[Constant volume respirators--constant pressure respirators. Prototypes--advantages and inconveniences].
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Improper design of an injector can cause pulmonary overdistension, fall in venous return, alveolar hypoventilation, insufficient humidification of inhaled gas and oxygen toxicity syndrome during HFJV. Functional characteristics of widely used injectors were determined and their role in the development of serious complications of HFJV is discussed. Special attention is paid to the flow resistance of the injector, its inner volume, ejection ratio, and maximum inspiratory pressure generated by the injector. Practical steps to avoid these complications are recommended.
Employing root-wrenching method and LI-6400-09 soil respiration chamber, this paper measured the diurnal changes of soil respiration rate with and without roots in situ on June 17, August 5, and October 10, 2003. The seasonal changes of soil respiration were also measured from May to September, 2004. The results showed that both the total and the root-wrenched soil respiration appeared single diurnal pattern, with the peaks presented during 12:00-14:00. The diurnal fluctuation of soil respiration on August 5 was smaller than that on June 17 and October 10. There were also obvious seasonal changes in total and root-wrenched soil respiration, as well as in root respiration, which were higher from June to August but lower in May and September. The average total soil respiration, root-wrenched soil respiration, and root respiration were 3.12, 1.94 and 1.18 micromol CO2 x m(-2) s(-1), respectively, and the contribution of roots to total soil respiration ranged from 26.5% to 52.6% from May to September, 2004. There were exponential correlations between respiration rate and soil temperature, and linear correlations between respiration rate and soil humidity. The Q10 values were 2.44, 2.55 and 2.27 for total soil respiration, root-wrenched soil respiration, and root respiration, respectively. The effect of soil temperature on root-wrenched soil respiration was lager than that on total soil respiration and root respiration. Soil humidity had a larger effect on total soil respiration than on root respiration and root-wrenched soil respiration.
In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from an initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects; providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average respirator penetration (primarily due to faceseal leakage) of .04 and 0.3, respectively. The respirator with the highest overall pass rate (95%) reduced M. tb infection risk by 95%, while the respirator with the lowest pass rate (8%) reduced M. tb infection risk by only 70%. To promote the marketing of respirators that will successfully fit the highest proportion of wearers, and to increase protection for workers who might use respirators without the benefit of being fit tested, we recommend that fit testing be part of the NIOSH certification process for negative-pressure air-purifying respirators with tightly fitting facepieces. At a minimum, we recommend that respirator manufacturers generate and provide pass rate data to assist in selecting candidate respirators. In any event, program managers can initially select candidate respirators by comparing quantitative fit tests for a representative sample of their employee population.
Dark respiration in light as well as in dark was estimated for attached leaves of an evergreen (Heteromeles arbutifolia Ait.) and a deciduous (Lepechinia fragans Greene) shrub species using an open gas-exchange system. Dark respiration in light was estimated by the Laisk method. Respiration rates in the dark were always higher than in the light, indicating that light inhibited respiration in both species. The rates of respiration in the dark were higher in the leaves of the deciduous species than in the evergreen species. However, there were no significant differences in respiration rates in light between the species. Thus, the degree of inhibition of respiration by light was greater in the deciduous species (62%) than in the evergreen species (51%). Respiration in both the light and darkness decreased with increasing leaf age. However, because respiration in the light decreased faster with leaf age than respiration in darkness, the degree of inhibition of respiration by light increased with leaf age (from 36% in the youngest leaves to 81% in the mature leaves). This suggests that the rate of dark respiration in the light is related to the rate of biosynthetic processes. Dark respiration in the light decreased with increasing light intensity. Respiration both in the light and in the dark was dependent on leaf temperature. We concluded that respiration in light and respiration in darkness are tightly coupled, with variation in respiration in darkness accounting for more than 60% of the variation in respiration in light. Care must be taken when the relation between respiration in light and respiration in darkness is studied, because the relation varies with species, leaf age, and light intensity.
We measured component and whole-system respiration fluxes in northern hardwood (Acer saccharum Marsh., Tilia americana L., Fraxinus pennsylvanica Marsh.) and aspen (Populus tremuloides Michx.) forest stands in Price County, northern Wisconsin from 1999 through 2002. Measurements of soil, leaf and stem respiration, stem biomass, leaf area and biomass, and vertical profiles of leaf area were combined with biometric measurements to create site-specific respiration models and to estimate component and whole-system respiration fluxes. Hourly estimates of component respiration were based on site measurements of air, soil and stem temperature, leaf mass, sapwood volume and species composition. We also measured whole-system respiration from an above-canopy eddy flux tower. Measured soil respiration rates varied significantly among sites, but not consistently among dominant species (P < 0.05 and P > 0.1). Annual soil respiration ranged from 8.09 to 11.94 Mg C ha(-1) year(-1). Soil respiration varied linearly with temperature (P < 0.05), but not with soil water content (P > 0.1). Stem respiration rates per unit volume and per unit area differed significantly among species (P < 0.05). Stem respiration per unit volume of sapwood was highest in F. pennsylvanica (up to 300 micro mol m(3) s(-1)) and lowest in T. americana (22 micro mol m(3) s(-1)) when measured at peak summer temperatures (27 to 29 degrees C). In northern hardwood stands, south-side stem temperatures were higher and more variable than north-side temperatures during leaf-off periods, but were not different statistically during leaf-on periods. Cumulative annual stem respiration varied by year and species (P < 0.05) and averaged 1.59 Mg C ha(-1) year(-1). Leaf respiration rates varied significantly among species (P < 0.05). Respiration rates per unit leaf mass measured at 30 degrees C were highest for P. tremuloides (38.8 nmol g(-1) s(-1)), lowest for Ulmus rubra Muhlenb. (13.1 nmol g(-1) s(-1)) and intermediate and similar (30.2 nmol g(-1) s(-1)) for T. americana, F. pennsylvanica and Q. rubra. During the growing season, component respiration estimates were dominated by soil respiration, followed by leaf and then stem respiration. Summed component respiration averaged 11.86 Mg C ha(-1) year(-1). We found strong covariance between whole-ecosystem and summed component respiration measurements, but absolute rates and annual sums differed greatly.
The fitting characteristics of particulate respirators are no longer assessed in the National Institute for Occupational Safety and Health respirator certification program. It is important for respirator program administrators to understand the implications of that change and the additional burden it may impose. To address that issue, a typical respirator fit-testing program is analyzed using a mathematical model that describes the effectiveness of a fit-testing program as a function of the fitting characteristics of the respirator and the accuracy of the fittesting method. The model is used to estimate (1) the respirator assignment error, the percentage of respirator wearers mistakenly assigned an ill-fitting respirator; (2) the number of fit-test trials necessary to qualify a group of workers for respirator use; and (3) the number of workers who will fail the fit-test with any candidate respirator model and thereby fail to qualify for respirator use. Using data from previous studies, the model predicts respirator assignment errors ranging from 0 to 20%, depending on the fitting characteristics of the respirator models selected and the fit-testing method used. This analysis indicates that when respirators do not necessarily have good fitting characteristics, respirator program administrators should exercise increased care in the selection of respirator models and increased care in fit-testing. Also presented are ways to assess the fitting characteristics of candidate respirator models by monitoring the first-time fit-testing results. The model demonstrates that significant public health and economic benefits can result when only respirators having good fitting characteristics are purchased and respirators are assigned to workers using highly accurate fit-testing methods.
In this paper, soil respiration chamber, a simple and precise method, was used to measure the stem respiration of trees. LI-6400-09 respiration chamber serving as a system is usually used in soil respiration, but we made polyvinyl chloride (PVC) collar and fixed it on the stem surface to measure the stem respiration. From May to October 2003, the stem respiration of Pinus koraiensis, the dominant tree species in Changbai Mountain, was measured in different time and different places using this technique. Meanwhile, the temperatures in the stems and in the forests were measured. The results showed that the stem respiration rate had a remarkably seasonal tendency with a single peak, the maximum was in August and the minimum was in February. The stem respiration rate had an exponential relationship with stem temperature, and the curve exponential regressions for stem respiration rate and temperature factor of trees with big DBH were better than those with small DBH. The stem respiration in different DBH trees was higher in the south stem face than that in the north stem face, and the variance of respiration rate between south and north decreased with a decrease of DBH trees. During the growing season from May to October, the average maintenance respiration accounted for 63.63% in different DBH trees, and the maintenance respiration contribution to total respiratory consumption increased with increasing DBH, which was 66.76, 73.29% and 50.84%, respectively. The stem respiration Q10 values ranged from 2.56-3.32 in different DBH of trees, and the seasonal tendency for stem R, and Rm in different DBH of trees was obtained by using respiration Q10. Therefore, the differences between different parts of stem and different DBH of trees should be considered in estimating the respiration model in ecosystem.
Respiration and the muscle pump play major roles in increasing venous return. However, the relative contribution of each of these factors remains unclear. The present study investigates the quantitative effects of interaction between respiration and the muscle pump on femoral venous blood flow (FVBF) during a single voluntary knee extension-flexion (KEF) using duplex-Doppler ultrasound. During various respiration modes, which consisted of arrested respiration, normal respiration and deep respiration (inspiration or expiration), eight subjects performed a supine one-legged voluntary KEF. FVBF was measured during respiration only (Protocol A) and during KEF synchronized with respiration (Protocol B). The difference between FVBF values obtained in Protocol B and Protocol A was defined as DeltaFVBF. When KEF was synchronized with normal or deep respiration, FVBF with inspiration was significantly lower than that with expiration. However, DeltaFVBF was significantly higher with inspiration than with expiration during deep respiration but was not significant during normal respiration. Furthermore, DeltaFVBF was significantly higher at both normal and deep respiration than at arrested respiration. The effects upon the venous return during KEF differed between inspiration and expiration. The present findings indicate that during a single supine KEF, respiration might promote venous return to a range of 1.5- to 2.3-fold DeltaFVBF during arrested respiration.
During July 1995 the National Institute for Occupational Safety and Health (NIOSH) began to certify nine new classes of particulate respirators. To determine the level of performance of these respirators, NIOSH researchers conducted a study to (1) measure the simulated workplace performance of 21 N95 respirator models, (2) determine whether fit-testing affected the performance, and (3) investigate the effect of varying fit-test pass/fail criteria on respirator performance. The performance of each respirator model was measured by conducting 100 total penetration tests. The performance of each respirator model was then estimated by determining the 95th percentile of the total penetration through the respirator (i.e., 95% of wearers of that respirator can expect to have a total penetration value below the 95th percentile penetration value). The 95th percentile of total penetrations for each respirator without fit-testing ranged from 6 to 88%. The 95th percentile of total penetrations for all the respirators combined was 33%, which exceeds the amount of total penetration (10%) normally expected of a half-mask respirator. When a surrogate fit test (1% criterion) was applied to the data, the 95th percentile of total penetrations for each respirator decreased to 1 to 16%. The 95th percentile of total penetrations for all the respirators combined was only 4%. Therefore, fit-testing of N95 respirators is necessary to ensure that the user receives the expected level of protection. The study also found that respirator performance was dependent on the value of the pass/fail criterion used in the surrogate fit-test.
Respiration measurements of aerial parts of 18-year-old hinoki cypress (Chamaecyparis obtusa (Sieb. et Zucc.) Endl.) trees were made under field conditions over three years to study changing relationships with tree age between respiration and phytomass, phytomass increment, and leaf mass. The relationship between annual respiration (r(a)) and phytomass (w(T)) was approximated by a proportional function (r(a) = aw(T)), where the proportional constant (a) decreased year by year. The effect of time on the relationship between annual respiration and phytomass of each sample tree was fitted by a power function. Respiration of the tree suppressed by the canopy decreased year by year, but respiration of the other trees increased slightly with age. The relationship between annual respiration and leaf mass was also approximated by a generalized power function. Excluding the suppressed tree, the relationship between annual respiration (r(a)) and the annual increment of aboveground phytomass (Deltaw(T)) was described by a proportional function (r(a) = 2.27Deltaw(T)), where the proportional constant, 2.27, was independent of sample tree and year, indicating that about 2.3 times of the annual aboveground phytomass increment equivalent was respired annually. For any tree, the time constant relationships between annual respiration and leaf mass and phytomass increment for different-sized trees were similar to the corresponding time continuum relationships. In contrast, the time continuum relationship between annual respiration and phytomass differed from the time constant relationship, indicating that respiration of less active woody tissue contributed significantly to aboveground respiration. Based on the relationship between tree size and annual respiration, annual aboveground stand respiration was estimated to be 25.0, 26.9, and 25.8 Mg(dm) ha(-1) year(-1) for the three consecutive years, respectively, and the corresponding aboveground stand biomass was 60.0, 69.0, and 76.8 Mg(dm) ha(-1).