Evaluation of a computerised polysomnography system.

BACKGROUND: Manual analysis of sleep, breathing, and oxygenation records is the "gold standard" for diagnosing sleep abnormalities but is time consuming and cumbersome. The accuracy and cost of a computerised sleep analysis system have therefore been investigated. METHODS: Manual and computerised (CNS Sleep Lab) scores from 43 consecutive clinical sleep studies were prospectively compared for accuracy and the time and costs were recorded. RESULTS: There were good correlations and no systematic differences between manual and computer scoring for total sleep time, sleep onset latency, and duration of REM sleep. There was a small but clinically insignificant systematic difference in breathing pattern analysis, the number of hypopnoeas/hour being lower with manual than with computer scoring (13 (SE 3) v 15 (SE 3)/hour). There was no difference between computer and manual scoring of the frequency of apnoeas, so the frequency of apnoeas + hypopnoeas was clinically insignificantly higher with computer scoring with a highly significant correlation between the two techniques. The time taken to perform the analyses was not different between the two methods (manual 83 (SE 8) v computer 86 (SE 8) minutes). The computer system was six times more expensive than the manual system and annual running costs, including full maintenance contract and 15% depreciation, were twice as great. CONCLUSION: The CNS Sleep Lab is sufficiently accurate for use in clinical sleep studies but is significantly more expensive and does not save technician time.

Costs and Cost Analysis↗

Polysomnography in chronic neuromuscular disease.

BACKGROUND: Sleep is a risk factor for respiratory failure in patients with chronic neuromuscular diseases (NMD). OBJECTIVE: To explore the diagnostic value of monitoring sleep parameters in addition to nocturnal respiratory parameters. METHODS: Thirty-one patients with chronic NMD underwent whole-night polysomnograms including EMG from accessory respiratory muscles. RESULTS: Sleep macrostructure was normal on average. The number of respiratory arousals per hour of sleep was above the upper limit observed in a control group (>2.1) in 71% of the patients, but was moderate in most cases. Nadir oxygen saturation <85% was the most common finding indicating respiratory dysfunction and was present in 80% of the patients. Noninvasive blood gas monitoring identified all but 2 patients with respiratory-induced sleep abnormalities. The respiratory arousal rate was correlated with the oxygen desaturation index, but otherwise there were no significant correlations between sleep and nocturnal respiratory parameters. Vital capacity was significantly positively correlated with obstructive apnea index and daytime base excess to nadir oxygen saturation. Inspiratory activity in accessory respiratory muscles was present during REM sleep and/or slow wave sleep in 70% of the patients. CONCLUSION: The severity of nocturnal respiratory dysfunction is not reflected in the extent of sleep impairment in patients with chronic neuromuscular diseases.

Adult↗

Relationship between the effects of a hypnotic drug, zopiclone, on polysomnography and on daytime EEGs.

The correlation between the effects of zopiclone (ZPC), a nonbenzodiazepine hypnotic drug, on sleep polysomnograms and on daytime EEGs was examined in 12 healthy adult male volunteers. Sleep polysomnograms were recorded after a single oral administration of ZPC 10 mg or placebo according to the double-blind crossover method. Daytime EEGs were recorded after the administration of ZPC, 7.5 mg, or placebo in the same manner, and recorded for 3 min with closed eyes at rest. Then, square roots of the absolute power (amplitude) of the delta-, theta-, alpha-, and beta-activities were calculated from the power spectrum obtained by the fast Fourier transform method. As a result, ZPC decreased the percentage of stage 1 sleep in total sleep time, while it increased the percentage of stage 2, total sleep time, and time of slow wave sleep in the first and second sleep cycles (SWS 1 and 2). Changes in SWS 1 and 2 correlated positively with the amplitude changes in daytime resting delta-activity. This indicates that the increase of SWS due to ZPC could be related to the change of delta-activity in the daytime resting EEG.

Adult↗

The snoring spectrum: acoustic assessment of snoring sound intensity in 1,139 individuals undergoing polysomnography.

STUDY OBJECTIVES: To quantify the snoring sound intensity levels generated by individuals during polysomnographic testing and to examine the relationships between acoustic, polysomnographic, and clinical variables. DESIGN: The prospective acquisition of acoustic and polysomnographic data with a retrospective medical chart review. SETTING: A sleep laboratory at a primary care hospital. PARTICIPANTS: All 1,139 of the patients referred to the sleep laboratory for polysomnographic testing from 1980 to 1994. INTERVENTIONS: The acoustic measurement of snoring sound intensity during sleep concurrent with polysomnographic testing. MEASUREMENTS AND RESULTS: Four decibel levels were derived from snoring sound intensity recordings. L1, L5, and L10 are measures of the sound pressure measurement in decibels employing the A-weighting network that yields the response of the human ear exceeded, respectively, for 1, 5, and 10% of the test period. The Leq is a measure of the A-weighted average intensity of a fluctuating acoustic signal over the total test period. L10 levels above 55 dBA were exceeded by 12.3% of the patients. The average levels of snoring sound intensity were significantly higher for men than for women. The levels of snoring sound intensity were associated significantly with the following: polysomnographic testing results, including the respiratory disturbance index (RDI), sleep latency, and the percentage of slow-wave sleep; demographic factors, including gender and body mass; and clinical factors, including snoring history, hypersomnolence, and breathing stoppage. Men with a body mass index of > 30 and an average snoring sound intensity of > 38 dBA were 4.1 times more likely to have an RDI of > 10. CONCLUSIONS: Snoring sound intensity levels are related to a number of demographic, clinical, and polysomnographic test results. Snoring sound intensity is closely related to apnea/hypopnea during sleep. The noise generated by snoring can disturb or disrupt a snorer's sleep, as well as the sleep of a bed partner.

Adult↗

Comparison of AutoSet and polysomnography for the detection of apnea-hypopnea events.

The use of the flow vs time relationship obtained with the nasal prongs of the AutoSettrade mark (AS) system (diagnosis mode) has been proposed to detect apneas and hypopneas in patients with reasonable nasal patency. Our aim was to compare the accuracy of AS to that of a computerized polysomnographic (PSG) system. The study was conducted on 56 individuals (45 men) with clinical characteristics of obstructive sleep apnea (OSA). Their mean (+/- SD) age was 44.6 +/- 12 years and their body mass index was 31.3 +/- 7 kg/m2. Data were submitted to parametric analysis to determine the agreement between methods and the intraclass correlation coefficient was calculated. The Student t-test and Bland and Altman plots were also used. Twelve patients had an apnea-hypopnea index (AHI) <10 in bed and 20 had values >40. The mean (+/- SD) AHI PSG index of 37.6 (28.8) was significantly lower (P = 0.0003) than AHI AS (41.8 (25. 3)), but there was a high intraclass correlation coefficient (0.93), with 0.016 variance. For a threshold of AHI of 20, AS showed 73.0% accuracy, 97% sensitivity and 60% specificity, with positive and negative predictive values of 78% and 93%, respectively. Sensitivity, specificity and negative predictive values increased in parallel to the increase in AHI threshold for detecting OSA. However, when the differences of AHI PSG-AS were plotted against their means, the limits of agreement between the methods (95% of the differences) were +13 and -22, showing the discrepancy between the AHI values obtained with PSG and AS. Finally, cubic regression analysis was used to better predict the result of AHI PSG as a function of the method proposed, i.e., AHI AS. We conclude that, despite these differences, AHI measured by AutoSettrade mark can be useful for the assessment of patients with high pre-test clinical probability of OSA, for whom standard PSG is not possible as an initial step in diagnosis.

Adolescent↗