Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MONITORING SYSTEMS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

[Improvements in alarm care speed for the clinical monitor system].

Hypoxia often occurs in the course of emergency treatment the monitoring systems alarm is not heard promptly by the nurses in attendance. In this study, nurses were monitored for the speed of their reactions to such alarms in 326 clinical instances. In 128 instances (39 percent) the nurses reacted immediately (within ten seconds), and in 198 instances (61 percent) the nurses took more than ten seconds to react. In relation to the reactions that took longer than ten seconds, it was discovered that there was: a lack of alertness about dealing with alarms, insufficient knowledge about setting alarms, no coordinated response mechanism, a failure to hear the alarm, limitations affecting the equipment and difficulty detecting the direction of origin of the alarm sound. For these reasons the hospital implemented briefings about alarms during morning meetings, a coordinated response mechanism, improvements in standards concerning the setting and inspection of alarms, the setting of limits on the frequency of patient's visits and the numbers of visitors, and the setting of a standard alarm volume level. As a result, the percentage of nurses responding to alarms within ten seconds increased to eighty percent, raising standards of nursing care, medical treatment and patient safety.

Equipment Failure↗

A rapid monitoring system of human herpesviruses reactivation by LightCycler in stem cell transplantation.

To establish a practical monitoring system of human herpesviruses reactivation in patients undergoing stem cell transplantation, we developed a new, very rapid, highly sensitive, and quantitative PCR assay for accurate measurement of human cytomegalovirus (CMV), human herpesvirus 6 (HHV-6) and Epstein-Barr virus (EBV) DNA using LightCycler. The LightCycler system revealed that there was a linear correlation in the wide range of viral template DNA at the indicated number of PCR cycles. Peripheral blood cells were collected from 16 patients undergoing stem cell transplantation. The cut-off level of CMV and HHV-6 was assessed as 10(2) copies/microg and that of EBV as 10(3). High numbers of CMV genomes were detected in 3/13 patients after transplant, and reactivation of HHV-6 was frequently seen, whereas none of the patient showed an elevation of EBV genome copies until the end of the observation period. In the present study, the reactivation of beta herpesviruses is associated with the occurrence of thrombotic microangiopathy (TMA) in two patients undergoing allogeneic BMT. Therefore, it may contribute in clarifying the pathological potential of human herpesviruses using a large number of clinical samples. Our results suggest that this system may be useful for monitoring viral reactivation.

Adolescent↗

Ward and laboratory assessment of two second-generation blood-glucose monitoring systems.

We present an assessment of two blood-glucose monitoring systems--the Ames Glucostix reagent strips read on the Glucometer II and the Boehringer-Mannheim BM-Test-Glycemie 20-800 test strips read on the Reflolux II meter. Many nurses in the wards and a technologist in the laboratory assessed the systems. All operators achieved good precision with both systems at various glucose levels, the coefficients of variation for the technologist being less than 8% and those for the nurses being less than 11%. The Boehringer-Mannheim system gave good agreement with the laboratory values, with a mean bias of +0.14 mmol/L and limits of agreement between -1.38 mmol/L and +1.66 mmol/L. The Ames system gave poorer agreement, with a bias of +0.80 mmol/L and limits of agreement between -2.12 mmol/L and +3.72 mmol/L. Our study shows that both systems are capable of providing clinically-acceptable results when used by trained personnel. Although it took longer to use, the operators unanimously preferred the Boehringer-Mannheim system because generally it was easier to handle. This is due to a smaller amount of blood being needed which is easier to apply and to remove from the strip, and the cleaning material is not as likely to be left on the strip. Also, strip insertion is easier and there is sufficient time for this after the removal of blood.

Blood Glucose↗

[Development of the IMP900 ECG & VT patient monitoring system].

A new respiration monitor was developed with this paper, which can monitor tidal volume continuously based on the impedance technique as well ad ECG at the same time. Advanced digital storage display technique and modular hardware design are adopted in this system. One by one calibration method was introduced to solve problem of individual differences in the measurement of tidal volume, which make it viable to monitor Tidal volume with impedance technique. The system possesses characteristic of high ratio of performance to cost. Clinical tests of the system have been made for nonsurgical patients, the results show that the system meets the basic clinical requirements, and its wide clinical applications are expected in the future.

Electrocardiography↗

Accumulation of radionuclides by plants as a monitor system.

The accumulation of radionuclides by plants acting as a monitoring system in the environment may occur by two modes; foliar absorption by the leaves and shoot of the plant, or by root uptake from the soil. Data on plant accumulation of radionuclides may be obtained from studies of fission product radionuclides deposited as worldwide fallout, and from tracer studies of plant physiology. The epidermal features of plant foliage may exert an effect upon particle retention by leaves, and subsequent uptake of radionuclides from the surface. The transport of radionuclides across the cuticle and epidermis of plant leaves is determined in part by the anatomy of the leaf, and by physiological factors. The foliar uptake of fallout radionuclides, 99Sr, 131I, and 137Cs, is described with examples from the scientific literature. The environmental half-life of 131I, for example, is considerably shorter than its physical half-life because of physical and biological factors which may produce a half-life as short as 0.23/day. 99Sr and 137Cs are readily taken up by the leaf, but 137Cs undergoes more translocation into fruit and seeds than 99Sr which tends to remain in the plant part in which it was initially absorbed. Soil-root uptake is conditioned primarily by soil chemical and physical factors which may selectively retain a radionuclide, such as 137Cs. The presence of organic matter, inorganic colloids (clay), and competing elements will strongly affect the uptake of 99Sr and 137Cs by plants from the soil. The role of plants as monitors of radionuclides is twofold: as monitors of recent atmospheric releases of radionuclides; and as indicators of the long-term behavior of aged deposits of radionuclides in the soil.

Absorption↗

Large-scale screening of Arabidopsis circadian clock mutants by a high-throughput real-time bioluminescence monitoring system.

Using a high-throughput real-time bioluminescence monitoring system, we screened large numbers of Arabidopsis thaliana mutants for extensively altered circadian rhythms. We constructed reporter genes by fusing a promoter of an Arabidopsis flowering-time gene - either GIGANTEA (GI) or FLOWERING LOCUS T (FT) - to a modified firefly luciferase gene (LUC(+)), and we transferred the fusion gene (P(GI)::LUC(+) or P(FT)::LUC(+)) into the Arabidopsis genome. After mutagenesis with ethyl methanesulfonate, 50 000 M(2) seedlings carrying the P(GI)::LUC(+) and 50 000 carrying P(FT)::LUC(+) were screened their bioluminescence rhythms. We isolated six arrhythmic (AR) mutants and 29 other mutants that showed more than 3 h difference in the period length or phase of rhythms compared with the wild-type strains. The shortest period length was 16 h, the longest 27 h. Five of the six AR mutants carrying P(GI)::LUC(+) showed arrhythmia in bioluminescence rhythms in both constant light and constant dark. These five AR mutants also showed arrhythmia in leaf movement rhythms in constant light. Genetic analysis revealed that each of the five AR mutants carried a recessive mutation in a nuclear gene and the mutations belonged to three complementation groups, and at least one of which was mapped on a novel locus. Our results suggest that the three loci identified here may contain central clock or clock-related genes, at least one of which may be a novel.

Arabidopsis↗

An automatic monitoring system for measuring handwashing frequency in hospital wards.

A handwash monitoring system is described which enables accurate measurements to be taken of the frequency of handwashing by nursing and medical staff during the course of their duties. Preliminary studies have demonstrated it can record handwashing frequency with 93 per cent accuracy and, during preliminary ward trials, the measured handwashing frequency was 5-10 washes per nurse per shift. This was far less than the nurses' claimed handwashing frequency.

Cross Infection↗

The Michigan equine monitoring system. I. Design, implementation and population estimates.

The Michigan equine monitoring system (MEMS) was designed and implemented in the State of Michigan, starting in 1991. The program was designed systematically to track the State's equine population, its health, and its economic implications to the equine industry. The MEMS was designed as a two-phase program. Phase I (the population and economic survey; the subject of this paper) was designed to provide new and statistically valid information describing the size, composition, location and economic characteristics of the Michigan equine industry. A standardized questionnaire was used to collect data via mail, telephone and personal interviews. Of the 3000 randomly selected list-frame samples, 2800 (93%) participated. However, 650 of these had no equids. There were 129,932 equids reported compared with 160,000 in 1984. The American Quarter Horse, Standardbred and Arabian breeds were the most numerous. Detailed results, including the size of equine operations/herds, uses, geographical distribution and the financial structure of the industry, are presented. A detailed account of the strategies used in designing and implementing the system is provided.

Animal Husbandry↗

Assessment of adherence to antiviral therapy in HIV-infected children using the Medication Event Monitoring System, pharmacy refill, provider assessment, caregiver self-report, and appointment keeping.

The authors sought to assess the utility of the electronic Medication Event Monitoring System (MEMS) in monitoring adherence to highly active antiretroviral therapy (HAART) in HIV-infected children and to compare this with other methods of adherence assessment. Twenty-six perinatally HIV-infected children being treated with three or more antiretroviral medications and their caregivers were enrolled and prospectively followed-up for 6 months. Adherence was assessed using MEMS monitoring of one antiretroviral, pharmacy refill records of all antiretrovirals, a caregiver self-report interview, a physician/nurse questionnaire, and appointment-keeping behavior. Viral loads measured at the end of the 6-month period were compared with the various adherence assessment methods. Adherence rates for the MEMS-monitored medication ranged from 12.7% to 97.9% (median = 81.4%), and 11 of the participants (42%) had less than 80% adherence using this method. A MEMS adherence rate greater than 80% was associated with viral load below the threshold of detection 6 months after enrollment (p <.001). Although not as robust, pharmacy refill rates for all antiretroviral medications were also associated with virologic response. The highest specificity was attained when both MEMS and pharmacy refill were used in combination. Physician assessment of adherence rate as well as appointment-keeping behavior was associated with virologic response, whereas caregiver self-report was not.

Adult↗

Antibiotic resistance of staphylococci from humans, food and different animal species according to data of the Hungarian resistance monitoring system in 2001.

Based on data of the Hungarian resistance monitoring system the antibiotic resistance of Staphylococcus strains of human and animal origin was studied. No methicillin-resistant staphylococci harbouring mecA gene were isolated from animals in 2001. Penicillin resistance, mediated by penicillinase production, was the most frequent among Staphylococcus aureus strains isolated from humans (96%), from bovine mastitis (55%), from foods (45%) and from dogs. In staphylococci isolated from animals low resistance percentages to aminoglycosides (0-2%), fluoroquinolones (0.5-3%) and sulphonamides (0.5-4%) were found but in strains isolated humans these figures were higher (1-14%, 5-18% and 3-31%, respectively). The most frequent antibiotic resistance profiles of strains isolated from animals and food were penicillin/tetracycline, penicillin/lincomycin and penicillin/lincomycin/tetracycline. Penicillin/tetracycline resistance was exhibited by strains from mastitis (3), samples from the meat industry (31), poultry flocks (1), poultry industry (1), noodle (1) and horses (2). Penicillin/lincomycin resistance was found in 10 Staphylococcus strains from mastitis, 1 from the dairy industry, 1 from the meat industry and 6 from dogs. Isolates from mastitis (2), from the dairy industry (2), from pigs (1), from the meat industry (1) and from poultry (1) harboured penicillin/lincomycin/tetracycline resistance pattern. Multiresistant strains were usually isolated only from one and sometimes from two animal species; therefore, the spread of defined resistant strains (clones) among different animal species could not be demonstrated. These results also suggest that the transfer of antibiotic resistance of S. aureus from animals to humans probably occurs less frequently than is generally assumed.

Animals↗

Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: spinning with a continuous glucose monitoring system.

BACKGROUND: Hypoglycemia is the most common and serious side effect of insulin therapy in type 1 diabetes (T1DM), frequently occurring both during and after vigorous exercise. Late-onset hypoglycemia (LOH) is of great concern, occurring 1-36 h after exercise, often going unnoticed during sleep. Repeated exposure to LOH causes autonomic glucose counterregulatory failure and sometimes coma and death. Continuous glucose monitoring systems have recently emerged as a potentially important tool in diabetes management, allowing individuals to track glucose levels continuously and learn how various behaviors influence glucose control. METHODS: In this pilot study, we determined the efficacy of using a real-time continuous glucose monitoring system (Guardian RT, Minimed, Northridge, CA) to detect blood glucose excursions associated with exercise and LOH (i.e., blood glucose concentration <4 mM) after exercise in individuals with T1DM. Five subjects with T1DM were monitored before, during, and after a 60 min vigorous spin class using Guardian RT (48 h in total). RESULTS: Following the exercise, three of the five subjects had LOH, while the other two experienced decreases in blood glucose concentrations to 4 mM. The Guardian RT monitor was effective in notifying all of the subjects of such glycemic excursions over the 48 h surveillance period. A strong correlation (r = 0.89, P < 0.001) was found between conventional self-monitoring of blood glucose and Guardian RT data pairs. CONCLUSION: These limited data suggest that nocturnal LOH occurs commonly following vigorous exercise and that a Guardian RT is a useful and important diagnostic tool. Further study into clinical strategies for preventing hypoglycemia associated with this common form of mixed aerobic and anaerobic exercise is urgently needed through insulin modification and carbohydrate supplementation.

Adult↗

A newly developed on-line monitoring system for the determination of serum electrolytes and urea during hemodialysis.

Continuous monitoring of serum solute concentrations throughout a dialysis session could be beneficial for the prevention of intradialytic morbidity such as hypotension and for the confirmation of dialysis adequacy. In this paper, we introduce a new on-line monitoring system for use during hemodialysis sessions, a system developed for the continuous observation of serum biochemical data. Using this system, we also show the possibility of clinical applications. Intradialytic hypotension could be prevented by the observation of filtrate sodium concentration and the control of dialysate sodium concentration. The termination of a dialysis session could be decided by the observation of the filtrate urea nitrogen, on the basis of the Kt/V urea ratio. Because monitoring for other solutes such as calcium and creatinine is theoretically available, clinical applications will continue to increase in the future.

Adult↗

The National Animal Health Monitoring System. A source of on-farm information.

The National Animal Health Monitoring System is a program of the USDA:APHIS:Veterinary Services designed to collect, analyze, interpret, and disseminate data on the management and health of US livestock, poultry, and aquaculture populations. The system is comprised of a national program staff, the National Veterinary Services Laboratories, and a field component that includes state and federal animal health officials distributed throughout the United States. The system uses a variety of approaches (large national studies, on-going monitoring, and target short-term studies) to address high priority objectives for US animal agriculture defined through a far-reaching information-needs assessment process.

Animals↗

Portable sick house syndrome gas monitoring system based on novel colorimetric reagents for the highly selective and sensitive detection of formaldehyde.

Formaldehyde (HCHO) emitted from the furniture and the walls in the rooms injures the eyes, nose, and respiratory organs and causes allergies, which is called sick house syndrome. We designed and synthesized novel colorimetric HCHO-sensing molecules (KD-XA01 and KD-XA02) which possess an enaminone structure and developed a hand-held instrument to monitor indoor HCHO gas with the use of KD-XA01. These sensing molecules produced speedy color changes from colorless to yellow under mild conditions, which was caused by the fact that the enaminone structure in the reagent reacts with HCHO to give a lutidine derivative. This reaction took place not only in the solution phase but also in the solid phase (surface of the cellulose paper). To take advantage of this phenomena, a handy and rapid monitoring system has been developed for detecting indoor HCHO gas using a highly sensitive and selective detection tablet constructed from the porous cellulose paper that contains silica gel as an adsorbent, KD-XA01, and phosphoric acid under optimum conditions. This instrument detected the surface color change of the tablet from white to yellow, which was monitored as a function of the intensity of the reflected light illuminated by an LED (475 nm). The response was proportional to the HCHO concentration at a constant sampling time and flow rate; 0.05 ppm HCHO, which is under the standard value set by the World Health Organization, was able to be detected in 5 min. The detection limit was 0.005 ppm. This monitoring system was not interfered by carbonyl compounds such as acetaldehyde and acetone, alcohols, hydrocarbons, and typical gases such as carbon monoxide, carbon dioxide, nitrogen dioxide, etc., which contributes to the measurement of correct HCHO concentrations. It was possible to monitor the HCHO gas in the room of a new apartment and school using this instrument; the response values were in good agreement with those obtained by the standard DNPH method. This highly sensitive, selective, and handy HCHO gas monitor is widely applicable and convenient for users who are not specialists in this field.

Air Pollution, Indoor↗

RTWPMS: a real-time wireless physiological monitoring system.

This paper demonstrates the design and implementation of a real-time wireless physiological monitoring system for nursing centers, whose function is to monitor online the physiological status of aged patients via wireless communication channel and wired local area network. The collected data, such as body temperature, blood pressure, and heart rate, can then be stored in the computer of a network management center to facilitate the medical staff in a nursing center to monitor in real time or analyze in batch mode the physiological changes of the patients under observation. Our proposed system is bidirectional, has low power consumption, is cost effective, is modular designed, has the capability of operating independently, and can be used to improve the service quality and reduce the workload of the staff in a nursing center.

Computer Systems↗

A neuromuscular monitoring system based on a personal computer.

We have developed a computerized neuromuscular monitoring system (NMMS) using commercially available subsystems, i.e., computer equipment, clinical nerve stimulator, force transducer, and strip-chart recorder. This NMMS was developed for acquisition and analysis of data for research and teaching purposes. Computer analysis of the muscle response to stimulation allows graphic and numeric presentation of the twitch response and calculated ratios. Since the system can store and recall data, research data can be accessed for analysis and graphic presentation. An IBM PC/AT computer is used as the central controller and data processor. The computer controls timing of the nerve stimulator output, initiates data acquisition, and adjusts the paper speed of the strip chart recorder. The data processing functions include establishing control response values (when no neuromuscular blockade is present), displaying force versus time and calculated data graphically and numerically, and storing these data for further analysis. The general purpose nature of the computer and strip chart recording equipment allow modification of the system primarily by changes in software. For example, new patterns of nerve stimulation, such as the posttetanic count, can be programmed into the computer system along with appropriate data display and analysis routines. The NMMS has functioned well in the operating room environment. We have had no episodes of electrocautery interference with the computer functions. The automated features have enhanced the utility of the NMMS.(ABSTRACT TRUNCATED AT 250 WORDS)

Computer Systems↗

Design of a portable urine glucose monitoring system for health care.

This paper describes the design of a monitoring system that can be used to measure urine glucose during daily life. It consists of a bio-chemical sensor, hardware with PIC microcontroller and control circuits, and signal analyzing part. To evaluate the performance, we compared the analyzed glucose levels of the developed system to a standard instrument, YSI glucose analyzer, based on regression analysis using standard glucose solutions mixed with urine. Also, standard deviation and coefficient of variation were computed. In conclusion, the developed system showed it could be used for the measurement of urine glucose.

Biosensing Techniques↗