Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Conductometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Isotachophoresis of proteins.

The analytical separation of proteins by isotachophoresis (ITP) was achieved in a short electrophoretic path and with a resolution comparable to that of isoelectric focusing by the appropriate selection of (1) a mixture of ampholytes as spacers to generate linear gradients of electrophoretic mobility and (2) the counter ions chosen to buffer the complete pH gradient generated. This ITP technique is exemplified by the analysis of plasma proteins in agarose gels. Upto 46 samples in the same gel plate were analysed. The resolution was such that at least 30 clear and discrete bands per sample could be observed after staining with Coomassie Brilliant Blue. The resolving power of ITP could be further increased for the study of a particular protein or zone by the selection of suitable spacers and counter ions.

Blood Proteins↗

Application of a contactless conductometric detector for the simultaneous determination of small anions and cations by capillary electrophoresis with dual-opposite end injection.

A contactless conductometric detection (CCD) system for capillary electrophoresis (CE) with a flexible detection cell was applied for the simultaneous determination of small anions and/or cations in rain, surface and drainage water samples. The applied frequency, the amplitude of the input signal, the electrolyte conductivity and electrode distance were found to be the most significant factors affecting the detection sensitivity. 2-(N-Morpholino)ethanesulfonic acid/histidine-based (MES/His) electrolytes were used for direct conductivity detection of anions and cations, while ammonium acetate was selected for indirect conductivity determination of alkylammonium salts. For the simultaneous separation procedure, involving dual-opposite end injection, an electrolyte consisting of 20 mM MES/His, 1.5 mM 18-crown-6 and 20 microM cetyltrimethylammonium bromide provided baseline separation of 13 anions and cations in less than 6 min. The detection limits achieved were 7-30 micrograms/l for direct conductometric detection of various common inorganic cations and anions, excluding F- (62 micrograms/l) and H2PO4- (250 micrograms/l), and 35-178 micrograms/l for indirect conductometric detection of alkyl ammonium cations. The developed electrophoretic method with conductometric detection was compared to ion chromatography.

Anions↗

Quantitation of sulfate and thiosulfate in clinical samples by ion chromatography.

For assay of serum sulfate, quantitation by ion conductimetry after separation by anion-exchange chromatography is the method of choice. In comparison to classical barium precipitation methods, chromatographic methods demonstrate increased precision, specificity and sensitivity, and they may be superior to spectrophotometric methods that rely on organic cation precipitation of sulfate. The increased sensitivity and specificity, as well as the inherent capacity of chromatographic methods for simultaneous determination of other anions, has led to its increasing use in the determination of excreted sulfate in clinical profiles of urinary anion composition. Ion chromatography can also be used to quantitate free sulfate in other clinical samples, including cerebrospinal fluid, sweat, saliva, breast milk and human tissues. Finally, ion chromatography shows promise as a more precise and sensitive method for measurement of total acid-labile sulfoesters and thiosulfate.

Amniotic Fluid↗

Simultaneous separation of common mono- and divalent cations on silica gel modified with aluminium by non-suppressed ion chromatography with conductimetric detection and nitric acid-15-crown-5 as eluent.

The modification of silica gel with aluminium by a coating method was very effective for the preparation of silica-based stationary phases which acted as a cation exchanger under strongly acidic conditions. However, the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) on an aluminium-adsorbing silica (Al-Silica) column was moderate by a conductimetric detection ion chromatography (IC) with strongly acidic eluents. Then, the addition of various crown ethers (12-crown-4, 15-crown-5 and 18-crown-6) in acidic eluent was carried out. As a result, it was found that 15-crown-5 was most effective for the improvement of peak resolution. Excellent separation of these cations was achieved in 20 min by elution with 2 mM nitric acid-2 mM 15-crown-5. The proposed IC was successfully applied to the determination of major cations in various natural waters.

Aluminum↗

Electrophoretic mobility study on ion-ion interactions in an aqueous solution.

Ion-ion interactions between anions and their pairing ions in aqueous solutions were studied through the measurements of electrophoretic mobilities of analyte ions in capillary zone electrophoresis, where the electrophoretic method for the analysis of ion association reaction is shown to be more useful than the conductometric method widely used in the analysis of the reactions. The electrophoretic mobility of monovalent inorganic anions was almost identical even when the concentrations of alkali metal ions and quaternary ammonium ions in the migrating solution were varied up to 15 mM. On the other hand, the electrophoretic mobility of organic anions, such as monovalent and divalent anions, decreased with increasing concentrations of quaternary ammonium ions. Changes in the electrophoretic mobilities were analyzed by a non-linear least-squares method giving ion association constants. The results indicate that the proposed method is applicable to the analysis of such reactions to give the mobility change. The ion association constants obtained in an aqueous solution were related to the extraction constants of the ion associates, and the contributions of the association process and the distribution process were clarified.

Acids↗

Enhancement of conductometric detection of weak acids in ion chromatography.

Anions of weak acids can represent a problem when determined via chemically suppressed ion chromatography as the acids can be weakly ionised, giving low conductivity and hence low sensitivity. Previous work showed that converting some weak acids back to their sodium salts, using a second micromembrane suppressor, greatly enhanced conductivity and thus sensitivity. This paper will discuss further work in optimising the conversion for boric acid by using sodium salts of EDTA and the mechanisms involved.

Acids↗

Performance evaluation of a method for the determination of bromate in drinking water by ion chromatography (EPA method 317.0) and validation of EPA method 324.0.

The potential carcinogenic nature of bromate has prompted global regulatory agencies, and industrial and academic institutions to publish several methods for the analysis of bromate in both drinking and bottled waters. The United States Environmental Protection Agency (EPA) has reported two methods capable of detecting bromate at or below the promulgated maximum contaminant level of 10.0 microg/l. These methods are EPA Method 300.1 and 317.0. Method 300.1 has been promulgated by EPA for compliance monitoring of bromate under Stage 1 of the Disinfectants/Disinfection By-Products Rule. Due to its sensitivity, selectivity and simplicity, Method 317.0 has been drafted and evaluated for potential use as a future compliance monitoring method. This manuscript describes the performance evaluation work with Method 317.0 and efforts completed at EPA's Technical Support Center that improved the sensitivity of Method 317.0, leading to the development of EPA Method 324.0

Bromates↗

Micromeasurement of total and regional CO2 productions in the one-day-old chick embryo.

A conductometric micromethod combined with image analysis system has been developed allowing to determine the CO2 production within 'two-dimensional' tissues, i.e., flat and thin cell layers or epithelial sheets. The preparation was mounted into an airtight chamber separated in two compartments by a thin silicone membrane permeable to gases. The lower compartment contained the nutritive medium and the preparation. The upper compartment and a conductivity measuring capillary connected in series were perfused with a solution of Ba(OH)2. The CO2 produced by the tissue precipitated as BaCO3 and the resulting decrease of electrical conductivity was linearly related to the total CO2 production. In addition, the pattern of CO2 production was directly observable as the BaCO3 crystals formed upon the silicone membrane over the regions which produced CO2. The spatial distribution of the crystals was quantified by video image processing and the regional CO2 production evaluated with a spatial resolution of 100 microns. This new microtechnique was originally developed to study the CO2 production in the early chick blastoderm which is a disc 1-5 cells thick. At the stage of young neurula the CO2 production was found to be 235 +/- 37 nmol.h-1 (mean +/- SD; n = 10) per blastoderm and large variations of local CO2 production were detected from one region to another (from 0.6 to 6.5 nmol.h-1.mm-2). These results indicate a high metabolic and functional differentiation of cells within the blastoderm. The possible applications and improvements of such a microtechnique are discussed.

Animals↗

Study of the interactions between lysozyme and a fully-fluorinated surfactant in aqueous solution at different surfactant-protein ratios.

The interactions of a fluorinated surfactant, sodium perfluorooctanoate, with lysozyme, have been investigated by a combination of UV absorbance, electrical conductivity and dynamic light scattering to detect and to characterize the conformational transitions of lysozyme. By using difference spectroscopy, the transition was followed as a function of surfactant concentration, and the data were analyzed to obtain the Gibbs energy of the transition in water (DeltaGw(o)) and in a hydrophobic environment (DeltaGh(o)) for saturated protein-surfactant complexes. Electrical conductivity was used to determine the critical micelle concentration of the surfactant in the presence of different lysozyme concentration. From these results, the average number of surfactant monomer per protein molecule was calculated. Finally, dynamic light scattering show that only changes in the secondary structure of the protein can be observed.

Caprylates↗

Impedance microbiology: quantification of bacterial content in milk by means of capacitance growth curves.

The impedancimetric method is a technique for the rapid evaluation of milk bacterial content and also of its subproducts. Several authors have made use of culture conductance changes during bacterial growth for quantitative and qualitative assessments of microbial growth. However, interface capacitance curves, Ci, have not been used. In this paper, we quantify bacteria in cow raw milk by following their growth as the above-mentioned capacitance change time course event. With it, bigger growth variations, shorter detection times and a better coefficient of correlation with the plate count method were obtained than those yielded by conductance curves. Calibration was performed by plotting initial known concentrations, IC (CFU/ml), as a function of the time detection theshold (TDT).

Animals↗

Transdermal iontophoretic delivery of methylphenidate HCl in vitro.

Methylphenidate is prescribed orally for Attention Deficit Disorder in children and adults, and for narcolepsy patients. Methylphenidate has a short plasma half-life (1-2 h) and thus needs to be frequently administered for effective therapy. Such therapy has limitations in terms of patient compliance, particularly in young children. For such reasons, the development of a transdermal dosage form of methylphenidate may be useful. This study was undertaken to evaluate the passive and electrically assisted transport (iontophoresis) of methylphenidate from aqueous methylphenidate hydrochloride solutions across excised human skin. A maximum flux of 12.0 micrograms/(cm2 h) of protonated methylphenidate was estimated from the passive transport data at pH 3.5. Iontophoresis significantly enhanced protonated methylphenidate transport as compared with passive delivery. From the present experiments, the efficiency of iontophoretic delivery of methylphenidate was approximately 700 micrograms/(mA h). Based on in vitro skin flux data, the daily dose of 15-40 mg methylphenidate can be achieved using a current density of 0.5 mA/cm2 and a minimum transport area of 2-5 cm2 for 24-h application, or an area of 4-10 cm2 for 12-h (daytime) application. From methylphenidate skin flux values, methylphenidate mobility of 2.2 x 10(-4) cm2/(V s) was estimated, which compares reasonably with its free solution mobility of 6.6 x 10(-4) cm2/(V s).

Administration, Cutaneous↗