integrin expression, total RNA was isolated from experimental and control cells, and levels of integrin subunit mRNA were assessed by reverse transcription-polymerase chain reaction (RT-PCR) using primers specific for the alpha2, alpha4, alpha5, alpha(v), and beta1 integrin subunits and aldolase (internal control). PCR products were analyzed by polyacrylamide gel electrophoresis (PAGE), confirmed via DNA sequencing, and quantified using computer-assisted densitometry. The expression of the integrin subunits was analyzed at the protein level using flow cytometry, as well as fluorescence and confocal laser microscopy. Cell morphology was evaluated using scanning electron microscopy (SEM). RESULTS: Our experiments demonstrated cellular expression of the alpha2, alpha4, alpha5, alpha(v), and beta1 integrin subunits at both mRNA and protein levels on all surfaces. In addition, the alpha4 and beta1 mRNA levels were significantly increased on smooth titanium relative to plastic surfaces (P <.05) with intermediate mRNA levels found on the rough titanium surfaces. The smooth titanium surfaces exhibited a flat monolayer of cells, while rough titanium surfaces showed cells orienting themselves along surface irregularities. CONCLUSIONS: These results demonstrate the presence of multiple integrin subunits in human gingival fibroblasts grown in contact with titanium implant surfaces and that titanium surface roughness alters cellular morphology but appears to have limited effects on integrin expression. This study provides insight into the complicated cellular and molecular events occurring at the implant surface that may be critical to optimizing the soft tissue interactions with the soft tissue-implant interface.

Cell Adhesion↗

Oxidation effects on porcelain-titanium interface reactions and bond strength.

Titanium is strong, resists corrosion and has a low density and excellent biocompatibility. Conventional ceramic-metal restorations have been extensively used in dentistry because of their esthetic appearance and good mechanical properties. This study investigates oxidation effects on the porcelain-titanium interface reactions and bond strength. Pure titanium was treated in a porcelain furnace at temperatures of 600 to 1000 degrees C under either vacuum or air. X-ray diffraction analysis of the surface of pure titanium revealed that the relative peak intensity of alpha-Ti decreased and that of TiO2 increased, with increasing firing temperature. The Vickers hardness number of titanium increased with temperature especially over 900 degrees C, and was harder in air than in vacuum. The tension-shear bond strength of the porcelain-titanium system was the highest in the green stage and lowest after 900 degrees C treatment. Metallographic microscopy of the porcelain-titanium interface revealed a thick band-like zone in the sample treated over 900 degrees C. The excess thick layer of TiO2 apparently weakened the bond strength of porcelain-titanium. Unlike the conventional ceramic-gold alloy system the recommended degassing procedure was not suitable for porcelain-pure titanium restoration.

Adhesiveness↗

[The effect of the mold temperature on the mechanical properties and reaction layer structure of the titanium castings].

Titanium is very reactive at the high temperature, easily oxidized, and reacts with investment components. The mold temperature is an important factor on the quality of the titanium castings. The paper investigated the effect of the mold temperature on the mechanical properties and reaction layer structure of the titanium castings with the tensile test and modern surface analysis technique. The results indicated that the tensile strength and yield strength of titanium castings increased but elongation rate decreased, and the hardness layer become thicker when the mold temperature raised. The hardness layer of titanium castings was 50 microns for the room temperature mold, 125 microns for the 850 degrees C mold. SX-macro electric probe analysis indicated the spreading depth of Zr, Al elements on the surface of titanium castings was not increased when the mold temperature raised, but, the spreading depth of Si element became deeper on the surface of titanium casting, Si layer was about 30 microns for the room temperature mold, 40 microns for the 250 degrees C mold, 50 microns for the 450 degrees C mold, 70 microns for the 650 degrees C mold, 90 microns for the 850 degrees C mold. So, it is necessary to consider the effect of the mold temperature on the qualities of titanium castings when titanium castings for prosthodontics were made in clinic.

Dental Casting Technique↗

[Formation of crystalline calcium phosphate coating on the titanium dioxide layer of dental implants' surface].

Production of octacalcium phosphate crystals on the surface of titanium dioxide particles was achieved at high concentration of titania particles. Optimising the speed of addition of the reagents in the process of crystal growth in heterogeneous nucleation reaction led to reproducible OCP crystal structure on the particle surface. The crystal structure of OCP was investigated by SEM, XRD and FTIR methods. The same crystallization process on the surface of metallic titanium plates did not result in formation of OCP crystals. The evaporated titanium layers on a glass surface and titanium plates without excimer laser treatment did not bond calcium phosphate at any rate. SEM investigations imply that the surface layer of titanium plates changes radically due to laser beam treatment, likely because of oxidation of titanium in the process of evaporation followed by deposition back onto the surface. The calcium phosphate formation on these oxidised titanium plates could be observed by SEM. It can be concluded, that for OCP-formation on titanium metal surface it is necessary to form a thick oxide layer, as the native oxide layer in the case of non-treated titanium substrates did not bound the calcium phosphate, while formation of calcium phosphate could be reached on the laser-treated surface.

Biocompatible Materials↗

[The bonding characteristic of titanium and RG experiment porcelain].

OBJECTIVE: To study the bonding characteristic of Titanium and RG experiment porcelain. METHODS: 5 specimens with a size of 10 mm x 5 mm x 1.4 mm were cast from pure titanium. Then 1 mm of RG experiment opaque and body porcelain were fused on the surface of the titanium specimens. The interface of titanium and porcelain was analyzed with a scanning electron microscope with energy-despersive spectrometry; 6 metal specimens with the size of 25 mm x 3 mm x 0.5 mm were cast from Ni-Cr alloy and a uniform thickness of 1 mm of VMK 99 porcelain was veneered on the central area of 8 mm x 3 mm 18 metal specimens as the same size were cast from pure titanium. The uniform thickness of 1 mm of VITA TITANKERAMIK porcelain, of Noritake super porcelain Ti-22 and of RG experiment porcelain were veneered on every 6 specimens respectively in the central area of 8 mm x 3 mm. The specimens were subjected to a three-point bending test on a load-test machine with a span of 20 mm, then the failure loads were recorded and statistically analysised. The RG porcelain/titanium crown was fabricated by fusing RG opaque porcelain and body porcelain to cast titanium substrate crown. RESULTS: The SEM results show no porosity and crackle were found in the interface. The energy-dispersive spectrometry show that there are Si, Ti and O in the 1 micro m layer between porcelain and titanium, which suggesting titanium and experiment porcelain bonding well. The three point test showed the fracture force for the combinations of titanium/VITA TITANKERAMIK porcelain, titanium/Noritake super porcelain Ti-22 and titanium/RG experiment porcelain were (7.233 +/- 2.539) N, (5.533 +/- 1.199) N and (6.316 +/- 1.433) N respectively. There were not statistically significant differences among them (t test, P < 0.01). The fracture force for the Ni-Cr alloy/VMK99 porcelain combination (12.733 +/- 3.297) N was significantly greater than those of the cast titanium/porcelain (t test, P > 0.05). The crown was translucent with no crack. CONCLUSION: RG porcelain is well compatible with titanium.

Dental Porcelain↗

Functionally gradient bonelike hydroxyapatite coating on a titanium metal substrate created by a discharging method in HBSS without organic molecules.

PURPOSE: This study evaluated the quality of coatings on titanium surfaces prepared by discharging in Hanks' balanced salt solution without organic molecules (HBSS-). MATERIALS AND METHODS: 10 x 10 x 1.0-mm titanium plates were used as cathodes of a coating device developed in the laboratory and immersed in HBSS-. A piece of platinum foil was used as a counterelectrode. Discharging was maintained at 1 A and 10 V (416 mA/cm2) for periods of 90, 270, and 540 seconds. Crystal phases of the coatings were identified by x-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). In addition, the surface characterization and Ca/P atomic ratio of the titanium surfaces were determined by x-ray photoelectron spectroscopy (XPS). Furthermore, the surface topography, the thickness of the coatings, and the bonds between coatings and titanium substrates were observed by scanning electron microscopy. RESULTS: The FTIR and XRD studies demonstrated that the deposits on the titanium after 540 seconds of discharging were crystalline hydroxyapatite. In addition, the thickness of the titanium suboxide layer increased during discharging. The XPS studies indicated that after 540 seconds of processing, the mean Ca/P ratio of the coatings on the titanium was 1.71, which is similar to that of human bone. DISCUSSION: In addition, the replacement of sodium ions with calcium ions seemed important for the promotion of crystallization of the coating. Furthermore, the XPS studies demonstrated that the coatings had a gradient function. Scanning electron microscopy showed that adhesion between coatings and the titanium substrate was close. The coatings were approximately 1 microm thick. CONCLUSION: These findings suggest that a very thin crystalline bonelike hydroxyapatite coating with a gradient function could be prepared on a titanium metal substrate in HBSS- by a discharging method.

Adhesiveness↗

[Modification of titanium surface with calcium and phosphorus ions using micro-arc oxidation and its effect on osteoblast attachment].

OBJECTIVE: To study the method for modifying titanium surface with calcium and phosphorus ions using micro-arc oxidation technique and observe osteoblast attachment to the modified surface. METHODS: TA(2) titanium discs were treated with micro-arc oxidation in electrolyte solution containing Ca(2+) and PO(4)(3-). The influence of Ca(2+) and PO(4)(3-) concentrations in the solution and the electrical parameters of the micro-arc oxidization on the content of calcium and phosphorus ions incorporated into the surface of titanium was investigated using energy-dispersive X-ray (EDX) analysis. Scanning electron microscopy was employed for morphological observation of the ceramic coating on the metal surface. The binding strength of ceramic coating with titanium was tested by shear bonding experiment. MC-3T3-E1 osteoblast-like cells were then cultured on the treated surface of titanium discs to investigate the influence of the ceramic coating on osteoblast attachment. RESULTS: Micro-arc oxidation treatment produced a layer of porous TiO(2) coating on the surface of titanium discs, with the average pore size of 2 to 10 mum. EDX analysis revealed that the ceramic coating contained Ca and P elements, whose content had close correlation with Ca(2+) and PO(4)(3-) concentrations in the electrolyte solution and voltage, duty cycle and frequency of micro-arc oxidation. The average bonding strength of the ceramic coating with titanium was 22+/-3 MPa, and TiO(2) coating promoted attachment and spread of osteoblast-like cells on the metal surface as demonstrated by cell culture. CONCLUSIONS: Porous TiO(2) coating can be constructed on the surface of titanium using micro-arc oxidation, and Ca(2+) and PO(4)(3-) incorporated into the coating can improve the biocompatibility of titanium. The content of Ca(2+) and PO(4)(3-) in the coating can be modulated by adjusting the concentrations of Ca(2+) and PO(4)(3-) in the electrolyte solution and the electrical parameters of the micro-arc oxidation.

3T3 Cells↗