Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes.

Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 degrees C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 degrees C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99mTc-tetrofosmin and 99mTc-furifosmin with material used in our setting does not approach relevant amounts.

Adsorption↗

Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

PURPOSE: To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. METHODS: Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. RESULTS: The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. CONCLUSION: Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

Air Pollution, Indoor↗

Needle exchange decreases the prevalence of HIV-1 proviral DNA in returned syringes in New Haven, Connecticut.

PURPOSE: To report on the deployment of the syringe tracking and testing system in the New Haven needle exchange program, which is the first federally funded evaluation of a needle exchange program conducted in the United States. PATIENTS AND METHODS: A legal needle exchange for intravenous drug users began in New Haven, Connecticut, in November 1990. All syringes distributed by the program received unique tracking codes. Syringes were tracked and HIV-1 proviral DNA prevalence in returned syringes was assessed using polymerase chain reaction and Southern blotting. RESULTS: At the outset of the program, the prevalence of HIV-1 proviral DNA in syringes exceeded two thirds. Prevalence decreased rapidly to less than 45% during the first 3 months of the program and remained at this level for the following 10 months. During the periods of decreasing prevalence and subsequent steady state, no changes in the demographics of program participants or in the drug use habits of newly enrolling clients that could account for the decrease in HIV-1 prevalence in needles were detected. In addition, the program referred almost 20% of its clients to drug treatment programs. CONCLUSION: The needle exchange program in New Haven has decreased the percentage of syringes testing positive for HIV-1 proviral DNA among needle exchange clients while simultaneously serving as an entry point for drug treatment.

Analysis of Variance↗

A comparison of six impression syringes.

Five manually operated, and one air-activated, syringes were evaluated and compared. When used with polyether or polysulfide, some disposable syringes were found to require in excess of 100 pounds of force to operate. The metal reusable syringe required only 13 and 21 pounds, respectively, with the same materials; the air-activated syringe required none. There was no significant difference among the syringes with regard to bubble entrapment during impression making. There was a significant difference found in this regard among the five experienced dentists. The air-activated syringe was most easily controlled, as evidenced by the significantly smaller number of tracing errors made with it.

Air↗

[Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].

UNLABELLED: The infusion of vasoactive drugs in preterm babies using syringe pumps can be complicated by important variations in the infusion rate. AIMS OF THE STUDY: 1) to assess the time between pump start and the actual presence of a substance in the circulation, when using slow rates; 2) to evaluate the effects of changes in the main infusion rate on substance rates infused on the same line. METHODS: We used 10% glucose to mimic vasoactive drugs. The main infusion consisted of saline, and both were infused on the same line using syringe pumps. Glucose concentration was measured at the end of the line. RESULTS: The time between pump start and the actual infusion of glucose depended on syringe volume and on the adjustment of the syringe in the pump. There was a transient increase in glucose rate when the main rate increased, and a transient decrease when the main rate decreased. CONCLUSION: To minimize the time before a substance is actually infused, one should use low volume syringes and correctly adjust the syringe in the pump. Moreover, when a steady infusion rate is necessary, one should avoid variations in the main infusion rate.

Equipment Design↗

Latex allergen levels of injectable collagen stored in syringes with rubber plungers.

OBJECTIVES: To assess the latex allergen content of glutaraldehyde cross-linked injectable bovine collagen stored in rubber plunger syringes. METHODS: Extracts of syringe plungers and collagen solutions before and after storage in syringes with natural rubber latex plungers were tested for latex protein allergens. Thirty-nine patients known to be allergic to latex underwent skin prick testing with extracts of the latex plungers, collagen solutions before and after storage in syringes, standard latex skin test reagents, four extracts from commercially available gloves, and positive (histamine) and negative (diluent) control solutions. Thirty-one control patients not known to be latex allergic were similarly tested. RESULTS: No latex proteins were detected using in vitro immunochemical techniques. Only 1 of 39 (2.5%) latex allergic patients reacted to the syringe extract and the collagen stored in the syringe. No reactions were recorded to collagen that no contact with latex. CONCLUSIONS: The level of latex antigens in injectable collagen is very low. The low prevalence of skin test reactivity in these highly latex allergic individuals suggests that type 1 hypersensitivity reactions as a result of latex contamination would be unlikely.

Allergens↗

Consistency in the amount of linear polymerization shrinkage in syringe-type composites.

OBJECTIVES: The purpose of this study was to investigate whether the composite resin in a syringe showed a consistent shrinkage through its content. Additionally, the amount of linear shrinkage was compared between materials. METHODS: Five brands of syringe-type and one brand of carpule-type composite resins were used in this study. To each brand, two to three syringes were assigned. In the carpule-type composite, 15 carpules were used. The linear polymerization shrinkage was measured using a custom-made linometer. In this linometer, the amount of displacement of an aluminum disk, which was caused by the linear shrinkage of composite resin, was recorded by a computer every second for 90 s. RESULTS: The syringe-type composites showed similar consistencies in the amount of linear shrinkage except one. The linear shrinkage of the carpule-type Tetric Ceram showed more consistency compared with syringe-type composites. The amount of linear polymerization shrinkage varied between materials. SIGNIFICANCE: This investigation demonstrates that the use of carpule-type composites is recommended instead of syringe-types, because of the consistency in its linear shrinkage. The custom-made linometer provides an effective way to study polymerization shrinkage.

Analysis of Variance↗

Safety of reusing disposable plastic insulin syringes.

53 diabetic patients took part in a study to assess the safety of reusing plastic disposable syringes for insulin injection. Each patient used the same plastic syringe for 7 days. The syringe needles were changed when blunt. No patient developed signs of infection at the injection site. Bacteriological assessment of the used syringes and needles showed no contamination in any of the syringes, although one needle was contaminated. The effectiveness of bacteriostatic additives to insulin preparations was demonstrated. The presence of these additives renders safe the practice of a diabetic patient reusing a plastic disposable syringe over a 7-day period.

Adolescent↗

[Potential advantages a new syringe pump system].

OBJECTIVES: To evaluate what could be the benefit in terms of alarm suppression, of a new syringe pumps system, which allows automatic relay without alarms. PATIENTS AND METHODS: We have prospectively recorded the nature and the mode of relay of all syringe pumps for administration of drugs to patients in two ICU. The perfusion regimen was studied in 61 patients over the complete duration of their stay in two ICU. Alarms were also recorded in one ICU room, over 13 days consecutive. The records were processed off-line with an automatic detection-recognition system in order to assess the origin of each alarm. Accordingly, the amount of alarm corresponding to monitor, ventilator and syringe pumps was computed. RESULTS: We found that syringe pumps, which would provide automatic relays without alarm, would suppress 17% of alarms in ICU and automatize 65% of the relay procedures, which are usually performed often in emergency, on response to the end of perfusion alarm. CONCLUSION: New syringe pumps allow both reduction of alarms in ICU and a better management of nurse workload. Indeed syringe relay can be planned in advance.

Equipment Failure↗

Evaluation of the effectiveness of decontamination of dental syringes.

AIM: Steam autoclaving is the gold standard for decontaminating dental instruments, but worldwide disinfection is still widely employed. We have evaluated a range of procedures for their ability to inactivate duck hepatitis B virus contaminating dental syringes. METHODS: Residual infectivity of virus suspensions following 2% glutaraldehyde treatment, ultrasonication or steam sterilisation at 121 degrees or 134 degrees was assayed by injecting day-old ducklings and examining their livers for viral DNA 2.5 weeks later. Dental syringes were contaminated with DHBV positive blood, then treated by the same methods. An anaesthetic cartridge containing water was loaded into the syringe and 400microl aliquots used to inject day-old ducklings. Used dental syringes were examined by Scanning Electron Microscopy. RESULTS: Suspension test:- ultrasonic treatment failed to inactivate DHBV in suspension, but complete inactivation was achieved by 2% glutaraldehyde and autoclaving. Syringe test:- neither ultrasonic treatment nor glutaraldehyde inactivated DHBV. Autoclaving at 134 degrees (3 minutes) permitted transmission to 1/16 ducklings but steam sterilisation at 121 degrees (15 minutes) was effective. Electronmicroscopy demonstrated organic debris (biofilm) in the lumen of used syringes. CONCLUSION: Short autoclaving cycles, albeit at raised temperatures, may fail to inactivate the virus because of poor steam penetration, inadequate heat transfer and the accumulation of protective biofilm.

Animals↗

Start-up delays of infusion syringe pumps.

BACKGROUND: We performed a bench experiment to investigate the extent of start-up delays in fluid delivery for four different syringe pumps after initially placing the infusion syringe in the syringe pump. METHODS: Pump performance was determined at an infusion rate of 1 ml.h-1 with and without a fluid bolus delivered by the infusion pump prior to connecting the infusion line to the simulated patient. RESULTS: The time (mean +/- SD) from starting the pump up to first fluid delivery (t1) differed considerably between pumps (from 6.75 +/- 4.4 to 57.2 +/- 28.6 min) as did the time to steady state fluid delivery (t2) (from 19.6 +/- 9.3 to 76.3 +/- 29.0 min). Applying an initial bolus of 2 ml before connecting the line to the simulated patient practically eliminated the delay in fluid delivery (t1 ranging from 0.3 +/- 0.1 to 1.1 +/- 0.8 min). This manoeuvre also reduced the time to steady flow delivery (t2 from 6.0 +/- 3.1 to 11.1 +/- 4.3 min, P<0.001) and minimized the differences between syringe pumps. CONCLUSIONS: Syringe pump design affects start-up delay times because of free play of the syringe. These delays can be eliminated by a start-up bolus of 2 ml prior to connecting the infusion line to the patient.

Equipment Design↗

Prefilled syringes: safe and effective.

BACKGROUND: Preloaded syringes are time savers, but questions have arisen anecdotally about the risk of infection from this procedure and the possible loss of potency, especially when performed with buffered syringes. OBJECTIVE: To show that preloaded syringes do not develop colonies of bacterial organisms and to confirm that anesthetic potency is maintained for at least 2 weeks. METHODS: Thirty-six syringes were stored for a period of 2 weeks on a shelf in our clinical procedure area with no protection from heat or light. The majority of these were then cultured for bacteria and fungi and one of them was used on one of the authors to determine the potency of the anesthetic. RESULTS: Preloaded syringes do not appear to be prone to the development of bacterial contamination for at least a 2-week period and potency of the anesthetic is maintained. CONCLUSION: Preloaded syringes are time savers and are a safe modality for use in the practicing dermatology office.

Drug Contamination↗

Correlates of unsafe syringe acquisition and disposal among injection drug users in Baltimore, Maryland.

Because multi-person syringe use is the most common vehicle for HIV and hepatitis C virus transmission among injection drug users (IDUs), safe sources of sterile syringes and safe methods of disposal are necessary to curb these epidemics. We examined syringe acquisition and disposal in a cohort of IDUs in Baltimore. Between January 1, 1998 and December 31, 2001, 1034 participants reported on syringe acquisition at 3492 visits, and 953 reported on disposal at 2569 visits. Participants were 69.9% male, 93.9% African-American, and median age was 44. Syringes were acquired exclusively from unsafe sources at 32.3% of visits, while exclusively unsafe disposal was reported at 59.3% of visits. Significant correlates of unsafe acquisition were: attending shooting galleries, anonymous sex, sharing needles, smoking crack, and emergency room visits. Significant correlates of unsafe disposal were: injecting speedball, no methadone treatment, acquiring safely, and frequent injection. Having a primary source of medical care was associated with safe acquisition, but unsafe disposal. IDUs continue to acquire safely but dispose unsafely, especially among those with a primary source of care; this suggests that messages about safe disposal are not being disseminated as widely as those about acquisition. These data suggest the need for a more active program involving pharmacists, an expanded syringe access program, and better efforts to enhance safe disposal.

Adolescent↗

Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients.

We have compared ionized magnesium assays in the Nova 8 electrolyte analyser using dry balanced heparinized syringes and self-prepared heparinized syringes. Thirty blood specimens were obtained into syringes either operator-prepared with liquid sodium heparin or commercially manufactured dry balanced heparinized syringes. There was a good correlation between results from the two syringes. The mean difference between sampling methods was 0.01 mmol litre-1 (95% confidence index -0.05 to 0.08 mmol litre-1). The correlations for sodium, potassium and ionized calcium assays were similarly close. The relationship between sampling methods was close enough to justify the clinical use of self-prepared syringes, with potential economies in clinical costs.

Anticoagulants↗

Hepatitis in used syringes: the limits of sensitivity of techniques to detect hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA, and antibodies to HBV core and HCV antigens.

Hepatitis virus infections are common among injecting drug users. Syringes containing hepatitis B virus (HBV) DNA and hepatitis C virus (HCV) RNA were identified by polymerase chain reaction (PCR); syringes containing antibodies to HBV core antigen and HCV were identified by EIA. Syringe use was simulated to determine the sensitivity of these assays. The mean limits for PCR were 0.082 microliter of blood for HBV and 0.185 microliter for HCV; the mean limits for EIA were 0.185 microliter for HBV and 0.023 microliter for HCV. HBV PCR testing of 681 syringes returned to the needle exchange program in New Haven, Connecticut, revealed a decline from 7.8% HBV-positive at the program's outset to 2.6%. HCV antibodies were found in 12.1% of 207 syringes tested. Syringe testing can help estimate the prevalence and incidence of hepatitis virus infections when standard seroepidemiologic analyses cannot be applied.

Base Sequence↗

Needle-exchange participation, effectiveness, and policy: syringe relay, gender, and the paradox of public health.

Needle-exchange programs (NEPs) have been politically controversial, and most studies have focused on evaluating their effectiveness on human immunodeficiency virus (HIV) transmission rates with little emphasis on the process of how they are used. This article shows that the way intravenous drug users use NEPs may influence their effectiveness. Using data from Baltimore's NEP, participants (N = 2,574) were classified as low, medium, and high users based on the volume, frequency, and duration of contact with the NEP. Higher NEP use was associated with shorter syringe circulation times and less syringe relay, returning syringes to the NEP originally acquired by someone else. For a subsample that was HIV tested (N = 262), syringe relay among women was associated with HIV seroconversion (at a 95% confidence interval). We conclude that exclusive use of the NEP (no relay) provides greater HIV protection than NEP use involving syringe relay. The paradox is that public health goals will not be achieved by prohibiting syringe relay activities and promoting exclusive use. NEPs should broaden their education efforts to have participants understand the value of repeated visits to the NEP.

Adult↗

An external evaluation of a peer-run "unsanctioned" syringe exchange program.

In Vancouver, British Columbia, Canada, difficulty accessing syringes at night has been shown to be strongly associated with human immunodeficiency virus (HIV) risk behavior among the city's injection drug users (IDUs). On September 1, 2001, the Vancouver Area Network of Drug Users (VANDU) initiated an unsanctioned all-night needle-exchange program on a street corner in the heart of the neighborhood where many of the city's IDUs are concentrated. An external evaluation of the population reached by the VANDU exchange was performed through the Vancouver Injection Drug User's Study, a prospective cohort study of IDUs begun in 1996. Persons accessing syringes through the exchange were compared to those active injectors who acquired their syringes from other sources, including the city's fixed site exchange, which closes at 8:00 PM. Overall, 587 active IDUs were seen during the period September 2001 to June 2002; of these individuals, 165 (28.1%) reported using the VANDU exchange. In multivariate analyses, participants who used the VANDU table were more likely to frequently inject cocaine (adjusted odds ratio [AOR]=1.56; 95% confidence interval [CI]=1.00-2.44), inject in public (AOR=2.71; 95% CI=1.62-4.53), and require help injecting (OR=2.13; 95% CI=1.33-3.42). Interestingly, use of the table was also independently associated with safer syringe disposal (AOR=2.69; 95% CI=1.38-5.21). Results indicate that the unsanctioned exchange appears to have reached those IDUs at highest risk of HIV infection. Although the cross-sectional nature of the study design warrants caution, we also found that use of the nighttime exchange was strongly associated with higher rates of safe syringe disposal. The data suggest that drug user organizations can play a major role in reducing harm among their peers by reaching the highest risk drug users with harm reduction services. The findings also suggest that other forms of syringe-exchange programs should consider the benefits of offering fixed site nighttime service.

Adult↗

Stability of Adenoscan (adenosine 3 mg ml-1) in plastic syringes.

Adenosine is an effective and safe agent for myocardial stressing in nuclear medicine. It is commercially available as Adenoscan solution (adenosine 3 mg ml-1) and can be conveniently administered to patients via an anaesthesia syringe pump. The solution is dispensed in plastic syringes prior to administration to the patient. The aim of this study was to assess the stability of Adenoscan in plastic syringes to determine if it is possible to pre-dispense the solution and to store dispensed syringes ready for administration to patients. A 4 week stability analysis using high-performance liquid chromatography was carried out on Adenoscan that had been pre-dispensed into polypropylene syringes and stored at 2-8 degrees C. It was found that the concentration of adenosine in the pre-dispensed syringes remained stable during the 4 week period.

Adenosine↗