Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CLOTHING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

[Investigations on the clothing of preschool-children during winter (author's transl)].

These investigations should control the effect of increased indoor-temperatures in facilities for children and flats on the clothing-habits of 1--3 aged children during the heating period. The indoor- and outdoor-clothing was scored by the number of dress-layers investigated in 977 crèche-children. All these attempts were carried out while 23 days during the winter 1976/77 in 2 crèches which differed significantly referring to the distribution of indoor-temperature. The statistical evaluation results that all children were dressed nearly in the like wise in spite of a considerable difference of the temperature in both crèches; only the covering of the arms was significant less in the warmer new-builded crèch. The investigations showed further that the outdoor-clothing of the children was often not according to the climate. Even 10 degrees C difference of temperature were rarely followed by variations of the outdoor-clothing. Finally the dress of 1--3 aged children can be estimated as too abundant.

Child Care↗

Continuous vs. intermittent work with Canadian Forces NBC clothing.

This study examined the benefits of work and rest schedules on soldiers' work tolerance (WTT) while wearing various levels of nuclear, biological and chemical (NBC) defence protective clothing in a warm environment (30 degrees C and 50% R.H.). Eight unacclimatized males were assigned to exercise at either a light (walking 1.11 m.s-1 0% grade, alternating with lifting 10 kg) or heavy metabolic rate (walking 1.33 m.s-1 7.5% grade, alternating with lifting 20 kg). Subjects were tested wearing three levels of clothing protection: combat clothing (L); combats and a semi-permeable NBC overgarment with the hood down (M); combats and NBC overgarment, gloves, boots and respirator (H). For each clothing configuration, subjects were evaluated using both a "continuous" exercise protocol and an intermittent work and rest schedule. WTT was defined as the time until rectal temperature (Tre) reached 39.3 degrees C, heart rate reached 95% maximum, dizziness or nausea precluded further exercise, or 5 h had elapsed. Assuming a resting VO2 of 4 ml.kg-1 x min-1 an average metabolic rate was calculated for all trials. A decreasing hyperbolic function described the relationship between WTT and metabolic rate for M and H. These relationships facilitate quantification of appropriate work and rest schedules if the metabolic rate of a task is known.

Adult↗

The effects of wearing protective chemical warfare combat clothing on human performance.

U.S. Department of Defense studies to measure performance decrements associated with wearing chemical warfare (CW) protective combat clothing indicate that heat stress seriously degrades human performance. Even when heat stress is not a significant factor, performance of many combat, combat support, and combat service support tasks is degraded. In most field studies, many crews of combat units became operationally ineffective due to voluntary withdrawal of individual crewmembers. Many combined arms, field studies, and laboratory studies indicate that when CW-protective combat clothing is worn performance is seriously degraded for the detection of targets, engagement time, accuracy of fire, and manual dexterity tasks; and that a variety of psychological effects are created. Further, the degree of performance degradation varied with the tasks performed. Training in CW-protective combat clothing permits learning to modify procedures and consequently reduce negative effects, provided heat stress is not a significant factor. A growing body of evidence indicates there is inadequate training in the use of CW-protective combat clothing. A critical need exists for more and better training of skills needed under CW-conditions.

Chemical Warfare↗

Postmortem insect activity may mimic perimortem sexual assault clothing patterns.

Determination of perimortem sexual assault can be confounded in homicide cases in which only badly decomposed or skeletal remains are recovered. One indicator of assault is a characteristic pattern of clothing disarray, including tearing, removal, or displacement of clothing. Preliminary findings from two studies of clothed pig carrion of approximate human size (59 to 162 kg) reveal that postmortem insect activity, particularly maggot masses, and natural decompositional changes such as bloating can produce changes to clothing which mirror those seen in cases of sexual assault.

Animals↗

Production of galacto-oligosaccharides from lactose by Aspergillus oryzae beta-galactosidase immobilized on cotton cloth.

The production of galacto-oligosaccharides (GOS) from lactose by A. oryzae beta-galactosidase immobilized on cotton cloth was studied. The total amounts and types of GOS produced were mainly affected by the initial lactose concentration in the reaction media. In general, more and larger GOS can be produced with higher initial lactose concentrations. A maximum GOS production of 27% (w/w) of initial lactose was achieved at 50% lactose conversion with 500 g/L of initial lactose concentration. Tri-saccharides were the major types of GOS formed, accounting for more than 70% of the total GOS produced in the reactions. Temperature and pH affected the reaction rate, but did not result in any changes in GOS formation. The presence of galactose and glucose at the concentrations encountered near maximum GOS greatly inhibited the reactions and reduced GOS yield by as much as 15%. The cotton cloth as the support matrix for enzyme immobilization did not affect the GOS formation characteristics of the enzyme, suggesting no diffusion limitation in the enzyme carrier. The thermal stability of the enzyme increased approximately 25-fold upon immobilization on cotton cloth. The half-life for the immobilized enzyme on cotton cloth was more than 1 year at 40 degrees C and 48 days at 50 degrees C. Stable, continuous operation in a plugflow reactor was demonstrated for 2 weeks without any apparent problem. A maximum GOS production of 21 and 26% (w/w) of total sugars was attained with a feed solution containing 200 and 400 g/L of lactose, respectively, at pH 4.5 and 40 degrees C. The corresponding reactor productivities were 80 and 106 g/L/h, respectively, which are at least several-fold higher than those previously reported.

Aspergillus oryzae↗

Investigation of removal of Cr(VI), Mo(VI), W(VI), V(IV), and V(V) oxy-ions from industrial waste-waters by adsorption and electrosorption at high-area carbon cloth.

Adsorption and electrosorption of Cr(VI), Mo(VI), W(VI), V(IV), and V(V) ions from water samples at low concentration were studied at high-area C-cloth electrodes. The concentrations of ions in the solution were monitored using in situ UV spectroscopy. All the investigated ions, except V(IV), showed better adsorption in acidic media. Positive polarization of the C-cloth caused increased adsorption of Cr(VI), Mo(VI), and V(V) ions. When previously adsorbed, Mo(VI) and V(V) ions were shown to be largely desorbable by negative polarization of the C-cloth. Since V(IV) does not become adsorbed significantly at the C-cloth in acidic media, the method provides an interesting means for separation of V(V) and V(IV) species in solution.

Journal Article↗

Identification of human urine stains on cloth.

Experimental stains of human urine prepared on 4 different types of cloth and cloth stains in practical cases were examined by 2 methods which have been established in this laboratory. A chemical method determining uric acid and urea nitrogen content and an enzyme-linked immunosorbent assay (ELISA) to determine uromucoid. The former method uses the quotient uric acid/urea nitrogen as an indicator and the latter the quotient ELISA score/protein concentration. All stains were identified as human urine stains by both methods when the specimens were taken from the centre of the stains but when taken from the periphery some of them, especially those on cloth such as cotton or silk, could not be identified as human urine stains. These results indicate that the central part of stains should be preferentially used for the identification of human urine stains, especially those made on cloth such as cotton or silk.

Adult↗

Measurement of the clothing ventilation index.

In order to achieve thermal comfort while wearing protective clothing, heat loss from the body by convection and by the evaporation of sweat must be readily controlled by the wearer's thermoregulatory system. This can only be achieved if air is flowing through the clothing micro-environment in sufficient quantity to remove sensible and insensible heat as required. The volume flow of air through the clothing assembly is therefore an important determinant of thermal comfort. This paper describes a new procedure for estimating under working conditions, the volume of air flowing through the micro-environment. The method is based on two techniques: the first gives a measure of the volume of the micro-environment; the other uses a trace gas to measure the rate of air exchange. Algebraic combination of the results enables the air exchange characteristics of a garment to be described in terms of a Ventilation Index. It is proposed that this index be used to describe the performance of protective clothing assemblies.

Journal Article↗

Protective clothing systems: A technique for evaluating restriction of wearer mobility.

To allow designers to evaluate presently available protective clothing systems (as well as aiding the development of less restrictive systems), it is necessary to develop evaluation techniques to quantify the loss of mobility associated with wearing protective clothing. Using fire fighter turnout gear, this study illustrated the application of the Leighton Flexometer for the measurement of restriction to body movement caused by wearing protective clothing and equipment. Statistical analyses indicated significant differences in restriction to body movement between the designs of protective clothing and equipment configurations tested. Additionally, correlation coefficients between trials established values for tes-retest reliability.

Journal Article↗

Use of hydrophobic cloths as antibody adsorbents for enzyme immunoassay: detection of Brucella antigens.

A cloth-ELISA (C-ELISA) antigen capture assay for the detection of Brucella melitensis and B. abortus was developed. Segments (6-mm squares) of hydrophobic polyester cloth coated with diluted serum from a B. abortus-infected cow were incubated with saline suspensions of heat-killed Brucella cells, or with cultures of bovine or sheep blood or bovine tissue homogenates that had been inoculated with B. abortus or B. melitensis added to trypticase soy broth (TSB) and incubated for 2-3 days. The captured antigen was detected by a bovine anti-Brucella antibody-horseradish peroxidase conjugate system. The enrichment culture technique detected as few as three Brucella colony-forming units (c.f.u.) in 0.5 ml of bovine blood and was positive in cultures in which the Brucella concentration had reached 3 X 10(6) c.f.u. ml-1 (after 2 or 3 days incubation). The combined enrichment-cloth-ELISA method gave complete correlation with cultural isolation and results were available 3 days before colonies appeared in conventional culture. Hydrophobic cloths have potential use in diagnostic procedures since they provide simple, rapid and economical assays.

Animals↗

Late complications of aortic valve replacement with cloth-covered, composite-seat prostheses. A six-year appraisal.

Advanced actuarial techniques are used to analyze early and late results in a closely followed series of 396 patients who received a cloth-covered, composite-seat aortic prosthesis. Late mortality and various complications are carefully assessed, and most late deaths are seen to be unrelated to the prosthesis. One hundred sixteen patients with Model 2310-2320 prostheses who received warfarin postoperatively had no thromboembolic complications in 360 patient-years of follow-up (average, 3.1 years per patient); 134 patients who had the same prosthesis but did not receive warfarin had 9 emboli per 100 patient-years (average follow-up, 1.7 years per patient; total, 228 patient-years). By comparison, in 9 years' experience with non-cloth-covered Model 1200-1260 valves, 132 patients had 4.0 emboli per 100 patient-years (average follow-up, 5.1 years; total, 673 patient-years). The safety of cloth-covered valves is clearly enhanced by concomitant use of anticoagulants; the possibility that antiplatelet drugs may suffice has not yet been demonstrated. Strut cloth wear was found at reoperation in 10 patients. The Model 2400 composite strut ("track") valve with a narrow metal track on the inner surface of each strut prevents this complication.

Adolescent↗

Visual alliesthesia--cloth color preference in the evening under the influence of different light intensities during the daytime.

The primary purpose of this study was to determine the effect of bright and dim light exposure during the daytime on cloth color preference in the evening. Ten healthy female volunteers were exposed to bright light of 5000 lx ("Bright") or dim light of 200 lx ("Dim") from 0730 +/- 1 h to 1800 hours, 200 lx from 1800 hours to 2330 +/- 1 h, and complete darkness during the sleep period (2330 hours +/- 1 h to 0730 +/- 1 h). The subjects were instructed to select the most preferable single one out of 41 cloth colors (24 x 52 cm, 100% cotton), every 5 min from 2100 hours to 2200 hours. Most subjects preferred a warmer cloth color in the Dim condition. The rectal temperature showed clear circadian rhythm both under Bright and Dim conditions but it was significantly lower during sleep in the Bright condition. On the contrary, leg skin temperature was significantly higher during the evening and sleep in the Bright. It is concluded that warmer cloth color is preferred in the evening after Dim condition at an ambient temperature, being based on the higher set point of core temperature after Dim.

Adult↗

Glass on clothing and shoes of members of the general population and people suspected of breaking crimes.

The outer clothing and footwear of 122 people attending a university gymnasium and a private gymnasium were searched for fragments of glass. Both the surfaces and the pockets of the clothing and the uppers and soles of the footwear were searched. New Zealand forensic glass cases have been reviewed to determine the amount of non-matching glass present on the clothing of people who are suspected of breaking crimes. Data from 114 suspects who had no matching glass on their clothing and shoes were accumulated. Statistical modelling techniques have been applied to the data collected.

Journal Article↗

Removal of micro-organisms by filtration through unwoven cloth coated with a pyridinium-type polymer.

Unwoven cloth coated with 32 mg/g of a copolymer of N-benzyl-4-vinyl-pyridinium chloride and styrene was found to be effective in removing micro-organisms from water. In experiments demonstrating removal of Escherichia coli by filtration through ten sheets of the unwoven cloth, the rate of removal was 99.99% at a filtration rate of 2.6 cm/h, and remained at 99% even at a high filtration rate of 300 cm/h and a low influent concentration of the bacterial cells such as 10(3) cells/ml. The rate of removal tended to increase with a decrease in the influent bacterial concentration. Seven other bacteria and two yeasts were effectively removed by filtration through the unwoven cloth. Filtration through the unwoven cloth was also effective in removing spores of fungi from water but was not very effective in removing bacteriophage T4 from aqueous solution.

Bacteria↗

Hydroxyapatite formation on cellulose cloth induced by citric acid.

Hydroxyapatite (HAp) formation on cellulose cloth with the aid of citric acid was investigated. The cellulose cloths were soaked in simulated body fluid (SBF) solutions (1.5 SBF) with ion concentrations 1.5 times that of SBF (1.0 SBF) with and without citric acid and carbonate containing HAp crystals were found to form only in the 1.5 SBF solution that contained citric acid. The results were explained in terms of hydrogen bonding of citric acid to the cellulose cloth and its chelating ability of calcium ions. Practical application may involve the inclusion of citric acid in the 1.5 SBF solution to promote formation of HAp on previously bioinert cellulose cloth.

Journal Article↗

Adsorption of toluene onto activated carbon fibre cloths and felts: application to indoor air treatment.

Due to their bad effects on human health, removing Volatile Organic Compounds from indoor air has become an issue of major interest. In this study, the potential use of six commercial activated carbon felts and cloths for indoor toluene removal was investigated. Both batch and dynamic adsorption studies were performed, at toluene concentrations ranging from 21 to 18160 mg m(-3), for an air velocity representative of indoor air treatment (0.37 m s(-1)). Batch measurements showed that felts exhibited higher adsorption capacities at equilibrium than cloths at high toluene concentrations, whereas this trend may be inverted at low concentrations. Experimental isotherms and kinetics were satisfactorily fitted by the Langmuir-Freundlich model and the Linear Driving Force model respectively. No main differences between the adsorption kinetics of felts and cloths were reported. Dynamic adsorption capacities at saturation appeared to be higher than 120 mg g(-1) for both cloths and felts, irrespective of relative humidity levels and toluene concentrations. The influence of relative humidity on the adsorption capacity of felts was not significant for the higher toluene concentration studied in dynamics (307 mg m(-3)), whereas an increase in relative humidity induced a decrease in adsorption capacity at the lower toluene concentration (38 mg m(-3)). Moreover, experimental curves of breakthrough time versus thickness of medium were satisfactorily fitted by the Adams-Bohart model, and the critical thickness determined by this model appeared to be below 1.3 mm, regardless of the medium or toluene concentration.

Adsorption↗

Comparison of cloth gloves used in orthopaedic surgery: a clinical and experimental evaluation.

OBJECTIVES: (a) To compare the effectiveness of five cloth gloves for cut resistance and their ability to prevent inner latex glove perforation. (b) To evaluate the safety, efficacy, and comfort of the outer gloves when reused. SETTING: Tertiary care level I trauma hospital and biomechanics laboratory. METHODS: Laboratory evaluation consisting of assessing cut resistance and fabric deterioration and clinical assessment of all cloth gloves worn as a liner between two latex gloves. RESULTS: Laboratory testing demonstrated significant differences in cut resistance, with gloves divided into three groups: most resistant (Centurion, which required over 3,000 slices or 1,300 chops to failure), resistant (MedArmor, failing at eighty-five slices or 121 chops; Paraderm, failing at thirty-eight slices or ninety-four chops; and Repel, failing at forty-six slices or seventy-five chops), and least resistant (Protek, failing at two slices and less than two chops). Clinically, 3 percent of all the inner latex gloves demonstrated a perforation, with no violation of the skin in any of the five types of cloth gloves used. Only the Protek and MedArmor cloth gloves were positively ranked for comfort. CONCLUSION: All gloves provided equal protection with respect to inner latex glove perforation during all of the orthopaedic procedures, with comfort being the most important variable. Gloves should be selected based on comfort, because it appears that all gloves provide equal protection during surgery regardless of the material woven into the fabric.

Equipment Failure Analysis↗

Image-based collision detection for deformable cloth models.

Modeling the natural interaction of cloth and garments with objects in a 3D environment is currently one of the most computationally demanding tasks. These highly deformable materials are subject to a very large number of contact points in the proximity of other moving objects. Furthermore, cloth objects often fold, roll, and drape within themselves, generating a large number of self-collision areas. The interactive requirements of 3D games and physically driven virtual environments make the cloth collisions and self-collision computations more challenging. By exploiting mathematically well-defined smoothness conditions over smaller patches of deformable surfaces and resorting to image-based collision detection tests, we developed an efficient collision detection method that achieves interactive rates while tracking self-interactions in highly deformable surfaces consisting of a large number of elements. The method makes use of a novel technique for dynamically generating a hierarchy of cloth bounding boxes in order to perform object-level culling and image-based intersection tests using conventional graphics hardware support. An efficient backward voxel-based AABB hierarchy method is proposed to handle deformable surfaces which are highly compressed.

Journal Article↗