Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Insufflation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Gas leak and gastric insufflation during controlled ventilation: face mask versus laryngeal mask airway.

PURPOSE: To compare two airway management techniques, face mask (FM) with oropharyngeal airway and laryngeal mask airway (LMA), with respect to the effectiveness of positive pressure ventilation and airway maintenance. METHODS: After induction of anaesthesia, two airway management techniques (FM or LMA) and three peak pressures (20, 25 and 30 cm H2O) were randomly applied during controlled ventilation in 60 patients. Data collected included inspiratory and expiratory volumes and presence of gastro-oesophageal insufflation. Leak was calculated by subtracting the expiratory from the inspiratory volume, expressed as a fraction of the inspiratory volume. RESULTS: Expiratory volumes (mean +/- SD) at 20, 25 and 30 cm H2O for LMA ventilation were 893 +/- 260, 986 +/- 276 and 1006 +/- 262 respectively, and for FM ventilation 964 +/- 264, 1100 +/- 268 and 1116 +/- 261. Leak fractions at 20, 25 and 30 cm H2O for LMA ventilation were 0.21 +/- 0.15, 0.24 +/- 0.18 and 0.26 +/- 0.18 respectively, and for FM ventilation 0.14 +/- 0.09, 0.14 +/- 0.09 and 0.12 +/- 0.08. The frequency of gastro-oesophageal insufflation was 1.6%, 5% and 5% for the LMA and 5%, 15% and 26.6% for the FM for ventilation pressures of 20, 25 and 30 cm H2O respectively which was greater with LMA use. CONCLUSION: Ventilation was adequate in all patients using both techniques. Leak was pressure dependent and greater with LMA use. Most of the leak was vented to the atmosphere via the pharynx. Gastro-oesophageal insufflation was more frequent with ventilation using the face mask. LMA use with positive pressure ventilation would appear to be a better airway management method than the face mask.

Adult↗

Increased insufflation pressure enhances the development of liver metastasis in a mouse laparoscopy model.

Despite the widespread use of laparoscopic techniques for colorectal cancer surgery, little is known about the potential risk of liver metastasis following CO2 pneumoperitoneum. We investigated the effect of different insufflation pressures and durations of CO2 pneumoperitoneum on the growth of liver metastasis in a mouse model. Six- to 7-week old male BALB/C mice were intraportally inoculated with 2 x 10(4) Colon 26 cells and randomly allocated to receive either CO2 pneumoperitoneum at different pressures (5 mmHg, 10 mmHg, or 15 mmHg), xiphoid-pubic laparotomy, or no treatment other than tumor cell inoculation. Mice undergoing pneumoperitoneum or laparotomy were then subdivided by the duration of treatment (30 minutes or 60 minutes). Cancer nodules on the liver surface from a total of 122 mice were evaluated on the 14th postoperative day. Similar to full laparotomy, CO2 pneumoperitoneum at 10 mmHg and 15 mmHg for 60 minutes, and pneumoperitoneum at 15 mmHg for 30 minutes significantly promoted the growth of cancer nodules on the liver surface. Enhancement of tumor growth was influenced by increased insufflation pressures (p < 0.05) rather than the prolonged length of pneumoperitoneum (p = 0.53) without significant interaction (p = 0.49). These results suggest that an increased insufflation pressure promotes the growth of liver metastases as well as laparotomy in this animal model. growth of liver metastases in a mouse laparoscopy model, following different pressures and durations of CO2 pneumoperitoneum, which is used most often in laparoscopic procedures.

Animals↗

The clinical impact of warmed insufflation carbon dioxide gas for laparoscopic cholecystectomy.

BACKGROUND: Reports suggest that the insufflation of cold gas to produce a pneumoperitoneum for laparoscopic surgery can lead to an intraoperative decrease in core body temperature and increased postoperative pain. METHODS: In a randomized controlled trial with 20 patients undergoing laparoscopic cholecystectomy, the effect of insufflation using carbon dioxide gas warmed to 37 degrees C (group W) was compared with insufflation using room-temperature cold (21 degrees C) gas (group C). Intraoperative body core and intra-abdominal temperatures were determined at the beginning and end of surgery. Postoperative pain intensity was evaluated using a visual analog scale and recording the consumption of analgesics. RESULTS: There were no significant group-specific differences during the operation, neither in body temperature (group W: 36.1 +/- 0.4 degrees C vs group C: 35.7 +/- 0.6 degrees C) nor in intra-abdominal temperature (group W: 35.9 +/- 0.3 degrees C vs group C: 35.6 +/- 0. 6 degrees C). Postoperatively, the two groups did not differ in pain susceptibility and need of analgesics. CONCLUSION: The use of carbon dioxide gas warmed to body temperature to produce a pneumoperitoneum during short-term laparoscopic surgery has no clinically important effect.

Aged↗

Delayed-type hypersensitivity response is better preserved in mice following insufflation than after laparotomy.

BACKGROUND: Our laboratory has previously used pig and rat models to demonstrate that delayed-type hypersensitivity (DTH) response to an antigen challenge is suppressed following laparotomy compared to insufflation. The purpose of this study was to develop a practical and reliable mouse DTH model that could be used in future studies to test immunomodulating drugs and therapies. METHODS: Female C3H/HeN mice (n = 100) were given three serial DTH challenges of 25 microl of 4 mg/ml phytohemagglutinin (PHA) 12 days before the test procedure, immediately following the test procedure, and on the 2nd postoperative day. All challenges were administered via subcutaneous injection in alternating footpads. The thickness of the footpad was determined with electronic calipers immediately prior to injection and 24 h following injection in a blinded fashion. The difference in thickness represents the response. On the day of the procedure, mice were randomized into the following three groups: (a) control (AC), (b) insufflation (INS), and (c) open (OPEN). AC mice underwent no procedure. INS mice underwent CO(2) insufflation at 2-4 mmHg for 20 min. OPEN mice underwent a midline incision from xiphoid to pubis that was closed after 20 min. Data were analyzed using ANOVA and Tukey-Kramer tests to determine differences between groups. RESULTS: Preoperatively, there were no significant differences among the three groups. On POD1, the OPEN group had significantly less response than both the AC and INS groups. On POD3, there were significant differences between the OPEN group and both the INS and AC groups. There was no significant difference between the AC and INS group at any time. CONCLUSIONS: In conclusion, a DTH mouse model has been established that allows serial assessment of cell-mediated immune function. This model can be used to study immune function after open and minimal access procedures in a simple and cost-effective manner.

Animals↗

Investigation of the activity of bronchodilators using a simple but accurate inhalation procedure: forced insufflation.

A simple but accurate inhalation procedure for investigating the activity of antiasthmatic drugs is proposed. The procedure consists of the forced insufflation of the powdered drug, blended with micronised lactose, direct into the tracheobronchial tree. Beta-adrenoceptor agonists (isoproterenol and fenoterol) and antimuscarinics (atropine and ipratropium bromide) were tested using the method of Konzett and Rössler in the guinea-pig; their bronchodilator effects were tested both after forced insufflation and after intravenous administration. The proposed inhalation method supplied close-response curves qualitatively comparable to those obtained by the intravenous route, with the added advantage of more detailed information on the time-course effect. Forced insufflation may be the best procedure for investigating antiasthmatic drugs intended for use as inhalants.

Adrenergic beta-Agonists↗

Comparison of gastrostomy tube replacement verification using air insufflation versus gastrograffin.

OBJECTIVE: To compare the safety of air insufflation as a contrast medium for percutaneous endoscopic gastrostomy (PEG) tube replacement verification with that of the more traditional method using positive contrast material (gastrograffin) under fluoroscopic guidance. DESIGN: Retrospective case series comparing 2 radiographic procedures used for PEG tube verification at a rehabilitation hospital. The first series reviewed studies of patients over 1 year, during which the method of choice for PEG tube replacement verification was with air insufflation. The second series reviewed studies of patients over the subsequent year, during which the method of choice for PEG tube replacement verification was with gastrograffin. SETTING: An inpatient rehabilitation hospital. PARTICIPANTS: Nineteen patients and 29 PEG tube replacements were identified that used air insufflation and 17 patients and 19 PEG tube replacements were identified that used gastrograffin. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Medical complications in a 2-week follow-up period as a result of the verification procedures. RESULTS: There were no cases in either of the replacement procedures in which the PEG tube was found to not be in the gastrointestinal system. There was also no evidence at 2-week follow-up that any of the patients' complications were the result of either procedure. CONCLUSIONS: The air contrast procedure appears to be a relatively safe alternative procedure for PEG tube replacement verification.

Adolescent↗

The use of air or CO2 as insufflation agents for double contrast barium enema (DCBE): is there a qualitative difference?

One hundred consecutive out-patients referred for double contrast barium enema (DCBE) were randomized in a double-blind prospective study to receive either air or CO2 as an insufflation agent. Each examination was performed by the same radiologist and radiographer. The two groups were equally matched for age and sex. Each completed examination was independently assessed by three radiologists for a variety of parameters. The results show that the patients receiving air as an insufflation agent had better overall colonic distension than the group receiving CO2 and that this was statistically significant (P = 0.0004). There was no significant difference in the mean time taken to perform the examination in the two groups nor was there any significant difference in mucosal coating or preparation. In conclusion, our results suggest that poor colonic distension is a potential problem when CO2 is used for DCBE and that this cannot be solely attributed to the time taken to perform the examination. Poor distension could lead to diagnostic errors and this may outweigh the advantages in patient acceptability when using CO2 as an insufflation agent.

Adult↗

A single computer-controlled mechanical insufflation allows determination of the pressure-volume relationship of the respiratory system.

OBJECTIVE: To evaluate and further develop a method for determination and mathematical characterisation of the elastic pressure-volume (Pel-V) relationship in mechanically ventilated human subjects during one single modified insufflation with simultaneous determination of resistance of the respiratory system. SUBJECTS: Eight adult non-smoking human subjects without heart, lung, or thoracic cage disease scheduled for non-thoracic surgery. The study was performed in anaesthetised and muscle-relaxed subjects. MEASUREMENTS AND MAIN RESULTS: The Pel-V curve was determined with a computer-controlled Servo Ventilator 900C during a modified insufflation with either constant or sinusoidally varying flow. Pressure and flow were measured with the built-in sensors of the ventilator. Tracheal pressure (Ptr) was calculated by subtracting the pressure drop over the tracheal tube. The elastic recoil pressure in the peripheral lung, Pel, was obtained from the calculated Ptr by subtracting the pressure drop over the airways. Ptr was also directly measured through a catheter. The calculated Ptr gave similar results as the directly measured Ptr, thus indicating the reliability of the signal originating from the ventilator sensor for computation of downstream pressures. The inflection points of the sigmoidal Pel-V curve and the compliance of the linear segment were determined with high reproducibility. CONCLUSIONS: Using one single modified insufflation allows a fast and accurate determination of respiratory mechanics. The Pel-V curves were determined with high reproducibility and were adequately described by a three-segment model of the curve incorporating a linear segment between two asymmetrical non-linear segments.

Adult↗

Warming of insufflation gas during laparoscopic hysterectomy: effect on body temperature and the autonomic nervous system.

BACKGROUND: Hypothermia is a known side effect of laparoscopic operations. It may increase the sympathetic activity of the autonomic nervous system (ANS), which can be evaluated noninvasively by heart rate variability (HRV). We tested the hypothesis that warming of the delivered CO2 insufflation gas helps to maintain the normal body temperature. METHODS: Thirty-seven healthy women undergoing laparoscopic hysterectomy were randomized into heated (37 degrees C, n=18) or unheated (24 degrees C, n = 19) gas insufflation groups. Anesthesia was induced with propofol and maintained with sevoflurane in O2-air. Tympanic (ttymp) temperature was recorded before, during and after the operation. Nasopharyngeal (tnaso) temperature was recorded only during operation. Electrocardiograms were recorded and stored to evaluate changes in HRV. The individual changes in HRV were compared after decibel (dB) transformation. RESULTS: A median decrease in tympanic temperatures during the operation was 0.7 degrees C in the heated and 0.3 degrees C in the unheated group (P = 0.01 between groups), and in nasopharyngeal 0.3 degrees C and 0.1 degrees C (P = 0.03), respectively. Preanesthetic tympanic values were reached within 90 min after anesthesia. After dB transformation, HRV high frequency power differed between the groups. It was better preserved in the patients receiving unheated gas. CONCLUSION: The heating of insufflation gas does not prevent a decrease in body temperature and is thus unnecessary during laparoscopic hysterectomy.

Adult↗

Peritoneal host defenses: modulation by carbon dioxide insufflation.

BACKGROUND: The host response to inflammatory stimuli in the peritoneal cavity consists of coordinated interactions of physical factors, cells, and soluble mediator molecules. Following infection, this is characterized by rapid eradication of large numbers of bacteria via the diaphragmatic lymphatics, clearance of bacteria through phagocytosis and intracellular killing, and, finally, sequestration of residual bacteria by inflammatory fibrinous exudate. Increasingly, surgical infections and major operations with the potential for postoperative infection are being managed laparoscopically, with CO(2) insufflation. The effects of CO(2) on intraperitoneal host defenses are still being defined. METHODS: Review of the pertinent literature and results from our laboratory. RESULTS: Exposure of peritoneal macrophages in vitro to CO(2) causes intracellular acidification, which in turn suppresses production of tumor necrosis factor (TNF) in response to exposure to lipopolysaccharide (LPS). In comparison, neither room air nor helium had any effect on cytosolic pH or the peritoneal macrophage response to LPS. Insufflation of CO(2) into the preperitoneal space in vivo caused similar peritoneal lining acidosis and reduced TNF production compared with insufflation of helium. CONCLUSION: CO(2) pneumoperitoneum created during laparoscopy appears to exert immunosuppressive effects through its ability to acidify the intracellular compartment of inflammatory cells. This may contribute to the improved recovery in patients undergoing laparoscopic surgery.

Carbon Dioxide↗

Esophageal insufflation and videofluoroscopy for evaluation of esophageal speech in laryngectomy patients: clinical implications.

Esophageal speech proficiency in 75 laryngectomy patients was rated on a seven-point scale by a speech therapist. Radiologic evaluation of the reconstructed pharyngoesophageal (PE) region during swallowing, attempted phonation, and phonation, by means of esophageal insufflation and barium-enhanced videofluoroscopy and spot radiography revealed the PE segment to be normal in 13 patients and hypotonic in 21. Hypertonicity or spasm of the PE segment was detected in 28 patients. Three patients had a postoperative stricture. Speech in 24 patients was fluent at the time of assessment; the remainder had negligible speech. Correlation between esophageal speech fluency and response at insufflation was highly positive. Esophageal insufflation, when combined with radiologic assessment, provides a reproducible method for accurate evaluation of the PE transition zone. Videofluoroscopy allowed good visualization of tracheoesophageal dynamics. Results indicated anatomic factors in the reconstructed PE region to profoundly affect the acquisition of esophageal speech.

Adult↗

Effect of cardiogenic oscillations on gas mixing during tracheal insufflation of oxygen.

In a previous study using tracheal insufflation of O2 (TRIO) at a rate of 2 l/min, we showed that anesthetized paralyzed dogs could be adequately oxygenated for up to 5 h, albeit with hypercapnia (mean arterial PCO2 approximately 160 Torr). To examine the contribution of cardiogenic oscillations in producing this gas exchange, we studied seven anesthetized paralyzed dogs weighing between 19.6 and 25.5 kg and quantified gas transport by analyzing continuous N2-washout curves in vivo and postmortem. We found that cardiogenic oscillations increase gas mixing roughly fourfold and that this value was independent of insufflation flow rate (0.2-10.0 l/min). Our results lend indirect evidence that, with regard to gas exchange, there are two mechanistically different zones in the lung during TRIO. One zone, located in the more peripheral areas of the lung, is dominated by the effects of cardiac oscillations and molecular diffusion and accounts for the increase in gas mixing found in the alive vs. dead dog. A second zone, close to the insufflated jet of O2, uses convective streaming to produce greater gas mixing at higher flows.

Aerosols↗

Cardiovascular collapse caused by carbon dioxide insufflation during one-lung anaesthesia for thoracoscopic dorsal sympathectomy.

Carbon dioxide insufflation into the pleural space during one-lung anaesthesia for thoracoscopic surgery is used in some centres to improve surgical access, even though this practice has been associated with well-described cardiovascular compromise. The present report is of a 35-year-old woman undergoing thoracoscopic left dorsal sympathectomy for hyperhidrosis. During one-lung anaesthesia the insufflation of carbon dioxide into the non-ventilated hemithorax for approximately 60 seconds, using a pressure-limited gas inflow, was accompanied by profound bradycardia and hypotension that resolved promptly with the release of the gas. Possible mechanisms for the cardiovascular collapse are discussed, and the role of carbon dioxide insufflation as a means of expediting lung collapse for procedures performed using single-lung ventilation is questioned.

Adult↗

Beneficial effects of humidified, warmed carbon dioxide insufflation during laparoscopic bariatric surgery: a randomized clinical trial.

BACKGROUND: Recent data has shown that the use of warmed, humidified carbon dioxide (CO2) insufflation during laparoscopic surgery may be associated with better outcomes. METHODS: We performed a randomized, doubleblind, prospective controlled clinical trial of 30 patients undergoing laparoscopic Roux-en-Y gastric bypass (LRYGBP). Patients were randomized into 2 groups. The first group (group 1, n=15) received standard (dry, room temperature) CO2 for insufflation during the surgery, while the second group (group 2, n=15) received warmed (35 degrees C) and humidified (95%) CO2. Patients received postoperative analgesia from morphine delivered via a patient-controlled analgesia (PCA) pump. Pain scores (on a scale of 0 to 10, 0 being no pain and 10 being the worst pain) were measured postoperatively at 3 h, 6 h, 1 day and 2 days. The amount of morphine that was delivered through the PCA was also measured at the same time intervals. Operating-room (OR) time, core temperature, and total hospital length of stay were documented. RESULTS: Postoperative pain as documented by pain scores and narcotic usage were not statistically different in the 2 groups. We demonstrated a statistically significant difference (mean+/-SD) in OR time (76+/-16 min vs 101+/-34 min, P=0.02), total hospital length of stay (3.2+/-.4 days vs 4.0+/-.9 days, P=0.01) and end-of-case core temperature (36.2+/-.5 degrees C vs 35.7+/-.6 degrees C, P=0.02) in group 2 compared with group 1. CONCLUSION: The use of warmed, humidified CO2 insufflation in bariatric patients undergoing LRYGBP was not associated with any significant benefit with regards to postoperative pain.

Adult↗

The laryngeal tube compared with the laryngeal mask: insertion, gas leak pressure and gastric insufflation.

BACKGROUND: We have compared the laryngeal tube and laryngeal mask in 22 patients for the success rate of insertion, gas leak pressure and the incidence of gastric insufflation. METHOD: In a randomized, crossover design, the laryngeal tube and laryngeal mask were inserted in turn after induction of anaesthesia and neuromuscular block. The cuffs were inflated until the intracuff pressure reached 60 cm H(2)O. We measured adequacy of ventilation and the minimum airway pressure at which gas leaked around the cuff. The presence or absence of gastric insufflation was studied at an inflation pressure of 20 cm H(2)O. RESULTS: It was possible to ventilate through the laryngeal tube in 21 patients and through the laryngeal mask in 21 patients. The mean leak pressure for the laryngeal tube (26 (SD 5) cm H(2)O) was significantly greater than that for the laryngeal mask (19 (4) cm H(2)O) (P<0.01; 95% confidence intervals for mean difference: 5.3-10.2 cm H(2)O). Gastric insufflation did not occur when the laryngeal tube was used and was noted in three patients when the laryngeal mask was used. CONCLUSION: The laryngeal tube provides a better seal in the oropharynx than the laryngeal mask.

Adolescent↗

Coping with extraperitoneal insufflation during laparoscopy: a new technique.

For most laparoscopists, pneumoperitoneum is essential before introducing a trocar into the peritoneal cavity. Extraperitoneal insufflation is one of the most common complications of laparoscopy; it is difficult to correct and may result in abandonment of the procedure. A technique for dealing with extraperitoneal insufflation is described. We have used this technique successfully on 11 consecutive patients. The gynecologist uses the view created by the extraperitoneal gas to place the Veress needle correctly into the peritoneal cavity. Insufflation proceeds under direct vision; the peritoneum will rise and obliterate the extraperitoneal space. This technique may be useful particularly when alternative methods are contraindicated.

Female↗

Variations in gas flow of laparoscopic insufflators.

Maintenance of an adequate pneumoperitoneum is important in laparoscopy, yet little is known about the functioning of laparoscopic insufflators except for the manufacturer's description of the specifications. Frequent failure to maintain an established pneumoperitoneum with the insufflator switched to its automatic mode prompted evaluation of the volume of gas delivered per unit of time by machines in active use. Limited standardization was found between machines in regard to the gas flow mediated by the automatic flow control. In this mode, the insufflator did not adequately compensate for changes in resistance to flow. Disparity of response among flow control devices and interinstrument variations suggest the need to test and calibrate each unit separately for clinical use.

Calibration↗

[Role of tubal insufflation in the postoperative follow-up of évidement cavities].

The authors report their experience of tubal insufflation in the post-operative care of cavity évidement. Their indications consist of évidement cavities with persistent residual muco-purulent otorrhoea or "glue ear" from the atrial area which remains thickened, while the rest of the cavity is healed (about 15% in their statistics). The technique is simple, consisting essentially of insufflations of air by means of an Itard catheter, which are repeated at regular intervals for a variable period of time. In some cases, drugs, in particular corticosteroids, are injected into the cavity via the catheter. In a series of 17 operated patients, the authors report: 9 excellent results in which drying of the cavity was obtained in record time; 4 good results in which drying of the cavity required numerous insufflations associated with systemic treatment (vaccine therapy, crenotherapy); 1 moderate result with transient persistent otorrhoea; 3 failures.

Air↗