Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IONS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Negative surface charge near sodium channels of nerve: divalent ions, monovalent ions, and pH.

Evidence is given for a high density of negative surface charge near the sodium channel of myelinated nerve fibres. The voltage dependence of peak sodium permeability is measured in a voltage clamp. The object is to measure voltage shifts in sodium activation as the following external variables are varied: divalent cation concentration and type, monovalent concentration, and pH. With equimolar substitution of divalent ions the order of effectiveness for giving a positive shift is: Ba equals Sr less than Mg less than Ca less than Co approximately equal to Mn less than Ni less than Zn. A tenfold increase of concentration of any of these ions gives a shift of +20 to +25 mV. At low pH, the shift with a tenfold increase in Ca-2+ is much less than at normal pH, and conversely for high pH. Soulutions with no added divalent ions give a shift of minus 18 mV relative to 2 mM Ca-2+. Removal of 7/8 of the cations from the calcium-free solution gives a further shift of minue 35 mV. All shifts are explained quantitatively by assuming that changes in an external surface potential set up by fixed charges near the sodium channel produce the shifts. The model involves a diffuse double layer of counterions at the nerve surface and some binding of H+ions and divalent ions to the fixed charges. Three types of surface groups are postulated: (1) an acid pKa equals 2.88 charge density minus 0.9 nm- minus 2; (i) an acid pKa equals 4.58, charge density minus 0.58 nm- minus 2; (3) a base pKa equals 6.28, charge density +0.33 nm- minus 2. The two acid groups also bind Ca-2+ ions with a dissociation constant K equals 28 M. Reasonable agreement can also be obtained with a lower net surface charge density and stronger binding of divalent ions and H+ ions.

Animals↗

Possible influence of cell walls upon ion concentrations at plasma membrane surfaces. Toward a comprehensive view of cell-surface electrical effects upon ion uptake, intoxication, and amelioration.

Plant uptake of ions, intoxication by ions, and the alleviation of intoxication by other ions often correlate poorly with ion concentrations in the rooting medium. By contrast, uptake, intoxication, and alleviation correlate well with ion concentrations at the plasma membrane (PM) surface computed as though the PM were bathed directly in the rooting medium with no effect from the cell wall (CW). According to two separate lines of analysis, a close association of CWs and PMs results in a slight increase in cation concentrations and a slight decrease in anion concentrations at the PM surface compared with concentrations when the CW is separated or has no effect. Although slightly different, the ion concentrations at the PM surface computed with and without close association with the CW are highly correlated. Altogether, the CW would appear to have a small effect upon ion uptake by the PM or upon intoxication or alleviation of intoxication originating at the PM surface. These analyses have been enabled by the recent evaluation of parameters required for the electrostatic models (Gouy-Chapman-Stern and Donnan-plus-binding) used to compute electrical potentials and ion concentrations in CWs and at PM surfaces.

Cell Membrane↗

Evaluation of selected-ion storage ion-trap mass spectrometry for detecting urinary anabolic agents.

Limits of detection are important issues for GC/MS screening for anabolic agents and for confirmation of various drugs of abuse. We compared a quadrupole ion trap (QIT) operated in two different selected-ion storage modes and a quadrupole mass filter (QMF) operated in the selected-ion monitoring mode. Results with the model compound tetrachlorobenzene indicate that, for simultaneous monitoring of more than four ions, the QIT operated in a frequency-modulated selected-ion storage mode has better limits of detection than the QMF. Use of a single-ion storage technique gave results similar to those of the QMF. We also evaluated both QIT selected-ion storage approaches for the limits of detection of the trimethylsilyl derivatives of four anabolic steroid metabolites and the beta-agonist clenbuterol. We found no improvement in detection limits over that of a similar method with selected-ion monitoring and a QMF when four anabolic steroid metabolites and clenbuterol were extracted from a urine matrix. The lack of improvement in the limit of detection resulted from matrix background signals at masses similar to those of the steroids.

Anabolic Agents↗

Ligand-gated ion channels: mechanisms underlying ion selectivity.

Anion/cation selectivity is a critical property of ion channels and underpins their physiological function. Recently, there have been numerous mutagenesis studies, which have mapped sites within the ion channel-forming segments of ligand-gated ion channels that are determinants of the ion selectivity. Site-directed mutations to specific amino acids within or flanking the M2 transmembrane segments of the anion-selective glycine, GABA(A) and GABA(C) receptors and the cation-selective nicotinic acetylcholine and serotonin (type 3) receptors have revealed discrete, equivalent regions within the ion channel that form the principal selectivity filter, leading to plausible molecular mechanisms and mathematical models to describe how ions preferentially permeate these channels. In particular, the dominant factor determining anion/cation selectivity seems to be the sign and exposure of charged amino acids lining the selectivity filter region of the open channel. In addition, the minimum pore diameter, which can be influenced by the presence of a local proline residue, also makes a contribution to such ion selectivity in LGICs with smaller diameters increasing anion/cation selectivity and larger ones decreasing it.

Animals↗

Biological ion exchanger resins. I. Quantitative electrostatic correspondence of fixed charge and mobile counter ion.

Utilizing Escherichia coli as the prototype of an ion-accumulating cell, the ion exchange isotherm is introduced as a concise method of characterizing biological ion exchange events. The ion exchange isotherm for the alkali cation exchange, K <--> Na, is described. The total charge profile of this bacterium is compiled and compared for bacteria in the Na form and in the K form. Macromolecule fixed charge was found to provide 80% of the counter ions that pair with potassium. Therefore, in its physiological state, 80% of the cell potassium in E. coli is associated with an ion exchange site on a macromolecule. The primary cation exchange sites are found to be about equally divided between carboxylate and phosphate sites indicating that E. coli is a bifunctional resin with respect to cation exchange. During substrate-dependent cation accumulation ("active transport"), phosphate esters and organic acids were shown to accumulate. One may conclude that the role of intermediate metabolism in "active transport" is to increase the ion exchange capacity of the biological resin by the production of charged metabolites that sorb to the framework of the resin.

Amines↗

Evidence for ion chain mechanism of the nonlinear charge transport of hydrophobic ions across lipid bilayers.

The conductivity across a lipid bilayer by tetraphenylborate anion is increased 10-fold on the photoformation of lipophilic porphyrin cations. The cations alone have negligible conductivity. This nonlinear photogenerated increase of ion conductivity is termed the photogating effect. Substitution of H by Cl in the para position of tetraphenylborate leads to a 100-fold enhancement of conductivity, whereas the dark conductivities for this and other substituted borates are the same. Moreover, the halo-substituted borates show a large enhancement of conductivity in the low concentration range (10(-8) M), whereas that of tetraphenylborate is small and space charge is negligible. The enhanced ion conductivity has great structural sensitivity to the structure of the anion, the cation, and the lipid, whereas the partition coefficient of all the borates and the concentration of photoformed cations are only slightly affected. The photogated ion transport has a twofold larger activation energy than transport in the dark. Time-resolved photocurrents and voltages demonstrate that the translocation rate of the porphyrin cation is also enhanced 100-fold by the Cl-borate anion but only 10-fold by the H-borate anion. For these reasons the nonlinear gating effect cannot be explained by electrostatics alone, but requires an ion chain or ion aggregate mechanism. Kinetic modeling of the photoinduced current with a mixed cation-anion ion chain can fit the data well. The photogating effect allows the direct study of ion interactions within the bilayer.

1,2-Dipalmitoylphosphatidylcholine↗

Hydrogen ions control synaptic vesicle ion channel activity in Torpedo electromotor neurones.

During exocytosis the synaptic vesicle fuses with the surface membrane and undergoes a pH jump. When the synaptic vesicle is inside the presynaptic nerve terminal its internal pH is about 5.5 and after fusion, the inside of the vesicle comes in contact with the extracellular medium with a pH of about 7.25. We examined the effect of such pH jump on the opening of the non-specific ion channel in the synaptic vesicle membrane, in the context of the post-fusion hypothesis of transmitter release control. The vesicles were isolated from Torpedo ocellata electromotor neurones. The pH dependence of the opening of the non-specific ion channel was examined using the fused vesicle-attached configuration of the patch clamp technique. The rate of opening depends on both pH and voltage. Increasing the pH from 5.5 to 7.25 activated dramatically the non-specific ion channel of the vesicle membrane. The single channel conductance did not change significantly with the alteration in the pH, and neither did the mean channel open time. These results support the hypothesis that during partial fusion of the vesicle with the surface membrane, ion channels in the vesicle membrane open, admit ions and thus help in the ion exchange process mechanism, leading to the release of the transmitter from the intravesicular ion exchange matrix. This process may have also a pathophysiological significance in conditions of altered pH.

Animals↗

Multiple-point adsorption of terbium ions by lead ion templated thermosensitive gel: elucidating recognition of conformation in gel by terbium probe.

Lead ion templated thermosensitive heteropolymer gel which has recognition ability of methacrylate pairs has been synthesized and characterized. The gel consists of a main monomer component, N-isopropylacrylamide (NIPA), responsible for volume phase transition, methacrylic acid (MAA) moieties imprinted as pairs to adsorb terbium ions and cross-links. An imprinting technique was applied using lead ion complex with methacrylate ligands in dioxane media. After gel was obtained, lead ions were removed by washing and the imprinted gel showed strong binding ability to terbium ions, comparable with that of the non-imprinted gel prepared without lead ions. It was found that the Tb(3+) fluorescence intensity was considerably increased upon binding this ion to both imprinted and non-imprinted gels, but the largest enhancement of fluorescence intensity was observed when Tb(3+) was bound to imprinted gel in shrunken state. This is because of the decrease of coordinated water molecules on Tb(3+) and the strong binding of this ion to methacrylate pairs which are encoded within the weakly cross-linked network of imprinted gel.

Acrylamides↗

Non-linearity influences on the axial secular-motion spectrum of ions confined in a Fourier transform ion trap mass spectrometer. Experimental studies.

A Fourier transform operating mode is applied to an ion trap. The trap is truncated at 2r(0) and presents unwanted defects that induce confinement electric-field non-linearities. Ion axial secular-motion spectrum is examined by experiments near the resonance line beta(z) = 0.5. Ion-loss processes and ion axial-motion peak splitting are observed. In the non-linear ion trap, the ion-motion frequency depends on its initial conditions in position and velocity. This brings an enlargement of the motion-frequency peak and limits the resolution. With a 2r(0) truncated ion trap, the Fourier transform ion trap mass spectrometer (FTIT-MS) leads experimentally to a mass resolution of about 4000 at 130 u.

Journal Article↗

Is proton cationization promoted by polyatomic primary ion bombardment during time-of-flight secondary ion mass spectrometry analysis of frozen aqueous solutions?

Ion bombardment of pure water ice by Au+ monoatomic and Au3 + and C60 + polyatomic projectiles results in the emission of two series of water cluster ions-(H2O)n + and (H2O)nH+-with n ranging from 1 to >40. The cluster ion yields are very significantly higher under polyatomic ion bombardment than when using an Au+ primary ion. The yield of the protonated water species (H2O)nH+ is found to be enhanced by increasing ion fluence. C60 + bombardment results in a very dramatic increase in the (H2O)nH+ yield and decrease in the yield of (H2O)n +. Au3 + also significantly increased the yield of protonated species relative to the non-protonated but to a lesser extent than C60 +. Bombardment by Au+ also increased the yield of protonated species but to a very much smaller extent. The hypothesis that the protonated species may enhance the yield of [M+H]+ from solute molecules in solution has been investigated using two amino acids, alanine and arginine, and a nucleic base, adenine. The data suggest that the protons produced by the sputtering of water ice are depleted in the presence of these solutes and concurrently the yields of solute-related [M+H]+ and immonium secondary ions are greatly enhanced. These yield enhancements are analysed in the light of other possible contributors such as increased rates of sputtering under polyatomic beams and increased secondary ion yields as a consequence of solute dispersion. It is concluded that enhanced proton attachment is occurring in polyatomic sputtered frozen aqueous solutions.

Journal Article↗

Selective self-ion/molecule reactions in both external and internal source ion trap mass spectrometers.

Novel results on the selective self-ion/molecule reactions (SSIMR) in both external and internal source ion trap mass spectrometers are demonstrated. Selective self-ion/molecule reaction product ions were produced between the oxygenated and nitrogenated crown ethers. For the oxygenated crown ethers, self-ion/molecule reactions lead to the formation of the protonated ions, adduct ions of fragments ([M + F](+)) and [M + H(3)O](+), while the nitrogenated crown ethers produce [M + H](+), [M + CH](+) and [M + C(2)H(3)](+) ions.

Journal Article↗

Distributions of Li+, Na+ K+, Rb+, and Cs+ tracer ions in erythrocytes at 38 degrees C in relation to entry rates of these ions into cells at 0 degree C.

Forces that are able to transport Na+ and K+ into two compartments were investigated. A modified Nernst-Planck equation for coupled flows of electric current, water, and ions was integrated. The result shows that if alkali ions in the ion channel of the cell membrane are separated by their electric-current-induced inward flows against an electro-osmotic outward flow of water, the logarithms of the stationary cell/medium distributions of these ions should be proportional to the inverse of their diffusion mobilities. The relationship was tested in human erythrocytes. From inward and outward movements of tracer alkali ions, calculations were made to obtain their stationary distributions at infinite time. The cell/medium distributions determined in this way at 38 degrees C are Li+ = 0.59, 22Na+ = 0.044, 42K+ = 10.0, 86Rb+ = 11.9, and 137Cs+ = 3.07. The entry rates of ions into the cell at 0 degrees C are understood to represent their diffusion mobilities in the pump channel. The entry rates are Li+ = 1.44, 2Na+ = 1, 42K+ = 2.22, 86Rb+ = 2.39, and 137Cs+ = 1.72 relative to that of 22Na+. There is an expected negative correlation between the logarithms of the stationary cell/ medium distributions at 38 degrees C and the inverse of the entry rates into the cell at 0 degrees C for the five ions. It is suggested that the proposed physical forces cause the separation of alkali ions in the channel of Na,K-ATPase.

Biological Transport, Active↗

Synthetic metal-binding protein surface domains for metal ion-dependent interaction chromatography. II. Immobilization of synthetic metal-binding peptides from metal ion transport proteins as model bioactive protein surface domains.

This preliminary investigation tests the premise that biologically relevant (1) peptide-metal ion interactions, and (2) metal ion-dependent macromolecular recognition events (e.g., peptide-peptide interactions) may be modeled by biomimetic affinity chromatography. Divinylsulfone-activated agarose (6%) was used to immobilize three different synthetic peptides representing metal-binding protein surface domains from the human plasma metal transport protein histidine-rich glycoprotein (HRG). The synthetic peptides represented 1-3 multiple repeat units of the 5-residue sequence (Gly-His-His-Pro-His) found in the C-terminal of HRG. By frontal analyses, immobilized HRG peptides of the type (GHHPH)nG, where n = 1-3, were each found to have a similar binding capacity for both Cu(II) ions and Zn(II) ions (31-38 mumol/ml gel). The metal ion-dependent interaction of a variety of model peptides with each of the immobilized HRG peptide affinity columns demonstrated differences in selectivity despite the similar internal sequence homology and metal ion binding capacity. The immobilized 11-residue HRG peptide was loaded with Cu(II) ions and used to demonstrate selective adsorption and isolation of proteins from human plasma. These results suggest that immobilized metal-binding peptides selected from known solvent-exposed protein surface metal-binding domains may be useful model systems to evaluate the specificity of biologically relevant metal ion-dependent interaction and transfer events in vitro.

Amino Acid Sequence↗

Ion funnels for the masses: experiments and simulations with a simplified ion funnel.

A modified ion funnel is described. Counterintuitively, increased spacing between electrodes results in enhanced "focusing" of the ions through the funnel. Consequently, the internal diameter (i.d.) of the funnel need not decrease to the conductance limit (as in previous designs). A simple dc-only lens, which also serves as the conductance limit, combined with the natural flow of gas is used to extract the ions from the funnel. Ions with mass to charge ratios varying between 75 and 3000 m/z are passed through the funnel with no apparent discrimination. The funnel can be operated under mild conditions that preserve weakly bound noncovalent complexes. After testing several designs, a thin closely spaced dc lens was found to be the best solution for extracting ions. A simple method for simulating ion trajectories at nonzero pressures based on ion mobility and explicit diffusion is described. This theoretical approach was used to design and calculate ion trajectories for the modified funnel presented here. Finally, the increased spacing between electrodes in the current funnel significantly relaxes machining constraints, reduces cost, and enhances ease of use versus previous funnel designs.

Computer Simulation↗

Modeling ion permeation through batrachotoxin-modified Na+ channels from rat skeletal muscle with a multi-ion pore.

The mechanism of ion permeation through Na+ channels that have been modified by batrachotoxin (BTX) and inserted into planar bilayers has been generally described by models based on single-ion occupancy, with or without an influence of negative surface charge, depending on the tissue source. For native Na+ channels there is evidence suggestive of a multi-ion conduction mechanism. To explore the question of ion occupancy, we have reexamined permeation of Na+, Li+, and K+ through BTX-modified Na+ channels from rat skeletal muscle. Single-channel current-voltage (I-V) behavior was studied in neutral lipid bilayers in the presence of symmetrical Na+ concentrations ranging from 0.5 to 3,000 mM. The dependence of unitary current on the mole fraction of Na+ was also examined in symmetrical mixtures of Na(+)-Li+ and Na(+)-K+ at a constant total ionic strength of 206 and 2,006 mM. The dependence of unitary conductance on symmetrical Na+ concentration does not exhibit Michaelis-Menten behavior characteristic of single-ion occupancy but can be simulated by an Eyring-type model with three barriers and two sites (3B2S) that includes double occupancy and ion-ion repulsion. Best-fit energy barrier profiles for Na+, Li+, and K+ were obtained by nonlinear curve fitting of I-V data using the 3B2S model. The Na(+)-Li+ and Na(+)-K+ mole-fraction experiments do not exhibit an anomalous mole-fraction effect. However, the 3B2S model is able to account for the biphasic dependence of unitary conductance on symmetrical [Na+] that is suggestive of multiple occupancy and the monotonic dependence of unitary current on the mole fraction of Na+ that is compatible with single or multiple occupancy. The best-fit 3B2S barrier profiles also successfully predict bi-ionic reversal potentials for Na(+)-Li+ and Na(+)-K+ in both orientations across the channel. Our experimental and modeling results reconcile the dual personality of ion permeation through Na+ channels, which can display features of single or multiple occupancy under various conditions. To a first approximation, the 3B2S model developed for this channel does not require corrections for vestibule surface charge. However, if negative surface charges of the protein do influence conduction, the conductance behavior in the limit of low [Na+] does not correspond to a Gouy-Chapman model of planar surface charge.

Animals↗

Preclinical biological assessment of proton and carbon ion beams at Hyogo Ion Beam Medical Center.

PURPOSE: To assess the biologic effects of proton and carbon ion beams before clinical use. METHODS AND MATERIALS: Cultured cells from human salivary gland cancer (HSG cells) were irradiated at 5 points along a 190 MeV per nucleon proton and a 320 MeV per nucleon carbon ion beam, with Bragg peaks modulated to 6 cm widths. A linac 4 MV X-ray was used as a reference. Relative biologic effectiveness (RBE) values at each point were calculated from survival curves. Cells were also irradiated in a cell-stack phantom to identify that localized cell deaths were observed at predefined depth. Total body irradiation of C3H/He mice was performed, and the number of regenerating crypts per jejunal section was compared to calculate intestinal RBE values. For carbon ion and referential 4 MV X-ray beams, mouse right legs were irradiated by four-fractional treatment and followed up for skin reaction scoring. RESULTS: RBE values calculated from cell survival curves at the dose that would reduce cell survival to 10% (D10) ranged from 1.01 to 1.05 for protons and from 1.23 to 2.56 for carbon ions. The cell-stack phantom irradiation revealed localized cell deaths at predefined depth. The intestinal RBE values ranged from 1.01 to 1.08 for protons and from 1.15 to 1.88 for carbon ions. The skin RBE value was 2.16 at C320/6 cm spread-out Bragg peak (SOBP) center. CONCLUSION: The radiobiologic measurements of proton and carbon ion beams at Hyogo Ion Beam Medical Center are consistent with previous reports using proton beams in clinical settings and carbon ion beams with similar linear energy transfer (LET) values.

Animals↗

Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration.

Externally generated ions are accumulated in a linear octopole ion trap before injection into our 9.4 T Fourier transform ion cyclotron resonance (FT-ICR) mass analyzer. Such instrumental configuration has previously been shown to provide improved sensitivity, scan rate, and duty cycle relative to accumulated trapping in the ICR cell. However, inefficient ion ejection from the octopole currently limits both detection limit and scan rate. SIMION 7.0 analysis predicts that a dc axial electric field inside the linear octopole ion trap expedites and synchronizes the efficient extraction of the octopole-accumulated ions. Further SIMION analysis optimizes the ion ejection properties of each of three electrode configurations designed to produce a near-linear axial potential gradient. More efficient extraction and transfer of accumulated ions spanning a wide m/z range promises to reduce detection limit and increase front-end sampling rate (e.g., to increase front-end resolution for separation techniques coupled with FT-ICR mass analysis). Addition of the axial field improves experimental signal-to-noise ratio by more than an order of magnitude.

Journal Article↗

High-pressure ion source combined with an in-axis ion trap mass spectrometer. 1. Instrumentation and applications

A new combination of a dual EI/CI ion source with a quadrupole ion trap mass spectrometer has been realized in order to efficiently produce negative ions in the reaction cell. Analysis of volatile compounds was performed under negative ion chemical ionization (NICI) during a reaction period where selected reactant negative ions, previously produced in the external ion source, were allowed to interact with molecules, introduced by hyphenated techniques such as gas chromatography. The O2*-, CH3O-, and Cl- reactant ions were used in this study to ensure specific ion/molecule interactions such as proton transfer, nucleophilic displacement, or charge exchange processes, respectively leading to even-electron species, i.e., deprotonated [M - H]- molecules, diagnostic [M - R]- ions, or odd-electron M*- molecular species. The reaction orientation depends on the thermochemistry of reactions within kinetic controls. First analytical results are presented here for the trace-level detection of several contaminants under NICI/Cl- conditions. Phosphorus-containing compounds (malathion, ethyl parathion, and methyl parathion as representative for pesticides) and nitro-containing compounds (2,4,6-trinitrotoluene for explosive material) have been chosen in order to explore the analytical ability of this promising instrumental coupling.

Journal Article↗