Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STEAM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Steam pasteurization of commercially slaughtered beef carcasses: evaluation of bacterial populations at five anatomical locations.

A steam pasteurization process (patent pending) has been shown to effectively reduce pathogenic bacterial populations on beef tissue and to significantly reduce naturally occurring bacterial populations on commercially slaughtered beef carcasses. The objective of this study was to determine the effectiveness of the steam pasteurization treatment for reducing bacterial populations at several anatomical locations on commerically slaughtered carcasses. Before and after pasteurization treatment (82.2 degrees C, 6.5-s exposure time), a sterile sponge was used to sample 300 cm2 at one of five locations (inside round, loin, midline, brisket, or neck). Eighty carcasses (40 before treatment and 40 after treatment) were sampled per anatomical location over 2 processing days. Before treatment, aerobic plate counts (APCs) were found to be highest (P < or = 0.01) at the midline (4.5 log10 CFU/100 cm2), intermediate at the inside round, brisket, and neck (ca. 3.8 log10 CFU/100 cm2), and lowest at the loin (3.4 log10 CFU/100 cm2). After treatment, APCs at all locations were reduced significantly (P < or = 0.01). The inside round, loin, and brisket had the lowest (P < or = 0.01) APCs (ca. 2.6 log10 CFU/100 cm2), whereas the midline and neck had APCs of 3.1 and 3.3 log10 CFU/100 cm2, respectively. The lower reduction in APCs at the neck area indicated that the treatment may not be as effective there, possibly because of the design of the pasteurization equipment. Generic Escherichia coli populations were low at all locations before treatment, with populations on 32% of all carcasses sampled being less than the detection limit of the study (5.0 CFU/100 cm2). After treatment, E. coli populations were significantly lower (P < or = 0.01) than populations before treatment and 85% of all carcasses sampled had E. coli populations below the detection limit. The maximum E. coli population detected after treatment was 25 CFU/100 cm2. For enteric bacterial populations, no differences were observed in the effectiveness of the treatment among the five carcass locations.

Abattoirs↗

A new integrator for monitoring time and temperature of steam sterilizers.

Steam sterilization is the simplest and most useful method of sterilization of thermostable materials. Sterilization depends upon three factors: time, temperature, and the presence of live steam. For the first time an instrument can be employed to monitor these three factors with immediate readout. This paper contrasts the advantages of this integrator with sterilizer controls, and biological and chemical indicators; and describes methods utilized in testing the integrator.

Cross Infection↗

SO2-catalyzed steam explosion of corn fiber for ethanol production.

Corn fiber, a by-product of the corn wet-milling industry, represents a renewable resource that is readily available in significant quantities and could potentially serve as a low-cost feedstock for the production of fuel-grade alcohol. In this study, we used a batch reactor to steam explode corn fiber at various degrees of severity to evaluate the potential of using this feedstock in the bioconversion process. The results indicated that maximum sugar yields (soluble and following enzymatic hydrolysis) were recovered from corn fiber that was pretreated at 190 degrees C for 5 min with 6% SO2. Sequential SO2-catalyzed steam explosion and enzymatic hydrolysis resulted in very high conversion (81%) of all polysaccharides in the corn fiber to monomeric sugars. Subsequently, Saccharomyces cerevisiae was able to convert the resultant corn fiber hydrolysates to ethanol very efficiently, yielding 90-96% of theoretical conversion during the fermentation process.

Animal Feed↗

Evaluating the formulae for integrated lethality in ethylene oxide sterilization using six different endospore forming strains of bacteria, and comparisons of integrated lethality for ethylene oxide and steam systems.

Bacterial endospores from six different species of bacteria were exposed to a spectrum of ethylene oxide (EtO) sterilizing conditions. Temperature was varied from 40 to 60 degrees C and the ethylene oxide concentration was varied from 300 to 750 mg/L. Relative humidity was maintained at 60+/-10% RH. The fraction negative procedure was used to determine the D value for each of the test conditions. Bacterial species tested included Bacillus atrophaeus ATCC # 9372, Bacillus smithii ATCC # 51232, Bacillus subtilis "5230" ATCC # 35021, Bacillus subtilis, DSM # 4181, Bacillus pumilus ATCC # 27142, and Geobacillus stearothermophilus ATCC # 7953. All spore preparations were inoculated on filter paper strips packaged in blue, sterilizable glassine pouches. G. stearothermophilus was the least resistant organism tested. The most resistant organisms tested were B. atrophaeus and B. subtilis "5230". The B. subtilis "5230" strain was slightly more resistant than B. atrophaeus at conditions of 54C and EtO concentrations of 400, 600, and 750 mg/L, as well as at 60C/750mg/L EtO. The other species were between these extremes. This empirical data allowed the application of the recently published formula for converting D values from one set of conditions to another and evaluations of accuracy. The measured D values also allowed the determination of Z values based on temperature variations. These formulae, when applied to process temperatures independent of gas concentration, result in a Z value of approximately 32 degrees C that appears to be similar for all species tested. These data support the application of the previously published formulae 1-6 and allow the same approach to integrated lethality for ethylene oxide processes as is commonly applied to steam sterilization. A review of steam sterilization and related principles was conducted for comparison of integrated lethality for these two methods of sterilization. Errors associated with D values, Z values, extrapolation, and integrated lethality for both methods of sterilization are discussed.

Endospore-Forming Bacteria↗

Effectiveness of steam pasteurization in controlling microbiological hazards of cull cow carcasses in a commercial plant.

The purpose of the study, carried out in a beef processing plant, was to evaluate the effectiveness of a new prototype for steam pasteurization treatment in controlling microbiological hazards. Samples were taken by swabbing randomly selected sites before and after pasteurization and again after chilling to obtain total aerobic counts (TAC), total coliform counts (TCC), and generic Escherichia coli counts (ECC) on Petrifilm plates and to determine the prevalence of Salmonella spp., Listeria monocytogenes, and E. coli O157:H7 using standard enrichment techniques. Escherichia coli and L. monocytogenes strains were tested for various factors associated with their virulence by using colony hybridization and polymerase chain reaction (PCR), respectively. Antimicrobial susceptibility was determined for each isolate that was potentially pathogenic to humans by using the disk-diffusion method. Mean values for TAC, TCC, and ECC were 2.18, 0.16, and 0.06 log10 CFU/cm2, respectively, before pasteurization; 1.17, 0.03, and 0.01 log10 CFU/cm2 after pasteurization; and 0.89, 0.02, and 0.01 log10 CFU/cm2 after chilling. Prevalence of L. monocytogenes, Salmonella spp., and E. coli O157:H7 on carcasses was 0.8%, 0.0%, and 0.0%, respectively, before pasteurization; 2.6%, 0.0%, and 0.0% after pasteurization; and 3.1%, 0.1%, and 0.0% after chilling. The prevalence of E. coli containing > or = 1 virulence gene was 14.7%. More specifically, 11.88% of the isolates obtained before pasteurization, 22.2% obtained after pasteurization, and 31.2% obtained after chilling had virulence genes. All L. monocytogenes isolates tested positive for the presence of 3 major virulence factors (hlyA, inlB, and plcB). Antibiograms showed that certain isolates were susceptible to all antibiotics, some showed an intermediate sensitivity, and others were multiresistant. Overall, these results suggest that steam pasteurization is an effective means of improving safety quality of beef carcasses. However, pasteurization may indirectly contribute to the growth of some pathogenic microorganisms, such as L. monocytogenes.

Abattoirs↗

[A simple apparatus for the determination of the resistance of bioindicators to saturated steam at temperatures less than 100 degrees C., tested with Enterococcus faecium as test microbe].

An apparatus is described by means of which the resistance of microbiological indicators to water vapor at temperatures below 100 degrees C can be determined. The apparatus can be assembled from parts generally available in laboratories. The principle of the apparatus consists in the production of water vapor of the desired temperature under conditions of reduced pressure and its recondensation to water after having passed a special chamber. Accordingly, the device consists of a heated round-bottom flask serving as steam generator, an exposure chamber (B), and a condenser (D) attached to a receiver (E). The bioindicators are exposed to the water vapor in the exposure chamber. A bypass located between the steam generator and the condenser allows for continuous operation even when the exposure chamber is opened. The reduced pressure was achieved by means of a waterjet pump and adjusted by two tandem-joined pressure-regulating valves as needed. The apparatus was tested using water vapor of 73, 75 and 77 degrees C, respectively, and bioindicators containing Enterococcus faecium as test organism. In the range of exposure periods in which bioindicators change from the status "all indicators having surviving test organisms" to the status "all indicators free from surviving test organisms" the bioindicators showed D values of 5.7, 4.4 and 2.9 min, respectively. For the temperature dependence of resistance a z value of 12.5 Kelvin resulted.

Disinfection↗

Sterility assurance based on validation of the sterilization process using steam under pressure. Committee on "Microbial Purity". F.I.P. (International Federation of the Pharmaceutical Industries)

The F.I.P. has long been involved in the practical aspects of microbial quality in pharmaceuticals. This report deals with steam sterilization. A group of European experts from official laboratories and pharmaceutical industries has compiled this text which successively reviews the different pharmacopeias, defines some essential sterilization concepts and parameters, reviews the current approaches to steam sterilization and advises, for each of them, practices in validation and in-process control.

Europe↗

A new vacuum-packaging process for in-hospital steam sterilization.

A new vacuum-packaging system has been developed for in-hospital sterilization of medical supplies and instruments. The system consists of a reusable, impermeable, clear plastic case that automatically seals when the steam sterilization cycle is complete. The outer case of the system seals over the inner basket that holds the medical supplies and instruments. A 2-microns reusable filter is located in the case's pressure release valve. Performance studies found that system heat-up time, holding time, maximum temperature, and cool-down time parameters were equal or superior to those for muslin-wrapped instrument trays used in steam sterilization.

Hospital Departments↗

The potential for use of steam at atmospheric pressure to decontaminate or sterilize parenteral filling lines incorporating barrier isolation technology.

Barrier isolators that enclose aseptic filling equipment are being proposed as a means of: (1) assisting in achieving a 10(-6) sterility assurance level (SAL) in the filling area and (2) minimizing the clean environment required in the manufacturing area. The need for operator and maintenance access to the interior of the barrier isolators presents difficulties in achieving the above goals. Several methods are available for reducing the microbial level inside the isolation barrier. If the objective is the decontamination of all surfaces inside the enclosure, saturated steam at atmospheric pressure can be used. If the objective is to sterilize the inside of the enclosure, saturated steam at atmospheric pressure with added H2O2 can be used. Test data and practical interface considerations relative to various methodologies will be reviewed.

Air Pressure↗

Parameters governing steam sterilization of deadlegs.

Use of saturated steam for sterilization-in-place (SIP) is limited by factors effecting displacement of air from deadlegs. Effects of tube diameter, length, orientation and position within a deadleg were quantitatively studied by examining temperature profiles and rates of kill of Bacillus stearothermophilus spores. Tube diameter had the greatest effect on sterilization. For small diameter tubes, 0.4 cm inside diameter (ID), air displacement was minimal and due mainly to diffusion. 8.8 cm long tubes with 0.4 cm IDs could not be sterilized at 121 degrees C. As tube diameter was increased and buoyant driven convective flow became dominant over viscous forces, sterilization was achieved and tube orientation became critical. Sterilization time, as defined by a twelve log reduction in spore population, was 75 minutes in a 19.0 cm long vertical tube with 1.7 cm ID, whereas 167 minutes were required for an 8.8 cm long tube with 1.0 cm ID. For 8.8 cm long tubes, only the 1.7 cm ID tube could be sterilized when orientated 5 degrees above horizontal. Data show that length to diameter ratios, L/Ds, do not provide a general guideline which can be used to predict sterilization. In the absence of steam bleeders, equipment should be designed to assure strong buoyancy driven convective flow to assure adequate air removal. This requires elimination of small diameter deadlegs (0.4 cm ID and less) and vertical positioning of deadlegs.

Biotechnology↗

[Superheating of germ carriers falsifies the steam resistance of bioindicators].

In the course of experiments on the resistance of bioindicators in saturated steam the authors noticed that carriers made of filter paper showed superheating by hygroscopic condensation. The differences in temperature between the bioindicators and the saturated steam amounted to about 5 Kelvin. Even after 20 minutes temperature equilibrium has not been reached. As a result of overheating and reduced water activity the frequency of bioindicators with surviving test organisms was increased. Beyond that, the microbiologic results depended on storage conditions of the bioindicators before putting them into the resistometer. The lower (higher) the-relative humidity, the higher (lower) the superheating, and the higher (smaller) the frequency of indicators with test organisms having survived. Carriers made of glass fibre fleece did not show any superheating and related effects. But carriers onto which small amounts of a suspension of test organisms in blood have been dried on, gave a superheating of about 1.7 Kelvin. Under identical conditions t50% values of bioindicators made of filter paper and bioindicators made of glass fibre fleece differed considerably. Experiments with Enterococcus faecium as test organism at 75 degrees C resulted in 14.4 and 1.7 minutes, respectively. Therefore, the high resistance of test organisms dried onto filter paper is an artefact caused by superheating. The experimental results should have consequences on the manufacture and use of bioindicators as well as chemoindicators and on the evaluation of results got with them.

Biomarkers↗

[Factors modulating the sensitivity of bacterial spores to steam under pressure].

The sensitivity of spores B. subtilis and B. stearothermophilus to steam under pressure depended on the growth medium and duration of cultivation. B. subtilis and B. stearothermophilus produced the largest number of spores on medium with Mn and yeast extract. However the spores grown on the medium were not the most resistant. The resistant spores was growing up with the age of cultures. The highest level of resistance was obtained in the case of the medium with Ca, after 7-10 days of cultivation. The sporicidal effect of steam under pressure depended on the number of spores on the test.

Bacillus subtilis↗

Reduction of mononuclear cytokine production in hemodialysis patients treated with steam-sterilized low-flux polysulphone membranes.

An increased cytokine production, correlated with long term complications of uremic disease, has been described during hemodialysis. To identify possible differences in the cytokine release of differently sterilized membranes, we enrolled six uremic patients on chronic hemodialysis. The patients underwent dialysis with ETO-sterilized low-flux polysulphone membranes (F6, Fresenius AG) for at least three months (A1), they were then switched to steam-sterilized polysulphone membranes (F6-HPS Fresenius AG) and further evaluations after one (B1) and two months (B2) were carried out. A final evaluation (A2) was made one month after switching back to F6 dialyzers. At each time period, samples were drawn to measure IL-1beta released by cultured mononuclear cells (MN). Moreover, dialysate samples were collected to test endotoxin levels. C3a and C5a levels were assessed at 0, 5, 15 and 60 min from starting hemodialysis. Anti-ETO IgE levels were also assayed at A1, B1 and A2. The LAL test revealed a good quality dialysate. The mean pre-dialysis IL-1beta levels were 215 pg/million cells at A1; falling to 49 at B1, and 54 at B2 (p<0.01); there was then a sharp rebound at A2: 284, p<0.01. Post-dialysis levels followed the same pattern. No correlation between the dialysate endotoxin level and cytokine release was found. Complement activation did not change and in all the phases of the study no anti-ETO IgE was detected in any of the subjects. Our data suggest that the steam sterilized polysulphone membrane induces a lower cytokine release than the ETO sterilized membrane, although the mechanism by which it does so remains to be clarified.

Adult↗

[Treatment of subglottic laryngitis (pseudocroup): steroids instead of steam].

Traditionally, steaming with warm moist air was recommended for the treatment of subglottic laryngitis (pseudocroup). However, no favourable effect has ever been demonstrated. Consequently, steaming is no longer to be advised. Systemic corticosteroids, already of proven effectiveness in severe croup, were shown to be also effective when administered in a single oral dose in moderately severe disease. Besides, in various studies, nebulisation of budesonide (2000 micrograms) with a jet nebuliser had a good effect on the clinical course of croup. However, dose-effect studies are still lacking. A single dose of corticosteroids, either systemic or inhaled via a jet nebuliser, should be the first line therapy in moderate and severe croup syndrome. In milder cases no specific treatment is needed as the disease is self-limiting.

Administration, Inhalation↗

Effects of dry heat and saturated steam on the physical properties of chitosan.

Heat may be employed to facilitate the processing of chitosan and to confer sterility on chitosan-based medical products. In this study, changes were analyzed of the physical properties of purified chitosan heated at 60 to 160 degrees C under specified conditions for periods ranging from 0.5 to 4 h. Two forms of heat were used for processing: dry heat generated by a convection oven and saturated steam generated by an autoclave. Dry heat at < or = 80 degrees C resulted in less rigid chains with lower glass transition temperature, improved aqueous solubility, and slightly higher [eta]. At higher temperatures, dry heat produced chromophores, which may be related to interchain crosslink formation involving the NH2 groups. The [eta] and aqueous solubility of the samples decreased with temperatures > or = 120 degrees C. The coloration of the samples intensified from yellow to brown with increasing temperatures and duration of heat exposure. Chitosan heated at 160 degrees C for > or = 2 h was insoluble in the 0.2 M acetic acid/0.1 M sodium acetate solvent. The rate and extent of the thermal reactions were increased in the presence of saturated steam; the autoclaved samples became insoluble after 2 h of heating at 115 degrees C and after 1 h at > or = 120 degrees C. On the other hand, the physical changes induced by dry heat at < or = 120 degrees C were not affected significantly by heating the chitosan samples under anoxic conditions.

Biocompatible Materials↗

Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.

A subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping is described which, in contrast to echo-planar imaging (EPI), is insensitive to resonance offsets, i.e., tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts. It combines a diffusion-weighted (DW) spin-echo preparation period and a high-speed stimulated echo acquisition mode (STEAM) MRI sequence and yields single-shot images within measuring times of 559 msec (80 echoes). Here, diffusion encoding involved one scan without DW, three DW scans with b = 490 sec mm(-2), and three DW scans with b = 1000 sec mm(-2) (orthogonal gradient orientations). An automated on-line evaluation resulted in isotropic DW images as well as ADC maps (trace of the diffusion tensor). Experiments at 2.0 T covered the brain of healthy subjects in 20 contiguous sections of 6 mm thickness and 2.0 x 2.0 mm(2) in-plane resolution within a total measuring time of 78 sec. High-resolution studies at 1.0 x 1.0 mm(2) (interpolated from 2.0 x 1.0 mm(2) acquisitions) were obtained within 5 min 13 sec using four averages. In comparison with EPI, DW single-shot STEAM MRI exhibits only about half the SNR, but completely avoids regional signal losses, high intensity artifacts, and geometric distortions.

Adult↗

Surface composition of materials used as catalysts for methanol steam reforming: a theoretical study.

PdZn (1:1) alloy is assumed to be the active component of a promising catalyst for methanol steam reforming. Using density functional calculations on periodic supercell slab models, followed by atomistic thermodynamics modeling, we study the chemical composition of the surfaces PdZn(111) and, as a reference, Cu(111) in contact with water and hydrogen at conditions relevant to methanol steam reforming. For the two surfaces, we determine similar maximum adsorption energies for the dissociative adsorption of H(2), O(2), and the molecular adsorption of H(2)O. These reactions are calculated to be exothermic by about -40, -320, and -20 kJ mol(-1), respectively. Using a thermodynamic analysis based on theoretically predicted adsorption energies and vibrational frequencies, we determine the most favorable surface compositions for given pressure windows. However, surface energy plots alone cannot provide quantitative information on individual coverages in a system of coupled adsorption reactions. To overcome this limitation, we employ a kinetic model, from which equilibrium surface coverages of H, O, OH, and H(2)O are derived. We also discuss the sensitivity of our results and the ensuing conclusions with regard to the model surfaces employed and the inaccuracies of our computational method. Our kinetic model predicts surfaces of both materials, PdZn and Cu, to be essentially adsorbate-free already from very low values of the partial pressure of H(2). The model surfaces PdZn(111) and Cu(111) are predicted to be free of water-related adsorbates for a partial H(2) pressure greater than 10(-8) and 10(-5) atm, respectively.

Journal Article↗

Half-Fourier single-shot STEAM MRI.

As a high-speed imaging technique based on stimulated echoes single-shot STEAM MRI is insensitive to chemical shift artifacts and magnetic susceptibility differences. The achievable signal-to-noise ratio (SNR) is limited by the fact that high flip angles of the read-out excitation pulses cause a steep decay of the stimulated echo train and therefore degrade the point-spread function of the resulting image. The present work investigates the use of half-Fourier phase encoding which weakens the flip angle constraint by reducing the number of necessary excitations. Single-shot STEAM MRI of the normal human brain at 2.0 T demonstrates that half-Fourier versions either reduce the measurement time by almost a factor of two without sacrificing the SNR or increase the SNR by about 40% while keeping the measurement time constant.

Brain↗