Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capsulorhexis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses.

The purpose of this study is to determine the effects of different anterior capsulotomy techniques and intraocular lens (IOL) types on IOL tilt and decentration. For this purpose the device using Purkinje reflections and photographic documentation were evaluated. A total of 107 cataractous eyes undergoing IOL implant surgery were divided into four groups based on the type of IOL and capsulotomy: group 1, single-piece polymethylmethacrylate (PMMA) IOL with a haptic distance of 13.50 mm; group 2, single-piece PMMA IOL with 12. 0 mm overall length; group 3, three-piece foldable acrylic IOL with 13.00 mm PMMA haptic distance; group 4, the same IOL as group 1. While continuous circular capsulorhexis was the type of capsulotomy in the first three groups, envelope capsulotomy was used in group 4. Mean tilt and decentration were significantly less when capsulorhexis technique was used in comparison with envelope capsulotomy. Mean tilt of group 1 (2.83+/-0.89 degrees) and mean decentration of group 2 (0.28+/-0.14 mm) were higher within the first three groups. The differences regarding both the IOL decentration and tilt between the first three groups were statistically significant. This study shows that if the IOLs were placed properly in the capsular bag after continuous circular capsulorhexis, foldable acrylic IOLs with PMMA haptics are superior in terms of tilt and decentration.

Acrylates↗

Postage stamp multiple anterior capsulorhexisotomies in pediatric cataract surgery.

BACKGROUND: Capsule related complications are common following pediatric cataract surgery. We report a new technique of multiple anterior capsulorhexisotomies after lens aspiration and intraocular lens (IOL) implantation. METHODS: After performing automated lens aspiration, an IOL was implanted into the capsular bag. A bent 26 gauge needle was introduced through one side port and multiple small cuts were made in one half of the circumference of the anterior capsular rim by making a radial movement of the needle tip centripetally over the margin of the anterior capsular rim. The needle was again introduced through the other side port and multiple similar cuts were made in the other half thereby creating nearly 20 - 30 cuts at the margin of the anterior capsular rim. RESULTS: The mean size of the primary capsulorhexis was 4.33 +/- 0.20 mm. A uniform enlargement of the capsulorhexis could be performed in all the eyes without peripheral extension in any of the eyes. There was no damage to the posterior capsule and no scratch mark on the IOL. In one eye, the primary capsulorhexis was slightly eccentric, though it was covering the IOL optic all around. The rhexisotomies in this eye were limited to the capsular rim that was overlapping more on the IOL optic (sectoral anterior capsulorhexisotomies). CONCLUSION: The technique of postage stamp anterior capsulorhexisotomies is a feasible technique in pediatric cataracts.

Capsulorhexis↗

Pseudo-accommodation with intraocular lenses implanted in the bag.

PURPOSE: To evaluate the accommodation potential in eyes after intraocular lens in-the-bag implantation. METHODS: Fifty-one consecutive patients were included in the study. Group 1 included 26 eyes that had phacoemulsification with continuous curvilinear capsulorhexis and in-the-bag implanted foldable IOL. Twenty-five eyes in Group 2 had capsulotomy with extracapsular cataract extraction and were implanted with polymethylmethacrylate IOL. Time elapsed from surgery was at least 6 months. There was no significant difference for age or gender between groups (P > .05). We measured accommodation amplitude and depth of the anterior chamber at distance and near fixation with an ultrasonic biometry device. The results were compared using the unpaired Student t-test. RESULTS: The anterior chamber depths while fixating at a distant object were not significantly different between groups (P>.05), however, at near the difference was statistically significant (P=.008). The change in depths between far and near fixation was significantly different (P=.002) and was more pronounced in the the capsulorhexis group (P < .001). The accommodation amplitudes in this group were significantly greater than in the capsulotomy group (P = .025). CONCLUSION: Patients who had uncomplicated small incision phacoemulsification surgery with continuous curvilinear capsulorhexis and in-the-bag implanted lens seemed to preserve some pseudo-accommodation after surgery.

Accommodation, Ocular↗

Retrospective comparison of surgical techniques to prevent secondary opacification in pediatric cataracts.

PURPOSE: To evaluate the effect of different surgical methods for management of the posterior capsule and anterior vitreous on the rate of posterior capsule opacification in pediatric cataracts. METHODS: Charts of 34 children (47 eyes) aged 40 days to 18 years (mean: 8.5 years) who had primary cataract surgery with or without posterior chamber intraocular lens (IOL) implantation during the past 5 years were reviewed. In 26 eyes, cataracts were managed with a posterior continuous curvilinear capsulorhexis, and in 21 eyes, the posterior capsule was left intact. Follow-up averaged 10 months (range: 6.5 months to 5 years). RESULTS: Visually significant secondary cataract developed in nine eyes with intact posterior capsules, and seven eyes required Nd:YAG laser posterior capsulotomy. The average time for YAG capsulotomy postcataract removal in the second group was 4 months. The visual axis remained clear in all eyes that had posterior continuous curvilinear capsulorhexis with or without posterior chamber IOL. Complications such as fibrinoid membrane, stromal edema, posterior synechiae, updrawn pupil, and transient glaucoma occurred in both groups at a similar rate. CONCLUSION: Primary posterior continuous curvilinear capsulorhexis is an effective method for preventing secondary cataract formation in pediatric cataracts.

Adolescent↗

[Preliminary results of intraocular lens implantation in infants with cataract under two years old].

OBJECTIVE: To explore the feasibility of anterior and posterior capsulorhexis combined with anterior vitrectomy and intraocular lens implantation in infants with cataract under 2 years old. METHODS: Anterior and posterior capsulorhexis combined with anterior vitrectomy and intraocular lens implantation was performed in 22 cases (27 eyes) of infants with cataract under 2 years old. The results during and after the operation were observed. The mean follow-up time was 12 months. RESULTS: All surgeries were performed smoothly. The visual axis remained clear in 26 eyes (96%) after operation, there was white fibrosis and opacification posterior to the intraocular lens in 1 eye and needed re-operation, up drawn pupil in 3 eyes (11%), pupillary capture in 2 eyes (7%) and posterior synechia of the iris in 4 eyes (15%). CONCLUSIONS: Anterior and posterior capsulorhexis combined with anterior vitrectomy and intraocular lens implantation in infants with cataract under 2 years old can keep visual axis clear and restore the normal anatomy of anterior segment of the eye, the complications are reduced greatly. However, the ultimate visual acuity needs further observation.

Anterior Eye Segment↗

One-year follow-up of bag-in-the-lens intraocular lens implantation in 60 eyes.

PURPOSE: To report the feasibility and clinical results of implanting a bag-in-the-lens intraocular lens (IOL) designed to prevent posterior capsule opacification after cataract surgery. SETTING: Departments of Ophthalmology, University of Antwerp, Antwerp, Belgium, and University of Munich, Munich, Germany. METHODS: This prospective study comprised 63 eyes (55 patients; 7 children, 48 adults) scheduled for cataract surgery and bag-in-the-lens IOL implantation. A posterior curvilinear capsulorhexis the same size as the anterior capsulorhexis was created for IOL insertion. After surgery, lens epithelial cell (LEC) proliferation was documented every 6 months with a minimum follow-up of 12 months. RESULTS: Sixty of 63 eyes (95%) had implantation of the bag-in-the-lens IOL. Conversion to a conventional IOL was necessary in 2 cases. In 1 eye, postoperative luxation of the IOL into the vitreous occurred as a result of an oversized anterior and posterior capsulorhexis. Three eyes had early postoperative iris incarceration in the lens groove that required surgery. No LEC proliferation on the optic occurred during a mean follow-up of 22.7 months (range 12 to 64 months); LEC proliferation was confined to the peripheral capsular bag. CONCLUSION: Lens epithelial cell proliferation was mild and confined to the periphery of the capsular bag during follow-up, and the bag-in-the-lens IOL optic remained clear.

Adolescent↗

Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial.

PURPOSE: To measure the axial movement of an accommodating intraocular lens (IOL) induced by ciliary muscle contraction after application of pilocarpine. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred ten eyes of 55 patients with age-related bilateral cataract. METHODS: This study was divided into 3 parts. In the first, the accommodating IOL (1CU) was compared with a 3-piece open-loop acrylic IOL that served as the control. In the second, to assess the effect of capsule fibrosis on the potential accommodating performance of the accommodating IOL, extensive polishing of the anterior capsule with a slit cannula was compared with standard surgery. In the third, the effect of a posterior capsulorhexis was compared with that of standard surgery. Anterior chamber depth (ACD) was assessed with partial coherence interferometry, measured before and after topical application of pilocarpine 2%, and near visual acuity (VA) was evaluated 3 months after surgery. MAIN OUTCOME MEASURE: Pilocarpine-induced change in ACD. RESULTS: The accommodating IOL showed a forward movement under pilocarpine with a median amplitude of movement of -314 microm (95% confidence interval [CI]: -148 to -592), compared with the backward movement of 63 microm (95% CI: 161 to -41) for the open-loop control IOL (P = 0.001). Capsule polishing and a posterior capsulorhexis had no effect on IOL movement with the accommodating IOL. The median near VA with distance correction was 20/60. CONCLUSION: Pilocarpine induced a small but significant forward movement of the accommodating IOL. However, the amount of movement was calculated to result in a refractive change of <0.5 diopters (D) in most patients, reaching 1 D or slightly more in only single cases, with a large variability of movement. Neither polishing of the capsule bag nor a posterior capsulorhexis could enhance the accommodative ability.

Accommodation, Ocular↗

Histology of anterior capsule edges produced by CCC and DC.

We compared the postoperative characteristics of the anterior capsule edges produced by two incision techniques: continuous curvilinear capsulorhexis (CCC) and diathermy capsulorhexis (DC). We examined the incised rims of human and animal capsules histologically and also compared the configuration and strength of the rims produced in animal experimentation. Histological examination of rabbit lenses revealed that 0.5 seconds was sufficient for coagulation of the anterior capsule: longer times caused deeper cortical tissue damage. Experimentally produced small capsulorhexis (3.5 mm diameter) with DC produced edges were less elastic than with CCC when tension was applied.

Animals↗

What to do with limited view: the intumescent cataract.

In 1991, 2,967 consecutive cataract cases were analyzed in a prospective, observational study for the incidence of intumescent cataract. Thirty four (1.15%) of the cases were mature intumescent lenses. A deliberately small continuous curvilinear capsulorhexis (CCC) enlarged secondarily by the two-stage continuous curvilinear capsulorhexis (2-CCC) technique was the anterior capsulotomy approach of choice. Depending on the liquidity of the lens material, liquid cortex was aspirated using a 26- or 30-gauge needle before capsulorhexis or through a small CCC. Because of loss of CCC control, a can-opener capsulotomy was used in three of the 34 cases before being converted by the 2-CCC technique. The rigid nucleus was usually extracted using the down-slope nucleofractis phacoemulsification technique. Four (11.7%) of the 34 intumescent cases had anterior capsule tears during capsulotomy. Successful in-the-bag lens implantation was achieved in all cases. We describe a technique of CCC, 2-CCC, and down-slope sculpting nucleofractis phacoemulsification to manage intumescent cataracts.

Cataract↗

Evaluation of the first 100 consecutive PhacoFlex silicone lenses implanted in the bag through a self-sealing tunnel incision using the Prodigy inserter.

We evaluated the performance of the PhacoFlex silicone lens with open polypropylene loops and the disposable Prodigy inserter in a series of 100 consecutive no-stitch cases. Loading the lens into the PRO-1A inserter model was easy, as was inserting it through a 4 x 4 mm self-sealing sclerocorneal tunnel incision. If the chamber was deep and the capsular fornix expanded, unfolding the polypropylene loops was safe and direct bag placement was always possible. If the capsular bag was insufficiently distended, however, the posterior loop tended to entangle with wrinkles in the posterior capsule, jeopardizing the capsule's integrity. With a round and well-centered 4 mm to 5 mm capsulorhexis, centration was good provided the lens was completely within the bag. Even with proper bag placement of the haptics, however, the optic occasionally decentered slightly and tilted because of secondary capture in the capsulorhexis opening. With an incomplete capsulorhexis or a jagged-edged capsulotomy, malpositioning was not uncommon. This was due to secondary displacement of one haptic into the sulcus or partial capture of the optic by the anterior capsule leaf. Because of the flexibility of the polypropylene loops, the lenses tended to decenter and tilt following capsular shrinkage.

Aged↗

Early central posterior capsular fibrosis in sulcus-fixated biconvex intraocular lenses.

A series of 228 eyes implanted with one-piece all poly(methyl methacrylate) (PMMA) biconvex posterior chamber intraocular lenses was examined for posterior capsule opacification. One hundred forty-one eyes (61.8%) had opacification at an average postoperative period of 19.7 months. Seventy eyes (30.7%) developed an unusual form of early central posterior capsular fibrosis (ECPCF), which was confined to the capsulorhexis opening, sparing the peripheral aspect of the anterior and posterior capsules. Risk factors for developing this form of opacification were close apposition of peripheral anterior and posterior capsules caused by placing a posteriorly vaulted biconvex optic anterior to a capsulorhexis opening smaller than the optic diameter. This opacification occurred most often in cases of haptic fixation in the ciliary sulcus. The cumulative capsulotomy rate in this series was 5.26% at three months, 9.1% at 12 months, and 13.2% at 20 months. Of the ECPCF cases, 34.3% eventually required neodymium: YAG (Nd:YAG) laser capsulotomy; the capsulotomy rate for ECPCF was 4.8 times higher than that for Elschnig pearls. Early onset of ECPCF (average onset = 19.4 weeks) resulted in early Nd:YAG capsulotomy (average = 8.0 months after surgery). One-piece all-PMMA biconvex intraocular lenses may promote early central fibrosis of the posterior capsule if the lens optic is anterior to a capsulorhexis opening smaller than the optic diameter. The early onset of this form of opacification predisposes to earlier Nd:YAG capsulotomy with a higher risk of complications.

Adult↗

Strength of the lens capsule during hydroexpression of the nucleus.

In planned extracapsular cataract extraction, hydroexpression of the nucleus has been introduced to facilitate nucleus delivery when performing capsulorhexis. The hydroexpression technique induces a fluid pressure in the capsular bag, which may rupture the posterior capsule. In a human cadaver eye model the pressure at the capsule's rupture point was determined in 16 cadaver eyes and compared to the fluid pressure in the capsular bag during hydroexpression of the nucleus in 32 eyes. The posterior capsule was able to withstand a pressure of 59 +/- 10 mm Hg (mean +/- SD) without rupturing. During hydroexpression of the nucleus the pressure was less than 12 mm Hg (3 mm Hg to 12 mm Hg) when the diameter of the capsulorhexis opening was 5.5 mm or more (measurement in the anterior chamber). Thus hydroexpression of the nucleus seems to be a safe technique when the diameter of the capsulorhexis is 5.5 mm or more.

Adult↗

Centration of intraocular lenses with circular haptics.

PURPOSE: To evaluate two intraocular lens (IOL) models with a circular haptic configuration designed to better distribute forces within the capsular bag over 360 degrees. SETTING: University and Maria Middelares hospitals, Antwerp, Belgium. METHODS: Two IOLs with circular haptics were evaluated for 6 months after implantation: a one-piece, all-poly(methyl methacrylate) (PMMA), Corneal IS M 5.5 lens with a 5.5 mm biconvex optic, overall diameter of 9.8 mm, and two semicircular open haptics (n = 103); a plano-convex, all-PMMA, modified Anis lens with a 5.5 mm plano-convex optic, total diameter of 10.0 or 11.0 mm (depending on diopter), and closed-loop haptics (n = 335). All lenses were inserted through a 5.5 mm scleral incision after phacoemulsification and placed in the capsular bag through a 4.5 mm curvilinear capsulorhexis. The IOLs centered without being rotated. RESULTS: Six months after implantation, the IOL optics were well centered, even in eyes with an eccentric capsulorhexis (19%). In two eyes with partial zonulysis and in seven with posterior capsule rupture, decentration of less than 0.5 mm was observed. Both lenses provided uniform capsular support without causing stress lines in the posterior capsule. There were no cases of capsule contraction syndrome. Posterior capsule fibrosis reducing visual acuity occurred in 4% of eyes in both series. CONCLUSION: The Corneal IS M 5.5 and the Anis lens with circular haptics prevented late optic decentration and, therefore, would be useful in cases of eccentric capsulorhexis, partial zonulysis, anterior radial tears, and posterior capsule rupture. These IOLs may also prevent capsular contraction.

Adult↗

Comparison of two acrylic intraocular lenses with different haptic designs in patients with combined phacoemulsification and pars plana vitrectomy.

PURPOSE: The intra- and postoperative characteristics of two foldable single-piece intraocular lenses (IOL) with identical hydrophilic acrylic material, but different haptic designs (Akreos Adapt and Akreos Fit), were compared in combined phacoemulsification and pars plana vitrectomy (PPV). METHODS: This was a prospective, randomized study in patients with simultaneous cataract and vitreoretinal surgery. Group A (n=47 patients) included implantation of Akreos Fit IOL (two-point haptic) and group B (n=46 patients) implantation of Akreos Adapt IOL (four-point haptic). All intraoperative modifications of small-incision phacoemulsification and three-port PPV and IOL implantation and centration were documented. At 1 and 2 days and 6 months after surgery, best-corrected visual acuity (BCVA), slit-lamp appearance (including inflammation, IOL centration, capsulorhexis diameter, posterior capsule opacification (PCO), tonometry, and fundus findings were evaluated. RESULTS: The groups did not differ with respect to age, surgical indications and modifications, intraoperative IOL handling, and centration. At day 2, inflammation and capsulorhexis diameters were similar, but IOL decentration was slightly more frequent with Akreos-Fit IOLs. Six months after surgery, the rates of PCO, posterior synechiae, and BCVA were similar. Akreos-Fit had slightly smaller capsulorhexis diameters and slightly more capsular contraction and IOL decentration (P>0.05). CONCLUSIONS: Both of the Akreos IOL are feasible for combined phacoemulsification and PPV. Although similar in intraoperative handling, BCVA, and PCO, IOL centration was slightly better with Akreos-Adapt than with Akreos-Fit after combined surgery.

Aged↗

[Lens position following planned capsular sac fixation: results of 200 consecutively surgically treated phacoemulsifications].

A total of 200 phacoemulsifications with planned in-the-bag fixation of one piece PMMA posterior chamber lenses implanted consecutively by one surgeon were examined on postoperative days 3-7. Special attention was given to both position of the haptics and centering of the lens. No sodium hyaluronate or other viscoelastic materials were used in any of the operated eyes. After capsulorhexis and phacoemulsification inside the bag we were able to confirm in-the-bag fixation in 190 implants (95%). In 197 of the 200 patients centering of the IOL was excellent. The capsular rim of the circular capsulorhexis was preserved in all cases due to phacoemulsification within the capsular bag. This procedure meets the best conditions for a secure in-the-bag insertion of the posterior chamber lens. Expression of the lens nucleus after capsulorhexis or through the so-called letter-box technique leads to a remarkably lower percentage of proven bag-bag fixation of the haptics.

Cataract Extraction↗

Accommodation amplitude after lens refilling with injectable silicone by sealing the capsule with a plug in primates.

OBJECTIVE: To restore accommodation in primate eyes by refilling the lens capsule with injectable silicone compounds. MATERIALS AND METHODS: Eight eyes of 8 monkeys (Macaca fascicularis) were treated by the lens refilling procedure. To prevent leakage of the injected liquid silicone before it polymerized in the capsule in vivo, a silicone plug for sealing the capsular opening was developed. After endocapsular phacoemulsification following an upper minicircular capsulorhexis, the plug was introduced into the capsulorhexis opening. A silicone mixture was injected into the capsular bag through the delivery tube of the plug. Automated refractometry was performed 1 week and 3 months after surgery. Accommodation amplitude was determined as the difference between the refractions before and 1 hour after topical application of 4% pilocarpine chloride. RESULTS: Five of 8 eyes could be refilled. In 4 of 5 eyes, refraction could be measured. Accommodation amplitude ranged from 1.0 to 4.5 diopters, with a mean of 2.3 +/- 1.3 diopters (8.0 +/- 2.0 preoperative values). At 3-month examination, thick posterior capsule opacification precluded refractometry in all eyes. CONCLUSIONS: The lens refilling procedure with the use of a silicone plug for sealing the capsular opening was feasible in primate eyes. The accommodation amplitude attained was a small fraction of the value before surgery. This may result from the loss of so-called intracapsular accommodation, ie, active participation of lens fiber cells in accommodation. However, since the obtained accommodation may be sufficient for near vision after cataract surgery, this lens refilling procedure warrants further study. Elucidation of the mechanism of intracapsular accommodation may also be necessary.

Accommodation, Ocular↗

Anterior vitreous face behavior with AcrySof in pediatric cataract surgery.

PURPOSE: To describe anterior vitreous face behavior when AcrySof (Alcon, Fort Worth, TX) intraocular lenses come in contact with the anterior vitreous face after posterior continuous curvilinear capsulorhexis without anterior vitrectomy in pediatric patients undergoing cataract surgery. METHODS: This study comprised 14 eyes of 12 children whose mean age was 9.6 years (range, 2.3 to 16.0). All eyes underwent primary posterior continuous curvilinear capsulorhexis without anterior vitrectomy and had AcrySof IOLs implanted in the bag. Changes on the anterior vitreous face were documented, and visual acuity was recorded. Statistical analysis was performed using Student group t and Mann Whitney tests. RESULTS: Mean length of follow-up was 21.1 +/- 7.4 months (range, 15.0 to 36 months). Nine eyes (64.3%) had a clear visual axis, whereas 5 eyes (35.7%) developed anterior vitreous face changes. Of those with anterior vitreous face changes, 60% (3 of 5) eyes showed a fine meshwork-like reticular response termed "anterior vitreous reticular response" (AVR); 20% (1 of 5) eyes showed a scaffold response; and 20% (1 of 5) eyes showed a mixed response at the last follow-up examination. The difference in visual acuity before and after the development of the AVR response was not significant (P =.712). The mean age of patients with eyes having a clear visual axis was 12.1 +/- 2.3 years (median = 11.0; range, 9.1 to 16.0), and the mean age of patients with eyes having anterior vitreous face changes was 5.1 +/- 3.4 years (median = 3.6; range, 2.3 to 11.6) (P =.0098). CONCLUSION: The results suggest that when the AcrySof intraocular lenses come in contact with the anterior vitreous face, they produce the AVR response during the early postoperative period in younger eyes. This does not seem to have any significant impact on visual acuity.

Acrylic Resins↗

Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

PURPOSE: To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. RESULTS: The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. CONCLUSIONS: The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

Animals↗